Beverage-Air

UCF32AHC - Freezer Beverage-Air - Free user manual and instructions

Find the device manual for free UCF32AHC Beverage-Air in PDF.

📄 34 pages English EN Download 💬 AI Question
Notice Beverage-Air UCF32AHC - page 2
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about UCF32AHC Beverage-Air

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Freezer in PDF format for free! Find your manual UCF32AHC - Beverage-Air and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UCF32AHC by Beverage-Air.

USER MANUAL UCF32AHC Beverage-Air

text_image BEVERAGE-AIR

BEVERAGE-AIR

INSTALLATION AND OPERATING INSTRUCTIONS for all Hydrocarbon Dual Temp Undercounter UCRF Refrigerator/Freezer Models

Beverage-Air UCF32AHC - INSTALLATION AND OPERATING INSTRUCTIONS for all Hydrocarbon Dual Temp Undercounter UCRF Refrigerator/Freezer Models - 1

natural_image Exterior view of a modern stainless steel refrigerant cabinet with 'BEVERAGE-AIR' branding on the side (no other text or symbols visible)

User Manual for UCRF Refrigerator Freezer Beverage Air

WELCOME

Congratulations on your purchase of Beverage-Air food service equipment. Every employee welcomes you to the family of satisfied Beverage-Air customers.

From the earliest stages of production design, to focused steps in fabrication and assembly, rigid standards of quality are maintained by our staff of skilled employees. Beverage-Air strives to supply superior products through strict quality control guidelines exceeding industry standards, this means that each unit, given the proper maintenance will provide years of trouble free experience to its owner.

Additionally, Beverage-Air food service equipment has one of the best warranties in the food service industry, and backed by a professional staff of service technicians across the country.

We thank you for your choice and confidence in Beverage-Air Equipment.

For part inquiries or orders please call our Technical Service Department at (800) 684-1199. 8:00 AM to 5:00 PM EST.

Important Information

- PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR USING, IF RECOMMENDED PROCEDURES ARE NOT FOLLOWED, WARRANTY CLAIMS MAY BE DENIED.

- Your warranty registration information is located with this manual. Please complete the card and submit it to Beverage Air within TEN days of installation. Failure to properly register equipment may limit or void the warranty.

- Beverage Air reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.

User Manual for UCRF Refrigerator Freezer Beverage Air

SAFETY

This appliance has been designed with your safety in mind. It has many features to keep you from being harmed. However, safe operation and maintenance are your responsibilities. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

CAUTION

Use: When using this unit, please:

  • Move it carefully. If on casters be sure the casters do NOT run over the power cord.
  • Lock the casters when in use.
  • Seek help. This machine is heavy! Be sure to move with enough help to avoid tipping or dropping the cabinet.

CAUTION

Maintenance

Do NOT:

  • Clean a frozen evaporator with a sharp object
  • Clean a dirty condenser with a sharp object.
  • Store gasoline, kerosene or any other flammable material near the cabinet

  • Prevent children from playing in or on the cabinet. Persons unable to use this product must be prevented access.

  • Follow all instructions. There are many safety labels and directions on the unit. Heed them.
  • Watch your fingers. There may be pinch points near the door hinges.

Do ALWAYS

  • Use a Beverage Air recommended technician certified to repair R290 equipment.
  • Use ONLY Beverage Air factory service parts. Use of non OEM parts can be dangerous because of the design

User Manual for UCRF Refrigerator Freezer Beverage Air

SAFETY

For your protection, safety labels have been placed at important locations on the cabinet. Be SURE to read and follow their instructions.

Beverage-Air UCF32AHC - SAFETY - 1

text_image A. CAUTION Use of Fire for Exclusion, Tremadise Change in the number of cases that are dramed to the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are from the number of cases that are From the number of cases that are From the number of cases that are From the number of cases that are From the number of cases that are From the number of cases that are From the number of cases that are From the number of cases that are From the number of cases that are From the number of cases that are From the number of cases that are From the number of cases that are From the number of cases that are From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers From the number of case numbers To be repeated by a person who has been first- repeated. To be repeated by another person who has been first- repeated. To be repeated by third person who has been first- repeated. To be repeated by fourth person who has been first- repeated. To be repeated by fifth person who has been first- repeated. To be repeated by sixth person who has been first- repeated. To be repeated by seventh person who has been first- repeated. To be repeated by eight person who has been first- repeated. To be repeated by nine person who has been first- repeated. To be repeated by 10 person who has been first- repeated. To be repeated by 11 person who has been first- repeated. To be repeated by 12 person who has been first- repeated. To be repeated by 13 person who has been first- repeated. To be repeated by 14 person who has been first- repeated. To be repeated by 15 person who has been first- repeated. To be repeated by 16 person who has been first- repeated. To be repeated by 17 person who has been first- repeated. To be repeated by 18 person who has been first- repeated. To be repeated by 19 person who has been first- repeated. To be repeated by 20 person who has been first- repeated. To be repeated by 21 person who has been first- repeated. To be repeated by 22 person who has been first- repeated. To be repeated by 23 person who has been first- repeated. To be repeated by 24 person who has been first- repeated. To be repeated by 25 person who has been first- repeated. To be repeated by 26 person who has been first- repeated. To be repeated by 27 person who has been first- repeated. To be repeated by 28 person who has been first- repeated. To be repeated by 29 person who has been first- repeated. To be repeated by 30 person who has been first- repeated. To be repeated by 31 person who has been first- repeated. To be repeated by 32 person who has been first- repeated. To be repeated by 33 person who has been first- repeated. To be repeated by 34 person who has been first- repeated. To be repeated by 35 person who has been first- repeated. To be repeated by 36 person who has been first- repeated. To be repeated by 37 person who has been first- repeated. To be repeated by 38 person who has been first- repeated. To be repeated by 39 person who has been first- repeated. To be repeated by 40 person who has been first- repeated. To be repeated by 41 person who has been first- repeated. To be repeated by 42 person who has been first- repeated. To be repeated by 43 person who has been first- repeated. To be repeated by 44 person who has been first- repeated. To be repeated by 45 person who has been first- repeated. To be repeated by 46 person who has been first- repeated. To be repeated by 47 person who has been first- repeated. To be repeated by 48 person who has been first- repeated. To be repeated by 49 person who has been first- repeated. To be repeated by 50 person who has been first- repeated. To be repeated by 51 person who has been first- repeated. To be repeated by 52 person who has been first- repeated. To be repeated by 53 person who has been first- repeated. To be repeated by 54 person who has been first- repeated. To be repeated by 55 person who has been first- repeated. To be repeated by 56 person who has been first- repeated. To be repeated by 57 person who has been first- repeated. To be repeated by 58 person who has been first- repeated. To be repeated by 59 person who has been first- repeated. To be repeated by 60 person who has been first- repeated. To be repeated by 61 person who has been first- repeated. To be repeated by 62 person who has been first- repeated. To be repeated by 63 person who has been first- repeated. To be repeated by 64 person who has been first- repeated. To be repeated by 65 person who has been first- repeated. To be repeated by 66 person who has been first- repeated. To be repeated by 67 person who has been first- repeated. To be repeated by 68 person who has been first- repeated. To be repeated by 69 person who has been first- repeated. To be repeated by 70 person who has been first- repeated. To be repeated by 71 person who has been first- repeated. To be repeated by 72 person who has been first- repeated. To be repeated by 73 person who has been first- repeated. To be repeated by 74 person who has been first- repeated. To be repeated by 75 person who has been first- repeated. To be repeated by 76 person who has been first- repeated. To be repeated by 77 person who has been first- repeated. To be repeated by 78 person who has been first- repeated. To be repeated by 79 person who has been first- repeated. To be repeated by 80 person who has been first- repeated. To be repeated by 81 person who has been first- repeated. To be repeated by 82 person who has been first- repeated. To be repeated by 83 person who has been first- repeated. To be repeated by 84 person who has been first- repeated. To be repeated by 85 person who has been first- repeated. To be repeated by 86 person who has been first- repeated. To be repeated by 87 person who has been first- repeated. To be repeated by 88 person who has been first- repeated. To be repeated by 89 person who has been first- repeated. To be repeated by 90 person who has been first- repeated. To be repeated by 91 person who has been first- repeated. To be repeated by 92 person who has been first- repeated. To be repeated by 93 person who has been first- repeated. To be repeated by 94 person who has been first- repeated. To be repeated by 95 person who has been first- repeated. To be repeated by 96 person who has been first- repeated. To be repeated by 97 person who has been first- repeated. To be repeated by 98 person who has been first- repeated. To be repeated by 99 person who has been first- repeated.

