Speco Technologies

O2D11M - Security Camera Speco Technologies - Free user manual and instructions

Find the device manual for free O2D11M Speco Technologies in PDF.

📄 21 pages English EN Download 💬 AI Question
Notice Speco Technologies O2D11M - page 11
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about O2D11M Speco Technologies

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Security Camera in PDF format for free! Find your manual O2D11M - Speco Technologies and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. O2D11M by Speco Technologies.

USER MANUAL O2D11M Speco Technologies

2MP 1080p H.265 Indoor/Outdoor

Dome IP Camera

Speco Technologies O2D11M - 1

text_image speca technologies

Directions

Be careful not to cause any physical damage by dropping or throwing the camera. Especially keep the device out of reach from children.

Do not disassemble the camera. No after service is assumed when disassembled.

Use only power adapters compatible with the unit.

Be careful to prevent moisture or water penetration into the unit. Particular attention is needed when installing the unit. The screw holes for the installation screws and pipe should be maintained water light during the whole life time of the product.

All the electrical connection wires running into the unit should be prepared so that water from the outside cannot flow into the unit through the surface of the wires. Penetration of the moisture through the wire for extended period can cause malfunction of the unit or deteriorated image.

Note

This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generate, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is

Revision History

DateRevisionDetails
Oct 26th, 20161.4First manual revision creation.

Contents

  1. Introduction......5

1.1. Overview 5
1.2. Specification....6
1.3. Applications of O2D11M 8

  1. Product Description 9

2.1.Contents....9
2.2. Product Preview 9
2.3. Physical description 10

2.3.1. External View....10
2.3.2. Dimension....10
2.3.3. External Connector 11
2.3.4. Factory Default Switch....11
2.3.5. Camera Control (SW3/SW4) 12

2.4. Functional Description 12

  1. On Site Installation 14

  2. Getting Started....15

4.1. PC Requirement 15

1. Introduction

1.1. Overview

The ONSIP O2D11M is multi-codec (H.265, H.264, MJPEG) IP camera (or network camera) built with embedded software and hardware technology. It enables real time transmission of synchronized video up to 2MP and audio data. Remote clients can connect to IP Camera for the real time video/audio data through various client solutions running on PC or smart device. Real time 2-way communication is available through bidirectional audio communication feature.

H.265 is 40-50% reduction in bitrate at the same visual quality compared to H.264.

Designed to be a stand-alone streaming audio & video transmission device, The Product can be applied to various application area such as video security, remote video monitoring, distance education, video conference or internet broadcasting system.

Vandal proof and weather proof housing will extend the application area to harsh environment of wide temperature range. Embedded PoE (Power over Ethernet, IEEE 802.3af) will enable the owner to reduce TCO (Total Cost of Ownership) by reducing on-site wiring works for the installation.

1.2. Specification

Camera
Image sensor1/3 Inch Progressive scan 2Mega CMOS
effective Pixel1944 x 1092 pixels
Scanning SystemProgressive scan
S/N RatioMore than 50dB(AGC Off)
Lens2.8 ~ 12mm Motorized Varifocal(F 1.4)
Angular of ViewDiagonal 120.8°(W) - 36°(T)
IR LedHigh Power Led 10ea(850nm, 50')
Min Illumination0.2Lux(Color), 0 Lux(IR LED On)
Panning/Tilting RatioPan: 0° ~ 350°; Tilt : 26° ~ 85°
Function
AGCAuto
FlickerlessOn/Off
Shutter speedMax. 1/30,000
White BalanceAWB
WDROn/Off
DNR2DNR, 3DNR Supported
Day & NightAuto(ICR), IR LED
PRIVACY1 Supported
Anti-fogSupported(5 Step)

Factory reset
Supported

Mono Downstream64Kbps G.711 16bit μ-law PCM(Line-out)
Network ProtocolIPv4, TCP, UDP, IGMP, ICMP, ARP, RARP, PPPoE, RTCP, RTP, RTSP, SDP, HTTP, HTTPS, SMTP, FTP, DHCP, UPnP, NTP, DNS, DynDNS
Dynamic IPSupport
Security- User ID & Password protection,- IP address filtering- Digest Authentication, User Access Log
Streaming method- RTSP streaming with proprietary format for control informations- Standard RTSP streaming- HTTP streaming- Onvll Profile-S
Intelligent VideoMotion Detection
Alarm TriggersIntelligent Video + Sensor Input
Alarm EventsVideo file upload(FTP), Still Image(Email), Relay output
Alarm Buffer(Audio/Video)configurable Pre-alarm(5~15 sec) & Post-alarm(10~60 sec)
Client SoftwareSecureGuard#.
General
Operating Temperature14°F ~ 122°F
Operating Humidity0 ~ 80% RH
PowerDC12V, Max. 0.6A, IEEE802.3af PoE
Dimensions(0 x H)∅ 5.27" x 4.68"
Material / IP RatioAL, PC / IP66
WeightApprox. 1.65lb

