APW Wyott

HMG-2448i - Grill APW Wyott - Free user manual and instructions

Find the device manual for free HMG-2448i APW Wyott in PDF.

📄 18 pages English EN Download 💬 AI Question
Notice APW Wyott HMG-2448i - page 1
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about HMG-2448i APW Wyott

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Grill in PDF format for free! Find your manual HMG-2448i - APW Wyott and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HMG-2448i by APW Wyott.

USER MANUAL HMG-2448i APW Wyott

(US & Canadian units are convertible and are assembled for Natural Gas) (European units are not convertible and assembled for the appropriate gas)

IMPORTANT FOR FUTURE REFERENCE

Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or Parts, this information is required.

Model Number Serial Number Date Purchased

APW Wyott HMG-2448i - IMPORTANT FOR FUTURE REFERENCE - 1

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

APW Wyott HMG-2448i - IMPORTANT FOR FUTURE REFERENCE - 2

APW Wyott HMG-2448i - IMPORTANT FOR FUTURE REFERENCE - 3

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, or servicing this equipment.

APW Wyott HMG-2448i - IMPORTANT FOR FUTURE REFERENCE - 4

APW Wyott HMG-2448i - IMPORTANT FOR FUTURE REFERENCE - 5

WARNING: Instructions must be posted in a prominent location. All safety precautions must be taken in the event the user smells gas. Safety information can be obtained from your local gas supplier

APW Wyott HMG-2448i - IMPORTANT FOR FUTURE REFERENCE - 6

APW Wyott HMG-2448i - IMPORTANT FOR FUTURE REFERENCE - 7

APW Wyott HMG-2448i - IMPORTANT FOR FUTURE REFERENCE - 8

P/N 8822241 9/24/13

APW Wyott MANUFACTURING

DALLAS:

1307 N. Watters Rd #180 • Allen, TX • 75013

Local: (972) 908-6100 Local: (307) 634-5801

Toll Free: (800) 431-2745 Toll Free: (800) 752-0863

Parts/Service Fax: (214) 565-0976 Parts/Service Fax: (214) 565-0976

CHEYENNE:

1938 Wyott Dr • Cheyenne, WY • 82007

TABLE OF CONTENTS

ITEMPAGEITEM
Safety Precautions3Cleaning/Maintenance 9
General Installation Instructions4Service/Repair 9
Specifications & Dimensions5Troubleshooting Guide 10
Conversion6Replacement Parts Lists & Exploded Views 11
Lighting Instructions7Warranty 17
Operating Instructions8

LOCATION OF DATA PLATE

The data plate is located on the right side panel.

APW Wyott HMG-2448i - LOCATION OF DATA PLATE - 1

CAUTION: These models are designed, built, and sold for commercial use. If these models are positioned so the general public can use the equipment, make sure that cautions, warnings, and operating instructions are clearly posted near each unit so that anyone using the equipment will use it correctly and not injure themselves or harm the equipment.

APW Wyott HMG-2448i - LOCATION OF DATA PLATE - 2

APW Wyott HMG-2448i - LOCATION OF DATA PLATE - 3

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.

APW Wyott HMG-2448i - LOCATION OF DATA PLATE - 4

APW Wyott HMG-2448i - LOCATION OF DATA PLATE - 5

WARNING: For your safety do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Keep the area free and clear of combustibles. (See ANZI Z83. 14B, 1991).

APW Wyott HMG-2448i - LOCATION OF DATA PLATE - 6

APW Wyott HMG-2448i - LOCATION OF DATA PLATE - 7

NOTICE: Instructions to be followed if anyone smells gas should be posted in a prominent place. These may be obtained from the gas supplier.

APW Wyott HMG-2448i - LOCATION OF DATA PLATE - 8

GAS PRESSURE

The appliance and it's individual shutoff valve (to be supplied by user) must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 12 psi (3.45 kPa).

The appliance must be isolated from the gas supply piping system by closing it's individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 12 psi (3.45 kPa).

APW Wyott HMG-2448i - GAS PRESSURE - 1

WARNING: A factory authorized agent should handle all maintenance and repair. Before doing any maintenance or repair, contact APW Wyott.