Note: The top panel of this unit can be damaged by standing on it. Damage like that is NOT covered by warranty.

Beverage-Air UCF32AHC - SAFETY - 2

! WARNING

Risk of Personal Injury From Falling

Stay OFF top of unit

User Manual for UCRF Refrigerator Freezer Beverage Air

IMPORTANT INFORMATION

This unit is intended to be used in a commercial application. That includes bars and restaurants.

If installed in a residence some commercial service companies may not be able to service it on site.

The manufacturer has designed and produced this machine with the finest in materials. The manufacturer assumes no liability for units that have been altered in any way. Alterations or part substitutions will void the warranty.

Limitations

The machine is designed for use indoors in a controlled environment. It must be kept dry, not overheated or subjected to excessive cold. May only be connected to a dedicated electrical circuit. Extension cords are not permitted.

Minimum Maximum
Voltage 103.5 126.5
Room Air Temp 60°F 100° F

Air Flow, All Models regardless of section, door count or door material.

Beverage-Air UCF32AHC - Limitations - 1

text_image Warm Air OUT

User Manual for UCRF Refrigerator Freezer Beverage Air

PRODUCT INFORMATION

ModelCabinet Dimensions w x d x h (Inches)Door CountFull Load Amps - RefrigeratorFull Load Amps - FreezerPower Cord Plug (NEMA)Refrigerant Type / Charge (g) / Charge (oz)
UCRF48AHC 48 × 32 × 34 12 22 2.5(2) 5-15P R-290 / 60 / 2.03
UCFR48AHC 48 × 32 × 34 12 22 2.5

Height includes casters.

User Manual for UCRF Refrigerator Freezer Beverage Air

CLEARANCE AND PLACEMENT

Beverage-Air UCF32AHC - CLEARANCE AND PLACEMENT - 1

Placement

User Manual for UCRF Refrigerator Freezer Beverage Air

UNPACKING AND SET UP

Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim. Do NOT contact the manufacturer.

Uncrating

Tools Needed: 12 " box wrench, adjustable wrench, level, flat head screw driver, and box cutter.

  1. Cut the stretch wrap along a corner post and remove the cardboard top capping and the corner posts.
  2. Discard stretch wrap and any cardboard that will not be recycled.

Note: additional clear plastic protective wrap is applied directly to any product with a glass door.

Skid Removal and Caster Attachment

Tip the unit forward and remove the skid.

Beverage-Air UCF32AHC - Skid Removal and Caster Attachment - 1

Beverage-Air UCF32AHC - Skid Removal and Caster Attachment - 2

Risk of personal injury. Unit must be securely supported while attaching casters or legs.

  1. Remove the shipping bolts using the 34 " box wrench while cabinet is held in one direction. Repeat the process while the cabinet is held in the opposite direction.

  2. Move unit as close to final position as possible before removing the skid.

Note: The skid must be removed before the casters or legs can be attached.

Do NOT tip unit on its front or sides. If tipped onto the back, unit must not be started for 3 hours.

suitable material.

  1. Thread the stem casters or legs into the 12 -13 holes in the bottom of the cabinet. Tighten by hand as much as possible.
  2. Once the caster or leg cannot be turned any further, use a 3/4 inch wrench to tighten the nut in between the mounting plate and the wheel of the caster until snug.
  3. Repeat this procedure with unit secured in the opposite direction so as to access the remaining legs/

User Manual for UCRF Refrigerator Freezer Beverage Air

SHELF INSTALLATION

  1. Determine the proper location for the shelf clips.
  2. Insert the top tab of the shelf clip into the desired hole of the pilaster. The retaining tab MUST be facing up as shown.
  3. Rotate the clip downwards and insert the bottom tab into the matching hole in the pilaster. The clip may need to be squeezed slightly during installation.
  4. Install all remaining clips.
  5. Install shelves onto clips with the product retention bar facing up. Be careful not to dislodge clips during installation.
  6. Place shelves so that the retaining tab on the clip captures the shelf as shown.

  7. Confirm that the shelf is resting on ALL 4 clips and that the clips are securely attached to the pilasters.

  8. Improper shelf clip installation could cause the shelf and / or the product on it to fall, resulting in damage to the unit and possible bodily injury.
  9. Do NOT overload the shelves. The unit is designed to use all shelves that are supplied in an equally spaced manner. Contact Beverage Air customer service if fewer shelves or a different configuration to ensure shelf overloading will not occur.

Beverage-Air UCF32AHC - SHELF INSTALLATION - 1

text_image RETAINING TAB TOP TAB S HELF CUP BOTTOM TAB

Beverage-Air UCF32AHC - SHELF INSTALLATION - 2
PROPERLY INSTALLED CLIP

Beverage-Air UCF32AHC - SHELF INSTALLATION - 3
IMPROPERLY INSTALLED CLIP (UPSIDE DOWN)

User Manual for UCRF Refrigerator Freezer Beverage Air

ELECTRICAL

This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.

Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to unsafe cabinet temperature when GFI device trips from moisture.

Power Cord

This 115 volt model is equipped with 2 cords and 5-15P plugs.

If the power cord becomes damaged, it must be replaced with the identical cord.

