LS-J0964HL - Air-conditioner LG - Free user manual and instructions
Find the device manual for free LS-J0964HL LG in PDF.
User questions about LS-J0964HL LG
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air-conditioner in PDF format for free! Find your manual LS-J0964HL - LG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LS-J0964HL by LG.
USER MANUAL LS-J0964HL LG
Room Air Conditioner OWNER'S MANUAL
- Please read carefully and thoroughly this manual before operating this unit.
Contact the authorized SVC man for repair or maintenance of this unit.
installer for installation of this unit.
this is not intended for use by young persons without supervision.
and be supervised to ensure with the appliance.

text_image
Manual before operating this unit. Contact the authorized SVC man for re snance of this unit. the installer for installation of the is not intended for use be persons without super and be supervised to with the appliance on, the condition submit approval by e which is electric -3 Noron, the conditioning
submit the approval by the which the electricity
3-3 Nor
Safety Precautions
Warning 2
Caution 3
Operating Instructions
Preparation before operation ..4
Remote Control Features ....5
Operation Mode Selection .....7
Additional features 13
Care and Maintenance
Care and Maintenance ..... 16
Operation Tips 18
Troubles, meeting this
Before You
Call For Service 19
Safety precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
■ Incorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is classified by the following indications.

WARNING
This symbol indicates the possibility of death or serious injury.

CAUTION
This symbol indicates the possibility of injury or damage to properties only.

WARNING
■ Do not install, remove and reinstall the unit by yourself.
- Improper installation will cause water leakage, electrical shock, or fire. Please consult authorized dealer or specialist for the installation work. Please note fault caused by improper installation is not covered by warranty.
- Unit must be installed in an easily accessible area. Any additional cost required to hire a special equipment to service the unit will be the responsibility of the customer.

WARNING
• Otherwise, it will cause electrical shock or fire due to heat generation.
• It will cause electrical shock or fire due to heat generation.
• This could damage your health.
• It will cause electrical shock or fire due to heat generation.
• It may cause electrical shock.
- If the unit continues to be operated in an abnormal condition, it may cause a fire, damage, etc. In this case, consult your dealer.
• It will cause electrical shock or fire.
• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
• Since the fan rotates at high speed, this may cause an injury or damage the unit.
• If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.
CAUTION
- Contact the authorized Service technician for repair or maintenance of this unit.
- Contact the installer for installation of this unit.
- The air conditioner is not intended for use by young children or infirm persons without supervision.
- Young children should be supervised to ensure that they do not play with the air conditioner.

CAUTION

natural_image
Completely blank or uniformly gray image with no visible content, text, or symbols.• It may cause an injury.
- Should be disconnected from supply

natural_image
Solid dark gray image with no visible content, text, or symbols.• Water may enter the unit and degrade the insulation. It may cause an electric shock.

natural_image
Solid gray image with no visible content, text, or symbols.• An oxygen shortage may occur.

natural_image
Completely blank or uniformly gray image with no visible content, text, or symbols.• Since the fan rotates at high speed during operation, it may cause an injury.

natural_image
Solid dark gray image with no visible content, text, or symbols.• This could injure the pet or plant.

natural_image
Solid dark gray image with no visible content, text, or symbols.• The unit may drop or fall down and cause an injury.

natural_image
Solid gray image with no visible content, text, or symbols.- It may cause a fire or deformation of the cabinet.

natural_image
Solid gray image with no visible content, text, or symbols.• It may affect combustion.

natural_image
Solid gray image with no visible content, text, or symbols.• It may cause an injury through dropping or falling down.

natural_image
Solid gray image with no visible content, text, or symbols.• It will cause an injury by the rotating blower.

natural_image
Solid dark gray image with no visible content, text, or symbols.• If not, dirt may collect and cause a fire.

natural_image
Completely blank or uniformly gray image with no visible content, text, or symbols.• It may cause an injury, etc. by falling down.

natural_image
Solid gray image with no visible content, text, or symbols.- Do not use this air conditioner to preserve precision devices, food, animal, plants, and art objects. It may cause deterioration of quality, etc.