APW Wyott HMG-2448i - GAS PRESSURE - 2

Congratulations on your purchase of APW Wyott commercial cooking or refrigeration equipment. APW Wyott takes pride in the design and quality of our products. When used as intended and with proper care and maintenance, you will experience years of reliable operation from this equipment. To ensure best results, it is important that you read and follow the instructions in this manual carefully.

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE

All containers should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery. If equipment is received damaged, either apparent or concealed, a claim must be made with the delivering carrier.

A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be signed by the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The carrier can supply the necessary forms.
B) Concealed damage or loss if not apparent until after equipment is uncrated, a request for inspection must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to hold all contents and packaging material.

Installation and start-up should be performed by a qualified installer who thoroughly read, understands and follows these instructions.

If you have questions concerning the installation, operation, maintenance or service of this product, write Technical Service Department APW Wyott, 1307 N Watters Rd # 180, Allen, TX 75013.

SAFETY PRECAUTIONS

Before installing and operating this equipment be sure everyone involved in its operation is fully trained and is aware of all precautions. Accidents & problems can result by a failure to follow fundamental rules and precautions.

The following words and symbols, found in this manual, alert you to hazards to the operator, service personnel or the equipment. The words are defined as follows:

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 1

DANGER: This symbol warns of imminent hazard which will result in serious injury or death.

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 2

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 3

WARNING: This symbol refers to a potential hazard or unsafe practice, which could result in serious injury or death.

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 4

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 5

CAUTION: This symbol refers to a potential hazard or unsafe practice, which may result in minor or moderate injury or product or property damage.

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 6

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 7

NOTICE: This symbol refers to information that needs special attention or must be fully understood even though not dangerous.

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 8

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 9

NOTICE: This product is intended for commercial use only. Not for household use.

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 10

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 11

CAUTION: These models are designed, built, and sold for commercial use. If these models are positioned so the general public can use the equipment make sure that cautions, warnings, and operating instructions are clearly posted near each unit so that anyone using the equipment will use it correctly and not injure themselves or harm the equipment.

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 12

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 13

WARNING: Improper installation, operation, service or maintenance can cause property damage, injury or death. Read and understand these instructions thoroughly before positioning, installing, maintaining or servicing this equipment.

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 14

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 15

WARNING: Keep the appliance free & clear of all combustible substances. If gas odor is detected at any time, immediately shut unit down at the main shutoff valve. Do not permit any open flames in the area of the appliance. Immediately contact an authorized Service Agency or your local Gas Supplier for service.

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 16

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 17

WARNING: Do not obstruct either the air inlet (underneath unit) or the ventilation air (back of unit). Provisions must be provided to provide an adequate air supply to the griddle.

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 18

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 19

NOTICE: Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc., states in its NFPA96 latest edition that local codes are "Authority Having Jurisdiction" when it comes to requirement for installation of equipment. Therefore, installation should comply with all local codes.

APW Wyott HMG-2448i - SAFETY PRECAUTIONS - 20

GENERAL INSTALLATION INSTRUCTIONS

Ensure gas supply and gas type, as shown on unit nameplate, agree.

Unit installation must conform to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as applicable and in accordance with local codes.

Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if necessary to move unit.

Pipe threading compound must be resistant to the action of liquefied petroleum gases.

Caution: DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and water solution before operating unit.

THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.

Noncombustible clearances:

0" sides (0 mm)

0" rear (0 mm)

4" floor (102mm)

Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the flue.

Adequate clearance for air openings into the combustion chamber is required. Do not place objects between the bottom of the unit and the counter top.

There must be adequate clearance for removal of the front panel. All major parts except the burners are removable thru the front if the gas line is disconnected.

Unit must have adequate clearances for servicing. (Sides = 0", Rear = 0", Floor = 4").