Follow All National and Local Codes

This unit must be grounded. Do not use extension cords and do not disable or by-pass ground prong on electrical plug.

Initial Start Up

Plug the power cord into the proper power supply.

The cabinet will soon begin to blow warm air out of the top area, and cool air will flow from the inside blower.

The cabinet temperatures have been set at the factory and should not need adjustment, however if changed, the standard refrigerator setting is 38^ F., while the standard freezer setting is 0^

Care must be taken whenever moving or servicing the

User Manual for UCRF Refrigerator Freezer Beverage Air

USING THE UNIT - DANFOSS CONTROLLER

Operation is simple, just keep it connected to the correct power supply and the refrigerator will maintain the internal temperature it has been set to. Keep the doors closed as much as possible to avoid unnecessary run time.

There are two controllers, both in the lower front grille of the cabinet. The left one is for the freezer section and the right one is for the refrigerator. Each controller displays the current internal temperature for its section.

Adjusting the set temperature lower will NOT cause the system to lower the temperature faster. When on, the refrigeration system is always operating at maximum.

For best results, make certain the unit remains powered and has achieved the desired set point before loading it with product. Pull down time will vary depending upon the type of unit and ambient conditions

The refrigerator temperature was set at the factory at 38^ F, and the freezer temperature was set at 0^ F., but you can adjust it to your own selected temperature.

Each section will automatically defrost as needed, there is no set time for defrost. Push and immediately release the "melting" or defrost button for a manual defrost.

Note: Holding the defrost button in too long will shut the controller off.

The internal fan will be on whenever the appliance is connected to power.

The compressor and condenser fan motor will only be on when the controller senses an increase in internal cabinet temperature passed the set point.

Beverage-Air UCF32AHC - USING THE UNIT - DANFOSS CONTROLLER - 1

text_image Denfotá Defrost 38.0°F Λ SC V Select Increase Decrease

In most cases the only thing displayed will be the cabinet temperature. When something other than normal operation has occurred, a message will be shown.

Message Displayed Why What to do
dEFUnit is defrosting Nothing. Normal operation.
H1Cabinet temperature too warm Confirm doors or drawers are closed.
dORDoor is open Close door, if message does not change, call for service.
LERCompressor run time too long Check doors closed. If yes, call for service.
EO1, E02, E03, E04Sensor unplugged or has failed Call for service.

User Manual for UCRF Refrigerator Freezer Beverage Air

SEQUENCE OF OPERATIONS - REFRIGERATOR SECTION - DANFOSS CONTROLLER

The refrigerator operates based on the air temperature measured by the probe located at the return air.

ON OFF
COMPONENT OPERATION CONTROLLED ACTION CONTROLLED ACTION
COMPRESSORCompressor turns on when the air temperature at the probe is above the sum of the set point +2The Compressor Contact is energizedCompressor turns off when the air temperature at probe is equal to or less than the set point -2The Compressor Contact is de-energized
(ERC 112 - Terminal #1)(ERC 112 - Terminal #1)
CONDENSER FANThe Condenser Fan turns on when the Compressor is runningThe Condenser Fan is wired directly to the Compressor, not through the controllerThe Condenser Fan turns off when the Compressor is not runningThe Condenser Fan is wired directly to the Compressor, not through the controller
EVAPORATOR FANThe Evaporator Fan runs continuously in refrigerators. When the unit is plugged in, the Evaporator Fan will run.The Evaporator Fan is connected directly to incoming power, not through the controller.The Evaporator Fan runs continuously. When the unit is plugged in, The Evaporator Fan will run.The Evaporator Fan is connected directly to incoming power, not through the controller.
ConditionCompressorCondenser FanEvaporator Fan
Cabinet Temp > Set point + 2 ON ON ON
Cabinet Temperature <= Set point - 2 OFF OFF ON
DefrostOFF ONFF ON

User Manual for UCRF Refrigerator Freezer Beverage Air

REFRIGERATOR SECTION

Electronic Controller
Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 1

text_image DEFROST (ESC) UP 48°C SC V DOWN

Control Panel Display

Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 2Defrost LED Alarm LEDBeverage-Air UCF32AHC - REFRIGERATOR SECTION - 3
On fixed: Defrost active On fixed: ALARM Pre
Off: Defrosts off Flashing: ALARM Silenced
Off: No Alarm
Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 4Fan LED Compressor LEDBeverage-Air UCF32AHC - REFRIGERATOR SECTION - 5
On fixed:Fan activeOn fixed: Compressor active
Off:Fan OffFlashing: Delay, protection or activation blocked
Off: No Alarm

NOTE: When switched on, the instrument panel performs a lamp test for a few seconds. Keyboard Functions

Note: When the controller is in a Standby Mode, a blue dot will be displayed as shown here. To switch out of Standby Mode, push and hold the Defrost button until the display reads ON.

Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 6

text_image Danford SC V Λ

User Manual for UCRF Refrigerator Freezer Beverage Air

REFRIGERATOR SECTION

Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 1

text_image ERC 112C 100 - 240V AC ± 10% 50/60 Hz DT55 Outputs 1 2 3 4 5 DO1 L N DO2 DO3 Inputs S1 S2 S3 S4 di
  1. Current temperature
    Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 2

The display shows the current temperature

  1. Flashing temperature setpoint
    Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 3

Press: UP/DOWN to adjust setup

  1. Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 4

After 30 seconds, the display automatically reverts to showing the current temperature

User Manual for UCRF Refrigerator Freezer Beverage Air

REFRIGERATOR SECTION

The alarm condition is always signaled by the alarm icon 🔔.

Press any button to silence the alarm, the relative icon will continue flashing.

Alarm CodeTriggerAutomatic ClearanceOutputsComments
"Hi"Air temperature is higher than "ALA->Hat• for "ALA->Htd"User configuredBlink "Hi" with the highest temperature; If configured: cut in alarm relay, beep the buzzerHigh temperature alarm
"Lo"Air temperature is lower than "LAt" for "Ltd"User configuredBlink "Lo" with the lowest temperature. If configured: cut in alarm relay, beep the buzzerLow temperature alarm
"Con"Condenser temperature is too high or too lowUser configuredBlink "Con". If configured: cut in alarm relay, beep the buzzerCondenser alarm
"dor"Door open for more thanAlwaysBlink "dor". If configured: cut in alarm relay, beep the buzzerDoor open alarm
"uHi"Line voltage is higher than "Cop->uHi"AlwaysBlink "uHi". If configured: cut in alarm relay, beep the buzzerHigh voltage alarm
"uLi"Line voltage is higher than "Cop->uLi"AlwaysBlink "uLo". If configured: cut in alarm relay, beep the buzzer.Low voltage alarm
"LEA"Compressor continuous running for more than "ALA->LEA"AlwaysBlink "LEA". If configured: cut in alarm relay, beep the buzzerLeakage alarm
"E01""S1" errorAlwaysBlink "E01 ". If configured: cut in alarm relay, beep the buzzer"S1" sensor failure (short or open)
"E02""S1" errorAlwaysBlink "E02". If configured: cut in alarm relay, beep the buzzer"S2" sensor failure (short or open)
"E03""S1" errorAlwaysBlink "E03 ". If configured: cut in alarm relay, beep the buzzer"S3" sensor failure (short or open)
"E04""S1" errorAlwaysBlink "E04 ". If configured: cut in alarm relay, beep the buzzer"S4" sensor failure (short or open)

How to Acknowledge Alarms:

NOTE: If alarm exclusion times are in progress (ALA folder of the parameter table), the alarm is not signaled.