natural_image
Solid dark gray image with no visible content, text, or symbols.• In the cooling mode, if it is operated in a room with high humidity (80%RH or more) for a long time, water condensed in the air conditioner may drop and may wet and spoil furniture, etc.
Preparation before operation
How to Insert the Batteries
Remove the battery cover by pulling it according to the arrow direction.
2 Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
3 Reattach the cover by sliding it back into position.
NOTES:
- Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries

natural_image
Illustration of four hands using a tool to adjust or install a component, shown in circular frames with arrows indicating motion (no text or symbols present)Storage and Tips For Using the Remote Control
- The remote control may be stored mounted on a wall.
• To operate the room air conditioner, aim the remote control at the signal receptor.

flowchart
graph TD
A["Hand holding a screwdriver"] --> B["Insert the phone into a device"]
B --> C["Take down to press, then to install the phone"]
C --> D["Take down to press again, then to install the phone"]

natural_image
Line drawing of a wall-mounted air conditioner with a coiled cable (no text or symbols)Signal Receptor
Receives the signals from the remote control. (Signal receiving sound: two short beeps or one long beep.)
Operation Indication Lamps
| 1 | On/Off | : Lights up during the system operation. |
| Sleep Mode | : Lights up during Sleep Mode Auto operation. | |
| Timer | : Lights up during Timer operation. | |
| Defrost Mode | : Lights up during Defrost Mode or Hot Start operation (Heat pump model only) |
OUT OUTDOOR UNIT : Lights up during outdoor unit operation. DOOR OPERATION (Cooling model only)

text_image
Signal receptor Operation indication lampsAbout the remote control on the system
The remote control transmits the signals to the system.

Features of the Remote Control- Door Closed

text_image
88°C TIME TIME 18:88 18:88 18:88 Flip-up door (closed)
START/STOP BUTTON
Operation starts when this button is pressed and stops when the button is pressed again.

OPERATION MODE SELECTION BUTTON
Used to select the operation mode.

ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.

INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps low, medium, high, or CHAOS.

JET COOL
Used to start or stop the speed cooling. (Speed cooling operates super high fan speed in cooling mode.)

CHAOS SWING BUTTON
Used to stop or start louver movement and set the desired up/down airflow direction.






Operation Mode

flowchart
graph TD
A["Cooling Operation"] --> B["Auto Operation"]
B --> C["Healthy Dehumidification Operation"]
style A fill:#f9f,stroke:#333
style B fill:#f9f,stroke:#333
style C fill:#f9f,stroke:#333

flowchart
graph TD
A["Cooling Operation"] --> B["Auto Operation"]
B --> C["Healthy Dehumidification Operation"]
C --> D["Heating Operation"]
style A fill:#f9f,stroke:#333
style B fill:#f9f,stroke:#333
style C fill:#f9f,stroke:#333
style D fill:#f9f,stroke:#333

Features of the Remote Control- Door Opened

text_image
Signal transmitter ON- OFF SET- CANCEL PLASMA RESETON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation.
TIME SETTING BUTTONS
Used to adjust the time. (See page 13)
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 13)
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation. (See page 13)
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating (turns indoor fan on/off).
(See page 14)
ROOM TEMPERATURE
Used to check the room temperature.
PLASMA
Used to start or stop the plasma-purification function. (See page 12)
HORIZONTAL AIRFLOW
Used to set the desired horizontal airflow direction. (See page 14)
RESET BUTTON
Used prior to resetting time or after replacing batteries.
CHECKING BUTTON
DIRECTION CONTROL BUTTON (NOT ON ALL MODELS)
How to use the Operation Mode Selection button

Cooling Operation

flowchart
graph TD
A["1 Press the Start/Stop button.<br>The unit will respond with a beep."] --> B["2 Open the door on the remote control. To select Cooling Operation, press the Operation Mode Selection button.<br>Each time the button is pressed, the operation mode is shifted in the direction of the arrow."]
B --> C["3 Close the door on the remote control. Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C in 1°C increments.<br>To raise the temperature<br>To lower the temperature"]
C --> D["4 Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps-low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted."]
Natural wind by the CHAOS logic
☐ For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.

Auto Operation

flowchart
graph TD
A["1 Press the Start/Stop button.<br>The unit will respond with a beep."] --> B["2 Open the door on the remote control. To select Auto Operation, press the Operation Mode Selection button.<br>Each time the button is pressed, the operation mode is shifted in the direction of the arrow."]
B --> C["3 The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you want to change the set temperature, close the door on the remote control and press the Room Temperature Setting buttons. The cooler or warmer you feel, the more times (up to two times) you should press the button. The set temperature will then be changed automatically."]
During Auto Operation:
☐ You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.
☐ If the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating to cooling, it must be done by manually resetting.
☐ During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and down automatically. If you want to stop auto-swing, press the chaos swing button again.

