USER MANUAL LS-K2662CL LG

Room Air Conditioner OWNER'S MANUAL

  • Please read carefully and thoroughly this manual before operating this unit.
  • Contact the authorized SVC man for repair or maintenance of this unit.
  • Contact the installer for installation of this unit.
    • The appliance is not intended for use by young children or infirm persons without supervision.
  • Young children should be supervised to ensure that they do not play with the appliance.

Prior to installation of air-conditioning unit must be submitted or approved by the utility service which provides electricity (EN 60555-3 No. 2)

LG LS-K2662CL - Room Air Conditioner OWNER'S MANUAL - 1

text_image Safety Precautions Warning ....2 Caution ....3 Operating Instructions Preparation before operation ..4 Remote Control Features ....5 Operation Mode Selection ....7 Additional features ....13 Care and Maintenance Care and Maintenance ....16 Operation Tips ....18 Troubles Before You Call For Service ....19

Safety precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

■ Incorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is classified by the following indications.

LG LS-K2662CL - Safety precautions - 1

WARNING

LG LS-K2662CL - WARNING - 1

This symbol indicates the possibility of death or serious injury.

LG LS-K2662CL - WARNING - 2

CAUTION

LG LS-K2662CL - CAUTION - 1

This symbol indicates the possibility of injury or damage to properties only.

LG LS-K2662CL - CAUTION - 2

WARNING

■ Do not install, remove and reinstall the unit by yourself.

  • Improper installation will cause water leakage, electrical shock, or fire. Please consult authorized dealer or specialist for the installation work. Please note fault caused by improper installation is not covered by warranty.
  • Unit must be installed in an easily accessible area. Any additional cost required to hire a special equipment to service the unit will be the responsibility of the customer.

LG LS-K2662CL - WARNING - 1

WARNING

LG LS-K2662CL - WARNING - 1

• Otherwise, it will cause electrical shock or fire due to heat generation.

LG LS-K2662CL - WARNING - 2

• It will cause electrical shock or fire due to heat generation.

LG LS-K2662CL - WARNING - 3

• It will cause electrical shock or fire.
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

LG LS-K2662CL - WARNING - 4

• It will cause electrical shock or fire due to heat generation.

LG LS-K2662CL - WARNING - 5

• It may cause electrical shock.

LG LS-K2662CL - WARNING - 6

• Since the fan rotates at high speed, this may cause an injury or damage the unit.

LG LS-K2662CL - WARNING - 7

• This could damage your health.

LG LS-K2662CL - WARNING - 8

- If the unit continues to be operated in an abnormal condition, it may cause a fire, damage, etc. In this case, consult your dealer.

LG LS-K2662CL - WARNING - 9

• If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.

LG LS-K2662CL - WARNING - 10

LG LS-K2662CL - WARNING - 11

CAUTION

  • Contact the authorized Service technician for repair or maintenance of this unit.
  • Contact the installer for installation of this unit.
  • The air conditioner is not intended for use by young children or infirm persons without supervision.
  • Young children should be supervised to ensure that they do not play with the air conditioner.

CAUTION

LG LS-K2662CL - CAUTION - 1

• It may cause an injury.
- Should be disconnected from supply
- Since the fan rotates at high speed during operation, it may cause an injury.

LG LS-K2662CL - CAUTION - 2

LG LS-K2662CL - CAUTION - 3

• It may cause a fire or deformation of the cabinet.

LG LS-K2662CL - CAUTION - 4

- It will cause an injury by the rotating blower.

LG LS-K2662CL - CAUTION - 5

- Do not use this air conditioner to preserve precision devices, food, animal, plants, and art objects. It may cause deterioration of quality, etc.

LG LS-K2662CL - CAUTION - 6

• Water may enter the unit and degrade the insulation. It may cause an electric shock.

LG LS-K2662CL - CAUTION - 7

• This could injure the pet or plant.

LG LS-K2662CL - CAUTION - 8

- It may affect combustion.

LG LS-K2662CL - CAUTION - 9

• If not, dirt may collect and cause a fire.