1.

Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 1

The alarm code flashing alternately with the temperature and the alarm symbol is displayed

Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 2

2.

Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 3

After the acknowledge the temperature is displayed and the alarm symbol remains shown

Press any button to acknowledge

User Manual for UCRF Refrigerator Freezer Beverage Air

The cooler operates based on the air temperature measured by the probe located at the return air.

ON Off
COMPONENT OPERATION CONTROLLER ACTIONOPERATION CONTROLLER ACTION
COMPRESSOR Compressoror turns on when the air temperature at the probe is above the sum of the set point + 2.5The Compressor Contact is energized(ERC 112 - Terminal #1)Compressor turns off when the air temperature at probe is equal to or less than the set point - 2.5The Compressor Contact is de-energized
CONDENSER FAN The Condenser Fan turns on when the Compressor is runningThe Condenser Fan is wired directly to the Compressor, not through the controllerThe Condenser Fan turns off when the Compressor is not runningThe Condenser Fan is wired directly to the Compressor, not through the controller
EVAPORATOR FAN The Evaporator Fan runs continuously.When the unit is plugged in the Evaporator Fan will runThe Evaporator Fan Contact is energized.(ERC 112 - Terminal #5)The Evaporator Fan turns off when freezer enters a defrost cycle.The Evaporator fan Contact is deener-gized.(ERC 112 - Terminal #5)
DEFROST HEATER The Defrost Heater will activate on cumulative Compressor runtime of 6 hours, and when temperature drops too lowThe Defrost Heater Contact is energized(ERC 112 - Terminal #6)When either the defrost is not scheduled or the temperature at defrost probe has reached the defrost termination temperature.The Defrost Heater Contact is de-ener-gized(ERC 112 - Terminal #6)
FACE/DOOR HEATERS The Face & Door Heat-ers turn on when the Compressor is runningThe Door/Face Heater are wired to the Com-pressor Contact(ERC 112 - Terminal #1)The Face & Door Heaters turn off when the Compressor is not running(ERC 112 - Terminal #1)The Door/Face Heater are wired to the Com-pressor Contact
LIGHT 'The light will turn on when thescis pressed (or when the door is opened with solid doors)The Light Contact is energized(ERC 112 - Terminal #4)The light will turn off when thescis pressed (or when the door is closed with solid doors)The Light Contact is de-energized(ERC 112 - Terminal #4)
ConditionCompressorCondenser FanEvaporator FanDefrost HeaterFace/Door HeaterDrain HeaterLights
Cabinet Temp > Set point + 2.5ONONONOFFONONON or OFF
Cabinet Temperature <= Set point - 2.5OFFOFFONOFFOFFONON or OFF
DefrostOFFOFFOFFONOFFONON or OFF

User Manual for UCRF Refrigerator Freezer Beverage Air

FREEZER SECTION

Electronic Controller

Beverage-Air UCF32AHC - FREEZER SECTION - 1

text_image DEFROST (ESC) UP 48°C SC V DOWN

Control Panel Display

Note: Defrost is manual, LED indicator is inoperative.

Beverage-Air UCF32AHC - Control Panel Display - 1Defrost LED Alarm LEDBeverage-Air UCF32AHC - Control Panel Display - 2
On fixed: Defrost active On fixed: ALARM Pre
Off: Defrosts off Flashing: ALARM Silenced
Off: No Alarm
Beverage-Air UCF32AHC - Control Panel Display - 3Fan LED Compressor LEDBeverage-Air UCF32AHC - Control Panel Display - 4
On fixed:Fan activeOn fixed: Compressor active
Off:Fan OffFlashing: Delay, protection or activation blocked
Off: No Alarm

NOTE: When switched on, the instrument panel performs a lamp test for a few seconds.

Keyboard Functions

Beverage-Air UCF32AHC - Control Panel Display - 5Beverage-Air UCF32AHC - Control Panel Display - 6Beverage-Air UCF32AHC - Control Panel Display - 7Beverage-Air UCF32AHC - Control Panel Display - 8
UPDOWNDEFROST (ESC)SET (ENTER)
Quick press and release• Increases Set PointQuick press and release• Decreases Set PointQuick press and release• Activates manual defrostQuick press and release• Toggles lights on/off
Long press and release• Increases display brightnessLong press and release• Decreases display brightnessLong press and release• Controller enter stand-by modeLong press and release• Toggles display °F/°C

Note: When the controller is in a Standby Mode, a blue dot will be displayed as shown here. To switch out of Standby Mode, push and hold the Defrost button until the display reads ON.

Beverage-Air UCF32AHC - Control Panel Display - 9

text_image Dunfoss SC Λ V

User Manual for UCRF Refrigerator Freezer Beverage Air

FREEZER SECTION

Control Panel Connections

Beverage-Air UCF32AHC - FREEZER SECTION - 1

text_image ERC 112D 100 - 240 V AC ± 10% 50/60 Hz 0T55 Outputs 1 2 3 4 5 6 DO1 L N DO2 DO3 DO4 Inputs S1 S2 S3 S4 di

Changing the Set Point

Current temperature
Beverage-Air UCF32AHC - FREEZER SECTION - 2

text_image 1. 49°C The display shows the current temperature

Flashing temperature setpoint
Beverage-Air UCF32AHC - FREEZER SECTION - 3

text_image 2. DCD 48 °C Press: UP/DOWN to adjust setup

Beverage-Air UCF32AHC - FREEZER SECTION - 4

text_image 3. 48°C After 30 seconds, the display automatically reverts to showing the current temperature

User Manual for UCRF Refrigerator Freezer Beverage Air

FREEZER SECTION

The alarm condition is always signaled by the alarm icon 🔔.

Press any button to silence the alarm, the relative icon will continue flashing.