Healthy Dehumidification Operation

flowchart
graph TD
A["1 Press the Start/Stop button.<br>The unit will respond with a beep."] --> B["2 Open the door on the remote control. To select Healthy Dehumidification Operation, press the Operation Mode Selection button.<br>Each time the button is pressed, the operation mode is shifted in the direction of the arrow."]
B --> C["3 Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps-low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted."]
C --> D["Natural wind by the CHAOS logic<br>☐ For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic."]
During Healthy Dehumidification Operation:
☐ If you select the dehumidification mode on the operation selection button, the A/C starts to run the dehumidification function, automatically setting the room temp. and airflow volume to the best condition for dehumidification based on the sensed current room temp.
In this case, however, the setting temp. is not displayed in the remote control and you are not able to control the room temp. either.
☐ During the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temp. status and makes the room condition healthy and comfortable even in the high humidity season.

Heating Operation(Heat pump model only)

flowchart
graph TD
A["1 Press the Start/Stop button.<br>The unit will respond with a beep."] --> B["2 Open the door on the remote control. To select Heating Operation, press the Operation Mode Selection button.<br>Each time the button is pressed, the operation mode is shifted in the direction of the arrow."]
B --> C["3 Close the door on the remote control.<br>Set the temperature higher than the room temperature.<br>The temperature can be set within a range of 16°C~30°C in 1°C increments.<br>To raise the temperature<br>To lower the temperature"]
C --> D["4 Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps-low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted."]
Natural wind by the CHAOS logic
☐ For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.

Jet Cool Operation

text_image
Po JET1
Press the Start/Stop button. The unit will respond with a beep.

natural_image
Hand icon pointing at a button with a circled number 1 (no text or symbols)2
Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes.

3
To cancel the Jet Cool mode, press the Jet Cool button again or the fan speed button or the room temperature setting button and the unit will operate in high fan speed on cooling mode.

text_image
Diagram illustrating three finger states: pointing at a target, moving a ball with a 'or' button, and interacting with a target icon.NOTE:
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18^ . It is especially used to cool the room temp. in the shortest time in a hot summer.
In heat pump mode or neuro fuzzy mode however, the JET COOL function is not available.
☐ In order to return to the normal cooling mode from the JET COOL mode, you just press either the operation mode selection button, airflow volume selection or temp. setting button or the JET COOL button again.

PLASMA Purification Operation(Option)

text_image
PLASMA 18°C PLASMA1 Press the Start/Stop button. The unit will respond with a beep.

2 Open the door on the remote control. Press the PLASMA air purifying operation ON/OFF button. Operation will start when the button is pressed and stop when the button is pressed again.

3 Set the fan speed again with door of the remote control closed. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
* Air purifying operation (PLASMA) with cooling, Heating or any other operations.

PLASMA Air Purifying Operateion only

text_image
PLASMAIf you press the only PLASMA button, PLASMA air purifying operates only.
Then, fan speed is low. You can select the fan speed in four steps-low, medium, high or CHAOS.
Each time the button ( ) is pressed, the fan speed mode is shifted.

Sleep Mode

Press the Sleep Mode Auto button to set the time you want the unit to turn off automatically.


The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times.
The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner.

Make sure the Sleep Mode Auto LED lights up.
To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star (☆) disappears from the operation display.
Note: The Sleep Mode will be operated at low fan speed (cooling) or medium fan speed (heat pump only) for quiet sleeping.
IN COOLING MODE: The temperature will automatically rise by 1°C over the next 30 minutes and by 2°C in 1 hour for comfortable sleeping.

Setting the Time

Time can be set only when you have pressed the Reset button. If you have just replaced the batteries, the Reset button should be pressed to reset the time.
Press the Start/Stop button.


Press the Time Setting buttons until the desired time is set.


Press the Timer SET button.
Note: Check the indicator for A.M. and P.M.


Delay Start/Pre-Set Stop

Make sure the time is set correctly on the remote control display.

Press the ON/OFF Timer buttons to turn Timer on or off.


Press the Time Setting buttons until the desired time is set.


Press the selected on/off setting by pressing the Timer SET button while aiming the remote control at the signal receptor.

To cancel the setting the timer.