1.3. Applications of O2D11M

• Security surveillance (buildings, stores, manufacturing facilities, parking lots, banks, government facilities, military, etc.)
- Remote monitoring (hospitals, kindergartens, traffic, public areas, etc.)
• Teleconference (Bi-directional audio conference). Remote Learning, Internet broadcasting
• Weather and environmental observation

2. Product Description

2.1. Contents

The product package contains followings:

ContentsDescriptionRemarks
O2D11MO2D11M main unitSpeco Technologies O2D11M - Contents - 1
AccessoriesScrews & AnchorsSpeco Technologies O2D11M - Contents - 2
L-type wrench, CVBS CableSpeco Technologies O2D11M - Contents - 3
Guide pattern[48HZ]
CDSoftware & User's GuideSpeco Technologies O2D11M - Contents - 4
Power AdaptorDefault built in standard PoE module (IEEE802.3af)12V DC Adaptor(Optional item)

2.3. Physical description

2.3.1. External View

Speco Technologies O2D11M - External View - 1

natural_image Close-up of a modern security camera with a lens and dome (no visible text or symbols)

Figure 2-1. External view of IP Camera

2.3.2. Dimensions

Unit: inch

Speco Technologies O2D11M - Dimensions - 1

2.3.3. External Connector

Speco Technologies O2D11M - External Connector - 1

text_image Sensor Input (white(+), Red(-)) Relay Output (Black(+), Yellow(-)) Network (LAN) Line Output Power Mic/Line Input

Figure 2-3. Connector for external connection

2.3.4. Factory Default Switch

Factory default switch is provided for returning the IP camera to factory default state. The factory default switch can be found by opening the lower body cap of the camera. There are two functions assigned to factory default switch.

  1. Returning to Factory Default State: Press the switch about 5 seconds while power is applied to return to factory default state.
  2. Safe Removal of Micro-SD Card : Press the switch for 1 second to unmount Micro-SD Card for safe

2.3.5. Camera Controls (SW3 / SW4)

Pan / TiltZoom
SW3Speco Technologies O2D11M - Camera Controls (SW3 / SW4) - 1Speco Technologies O2D11M - Camera Controls (SW3 / SW4) - 2
SW4Speco Technologies O2D11M - Camera Controls (SW3 / SW4) - 3Speco Technologies O2D11M - Camera Controls (SW3 / SW4) - 4
Speco Technologies O2D11M - Camera Controls (SW3 / SW4) - 5RIGHTNEARSpeco Technologies O2D11M - Camera Controls (SW3 / SW4) - 6FAR
DOWNWIDEAUTO FOCUS

2.4. Functional Description

• Power : Power input for supplying 12V DC power.

Speco Technologies O2D11M - Functional Description - 1

Caution : If IP Camera is powered by PoE, do not plug in DC Jack with active DC power into DC power connector.

- Network (LAN)

- Relay Output

Relay output is provided for connecting alarm devices or for remote on/off control of devices such as light. Relay is normal open and it will be closed upon alarm annunciation or remote on. The relay is capable of switching 30V AC/DC, 2A. For the application which needs power switching beyond this limit, use additional relay switch as shown in the right of Figure 2-5.

Speco Technologies O2D11M - - Relay Output - 1

flowchart
graph TD
    subgraph Relay
        A["Relay"] --> B["Alarm Out Device"]
        A --> C["Power Supply (-30V) (-2A) (DC/AC)"]
    end
    subgraph Optional Relay Switch
        D["Relay"] --> E["Optional Relay Switch"]
        D --> F["Power Supply (-30V) (-2A) (DC/AC)"]
    end
    G["Power Supply (30V~) (2A~) (DC/AC)"] --> H["Alarm Out Device"]
    G --> I["Power Supply (30V~) (2A~) (DC/AC)"]

* Left : switching requirement below 30V, 2A
* Right : switching requirement higher than 30V, 2A. Apply this connection when either voltage or current exceed the limit.

Figure 2-5. RELAY Output connection

- Sensor Input

Connect external alarm sensor. Examples of sensing devices are infrared sensor, motion sensor, heat/smoke sensor, magnetic sensor, etc. Connect the two wires of the sensors to "SNS In". The sensor type(NC/NO) can be set in admin page. Multiple sensor devices can be connected in parallel.

Speco Technologies O2D11M - - Sensor Input - 1

text_image NO/NC Type Open Collector Type

3. On Site Installation

Use cables and conduits that are suitable for the installation. Particular attention should be paid in the installation so that no moisture is allowed to penetrate into the unit through the cables or conduits during the life time of the product. Products of which the internal parts are exposed to moisture because of improper installation are not covered by warranty

  1. Remove the top cover.
  2. Fix the base on the wall.

Speco Technologies O2D11M - On Site Installation - 1

natural_image Technical line drawing of two mechanical assembly components with no visible text or symbols

4. Getting Started

Brief information for first time operation of O2D11M is provided in this chapter.