Alarm CodeTriggerAutomatic ClearanceOutputsComments
"Hi"Air temperature is higher than "ALA->Hat• for "ALA->Htd"User configuredBlink "Hi" with the highest temperature; If configured: cut in alarm relay, beep the buzzerHigh temperature alarm
"Lo"Air temperature is lower than "LAt" for "Ltd"User configuredBlink "Lo" with the lowest temperature. If configured: cut in alarm relay, beep the buzzerLow temperature alarm
"Con"Condenser temperature is too high or too lowUser configuredBlink "Con". If configured: cut in alarm relay, beep the buzzerCondenser alarm
"dor"Door open for more thanAlwaysBlink "dor". If configured: cut in alarm relay, beep the buzzerDoor open alarm
"uHi"Line voltage is higher than "Cop->uHi"AlwaysBlink "uHi". If configured: cut in alarm relay, beep the buzzerHigh voltage alarm
"uLi"Line voltage is higher than "Cop->uLi"AlwaysBlink "uLo". If configured: cut in alarm relay, beep the buzzer.Low voltage alarm
"LEA"Compressor continuous running for more than "ALA->LEA"AlwaysBlink "LEA". If configured: cut in alarm relay, beep the buzzerLeakage alarm
"E01""S1" errorAlwaysBlink "E01 ". If configured: cut in alarm relay, beep the buzzer"S1" sensor failure (short or open)
"E02""S1" errorAlwaysBlink "E02". If configured: cut in alarm relay, beep the buzzer"S2" sensor failure (short or open)
"E03""S1" errorAlwaysBlink "E03 ". If configured: cut in alarm relay, beep the buzzer"S3" sensor failure (short or open)
"E04""S1" errorAlwaysBlink "E04 ". If configured: cut in alarm relay, beep the buzzer"S4" sensor failure (short or open)

How to Acknowledge Alarms:

NOTE: If alarm exclusion times are in progress (ALA folder of the parameter table), the alarm is not signaled.

Beverage-Air UCF32AHC - FREEZER SECTION - 1

The alarm code flashing alternately with the temperature and the alarm symbol is displayed

Beverage-Air UCF32AHC - FREEZER SECTION - 2

Beverage-Air UCF32AHC - FREEZER SECTION - 3

After the acknowledge the temperature is displayed and the alarm symbol remains shown

Press any button to acknowledge

User Manual for UCRF Refrigerator Freezer Beverage Air

USING THE UNIT - REFRIGERATOR SECTION - EUNWELL CONTROLLER

Operation is simple, just keep it connected to the correct power supply and the refrigerator will maintain the internal temperature it has been set to. Keep the doors and / or drawers closed as much as possible to avoid unnecessary run time.

The controller displays the current internal temperature.

Adjusting the set temperature lower will NOT cause the system to lower the temperature faster. When on, the refrigeration system is always operating at maximum.

The temperature was set at the factory at 35^ F, but you can adjust it to your own selected temperature. 30 seconds after adjustment, the display automatically reverts to showing the current temperature.

The refrigerator will automatically defrost as needed, there is no set time for defrost. Push and immediately release the "melting" or defrost button for a manual defrost.

The internal fan will be on when the unit is plugged in.

The compressor and condenser fan motor will only be on when the controller senses an increase in internal cabinet temperature passed the set point.

If equipped with glass doors, pressing the down button in will turn the cabinet light on or off.

Beverage-Air UCF32AHC - USING THE UNIT - REFRIGERATOR SECTION - EUNWELL CONTROLLER - 1

text_image Up Down -8.89 °F AUX °C Esc SET Select

In most cases the only thing displayed will be the cabinet temperature. When something other than normal operation has occurred, a message will be shown.

Message DisplayedWhyWhat to do
dEFUnit is defrostingNothing. Normal operation.
AH1Cabinet temperature too warmConfirm doors or drawers are closed.
OPdDoor is openClose door, if message does not change, call for service.
E1, E2, E3, E4Sensor unplugged or has failedCall for service.

User Manual for UCRF Refrigerator Freezer Beverage Air

SEQUENCE OF OPERATIONS - REFRIGERATOR SECTION

The refrigerator operates based on the air temperature measured by the probe located at the return air.

ONOFF
COMPONENTOPERATIONCONTROLLER ACTIONOPERATIONCONTROLLER ACTION
COMPRESSORCompressor turns on when the air temperature at the probe is above the sum of the set point + 4The Compressor Contact is energizedCompressor turns off when the air temperature at probe is equal to or less than the set pointThe Compressor Contact is de-energized
(EW+978 - Terminal #1)(EW+978 - Terminal #1)
CONDENSER FANThe Condenser Fan turns on when the Compressor is runningThe Condenser Fan is wired directly to the Compressor, not through the controllerThe Condenser Fan turns off when the Compressor is not runningThe Condenser Fan is wired directly to the Compressor, not through the controller
EVAP FANThe Evaporator Fan turns on when the unit is powered on.The Evaporator Fan is wired to constant powerThe Evaporator Fan turns off when the unit is unplugged or put into standby.The Evaporator Fan is wired to constant power
Some models will be wired to the fan relay (EW+978 - Terminal #3)Some models will be wired to the fan relay (EW+978 - Terminal #3)
LIGHTThe light will turn on when the down button is pressed (or when the door is opened with solid doors)The Light Contact is energizedThe light will turn off when the down button is pressed (or when the door is closed with solid doors)The Light Contact is de-energized
(Ew+978 - Terminal #2)
ConditionCompressorCondenser FanEvaporator FanLights
Cabinet Temp > Set point + 4 ON ON ON ON or OFF
Cabinet Temperature <= Set point - 4 OFF OFF ON ON or OFFOFF
Defrost OFF OFF ON ON or OFF

User Manual for UCRF Refrigerator Freezer Beverage Air

REFRIGERATOR SECTION

Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 1

text_image -8.89 (°) F AUX °C SET

Controller Symbols

Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 2Reduced SET / EconomyPermanently on: Energy Saving ModeFlashing: Reduced Set ModeQuick Flashing: Access to level 2 parametersBeverage-Air UCF32AHC - REFRIGERATOR SECTION - 3AUXPermanently on: Aux ActiveFlashing: Deep Cooling Cycle Active
Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 4CompressorPermanently On: Compressor ActiveFlashing: Delay, protection or blocked start-upBeverage-Air UCF32AHC - REFRIGERATOR SECTION - 5DefrostPermanently on: Defrost ActiveFlashing: Manual or D.I. activation
Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 6AlarmPermanently on: Alarm ActiveFlashing: Alarm AcknowledgedBeverage-Air UCF32AHC - REFRIGERATOR SECTION - 7FanPermanently on: Fans Active
Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 8CelsiusPermanently On: °C SettingBeverage-Air UCF32AHC - REFRIGERATOR SECTION - 9FahrenheitPermanently on: °F Setting

Controller Buttons

Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 10UpPress and release• Scrolls through menu items• Increases ValuesPress for at least 5 seconds• Activates the manual defrostBeverage-Air UCF32AHC - REFRIGERATOR SECTION - 11Stand-byPress and release• Returns to the previous menu level• Confirm parameter valuePress for at least 5 seconds• Activates the stand-by function
Beverage-Air UCF32AHC - REFRIGERATOR SECTION - 12DownPress and release• Scrolls through menu items• Decreases valuesPress for at least 5 seconds• Turn light on/offBeverage-Air UCF32AHC - REFRIGERATOR SECTION - 13Set (Enter)Press and release• Displays alarms• Opens the machine status menuPress for at least 5 seconds• Opens the programming menu• Confirms commands

User Manual for UCRF Refrigerator Freezer Beverage Air

REFRIGERATOR SECTION

Alarms are always indicated by the buzzer (if present) and the alarm icon. To switch off the buzzer, press and release any key, the relative icon will continue to flash.