European Community Installation Instructions:

"THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON. IN THE UK, CORGI REGISTERED INSTALLERS (INCLUDING THE REGIONS OF BRITISH GAS) UNDERTAKE TO WORK TO SAFE AND SATISFACTORY STANDARDS. THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS AND THE RELEVANT BUILDING REGULATIONS / IEE. REGULATIONS. DETAILED RECOMMENDATIONS ARE CONTAINED IN THE FOLLOWING BRITISH STANDARD CODES OF PRACTICE - BS 6172, BS 5440 PART 2, BS 6891"

"THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE"

SPECIFICATIONS AND GRIDDLE SURFACE DIMENSIONS

MODELWIDTH IN. (MM)DEPTH IN. (MM)HEIGHT IN. (MM)# OF BURNERSBTU/kw PER BURNERTOTAL BTU/kW HOURW.C. IN.(‘Mbar’)
HMG-2424i23.844" (605.6)24" (609.6)15.437" (392.1)2 32,000(9.78) 64,000 (18.8)5 (12.4)
HMG-2436i35.844" (910.4)24" (609.6)15.437" (392.1)3 32,000(9.78) 96,000 (28.1)5 (12.4)
HMG-2448i47.844" (1215.2)24" (609.6)15.437" (392.1)4 32,000(9.78) 128,000 (37.5)5 (12.4)
HMG-2460i59.844" (1520.0)24" (609.6)15.437" (392.1)5 32,000(9.78) 160,000 (46.9)5 (12.4)
HMG-2472i71.844" (1824.8)24" (609.6)15.437" (392.1)6 32,000(9.78) 192,000 (56.3)5 (12.4)

Griddle Dimensions

MODELWIDTH(A)DEPTH(B)HEIGHT(C)LEGSPACING(D)LEGSPACING(E)
HMG-2424i24" (609.6)33.3" (846)15.5" (392.1)21.0"(533)23.6" (600)
HMG-2436i36" (914.4)33.3" (846)15.5" (392.1)33.0"(838)23.6 " (600)
HMG-2448i48" (1219.2)33.3" (846)15.5" (392.1)45.0"(1143)23.6" (600)
HMG-2460i60" (1524.0)33.3" (846)15.5" (392.1)57.0"(1448)23.6" (600)
HMG-2472i72" (1828.8)33.3" (846)15.5" (392.1)69.0"(1753)23.6" (600)

SPECIFICATIONS – HEAVY DUTY GAS GRIDDLE: HMG-2424i
APW Wyott HMG-2448i - European Community Installation Instructions: - 1

text_image B 14.5 A

APW Wyott HMG-2448i - European Community Installation Instructions: - 2

natural_image Technical line drawing of a rectangular electronic device with mounting feet and internal components (no text or symbols)

APW Wyott HMG-2448i - European Community Installation Instructions: - 3

text_image C D

APW Wyott HMG-2448i - European Community Installation Instructions: - 4

text_image 13 E 31.3 4

CONVERSION

  • Instructions are for conversion from Natural Gas to Propane (L.P.) on all models HMG.
    • The conversion should be done before connecting the unit to the gas supply.
  • Units are shipped from the factory equipped for use on natural gas. Orifices necessary for LP (propane) are provided in a bag tied to the valve on the front panel.

  • Remove the knobs and front panel.

  • Remove the orifice fittings from the valve. Change the orifices to the size recommended for propane (L.P.).
  • Replace the orifice fittings into the valve.

• To change the regulator:

APW Wyott HMG-2448i - CONVERSION - 1

text_image 1. Remove brass cap

APW Wyott HMG-2448i - CONVERSION - 2

text_image 2. Locate the plastic part attached to the brass cap

APW Wyott HMG-2448i - CONVERSION - 3

text_image 3. This is the natural gas position NAT

APW Wyott HMG-2448i - CONVERSION - 4

text_image 4. Snap the plastic part off of the brass cap

APW Wyott HMG-2448i - CONVERSION - 5

text_image 5. Flip the plastic part over & snap the plastic part onto the brass cap in the opposite direction

APW Wyott HMG-2448i - CONVERSION - 6

text_image 6. Note you can read LP on the plastic part it is now in the LP position d1