Press the Timer Cancel button while aiming remote control at the signal receptor.
(The timer lamp on the air conditioner and the display will go out.)
NOTE: Select one of the following four types of operation.
with the unit running

Delay OFF Timer

Delay ON Timer

Delay OFFand ON Timer

Delay ONand OFF Timer
Vertical Airflow Direction Control

The up/down airflow (Vertical Airflow) can be adjusted by using the remote control.

natural_image
Diagram of a rectangular object with a curved arrow indicating direction, no text or symbols presentPress the Start/Stop button to start the unit.
Open the door on the remote control.
Press Chaos Swing button and the louvers will swing up and down. Press the Chaos Swing button again to set the vertical louver at the desired airflow direction.

Note:
☐ If you press the CHAOS swing button, the horizontal airflow direction is changed automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable, as if enjoying a natural breeze.
□ Always use the remote control to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand could damage the air conditioner.
☐ When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system.
To adjust left/right(Horizontal Airflow) direction
Caution : Ensure unit is turned
off before adjusting the horizontal airflow direction control. Carefully open vertical louver to allow access to the horizontal airflow direction.

natural_image
Diagram of a car air conditioner unit with airflow arrows indicating movement (no text or symbols)Adjust the left/right airflow direction by hand.

Horizontal Airflow Direction Control (Option)
The left/right(Horizontal Airflow) can be adjusted by using the remote control.
Press the Start/Stop button to start the unit.
Open the door on the remote control. Press the Airflow Direction Start/Stop button and the louvers will swing left and right. Press the Horizontal Airflow Direction Control Button again to set the horizontal louver at the desired airflow direction.

natural_image
Illustration of a hand pressing a button on a wall-mounted air conditioner (no text or symbols)
Air Circulation Mode
Circulates the room air without cooling or heating.

Press the Start/Stop button. the unit will respond with a beep.

Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS and back to low again.


flowchart
graph LR
A["Stage 1: Battery"] --> B["Stage 2: Charge +"]
B --> C["Stage 3: Voltage +"]
C --> D["Stage 4: Charge +"]
D --> E["Stage 5: Charge +"]
CHAOS Air
Note:
☐ CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.

Slide Switch Operation
FORCED OPERATION
Operation procedures when the remote control can't be used.
Open the front panel upward and move the Slide Switch to the Forced Operation position.
If you want to stop operation, move the Slide Switch to the Auto Restart or the Remote Control position.
In case the power comes on again after power failure on the Forced Operation position, the operating conditions are automatically set as follows:
During Forced Operation, the initial mode continues.

text_image
Slide Switch Open the front panel upward
text_image
Slide Switch FORCED OPERATION AUTO RESTART REMOTE CONTROL| Cooling Model | Heat pump Model | |||
| Room Temp. ≥ 24°C | 21°C Room Temp. < 24°C | Room Temp. < 21°C | ||
| Operating mode | Cooling | Cooling | Healthy Dehumidification | Heating |
| Indoor FAN Speed | High | High | Healthy Dehumidification Rule | High |
| Setting Temperature | 22°C | 22°C | 23°C | 24°C |
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.
If you want to use this operation, Open the front panel upward and move the slide switch to the Auto Restart position.
If you do not want to use this operation, move the Slide Switch to the Remote Control position.

text_image
Slide Switch Open the front panel upward
text_image
Slide Switch FORCED OPERATION AUTO RESTART REMOTE CONTROLWhen you are out for a while, put the Slide Switch on the Remote Control.
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed.
High fan speed is recommended when you wish to cool the room quickly.

text_image
High SpeedCare and maintenance of the air conditioner
CAUTION: Before performing any maintenance, turn off the main power to the system.
Indoor Unit
Grille, Case, and Remote Control
☐ Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
NOTE:
Supply power must be disconnected before cleaning the indoor unit.

text_image
Air inlet vent Air outlet vent Vertical louver Horizontal louver Air filters (behind front panel)AIR FILTERS
The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if necessary

natural_image
Diagram of a car air conditioner unit with cooling fins and airflow direction indicators (no text or labels)PLASMA FILTER, DEODORIZER FILTER(OPTION)
The PLASMA filter behind the air filters should be checked and cleaned once every 3 months or more often if necessary.

