USER MANUAL CME1-FTK Macurco
GENERAL SAFETY INFORMATION
Intended Use
This Field Test Kit allows installers to quickly test the CO sensor on site. The CM-E1 design meets the NFPA 720-2009 standard requiring CO sensor functionality and sensitivity testing effective 2012 and 2015 respectively.

WARNING
Each person using this equipment must read and understand the information in these User Instructions before use. Use of this equipment by untrained or unqualified persons, or use that is not in accordance with these User Instructions may adversely affect product performance and result in sickness or death. For proper use see User Instructions or call Macurco in U.S.A., 1-877-367-7891. In Canada, call Technical Service at 1-877-367-7891.
Caution:
- Units to be tested must be powered continuously for a minimum of 3 minutes before proceeding.
- For optimum test results the unit should be in clean air and be in a low ambient air flow. If the unit is reading more than 30ppm it will not go into test mode, but will blink red on the LED and double beep every 15 seconds
- Check that the CM-E1 status indicator light is illuminated, Green continuously. If not, do not proceed with tests. See CM-E1 TROUBLE INDICATOR section.
USER INSTRUCTIONS
Specifications
- CM E1-FTG - Macurco™ Carbon Monoxide Field Test Gas 11L 500ppm CO/Air, Aerosol (for use with CM-E1 CO functionality test)
- CM E1-FTK - Macurco™ Carbon Monoxide Field Verification Gas Kit includes 17L 200ppm CO/Air, regulator, test hood and Tygon® tubing (for use with CM-E1 CO sensitivity test)
Field Test Procedures
CO Functionality Test with =>500ppm and => 10LPM
- Quickly press the TEST/RESET button 5 times. The buzzer will do a quick double beep and the LED will flash Amber alternating with a pause. The units will remain in this mode for 5 minutes or until it passes the quick test.
-
Aim the nozzle of the aerosol can at the buzzer grate area and press for 4 to 5 seconds (Fig. 1).
-
Wait for a few seconds. The LED should blink Green rapidly and the buzzer should double beep every 15 seconds indicating a pass of the quick test. If this does not occur, see CM-E1 TROUBLE INDICATOR section.
- Press the button once to return to normal sensing mode.
CO Sensitivity Test with 200ppm CO and 0.2LPM regulator
- Assemble the gas, regulator and CM-E1 test hood if this has not already been done.
- Quickly press the TEST/RESET button five times. The buzzer will do a quick double beep. Hold the button down for three seconds. The LED will start to slowly blink Amber.
- Lift the front plastic on the CM-E1 until the buzzer is showing (Fig. 2).

natural_image
Close-up of a white plastic electronic component with mounting holes and a lid (no visible text or symbols)Fig. 2
- Insert the CM-E1 test hood onto the end of the sensor just below the buzzer with the printed side of the hood facing the buzzer (Fig. 3).

8. Remove test hood.
CM-E1 TROUBLE INDICATOR
Internal failure of the CM-E1 will cause an open circuit in the normally closed (NC) Trouble Relay to provide for actuation of the control panel circuits. The status LED will flash Amber and the CM-E1 buzzer will emit a short "chirp" every 50 seconds. See CM-E1 ERRORS below. The CM-E1 microprocessor continuously monitors various detector parameters. Failure of the CM-E1's internal power supply or a lack of power to the detector will result in the status light remaining OFF (not illuminated). In this case, the most common cause of detector trouble would be a break in the wiring between the control panel and the CM-E1.
CM-E1 ERRORS
The CM-E1 continuously monitors various internal operating parameters. If a problem is found, the unit will switch to Trouble mode. See CM-E1TROUBLE INDICATOR above. To reset the unit for normal operation, press the TEST/RESET switch, or remove power to the unit, wait a few seconds, then re-apply unit power. If the problem persists, your detector requires repair; contact the alarm panel installer or Macurco Tech Support for advice. If repair is required, return the unit to Macurco to comply with warranty.
CM-E1 TESTING
The CM-E1 should be tested by pushing the TEST/RESET switch; see TEST/RESET switch in CM-E1 ERRORS section above. Normally this will be the only test required for the CM-E1 and is the recommended way to test the unit or units after installation. All CM-E1 units are factory calibrated and 100% tested for proper operation. The unit also has the ability to automatically self test and does so every 2 1/2 minutes. If the unit detects an improper voltage or inoperable component it will default into Trouble mode. See CM-E1 TROUBLE INDICATOR above. Check that the CM-E1 status indicator light is illuminated, Green continuously. If not, do not proceed with the tests.
MACURCO FIXED GAS DETECTION PRODUCTS LIMITED WARRANTY
Macurco, warrants the CM-E1 field test kits will be free from defective materials and workmanship for a period of two (2) years from date of manufacture (indicated on the gas bottle label), provided it is maintained and used in accordance with Macurco instructions and/or recommendations. If any component becomes defective during the warranty period, it will be replaced or repaired free of charge, if the unit is returned in accordance with the instructions below. This warranty does not apply to units that have been altered or had repair attempted, or that have been subjected to abuse, accidental or otherwise. The above warranty is in lieu of all other express warranties, obligations or liabilities. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO A PERIOD OF TWO (2) YEARS FROM THE PURCHASE