4.1. PC Requirement

Audio/Video streaming data received from O2D11M can be displayed or stored in a PC running client programs.

Minimum requirement of the PC is described below:

Minimum RequirementRecommended Specification
CPUIntel Core i3 3GhzIntel Core i7
Main Memory2GB4GB
Operating System*Windows 7Windows 7 (64bit)
Web BrowserInternet Explorer 8 or higherInternet Explorer 8 or higher
Graphic CardVideo RAM 256MBResolution 1920x1080Video RAM 1GBHigher than 1920x1080
Network10 Base-T Ethernet100 Base-T Ethernet

* Operating Systems supported: Windows 2000 Professional, Windows XP / Vista / 7

4.2. Quick Installation Guide

4.2.1. Connect PC and O2D11M to network.

4.2.2. Set IP parameters on O2D11M

Follow the sequence below for setting the IP parameter

i) Run ONSIP installer
ii) Click (1) in ONSIP installer window.> Double click on (2) > Fill in (4) > make a selection in (5) > Fill the parameters in (6)
iii) Click on (9) to apply the settings.
iv) You can connect to admin page by clicking on (10).

Speco Technologies O2D11M - Set IP parameters on O2D11M - 1

text_image Installer MAC Address IP Address Name No Refresh Set Admin Page Reboot Default Adapter About Exit MAC Address Net. Mode Static System Name Web Port RTSP Port Management HTTP Streaming Server Clone MAC Static ADSL(PPPoE) Auto(DHCP) IP Address Subnet Mask Gateway DNS1

4.2.3. Remote video connection to O2D11M

1. Connection through Web Viewer

Web Viewer offers simplest way of video connection to O2iB6. For video connection, enter the IP address of O2iB6 in the URL window of Internet Explorer as:

[e.g.] Port 80

http://172.16.64.133/

Default port 80 can be omitted

[e.g.] Port 8080

http://172.16.64.133:8080/

Speco Technologies O2D11M - Connection through Web Viewer - 1

Note : Active-X module should be installed on your PC before actual connection. If your PC is not connected to the internet, you cannot download Active-X module. Most convenient way of installing the Active-X module is installing Speco-NVR which is available from the CD or our web site.

Speco Technologies O2D11M - Connection through Web Viewer - 2

text_image Connection to Admin Page Basic Control Status SunWave

4.2.4. Additional settings through connection to the Admin Page

All parameters of the camera are factory default out of the box. For a more sophisticated target application, parameters need to be changed through the admin page. The admin page can be connected through

"http://IP_Address:Port_Number/admin.htm"

ID and password of the administrator are required. Default ID and password are "admin". "1234". It is highly recommended to change the ID and password to prevent illegal access to the IP camera. For more detailed information, Please refer to the "Configuration Guide".

5. Troubleshooting

5.1. No power

● In case of Standard PoE (Power over Ethernet)
Power supply through standard PoE is possible only when the following conditions are met.
1. Standard PoE is supported on the product.
2. The LAN switch supports standard PoE.
Make sure that both the IP camera and the LAN switch support standard PoE (IEEE 802.3af)

• In case of DC adaptor

If PoE is not applied, the power and network connection should be made through separate cables. It is recommended to use DC adaptor supplied by provider for the feeding of the power. In case of replacing the DC power supply, make sure that the power supply meets with the power requirement of the IP camera to prevent damage or malfunction.

5.2. Cannot connect to the Video

Check the status of the network connection through PING test.

Try the following on your PC :

  • Start > Run > Cmd > Ping IP address (Ex : Ping 172.16.42.51)
  • If "Reply from \~" message is returned (① in the figure below), the network connection is in normal state. Try connection to the video again. If the problem persists, or refer to other trouble shooting notes.

5.3. Technical Assistance

If you need any technical assistance, please contact technical support. For immediate service please provide the following information.

Speco Technologies O2D11M - Technical Assistance - 1

  1. Model name
  2. MAC address and Registration number
  3. Purchase date
  4. Description of the problem
  5. Error message

Appendix A – Important Notice in Exchanging SD Card (Micro SD)

SD Card is a non-volatile memory device for storing video and audio data on the product. Continued writing to the SD Card will cause wear-off of the memory cell.

When you plug out the SD Card for replacement or other purpose, follow the steps below in order to prevent data loss or crash of the SD Card.

  1. Press factory default button for 1 sec to unmount the SD Card.

- SD Card can also be unmounted by going to Admin Page -> Sensor&Capture Setup and clicking on CONFIRM button at the right of SD Card Unmount menu.

  1. Unplug the SD Card

- If no action is taken within 1 minute, SD Card will be mounted again.

  1. Plug in new SD Card

  2. If the SD Card is a new one for the IP camera, format the SD Card by following through the steps below.

- Go to Admin Page -> Sensor & Capture Setup

- In the SD Card management menu, click on CONFIRM button at the right of SD Card Format.

For more detailed information regarding connection to admin page,

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Speco Technologies

Model : O2D11M

Category : Security Camera