LG LS-K2662CL - CAUTION - 10

- In the cooling mode, if it is operated in a room with high humidity (80%RH or more) for a long time, water condensed in the air conditioner may drop and may wet and spoil furniture, etc.

LG LS-K2662CL - CAUTION - 11

• An oxygen shortage may occur.

LG LS-K2662CL - CAUTION - 12

• The unit may drop or fall down and cause an injury.

LG LS-K2662CL - CAUTION - 13

• It may cause an injury through dropping or falling down.

LG LS-K2662CL - CAUTION - 14

- It may cause an injury, etc. by falling down.

Preparation before operation

How to Insert the Batteries

Remove the battery cover by pulling it according to the arrow direction.
2 Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
3 Reattach the cover by sliding it back into position.

NOTES:

- Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries.

LG LS-K2662CL - NOTES: - 1

natural_image Illustration of four hand positions showing a tool manipulation step (no text or symbols)

Storage and Tips For Using the Remote Control

- The remote control may be stored mounted on a wall.

• To operate the room air conditioner, aim the remote control at the signal receptor.
- The remote control will operate the air conditioner at a distance of up to 7m.

LG LS-K2662CL - Storage and Tips For Using the Remote Control - 1

flowchart
graph TD
    A["User Pen/USB"] --> B["Insert Phone"]
    B --> C["Device with Display"]
    C --> D["Device with Display"]
    D --> E["Device with Display"]

LG LS-K2662CL - Storage and Tips For Using the Remote Control - 2

natural_image Illustration of a car air conditioner with a cable inserted, showing grille and handle (no text or symbols)

Signal Receptor

Receives the signals from the remote control. (Signal receiving sound: two short beeps or one long beep.)

Operation Indication Lamps

LG LS-K2662CL - Operation Indication Lamps - 1

On/Off : Lights up during the system operation.

LG LS-K2662CL - Operation Indication Lamps - 2

Sleep Mode : Lights up during Sleep Mode Auto operation.

LG LS-K2662CL - Operation Indication Lamps - 3

Timer : Lights up during Timer operation.

LG LS-K2662CL - Operation Indication Lamps - 4

Defrost Mode : Lights up during Defrost Mode or Hot Start operation (Heat pump model only)

OUT OUTDOOR UNIT : Lights up during outdoor unit operation. DOOR OPERATION (Cooling model only)

LG LS-K2662CL - Operation Indication Lamps - 5

text_image Signal receptor Operation indication lamps

About the remote control on the system

The remote control transmits the signals to the system.

LG LS-K2662CL - About the remote control on the system - 1

Features of the Remote Control- Door Closed

LG LS-K2662CL - Features of the Remote Control- Door Closed - 1

text_image 转电▲○灯+ 88℃ TIME TIME 16:00 温润 5W Flip-up door (closed)

LG LS-K2662CL - Features of the Remote Control- Door Closed - 2

START/STOP BUTTON

Operation starts when this button is pressed and stops when the button is pressed again.

LG LS-K2662CL - START/STOP BUTTON - 1

OPERATION MODE SELECTION BUTTON

Used to select the operation mode.

LG LS-K2662CL - OPERATION MODE SELECTION BUTTON - 1

ROOM TEMPERATURE SETTING BUTTONS

Used to select the room temperature.

LG LS-K2662CL - ROOM TEMPERATURE SETTING BUTTONS - 1

INDOOR FAN SPEED SELECTOR

Used to select fan speed in four steps low, medium, high, or CHAOS.

LG LS-K2662CL - INDOOR FAN SPEED SELECTOR - 1

JET COOL

Used to start or stop the speed cooling. (Speed cooling operates super high fan speed in cooling mode.)

LG LS-K2662CL - JET COOL - 1

CHAOS SWING BUTTON

Used to stop or start louver movement and set the desired up/down airflow direction.