APW Wyott HMG-2448i - CONVERSION - 7

text_image 7. Replace the brass cap back into the body of the regulator

APW Wyott HMG-2448i - CONVERSION - 8

text_image 8. To adjust pressure: Remove brass cap & turn white plastic part inside the stem of regulator
  • Connect the regulator to the unit, connect gas and check for leaks. WARNING: Do not use an open flame to check for leaks.
  • Check the system pressure. With the front panel removed remove the plug - - - from the manifold.
  • Place a fitting in the plug opening and connect a manometer.
  • For Natural gas the pressure in the manifold should be 5" water column or 12.4 millibar. For LP the pressure in the manifold should be 10" water Column of 24.9 millibar.
  • To adjust the pressure remove the brass cap and turn the white plastic part inside the stem of the regulator. See picture regulator 8.
  • Take a wide straight screw driver and place it in the two notches shown in picture regulator 7 turn clockwise to increase pressure and counter-clockwise to reduce pressure. See picture regulator 8.
    • Once the pressure has been adjusted replace the brass cap.
  • Note the blue cap on the regulator, this is the vent there are openings below the top rim. NEVER block these openings your regulator will fail to operate correctly. On a monthly basis blow off any dust or grease

APW Wyott HMG-2448i - CONVERSION - 9

natural_image Close-up of mechanical components with a downward arrow indicating a process (no visible text or symbols)

which may accumulate around this cap. The openings must remain open for the regulator to function. Clean more often in a very greasy atmosphere.

LIGHTING INSTRUCTIONS

HDMG Griddles are furnished with either a pilot safety valve or a standing pilot (not available in the European Community). Please follow the instructions for your unit. HMG Griddles are furnished with either a flame failure pilot or a standing pilot (not available in the European community).

Pilot Operation HMG Flame Failure Gas Valve:

Operation on the gas valve pilot.

  1. Turn knob on the main gas valve to the pilot position.
  2. Depress knob to start gas flow to the pilot valve.
  3. Light pilot valve.

a. Using a match or taper

  1. Hold in knob for 15 to 30 seconds to heat up the thermocouple.
  2. Release knob and turn to the desired gas flow position.

a. If pilot goes out repeat steps 1-4, some thermocouples will take longer to heat up

Standing Pilot Lighting Instructions: (Not Available in the European Community)

The pilot lights on the broilers have been set at the factory. A screwdriver may be required for the first lighting to adjust the flame for your elevation.

  1. Turn off the manual shut off valve and wait 5 minutes to clear the gas.
  2. Turn all knobs to the "OFF" position.
  3. The valve can be accessed through an opening in the front panel or remove the cooking grates and light the pilot from above.
  4. Turn the manual shut off valve on.
  5. Hold an ignition source (match) to both openings on the pilot tube. When the flames are established, remove the ignition source.
  6. Turn the burner knobs to "HI". If the burner does not ignite, promptly open the pilot valve more. If the pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot flame should be as small as possible but large enough to guarantee reliable ignition of the burners when the knobs are turned to "HI".

RELIGHTING PILOT

If the pilot light should go out for any reason:

  • Promptly shut off all gas at the manual shut off valve.
    • Turn off all knobs and pilot valves; wait 5 minutes to clear gas.
  • Relight following steps 4 through 6 under Standing Pilot Lighting Instructions.

HDTG LIGHTING THE MAIN BURNER:

Since the burner is lit from constantly burning pilot, turn knobs to "HI" to put the unit in operation; then adjust to any desired position between "LO" and "HI".

  • To light burner, turn knob to "max." then back off to the desired flame level. The range of adjustment is virtually infinite between high and off. (At the small flame, there is a pre-set low).
  • When the broiler is first heated, it will smoke until oil used in manufacturing, preservation and dust from storage and shipping are burned off. An hour at "max." on all burners is usually sufficient.
  • Turn knobs off and let cool

  • For first cooking, set the grates at maximum tilt position and preheat before broiling. You will have to experiment with knob settings and grate position for each particular item.

  • Clean regularly. Grates may be removed for washing in the sink. Brush out carbonized particles. Thoroughly wash the grease/water pan.

European Community

If adjustment becomes necessary in the field, it should be done by a factory authorized and trained technician who should seal the screw after the adjustment to safeguard against unauthorized tampering by the end user.

All burners are lit from constantly burning pilots. Turning the thermostat to the desired temperature is all that is required to put the unit in service.

Do not permit fans to blow directly at the unit. Wherever possible, avoid open windows next to the units' sides or back. Avoid wall type fans which create air cross-currents within a room.

It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system. Otherwise, a subnormal atmospheric pressure will occur, which will effect operation and cause undesirable working conditions.