NOTE: If alarm exclusion times have been set (see AL folder in the parameters table), the alarm will not be signaled.

Alarm CodeTriggerAutomatic ClearanceOutputsComments
"AH1"Pb1 probe HIGH Temperature alarmUser configuredLabel AH1 displayed alternately with the actual value read by the probe Pb1High temperature alarm
"AL1"Pb1 probe LOW Temperature alarmUserLabel AL1 displayed alternately with the actual value read by the probe Pb1Low temperature alarm
"OPd"Door open for more thanAlwaysLabel OPd displayed alternately with the actual value read by probe Pb1Door open alarm
"E1""E1" errorAlwaysBlink "E1". If configured: cut in alarm relay, beep the buzzer"PB1" sensor failure (short or open)
"E2""E2" errorAlwaysBlink "E2". If configured: cut in alarm relay, beep the buzzer"PB2" sensor failure (short or open)
"E3""E3" errorAlwaysBlink "E3". If configured: cut in alarm relay, beep the buzzer"PB3" sensor failure (short or open)
"E4""E4" errorAlwaysBlink "E4". If configured: cut in alarm relay, beep the buzzer"PB4" sensor failure (short or open)

User Manual for UCRF Refrigerator Freezer Beverage Air

CLEANING AND MAINTENANCE

Cleaning Schedule:

CabinetCondenser coilGaskets
Daily wipe downQuarterly cleaningPeriodic
Weekly interiorRoutine maintenance
Annually

Daily Exterior Cleaning

It is much easier to clean on a regular basis than to have to remove stains once they have built up.

  1. Wash with a clean sponge and a mild detergent that does not contain chlorine.
  2. Rinse with clean water.
  3. Dry with a soft cloth.

Weekly Interior Cleaning

  1. Remove all food, food related items, and shelves.
  2. Disconnect power to the cabinet at the main power supply circuit breaker
  3. Remove loose food particles from interior floors, walls, and ceiling
  4. Scrub all interior surfaces and drawer gaskets with a warm (100°-120°F) detergent solution and a soft nylon bristle brush

Gaskets

  1. Visually inspect the door gaskets for a tight seal on all four sides. Inspect for any type of damage such as rips, tears, stiffness, or cracks.
  2. If any such condition exists, the magnet will not seal and the gasket will need replaced.
  3. Cleaning the gasket requires the use of mild dish detergent and warm water.
  4. Next, thoroughly rinse and dry the gasket.

  5. Polish with a soft cloth, wiping with the grain.

  6. Wipe weekly with stainless steel cleaner.

  7. Rinse with clean water and allow to air dry

  8. Re-install the shelves.
  9. Restore power to the cabinet by resetting main power supply circuit breaker
  10. Return food to the cabinet when temperature indicator displays safe food temperature

User Manual for UCRF Refrigerator Freezer Beverage Air

CONDENSER CLEANING

Keeping the condenser coil clean is critical to efficient operation.

The condenser coil is located behind the front or rear grille of the cabinet. It should be inspected once a month and cleaned as required. Vacuum clean all surfaces of the condenser. Make sure no fins are bent or damaged in the process. If there are bent fins, carefully straighten them so that air can flow through the coils. Failure to keep the condenser coil clean will lead to poor performance, excessive power consumption and compressor failure and may result in loss of property. Failure to keep the condenser coil clean may void the limited warranty.

  1. Unplug unit from power supply.

Beverage-Air UCF32AHC - CONDENSER CLEANING - 1

CAUTION

Rotating fan blade can cause personal injury.

Beverage-Air UCF32AHC - CAUTION - 1

natural_image Abstract black-and-white icon depicting a hand holding puzzle pieces with a gear-like shape above (no text or symbols)

Unplug unit from power supply before beginning to clean condenser

  1. Remove the Phillips head screws at the top of the panel.
  2. Once the screws have been removed the you can lower the panel.

Please note the electrical cord will still be connected to the panel.

  1. Examine condenser surface, if dusty, brush and vacuum the dust and lint from the surface of the coil. Brush up and down to avoid damaging the fins. Use care to not disturb the wires connected to the controller.

Note: If the coil is greasy, the coil will need to be cleaned with coil cleaner and that should be left to an experienced technician.

  1. After the condenser is clean, return the grille panel to the unit.

  2. To reinstall line up the bottom of the panel to the bottom of the unit keeping the screw holes lined up on the panel and on the unit

  3. Reinstall the screw on the top of the front grille panel.

Note: Air filters are not recommended as they restrict the flow of cooling air.

Beverage-Air UCF32AHC - CAUTION - 2

text_image Remove These Screws Remove This Panel

Beverage-Air UCF32AHC - CAUTION - 3

text_image ATTENTION ATTENTION ATTENTION Condenser Surface

User Manual for UCRF Refrigerator Freezer Beverage Air

METHODS FOR CLEANING STAINLESS STEEL

Cleaning Needed CleaningAgent Method of Application Affect onFinish
Smears and fingerprintsAreal 20, Lac-O-Nu, Lumin Wash O'Cedar Cream Polish, Stainless Shine.Rub with cloth as directed on the package.Satisfactory for use on all finishes.Provides barrier film to minimize prints.
Stubborn Spots and Stains, Baked-On Splatter, and Other Light DiscolorationsAllchem Concentrated Cleaner.Apply with damp sponge or cloth.Rub with damp cloth.Use in direction of polish lines on No. 4 (polished) finish. May scratch No.2 (mill) and Nos. 7 and 8 (polished) finishes.
Samae, Twinkle or Cameo Copper CleanerRub with damp cloth.
Grade FFF Italian pumice, whiting, or talc.Rub with dry cloth.
Liquid NuSteelPaste NuSteel or DuBois Temp.Copper's Stainless Steel CleanerRevere Stainless CleanerHousehold cleansers, such as Old Dutch, Lighthouse, Sunbrite,Wyandotte, Bab-O, Gold Dust,Sapolio, Bon Ami, Ajax, or Comet Grade F Italian Pumice, Steel Bright, Lumin Cleaner, Zud,Restore, Sta-Clean, or Highlite.Penny-Brite or Copper-Brite.Use small amount of cleaner.Rub with dry cloth using a small amount of cleaner.Apply with damp sponge or cloth.Rub with a damp cloth. May contain chlorine bleaches.Rinse thoroughly after use.Rub with a damp cloth.Rub with a dry cloth using a small amount of cleaner.
Heat tint or discolorationPenny-Brite or Copper-Brite.Past NuSteel, DuBois Temp,or Tarnite. Revere Stainless Steel Cleaner. Allen Polish, Steel Bright,Tenacious Deposits,Rusty Discolorations,IndustrialAtmospheric Stains Wyandotte,Bab-O or Zud.Rub with a dry cloth.Rub with a dry cloth or stainless steel wool.Apply with damp sponge or cloth.Rub with a damp cloth.
Burnt-On Foods and Grease Fatty Acids,Milkstone (where swabbing or rubbing is not practical)Easy-Off, De-Grease-It, 4 to 6% hot solution of such agents as trisodium phosphate or sodium tripolyphosphate or 5 to 15% caustic soda solutionApply generous coating. Allow to stand for 10-15 minutes.Rinse.Repeated application may be necessary.Excellent removal, satisfactory for use on all finishes.
Tenacious Deposits,Rusty Discolorations,IndustrialAtmospheric StainsOakite No. 33, Dilac Texo 12, Texo NY,Flash-Klenz, Caddy Cleaner,Turco Scale 4368 or Permag 57.Swab and soak with clean cloth.Let stand 15 minutes or more according to directions on package, then rinse and dry.Satisfactory for use on all finishes
Hard Water Spots and ScaleVinegar.5% oxalic acid, 5% sulfamic acid, 5 to 10% phosphoric acid, or Dilac, Oakite No. 33, Texo 12, Texo N.Y.Swab or wipe with cloth. Rinse with water and dry.Swab or soak with cloth. Let stand 10-15 minutes. Always follow with neutralizer rinse, and dry.Satisfactory for all finishes.Satisfactory for all finishes.Effective on tenacious deposits or where scale has built up.