LG LS-K2662CL - CHAOS SWING BUTTON - 1

LG LS-K2662CL - CHAOS SWING BUTTON - 2

LG LS-K2662CL - CHAOS SWING BUTTON - 3

LG LS-K2662CL - CHAOS SWING BUTTON - 4

LG LS-K2662CL - CHAOS SWING BUTTON - 5

LG LS-K2662CL - CHAOS SWING BUTTON - 6

Operation Mode
LG LS-K2662CL - CHAOS SWING BUTTON - 7

flowchart
graph TD
    A["Cooling Operation"] --> B["Auto Operation"]
    B --> C["Healthy Dehumidification Operation"]
    D["A"] --> A
    E["*"] --> A

(Cooling Model)

LG LS-K2662CL - CHAOS SWING BUTTON - 8

flowchart
graph TD
    A["Cooling Operation"] --> B["Auto Operation"]
    B --> C["Healthy Dehumidification Operation"]
    C --> D["Heating Operation"]
    D --> A

(Heat Pump Model)

LG LS-K2662CL - CHAOS SWING BUTTON - 9

LG LS-K2662CL - CHAOS SWING BUTTON - 10

Features of the Remote Control- Door Opened

LG LS-K2662CL - Features of the Remote Control- Door Opened - 1

text_image Signal transmitter ON- OFF SET- CANCEL PLASMA RESET

ON/OFF TIMER BUTTONS

Used to set the time of starting and stopping operation.

TIME SETTING BUTTONS

Used to adjust the time. (See page 13)

TIMER SET/CANCEL BUTTONS

Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 13)

SLEEP MODE AUTO BUTTON

Used to set Sleep Mode Auto operation. (See page 13)

AIR CIRCULATION BUTTON

Used to circulate the room air without cooling or heating (turns indoor fan on/off). (See page 14)

ROOM TEMPERATURE

CHECKING BUTTON

Used to check the room temperature.

PLASMA(OPTION)

Used to start or stop the plasma-purification function. (See page 12)

RESET BUTTON

Used prior to resetting time or after replacing batteries.

How to use the Operation Mode Selection button

LG LS-K2662CL - How to use the Operation Mode Selection button - 1

Cooling Operation

LG LS-K2662CL - Cooling Operation - 1

flowchart
graph TD
    A["18°C Start/Stop Button"] --> B["Press the Start/Stop button. The unit will respond with a beep."]
    B --> C["2 Open the door on the remote control. To select Cooling Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow."]
    C --> D["3 Close the door on the remote control. Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C in 1°C increments."]
    D --> E["4 Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps-low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted."]

Safety Precautions

Operating Instructions

Care and Maintenance

Troubleshooting Tips

Natural wind by the CHAOS logic

☐ For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.

LG LS-K2662CL - Natural wind by the CHAOS logic - 1

Auto Operation

LG LS-K2662CL - Auto Operation - 1

text_image 单A6位

1

Press the Start/Stop button. The unit will respond with a beep.

LG LS-K2662CL - 1 - 1

2

Open the door on the remote control. To select Auto Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

LG LS-K2662CL - 2 - 1

LG LS-K2662CL - 2 - 2

text_image 18°C Cooling Healthy Dehumidification (Heat pump model only) 30°C

3

The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you want to change the set temperature, close the door on the remote control and press the Room Temperature Setting buttons. The cooler or warmer you feel, the more times (up to two times) you should press the button. The set temperature will then be changed automatically.

LG LS-K2662CL - 3 - 1

During Auto Operation:

☐ You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.
☐ If the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating to cooling, it must be done by manually resetting.
☐ During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and down automatically. If you want to stop auto-swing, press the chaos swing button again.

LG LS-K2662CL - During Auto Operation: - 1

LG LS-K2662CL - During Auto Operation: - 2

Healthy Dehumidification Operation

LG LS-K2662CL - Healthy Dehumidification Operation - 1

flowchart
graph TD
    A["1 Press the Start/Stop button. The unit will respond with a beep."] --> B["2 Open the door on the remote control. To select Healthy Dehumidification Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow."]
    B --> C["3 Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps-low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted."]
    C --> D["Natural wind by the CHAOS logic"]

Safety Precautions

Operating Instructions

Care and Maintenance

Troubleshooting Tips

During Healthy Dehumidification Operation:

☐ If you select the dehumidification mode on the operation selection button, the A/C starts to run the dehumidification function, automatically setting the room temp. and airflow volume to the best condition for dehumidification based on the sensed current room temp.
In this case, however, the setting temp. is not displayed in the remote control and you are not able to control the room temp. either.
☐ During the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temp. status and makes the room condition healthy and comfortable even in the high humidity season.