A properly designed and installed hood will act as the heart of the ventilating system for the room or area in which the unit is installed and will leave the unit independent of changing draft conditions.

All valves must be checked and lubricated periodically. This must be done by an authorized service representative in your area.

OPERATING INSTRUCTIONS

Season Griddle:

Heat to low temperature (300 - 350 F/150-180C) and pour on a small amount of cooking oil, about one ounce (30cc) per square foot of surface. Spread the oil over the entire griddle surface with a cloth to create a thin film. Wipe off any excess oil with a cloth. Repeat this procedure 2 to 3 times until the griddle has a slick, mirror-like surface.

Operation:

Turn the burners on about 15-20 minutes before cooking for preheating. Set the knobs to the desired flame height (HMG). Each valve will control the gas flow to the burner to bring that area of the plate up to the set temperature. If different temperature settings are to be used, adjoining areas should be set at progressively higher temperatures using the lowest temperatures on the outside burners. A uniform and systematic approach to the loading of the griddle will produce the most consistent product results.

APW Wyott HMG-2448i - Operation: - 1

CAUTION: Do not turn on gas valves without lighting pilots. This could cause a build up of gas and potential explosion.

APW Wyott HMG-2448i - Operation: - 2

APW Wyott HMG-2448i - Operation: - 3

NOTICE: Due to heat transfer thru the griddle plate, adjoining zones can be no more than 25^ different.

APW Wyott HMG-2448i - Operation: - 4

CLEANING / MAINTENANCE

Initial Cleaning:

Prior to operating your new griddle, thoroughly wash the griddle surface and the exterior with a mild detergent or soap solution. Do not use abrasive cleaners since this might damage the cabinet finish. If the stainless steel surfaces become discolored, scrub by rubbing only in the direction of the finished grain.

Cleaning:

  1. Always turn unit off and allow it to cool completely before cleaning. Clean thoroughly before first use.
  2. After each use, clean the griddle with wire brush or flexible spatula.
  3. Once a day, thoroughly clean splash back, sides and front. Remove the grease drawer, empty it and wash it out.
  4. Once a week, clean the griddle surface thoroughly. If necessary, use a griddle stone, wire brush or steel wool on the surface. Rub with the grain of the metal while the griddle is still warm. A detergent may be used on the plate surface to help clean it; but, care must be taken to be sure the detergent is thoroughly removed. After removal of the detergent, the surface of the plate should then be covered with a thin film of oil to prevent rusting. Clean stainless surfaces with a damp cloth and polish with a soft dry cloth. To remove discoloration, use a nonabrasive cleaner. After each "weekly" cleaning, the griddle must be seasoned again. If the griddle usage is very high, the "weekly" cleaning procedures may be done more often than once a week.

Extended Shutdown:

Turn the manual shutoff valve to "OFF"; (field installed valve not supplied by the manufacturer); turn all control knobs to the "OFF" position; and shut off the pilot flame by turning the adjustment on the pilot valve.

*NOTE: Gas shutoff valve is supplied by the manufacturer on CE or European Community models.

If the griddle is to be shut down for an extended period, put a heavy coat of grease over the griddle plate.

SERVICE / REPAIR

NOTE: THIS APPLIANCE MUST ONLY BE SERVICED BY AN AUTHORIZED AGENT.

NOTE: Parts protected by the manufacturer or his agent are not to be adjusted by the installer unless the installer is an authorized service agent.

If you have any questions or problems contact your nearest APW Wyott Service Representative.

TROUBLESHOOTING GUIDE

PROBLEM POSSIBLE CAUSE
Heat does not come on when thermostat is turned on.Thermostat is bad.
Pilot burner not lit.
Gas valve is bad.
Pilot burner will not light.Obstructed pilot orifice.
Pilot gas turned off at automatic pilot.
Automatic pilot valve is bad.
Pilot burner will not stay lit.Thermocouple is bad.
Thermocouple is not hot enough.
Obstructed or wrong size pilot orifice.
Gas supply is not purged of air.
Air is blowing pilot light out.
Automatic pilot valve is bad.
Fat appears to smoke excessively.Heat is set too high.
Moisture in the food may be turning into steam.
Food sticks to griddle.Heat is set too high.
Griddle surface needs cleaning and/or seasoning.
Surface under food may not have been covered with enough cooking oil.
Food burned around edges or contains dark specks.Heat is set too high.
Griddle surface needs cleaning and/or seasoning.
Surface under food may not have been covered with enough cooking oil.
Food is undercooked inside.Heat is set too high.
Food may not have been cooked for long enough time.
Food tastes greasy or has objectionable off-flavor.Food itself may have off flavor.
Food may have been stored improperly before cooking.
Too much griddle fat used.
Heat is set too low.
Noticeable build-up of gum on griddle.Heat is set too high
Griddle surface needs cleaning and/or seasoning.
Too much griddle fat used.