User Manual for UCRF Refrigerator Freezer Beverage Air

HELP

Trouble Diagnosis for the User
Malfunction Possible Cause Likely Solution
No cooling - unit is silentUnit not plugged in.Fuse or circuit breaker tripped.Power cord plug loose in outlet.Connect to proper voltage circuit Replace fuse or reset breaker.Check outlet for loose connection, replace as needed
Unit cools but seems to be on all the time Dirty condenser Clean condenser
Space temperature too highDirty condenserEvaporator iced over Unit in high temperature environmentClean condenser Defrost evaporatorReduce temperature of room
Space temperature too low Temperature control Adjust or replace control
Trouble Diagnosis for the Technician
No cooling - compressor does not hum Tempcontrol stuck in open position Replace tempcontrol.
No cooling - compressor hums but does not startLow voltage to unit.Compressor starting system failureCheck voltage, correct as needed. Check start relay and start capacitor. See next step.
No cooling - compressor starts but shuts offCompressor start relay failure Compressor start capacitor failureReplace relay. Replace capacitor.
No cooling - compressor cycles on and off Overheating weak overloadClean condenser, check fan motor and blade. Check refrigerant charge. Replace overload.
Unit cools, but is slow to pull cabinet temperature downEvaporator fan not turningCheck fan(s), on multiple fan units one fan may be turning slowly and will need to be replaced.
Unit cools but turns on and off frequentlyNo product in cabinet. Temperature control defective Refrigeration issueFill cabinet Replace controlHave system checked
Makes excessive noiseTubing rattle Loose partsBent or broken fan blade Noisy fan motorCheck tubing for routing Check for loose components Replace fan bladeReplace fan motor

User Manual for UCRF Refrigerator Freezer Beverage Air

FOR THE SERVICE TECH - R290

Refrigeration service should only be attempted by a trained trade professional certified to work on R290 systems.

Here are some critical service items.

This list does not qualify anyone to service the unit. It is a reminder and checklist for the service tech. Keep these in mind for R290 service:

  • Wire nuts are NOT to be used when changing an electrical part.
  • The switches in this product are sealed, only exact replacements may be used.
  • The process tubes are to be used for service access.
  • Cut out (with tubing cutter) refrigeration components that are to be replaced. Do NOT un-braze.
  • Because R290 can be vented into the air during service, the venting MUST be in an area free from flame or spark. It must be near an opened window or door.
  • A sign noting service of a system containing propane must be attached to the unit during refrigeration service.
  • A combustible gas leak detector must be used to inform anyone in the area when propane is present in the air.

Other Information:

Evacuation: It is critical that a refrigeration system be leak free and internally dry. A thorough evacuation with a good vacuum pump with a micron gauge attached is the only way to ensure that the system is dry and ready for a charge of refrigerant.

Charging: The system is critically charged and the proper type and amount MUST be weighed in.

Overcharge symptoms: Unit will cool properly but the suction line temperature will be unusually cold. Compressor run time will be longer than normal.

Undercharge symptoms: Long run time, poor cooling and a hot compressor dome are the main symptoms of an undercharge.

User Manual for UCRF Refrigerator Freezer Beverage Air

FOR THE SERVICE TECH - WIRING DIAGRAM FOR REFRIGERATOR SECTION - DANFOSS CONTROLLER
Beverage-Air UCF32AHC - User Manual for UCRF Refrigerator Freezer Beverage Air - 1

text_image WHITE BLACK *SEE CONTROLLER DETAIL *SEE CONTROLLER DETAIL *SEE CONTROLLER DETAIL CONTRIL CONDENSER FAN CURRENT RELAY COMP COMPRESSOR DETAIL (115V 1PH) EVAP FANS *NOT ALL MODELS* POWER SUPPLY LAMP LE.D. LAMP *NOT ALL MODELS* LEGEND RC - RUN CAPACITOR SC - START CAPACITOR OL - OVERLOAD © DANFOSS CONTROLLER TERMINAL ● CONNECTION POINT ICRCONTROL RELAY CONDENSER FAN CURRENT RELAY COMP COMPRESSOR DETAIL SOME MODELS COMPRESSOR DETAIL DANFOSS CONTROLLER DETAIL COPPEROSIS SPPLY L SPLIT L LIGHT (LOW) TL MODEL S AIR STINSON EAVP ENSSOR (NOT ALL MODELS) M

User Manual for UCRF Refrigerator Freezer Beverage Air

FOR THE SERVICE TECH - WIRING DIAGRAM FOR FREEZER SECTION - DANFOSS CONTROLLER
Beverage-Air UCF32AHC - User Manual for UCRF Refrigerator Freezer Beverage Air - 1

text_image SEE CONTROLLER DETAIL COMPRESSION DETAIL CONDENSER FAN START RELAY COMP DCI N FACE -FATER DOOR HEATER GLASS DOOR MODELS ONLY SEE CONTROLLER DETAIL EVAP FAN SEE CONTROLLER DETAIL HEATER SAFETY THERMAL SWITCH DEFROST HEATER PAN HEATER ×NOT ALL MODELS* SEE CONTROLLER DETAIL POWER SUPPLY LAMP ×NOT ALL MODELS*

Beverage-Air UCF32AHC - User Manual for UCRF Refrigerator Freezer Beverage Air - 2

text_image COMPRESS CTRLER FOR SOME MODELS CDICEMETER FAN CLIP N S-AM-CTRL COMPRESS CTRLER CTRLER COMPRESS SUPPLY LIFE TYPICAL LIFE-SCALE 0.5V TYPICAL LIFE-SCALE 0.5V