LG LS-K2662CL - During Healthy Dehumidification Operation: - 1

Heating Operation(Heat pump model only)

LG LS-K2662CL - Heating Operation(Heat pump model only) - 1

1

Press the Start/Stop button. The unit will respond with a beep.

LG LS-K2662CL - 1 - 1

LG LS-K2662CL - 1 - 2

text_image 30°C *▲0°C

2

Open the door on the remote control. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

LG LS-K2662CL - 2 - 1

LG LS-K2662CL - 2 - 2

text_image 18°C Cooling Auto Healthy Dehumidification 30°C Heating (Heat pump model only)

3

Close the door on the remote control. Set the temperature higher than the room temperature. The temperature can be set within a range of 16^ C- 30^ C in 1^ C increments.

LG LS-K2662CL - 3 - 1

4

Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps—low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted.

LG LS-K2662CL - 4 - 1

Natural wind by the CHAOS logic

☐ For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.

LG LS-K2662CL - Natural wind by the CHAOS logic - 1

Jet Cool Operation

LG LS-K2662CL - Jet Cool Operation - 1

text_image 非 P0

1

Press the Start/Stop button. The unit will respond with a beep.

LG LS-K2662CL - 1 - 1

2

Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes.

LG LS-K2662CL - 2 - 1

3

To cancel the Jet Cool mode, press the Jet Cool button again or the fan speed button or the room temperature setting button and the unit will operate in high fan speed on cooling mode.

LG LS-K2662CL - 3 - 1

text_image Diagram illustrating three hand states: finger press, circular icon with 'or' label, and triangular target with 'or' label.

NOTE:

☐ During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. in the shortest time in a hot summer. In heat pump mode or neuro fuzzy mode however, the JET COOL function is not available.

☐ In order to return to the normal cooling mode from the JET COOL mode, you just press either the operation mode selection button, airflow volume selection or temp. setting button or the JET COOL button again.

LG LS-K2662CL - NOTE: - 1

PLASMA Purification Operation(Option)

LG LS-K2662CL - PLASMA Purification Operation(Option) - 1

flowchart
graph TD
    A["1 Press the Start/Stop button. The unit will respond with a beep."] --> B["2 Open the door on the remote control. Press the PLASMA air purifying operation ON/OFF button. Operation will start when the button is pressed and stop when the button is pressed again."]
    B --> C["3 Set the fan speed again with door of the remote control closed. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button is pressed, the fan speed mode is shifted. * Air purifying operation (PLASMA) with cooling, Heating or any other operations."]

PLASMA Air Purifying Operateion only

LG LS-K2662CL - PLASMA Air Purifying Operateion only - 1

text_image PLASMA

If you press the only PLASMA button, PLASMA air purifying operates only.

Then, fan speed is low. You can select the fan speed in four steps-low, medium, high or CHAOS.

Each time the button ( ) is pressed, the fan speed mode is shifted.

LG LS-K2662CL - PLASMA Air Purifying Operateion only - 2

LG LS-K2662CL - PLASMA Air Purifying Operateion only - 3

Additional features

LG LS-K2662CL - Additional features - 1

Sleep Mode

- Press the Sleep Mode Auto button to set the time you want the unit to turn off automatically.

LG LS-K2662CL - Sleep Mode - 1

The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner.

To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star (☆) disappears from the operation display.

Note: The Sleep Mode will be operated at low fan speed (cooling) or medium fan speed (heat pump only) for quiet sleeping.

Make sure the Sleep Mode Auto LED lights up.

IN COOLING MODE: The temperature will automatically rise by 1°C over the next 30 minutes and by 2°C in 1 hour for comfortable sleeping.