HMG GRIDDLES (DOMESTIC) - EXPLODED VIEW & PARTS LIST
APW Wyott HMG-2448i - SERVICE / REPAIR - 1

text_image Technical diagram of a mechanical assembly with numbered components for identification and assembly reference.
ITEMP/NDESCRIPTIONHMG-2424iHMG-2436iHMG-2448iHMG-2460iHMG-2472i
122241254Weldm't,Weldm't,Griddle1Plate1
22241374Weldm't. Griddle Plate
22241494Weldm't. Griddle Plate1
22241614Weldm't. Griddle Plate1
22241734Weldm't. Griddle Plate1
221826433Side, Firebox22222
321826022Body, 24" Firebox1
21826122Body, 36" Firebox1
21826222Body, 48" Firebox1
21826322Body, 60" Firebox1
21826422Body, 72" Firebox1
421826017Support, Burner2
21826117Support, Burner2
21826217Support, Burner2
21826317Support,Burner
21826427Support,Burner
521826027Baffle,FrontHeat1
21826127Baffle, Front HeatHeat1
21826227Baffle, Front Heat1
21826327Baffle,FrontHeat
21826427Baffle,FrontHeat
621813085Spacer44556
721830725Manifold, 24"1
21830825Manifold, 36"1
21830925Manifold, 48"1
21831025Manifold, 60"1
21831125Manifold, 72"1
82068500Valve, Gas 210° On/Off23456
92092517Plug, 1/8 NPTM11111
102066834Hood, Orifice #3423456
112066851Hood, Orifice #5123456
122068002Valve, Pilot 90°12233
1321825113Bracket, Pilot12233
1421830712Burner, Pilot12233
152065846Burner Cast H23456
1622400010Support, Leg 24"2
22400015Support, Leg 36"2
22400020Support, Leg 48"2
22400025Support, Leg 60"2
22400030Support, Leg 72"2
1721826053Panel, Right & Left Side22222
1821825011Guide, Grease Slide22222
1921826052Panel Back 24"1
21826652Panel, Back 36"1
21826252Panel, Back 48"1
21826332Panel, Back 60"1
21826452Panel, Back 72"1
2022241253Panel, Control 24"1
22241373Panel, Control 36"1
22241493Panel, Control 48"1
22241613Panel, Control 60"1
22241733Panel, Control 72"1
212065849Venturi, Hvy Dty Griddles23456
222065916Gasket, Burner23456
232425310Pan, Grease 24"11111
248706300Knob, Metal Cookline .375 D Shaft, no Logo2345
258633700Leg, 2" Dia. Hvy Dty44444
262065839Adapter, 15° Angle Elbow23456
2722400003Brace, Leg22222
28*21826134Channel, StiflinerNA1
21826234Channel, Stifliner1
21826334Channel, Stifliner1
21826434Channel, Stifliner1
292067600Regulator, 5" WC. & 10" WC.11111
3021825012Side, Grease Chute22222
312065847APW Wyott Casted Logo11111
328861000Label, Spec11111
338809920Decal. Improper Installation11111
348837134Label, Orifice Size11111
358825300Decal, Leg11111
368837130Decal, Operating Instructions11111
3743813103Label, Hot Surface11111
3843813149Label, Hot Surface (French)11111
398835410Inst!Op Manual (N/S)11111