text_image
DEODORIZER Filter PLASMA Filter
Don't touch this PLASMA Filter within 10 seconds after opening the inlet grille, it may cause an electric shock.
□ Never use any of the followings:
• Water hotter than 40°C Could cause deformation and/or discoloration.
• Volatile substances
Could damage the surfaces of the air conditioner.

text_image
Buzer Pradette Gasoline- Lift the front access panel and pull the filter tab slightly forward to remove the filter.
- Clean the filter with a vacuum or warm, soapy water.
• If dirt is conspicuous, wash with a solution of detergent in lukewarm water.
- If hot water (40°C or more) is used, it may be deformed.
After washing with water, dry well in the shade.
Re-install the air filter.
After removing the air filters, pull slightly forward to remove the PLASMA filter.
Dip the PLASMA filter into the water mixed with neutral detergent, for 20\~30 minutes.
Dry the PLASMA filter in the shade for a day (Especially, the humidity must be removed perfectly on this parts).
Note the cuts of electric discharge lines.
● Re-install the PLASMA filter to the original position.
After removing the air filters, pull slightly forward to remove the DEODORIZER filter.
Dry in the sunlight for tow hours.
Re-install the DEODORIZER filter to the original position.
Replacement of Purifying Filter(Option)
• Recommended use period : About 2 years
Open front panel and remove air filters.

text_image
Air filter- Remove air purifying filters.
Insert new air purifying filters.

natural_image
Diagram of an air conditioner unit showing internal structure and airflow direction (no text or labels)Reinsert air filters and close front panel.

natural_image
Technical illustration of a car air conditioner unit with cooling fins and heat exchangers (no text or symbols)
natural_image
Technical line drawing of a mechanical component with internal channels and mounting brackets (no text or symbols)Air purifying filter
Outdoor Unit
The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. Air in vent
NOTE:
Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.

text_image
gged Air intake vents (Side) (Rear) Air outlet vents Piping Drain Hose
text_image
Air intake vents (Side) Air outlet vents (Rear) Piping Drain Hose
text_image
Air intake vents (Side) (Air outlet vents) (Rear) Piping Drain HoseWhen the air conditioner is not going to be used for a long time.
When air conditioner is not going to be used for a long time.

Operate the air conditioner on Air circulation mode (Refer to page 14) for 2 to 3 hours.
• This will dry out the internal mechanisms.

Turn off the circuit breaker, and disconnect the plug.

Turn off the circuit breaker when the air conditioner is not going to be used for a long time.
Dirt may collect and may cause a fire.

Remove the batteries from the remote control.
When the air conditioner is to be used again.

Clean the air filter and install it in the indoor unit.
(Refer to page 16 for cleaning filters.)

Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
Operation Tips
This is not good for the health and wastes electricity.
Avoid opening doors and windows as much as possible to keep the cool air in the room.
Do not let direct sunshine enter the room when the air conditioner is in operation.
Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects. Clean at least once every two weeks.
Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room.
Since windows are kept closed, it is a good idea to open them and ventilate the room now and then.

Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or service center.
| Case | Explanation | See page |
| The air conditioner does not operate. | Have you made a mistake in timer operation? | 13 |
| Has the fuse blown or has the circuit breaker been tripped? | - | |
| The room has a peculiar odor. | Check that this is not a damp smell exuded by the walls, carpet, furniture, or cloth items in the room. | - |
| It seems that condensation is leaking from the air conditioner. | Condensation occurs when the airflow from the air conditioner cools the warm room air. | - |
| Air conditioner does not operate for about 3 minutes when restarted. | This is the protector of the mechanism.Wait about three minutes and operation will begin. | - |
| Does not cool or heat effectively. | Is the air filter dirty? See air filter cleaning instructions. | 16 |
| Has the temperature been set incorrectly? | 7, 10 | |
| Are the indoor unit's air inlet or outlet vents obstructed? | - | |
| The air conditioner operation is noisy. | For a noise that sounds like water flowing.-This is the sound of freon flowing inside the air conditioner unit.For a noise that sounds like the compressed air releasing into atmosphere.-This is the sound of the dehumidifying water being processed inside the air conditioning unit. | - |
| Remote control display is faint, or no display at all. | Are the batteries depleted?Are the batteries inserted in the opposite (+) and (-) directions? | 4 |
| Crack sound is heard. | This sound is generated by the expansion/constriction of the front panel, etc. due to changes of temperature. | - |
NOTE
WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT.
The indoor side is not water resistant and should not be exposed to excess water.