LG LS-K2662CL - Sleep Mode - 2

Setting the Time

Time can be set only when you have pressed the Reset button. If you have just replaced the batteries, the Reset button should be pressed to reset the time.

- Press the Time Setting buttons until the desired time is set.

Press the Start/Stop button.

LG LS-K2662CL - Setting the Time - 1

Press the Timer SET button.

Note: Check the indicator for A.M. and P.M.

LG LS-K2662CL - Setting the Time - 2

LG LS-K2662CL - Setting the Time - 3

Delay Start/Pre-Set Stop

Make sure the time is set correctly on the remote control display.

- Press the selected on/off setting by pressing the Timer SET button while aiming the remote control at the signal receptor.

LG LS-K2662CL - Delay Start/Pre-Set Stop - 1

● Press the ON/OFF Timer buttons to turn Timer on or off.

LG LS-K2662CL - Delay Start/Pre-Set Stop - 2

To cancel the setting the timer.

LG LS-K2662CL - Delay Start/Pre-Set Stop - 3

Press the Timer Cancel button while aiming remote control at the signal receptor.

(The timer lamp on the air conditioner and the display will go out.)

● Press the Time Setting buttons until the desired time is set.

LG LS-K2662CL - Delay Start/Pre-Set Stop - 4

NOTE: Select one of the following four types of operation.

with the unit running

LG LS-K2662CL - Delay Start/Pre-Set Stop - 5
Delay OFF Timer

LG LS-K2662CL - Delay Start/Pre-Set Stop - 6
Delay ON Timer

LG LS-K2662CL - Delay Start/Pre-Set Stop - 7
Delay OFFand ON Timer

LG LS-K2662CL - Delay Start/Pre-Set Stop - 8
Delay ONand OFF Timer

LG LS-K2662CL - Delay Start/Pre-Set Stop - 9

LG LS-K2662CL - Delay Start/Pre-Set Stop - 10

Vertical Airflow Direction Control

The up/down airflow (Vertical Airflow) can be adjusted by using the remote control.

LG LS-K2662CL - Vertical Airflow Direction Control - 1

natural_image Diagram of a rectangular air duct with a curved arrow indicating direction (no text or symbols)

Press the Start/Stop button to start the unit.

Open the door on the remote control. Press Chaos Swing button and the louvers will swing up and down. Press the Chaos Swing button again to set the vertical louver at the desired airflow direction.

LG LS-K2662CL - Vertical Airflow Direction Control - 2

Note:

☐ If you press the CHAOS swing button, the horizontal airflow direction is changed automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable, as if enjoying a natural breeze.
□ Always use the remote control to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand could damage the air conditioner.
☐ When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system.

To adjust left/right(Horizontal Airflow) direction

Caution : Ensure unit is turned off before adjusting the horizontal airflow direction control. Carefully open vertical louver to allow access to the horizontal airflow direction.

Adjust the left/right airflow direction by hand.

LG LS-K2662CL - To adjust left/right(Horizontal Airflow) direction - 1

natural_image Illustration of a rectangular air conditioner unit with airflow arrows indicating direction (no text or symbols)

LG LS-K2662CL - To adjust left/right(Horizontal Airflow) direction - 2

Air Circulation Mode

Circulates the room air without cooling or heating.

LG LS-K2662CL - Air Circulation Mode - 1

Press the Start/Stop button. the unit will respond with a beep.

LG LS-K2662CL - Air Circulation Mode - 2

Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS and back to low again.

LG LS-K2662CL - Air Circulation Mode - 3

LG LS-K2662CL - Air Circulation Mode - 4

flowchart
graph LR
    A["CHAOS Air"] --> B["Fan speed is on low."]
    B --> C["Fan speed is on medium."]
    C --> D["Fan speed is on high."]

Note:

☐ CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.

LG LS-K2662CL - Note: - 1

LG LS-K2662CL - Note: - 2

LG LS-K2662CL - Note: - 3

Slide Switch Operation

FORCED OPERATION

Operation procedures when the remote control can't be used.