Beverage-Air UCF32AHC - User Manual for UCRF Refrigerator Freezer Beverage Air - 3

User Manual for UCRF Refrigerator Freezer Beverage Air

FOR THE SERVICE TECH - WIRING DIAGRAM FOR REFRIGERATOR SECTION - ELIWELL CONTROLLER

Beverage-Air UCF32AHC - FOR THE SERVICE TECH - WIRING DIAGRAM FOR REFRIGERATOR SECTION - ELIWELL CONTROLLER - 1

text_image WHITE BLACK *SEE CONTROLLER DETAIL CNTR WHITE *SEE CONTROLLER DETAIL CONDENSER FAN CURRENT RELAY COMPRESSOR DETAIL (015V 1PH) CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP ConTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTEMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP CONTMP

User Manual for UCRF Refrigerator Freezer Beverage Air

LIMITED WARRANTY

WARRANTY (Warranty valid in USA and Canada)

THREE (3) YEAR PARTS AND LABOR WARRANTY:

Beverage-Air Corporation warrants to the original purchaser of Beverage-Air branded equipment, including all parts thereof, that such equipment is free from defects in material and workmanship, under normal use, proper maintenance, and service as indicated by Beverage-Air installation and operation instructions, for a period of three (3) years from the date of installation, or thirty-nine (39) Months from the date of shipment from the manufacturer, whichever is earlier.

ADDITIONAL FOUR (4) YEAR COMPRESSOR PART

WARRANTY*: In addition to the warranty set forth above, Beverage-Air warrants the hermetically/semi-hermetically sealed compressor (part only) for an additional FOUR (4) years beyond the first three (3) years warranty period; not to exceed eighty-seven (87) months from the date of shipment from Beverage-Air, provided upon receipt of the compressor, manufacturer examination shows the sealed compressor to be defective. This extended warranty does not cover freight for the replacement compressor or freight for the return of the failed compressor.

* Units shipped after 03/01/2020. Previous warranty applies to units shipped prior.

EXCEPTIONS:

CT96 Models carry a one (1) year parts and labor warranty, limited to fifteen (15) months from date of shipment from Beverage-Air. These are excluded from additional compressor warranty.

SR/SF (Slate) models carry a two (2) year parts and labor warranty, limited to twenty-seven (27) months from date of shipment from the Beverage-Air.

Blast Chillers carry a three (3) year parts and labor warranty; additional two (2) years compressor part only.

Units installed in Residential applications will be not covered under this warranty. Units are intended for Commercial use only.

BEVERAGE-AIR

Also, this extended compressor-part only warranty does NOT apply to any electrical controls, condenser, evaporator, fan motors, overload switch, starting relay, capacitors, temperature control, filter/drier, accumulator, refrigeration tubing, wiring harness, labor charges, or supplies which are covered by the warranty above.

Normal wear type parts, such as light bulbs/lamps and gaskets are not covered by this warranty. For the purpose of this warranty, the original purchaser shall be deemed to mean the individual or company for who the product was originally installed.

Our obligation under this warranty shall be limited to repairing or replacing, including labor, any part of such product, which proves thus defective. Beverage-Air reserves the right to examine any product claimed to be defective.

The labor warranty shall be for self-contained units only and for standard straight time, which is defined as normal service rate time, for service performed during normal working hours. Any service requested outside of a servicer's normal working hours will be covered under this warranty at the normal rate and any additional overtime rate will be at the responsibility of the equipment purchaser.

Any part or accessory determined to be defective in the product should be returned to the company within thirty (30) days under the terms of this warranty and must be accompanied by a record of the cabinet model, serial number, and identified with a return material authorization number (RMA#) issued by the manufacturer.

Special installation/applications, including remote locations, are limited in coverage by this warranty. Any installation that requires extra work, and/or travel, to gain access to the unit for service is the sole responsibility of the equipment purchaser.

Improper operation resulting from factors, including but not limited to, improper or negligent cleaning and maintenance, low voltage conditions, inadequate wiring, outdoor use (unless otherwise specified) and accidental damage are no manufacturing defects and are strictly the responsibility of the purchaser.

User Manual for UCRF Refrigerator Freezer Beverage Air

LIMITED WARRANTY (CONTINUED)

With the exception of Blast Chillers product is designed for maintaining temperature and not bringing food to a desired temperature therefore cannot be held responsible for this function under warranty.

Units must be in a conditioned environment or warranty will be void.

Condensing coils must be cleaned at regular intervals. Failure to do so can cause compressor malfunction and will void warranty. Although cleaning requirements vary in accordance with operation of various products, Beverage-Air recommends a minimum monthly cleaning.

NO CLAIMS CAN BE MADE AGAINST THIS WARRANTY FOR SPOILAGE OF FOOD. PRODUCTS, LOSS OF SALES OR CONSEQUENTIAL DAMAGES.

THE FOREGOING WARRANTIES ARE EXPRESSLY GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HERBY DISCLAIMED, ALL OTHER OBLIGATIONS OR LIABILITIES ON OUR PART, AND WE NEITHER ASSUME, NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US, ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THERE OF.

This warranty shall not be assignable and shall be honored only in so far as the original purchaser. This warranty does not apply outside the limits of the United States of America and Canada, nor does it apply to any part that has been subject to misuse, neglect alteration, accident, or to any damage caused by transportation, flood, fire, acts of terrorism, or acts of God.

LIMITATION OF LIABILITY:

Beverage-Air Corporation or their affiliates shall not be liable for any indirect, incidental, special or consequential damages, or losses of a commercial nature arising out of malfunction equipment or its parts components thereof, as a result of defects in material or workmanship.

THE ORIGINAL OWNER'S SOLE AND EXCLUSIVE REMEDY AND BEVERAGE-AIR'S SOLE AND EXCLUSIVE LIABILITY SHALL BE LIMITED TO THE REPAIR OR REPLACEMENT OF PARTS OR COMPONENTS CONTAINED IN THE EQUIPMENT IDENTIFIED ABOVE WHICH UNDER NORMAL USE AND SERVICE MALFUNCTION AS A RESULT OF DEFECTS IN MATERIAL OR WORKMANSHIP, SUBJECT TO THE APPLICABLE PROVISIONS AND LIMITATIONS STATED ABOVE.

User Manual for UCRF Refrigerator Freezer Beverage Air

Warranty Registration

Register your product online at Beverage Air.com/parts-service or fill out and mail the form below.

Cabinet Model Number: Date Of Installation:

Cabinet Serial Number: ____

Location Of Product

Business Name: ____

Business Street:

Business City: ____ State: ____ Postal Code: ____

Mail to: Beverage Air, 3779 Champion Blvd, Winston-Salem, NC 27105

Rev. 02/23

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Beverage-Air

Model : UCF32AHC

Category : Freezer