HMG GRIDDLES (CE) - EXPLODED VIEW & PARTS LIST
APW Wyott HMG-2448i - SERVICE / REPAIR - 2

text_image Technical diagram of a device assembly with numbered components and labeled parts, including a detailed detail view.
ITEMP/NDESCRIPTIONHMG-2424iHMG-2436iHMG-2448iHMG-2460iHMG-2472i
1 22241254Weldm't, Griddle Plate1
22241374Weldm't, Griddle Plate1
22241494Weldm't, Griddle Plate1
22241614Weldm't Griddle Plate1
22241734Weldm't, Griddle Plate1
221826433Side, Firebox22222
3 21826036Body, 24" Firebox1
21826136Body, 36" Firebox1
21826236Body, 48" Firebox1
21826336Body, 60" Firebox1
21826436Body, 72" Firebox1
421826017Support, Bumer2
21826117Support, Bumer2
21826217Support, Bumer2
21826317Support, Bumer2
21826417Support, Bumer2
5 21826037Baffle, Front Heat1
21826137Baffle, Front Heat1
21826237Baffle, Front Heat1
21826337Baffle, Front Heat1
21826437Baffle, Front Heat1
621813085Spacer44556
721830735Manifold, 24"1
21830835Manifold, 36"1
21830935Manifold, 48'1
21831035Manifold, 60"1
21831135Manifold, 72"1
82068300Valve. Gas 210° On/Off23456
92092517Plug, 1/8 NFTM11111
102066834Hood, Orifice #3423456
112066851Hopd, Orifice #5123456
121473700Thermocouple, CE Valve 600mm23456
1321826413Bracket, Pilot23456
1420932100Burner, Pilot23456
152065846Burner, Cast H23456
1622400010Support, Leg 24"2
22400015Support, Leg 36"2
22400020Support, Leg 48"2
22400025Support, Leg 60"2
22400030Support, Leg 72"2
1721826053Panel, Right & Left Side22222
1821825011Guide, Grease Slide22222
1921826052Panel, Back 24"1
21826652Panel, Back 36"1
21826252Panel, Back 48"1
21826332Panel, Back 60"1
21826452Panel, Back 72"1
2022243253Panel, Control 24" CE1
22243373Panel, Control 36" CE1
22243493Panel, Control 48" CE1
22243613Panel, Control 60" CE1
22243733Panel, Control 72" CE1
212065849Venturi, Hvy Dty Griddles23456
222065916Gasket, Burner23456
232425310Pan Grease 24"11111
248706300Knob, Metal Cookline .375 D Shaft23456
258633700Leg, 2" Dia, Hvy Dty44444
262065839Adapter, 15° Angle Elbow23456
2722400003Brace, Leg22222
2821826134Channel, Stiffiner Channel, Stiffiner Channel, Stiffiner Channel, StiffinerNA1
218262341
218263341
218264341
292067600Regulator, 5" W.C. & 10" W.C.11111
3021825012Side, Grease Chute22222
312065847APW Wyott Casted Logo11111
328861000Label, Spec11111
338809920Decal, Improper Installation11111
348837134Label, Orifice Size11111
358825300Decal, Leg11111
368837130Decal, Operating Instructions11111
3743813103Label, Hot Surface11111
3843813149Label, Hot Surface (French)11111
398835410Lnst/Op Manual (N/S)11111
402065884Ignitor23456
412065885Electrode, Spark23456
422069700Valve, Ball 3/4" 90°11111
432092612Elbow, Brass 3/8-27f x 3/8 C23456
442092614Elbow, Brass 3/8c x 3/8-27m Brass23456
452092626Pipe, Inlet11111
4620932101Nut, Compression & Ferrule23456
4721826016Bracket, Thermocouple23456
4821830817Tube, Pilot Supply CE23456
4921830847Tube, Orifice Supply23456
508806070Label, Delivery CE Gas Units (N/S)11111
518806075Label, Packaging CE Gas Units (N/s)11111
528806080Label, CE Ventilation (N/S)11111

NOTES:

NOTES:

APW WYOTT EQUIPMENT LIMITED WARRANTY

APW Wyatt Foodservice Equipment Company warrants it's equipment against defects in materials and workmanship, subject to the following conditions:

This warranty applies to the original owner only and is not assignable.