Open the front panel upward and move the Slide Switch to the Forced Operation position. If you want to stop operation, move the Slide Switch to the Auto Restart or the Remote Control position. In case the power comes on again after power failure on the Forced Operation position, the operating conditions are automatically set as follows: During Forced Operation, the initial mode continues.

LG LS-K2662CL - FORCED OPERATION - 1
Slide Switch

LG LS-K2662CL - FORCED OPERATION - 2

text_image Slide Switch FORCED OPERATION AUTO RESTART REMOTE CONTROL
Cooling ModelHeat pump Model
Room Temp. ≥24°C21°C ≤ Room Temp. < 24°CRoom Temp. < 21°C
Operating modeCoolingCoolingHealthy DehumidificationHeating
Indoor FAN SpeedHighHighHealthy Dehumidification RuleHigh
Setting Temperature22°C22°C23°C24°C

Auto restart

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.

In case the air conditioner does not receive any signal from the remote control, it will turn off automatically after 7 hours. If you want to use this operation, Open the front panel upward and move the slide switch to the Auto Restart position. If you do not want to use this operation, move the Slide Switch to the Remote Control position.

LG LS-K2662CL - Auto restart - 1
.Slide Switch

LG LS-K2662CL - Auto restart - 2

text_image Slide Switch FORCED OPERATION AUTO RESTART REMOTE CONTROL

When you are out for a while, put the Slide Switch on the Remote Control.

Helpful information

Fan speed and cooling capacity. The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room quickly.

LG LS-K2662CL - Helpful information - 1

text_image High Speed

Care and maintenance of the air conditioner

CAUTION: Before performing any maintenance, turn off the main power to the system.

Indoor Unit

Grille, Case, and Remote Control

☐ Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.

NOTE:

Supply power must be disconnected before deaning the indoor unit.

LG LS-K2662CL - NOTE: - 1

text_image Air inlet vent Air outlet vent Vertical louver Horizontal louver Air filters (behind front panel)

AIR FILTERS

The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if necessary.

LG LS-K2662CL - AIR FILTERS - 1

natural_image Diagram of a heat exchanger or cooling unit with cooling fins and internal cooling elements (no text or labels)

PLASMA FILTER, DEODORIZER FILTER(OPTION)

The PLASMA filter behind the air filters should be checked and cleaned once every 3 months or more often if necessary.

LG LS-K2662CL - PLASMA FILTER, DEODORIZER FILTER(OPTION) - 1

text_image DEODORIZER Filter PLASMA Filter

LG LS-K2662CL - PLASMA FILTER, DEODORIZER FILTER(OPTION) - 2

Don't touch this PLASMA Filter within 10 seconds after opening the inlet grille, it may cause an electric shock.

□ Never use any of the followings:

• Water hotter than 40^ C Could cause deformation and/or discoloration.
- Volatile substances Could damage the surfaces of the air conditioner.

LG LS-K2662CL - PLASMA FILTER, DEODORIZER FILTER(OPTION) - 3

  • Lift the front access panel and pull the filter tab slightly forward to remove the filter.
    ● Clean the filter with a vacuum or warm, soapy water.

  • If dirt is conspicuous, wash with a solution of detergent in lukewarm water.

  • If hot water (40°C or more) is used, it may be deformed.

● After washing with water, dry well in the shade.

Re-install the air filter.

● After removing the air filters, pull slightly forward to remove the PLASMA filter.

● Dip the PLASMA filter into the water mixed with neutral detergent, for 20\~30 minutes.

● Dry the PLASMA filter in the shade for a day (Especially, the humidity must be removed perfectly on this parts).

Note the cuts of electric discharge lines.

● Re-install the PLASMA filter to the original position.

● After removing the air filters, pull slightly forward to remove the DEODORIZER filter.

Dry in the sunlight for tow hours.

● Re-install the DEODORIZER filter to the original position.

Replacement of Purifying Filter(Option)

• Recommended use period : About 2 years

LG LS-K2662CL - Replacement of Purifying Filter(Option) - 1

Open front panel and remove air filters.

LG LS-K2662CL - Replacement of Purifying Filter(Option) - 2

text_image Air filter

LG LS-K2662CL - Replacement of Purifying Filter(Option) - 3

Remove air purifying filters.

LG LS-K2662CL - Replacement of Purifying Filter(Option) - 4

Insert new air purifying filters.

LG LS-K2662CL - Replacement of Purifying Filter(Option) - 5

text_image Technical diagram of an air conditioner unit with labeled parts ② and ③

LG LS-K2662CL - Replacement of Purifying Filter(Option) - 6

Reinsert air filters and close front panel.

LG LS-K2662CL - Replacement of Purifying Filter(Option) - 7

natural_image Technical illustration of a heat exchanger or cooling unit with internal components and mounting brackets (no text or symbols)

LG LS-K2662CL - Replacement of Purifying Filter(Option) - 8

text_image Air purifying filter

Outdoor Unit

The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. Air in vent

NOTE:

Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.

LG LS-K2662CL - NOTE: - 1

text_image gged Air intake vents (Side) (Air outlet vents) (Rear) Piping Drain Hose

LG LS-K2662CL - NOTE: - 2

text_image Air intake vents (Side) Air outlet vents (Rear) Piping Drain Hose

LG LS-K2662CL - NOTE: - 3

text_image Air intake vents (Side) (Air outlet vents) (Rear) Piping Drain Hose

LG LS-K2662CL - NOTE: - 4

When the air conditioner is not going to be used for a long time.

on air conditioner is not going to be a long time.

Operate the air conditioner on Air circulation mode (Refer to page 14) for 2 to 3 hours.

• This will dry out the internal mechanisms.

2 Turn off the circuit breaker, and disconnect the plug.

[NO TEXT]

Turn off the circuit breaker when the air conditioner is not going to be used for a long time.

Dirt may collect and may cause a fire.

3 Remove the batteries from the remote control.

then the air conditioner is to be used again

/ Clean the air filter and install it in the indoor unit. (Refer to page 16 for cleaning filters.)

2 Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.

Operation Tips

This is not good for the health and wastes electricity.

Avoid opening doors and windows as much as possible to keep the cool air in the room.

Do not let direct sunshine enter the room when the air conditioner is in operation.

Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects. Clean at least once every two weeks.

Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room.

Since windows are kept closed, it is a good idea to open them and ventilate the room now and then.

Before you call for service...

LG LS-K2662CL - Before you call for service... - 1

Troubleshooting Tips! Save time and money!

Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or service center.

CaseExplanationSee page
The air conditioner does not operate.Have you made a mistake in timer operation?13
Has the fuse blown or has the circuit breaker been tripped?-
The room has a peculiar odor.Check that this is not a damp smell exuded by the walls, carpet, furniture, or cloth items in the room.-
It seems that condensation is leaking from the air conditioner.Condensation occurs when the airflow from the air conditioner cools the warm room air.-
Air conditioner does not operate for about 3 minutes when restarted.This is the protector of the mechanism.Wait about three minutes and operation will begin.-
Does not cool or heat effectively.Is the air filter dirty? See air filter cleaning instructions.16
Has the temperature been set incorrectly?7, 10
Are the indoor unit's air inlet or outlet vents obstructed?-
The air conditioner operation is noisy.For a noise that sounds like water flowing.-This is the sound of freon flowing inside the air conditioner unit.For a noise that sounds like the compressed air releasing into atmosphere.-This is the sound of the dehumidifying water being processed inside the air conditioning unit.-
Remote control display is faint, or no display at all.Are the batteries depleted?Are the batteries inserted in the opposite (+) and (-) directions?4
Crack sound is heard.This sound is generated by the expansion/constriction of the front panel, etc. due to changes of temperature.-

NOTE

WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT. The indoor side is not water resistant and should not be exposed to excess water.

LG LS-K2662CL - NOTE - 1

LG Electronics Inc.

P/No.: 3828A30048B

Printed in Korea

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : LG

Model : LS-K2662CL

Category : Air-conditioner