Should any product fail to function in its intended manner under normal use within the limits defined in this warranty, at the option of APW Wyatt such product will be repaired or replaced by APW Wyatt or its Authorized Service Agency. APW Wyatt will only be responsible for charges incurred or service performed by its Authorized Service Agencies. The use of other than APW Wyatt Authorized Service Agencies will void this warranty and APW Wyatt will not be responsible for such work or any charges associated with same. The closest APW Wyatt Authorized Service Agent must be used.

This warranty covers products shipped into the 48 contiguous United States, Hawaii, metropolitan areas of Alaska and Canada. There will be no labor coverage for equipment located on any island not connected by roadway to the mainland.

Warranty coverage on products used outside the 48 contiguous United States, Hawaii, and metropolitan areas of Alaska and Canada may vary. Contact the international APW Wyott distributor, dealer, or service agency for details.

Time Period

One year for parts and one year for labor, effective from the date of purchase by the original owner. The Authorized Service Agency may, at their option, require proof of purchase. Parts replaced under this warranty are warranted for the un-expired portion of the original product warranty only.

Exceptions

*Gas/Electric Cookline: Models GCB, GCRB, GF, GGM, GGT, CHP-H, EF, EG, EHP. Three (3) Year Warranty on all component parts, except switches and thermostats. (2 additional years on parts only. No labor on second or third year
*Broiler Briquettes, Rock Grates, Cooking Grates, Burner Shields, Fireboxes:90 Day Material Only. No Labor.
*Heat Strips: Models FD, FDL, FDD, FDDL. Two (2) Year Warranty on element only. No labor second year.
*Glass Windows, Doors, Seals, Rubber Seals, Light Bulb: Day Material Only. No Labor.

In all cases, parts covered by extended warranty will be shipped FOB the factory after the first year.

Portable Carry In Products

Equipment weighing over 70 pounds or permanently installed will be serviced on-site as per the terms of this warranty. Equipment weighing 70 pounds or under, and which is not permanently installed, i.e. with cord and plug, is considered portable and is subject to the following warranty handling limitations. If portable equipment fails to operate in its intended manner on the first day of connection, or use, at APW Wyatt's option or its Authorized Service Agency, it will be serviced on site or replaced.

From day two through the conclusion of this warranty period, portable units must be taken to or sent prepaid to the APW Wyatt Authorized Service Agency for in-warranty repairs. No mileage or travel charges are allowed on portable units after the first day of u If the customer wants on-site service, they may receive same by paying the travel and mileage charges. Exceptions to this rule: (1) countertop warmers and cookers, which are covered under the Enhanced Warranty Program, and (2) toasters or rollergrills which have in store service.

Exclusions

The following conditions are not covered by warranty:

*Equipment failure relating to improper installation, improper utility connection or supply and problems due to ventilation.

*Equipment that has not been properly maintained, calibration of controls, adjustments, damage from improper cleaning and water damage to controls.

*Equipment that has not been used in an appropriate manner, or has been subject to misuse or misapplication, neglect, abuse, accident, alteration, negligence, damage during transit, delivery or installation, fire, flood, riot or act of god.

*Equipment that has the model number or serial number removed or altered.

If the equipment has been changed, altered, modified or repaired by other than an Authorized Service Agency during or after the warranty period, then the manufacturer shall not be liable for any damages to any person or to any property, which may result from use of the equipment thereafter.

This warranty does not cover services performed at overtime or premium labor rates. Should service be required at times which normally involve overtime or premium labor rates, the owner shall be charged for the difference between normal service rates and su premium rates. APW Wyott does not assume any liability for extended delays in replacing or repairing any items beyond its control.

In all cases, the use of other than APW Wyott Authorized OEM Replacement Parts will void this warranty.

This equipment is intended for commercial use only. Warranty is void if equipment is installed in other than commercial application

Water Quality Requirements

Water supply intended for a unit that has in excess of 3.0 grains of hardness per gallon (GPG) must be treated or softened before being used. Water containing over 3.0 GPG will decrease the efficiency and reduce the operation life of the unit.

Note: Product failure caused by liming or sediment buildup is not covered under warranty.

"THE FOREGOING WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSES AND CONSTITUTES THE ENTIRE LIABILITY OF APW WYOTT. IN NO EVENT DOES THE LIMITED WARRANTY EXTEND BEYOND THE TERMS STATED HEREIN."

9/05

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : APW Wyott

Model : HMG-2448i

Category : Grill