Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine use. U-Line's complete product collection includes modular Wine Captain ^® Models, Beverage Centers, Clear Ice Machines, Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, and Combat ^® Models.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations and attention to even the smallest details. We are known and respected for our unwavering dedication to product design, quality and selection. U-Line is headquartered in Milwaukee, Wisconsin and has shipped product to five continents for over two decades and is proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance Documentation, and Product Warranty information are all available for reference and download at u-line.com.
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following steps:
- U-Line Customer Care must be contacted immediately at +1.800.779.2547.
- Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
SERVICE INFORMATION
Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our Customer Care group directly, contact information below.
This Quick Start Guide covers the basics of installation and general use of your product. For more details, see the complete User Guide & Service Manual on u-line.com.
Contents
1 Safety and Warning
2 Environmental Requirements
2 Electrical
3 Door Swing
4 General Installation
4 Integrated Panel Installation
7 Control Quick Guide
8 First Use
8 Sabbath Mode
9 Warranty

warrantywan
This product is eligible for an additional one-year warranty at no charge when you register your product on u-line.com. See complete warranty for details.
Safety and Warning
NOTICE
Please read all instructions before installing, operating, or servicing the appliance.
Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a Danger, Warning or Caution based on the risk type:
DANGER
Danger means that failure to follow this safety statement will result in severe personal injury or death.
WARNING
Warning means that failure to follow this safety statement could result in serious personal injury or death.
DANGER
This unit contains R600a (Isobutane) which is a flammable hydrocarbon. It is safe for regular use. Do not use sharp objects to expedite defrosting. Do not service without consulting the "R600a specifications" section included in the User Guide. Do not damage the refrigerant circuit.
WARNING
Service must be done by factory authorized service personnel. Any parts shall be replaced with like components. Failure to comply could increase the risk of possible ignition due to incorrect parts or improper service.
Environmental Requirements
This model is intended for indoor/interior applications only and is not to be used in installations that are open/exposed to natural elements.
This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit's ability to reach low temperatures and/or reduce ice production on applicable models.
For best performance, keep the unit out of direct sunlight and away from heat generating equipment.
In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal. The condensation will evaporate when the humidity drops.

CAUTION
Damages caused by ambient temperatures of 40^ F ( 4^ C) or below are not covered by the warranty.
Electrical

WARNING
SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.
Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
Altering, cutting or removing power cord, removing power plug, or direct wiring can cause serious injury, fire, loss of property and/or life, and will void the warranty.
Never use an extension cord to connect power to the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and local codes. This unit requires connection to a
Door Swing
For Integrated models that are installed adjacent to a wall, 1/4" (5 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space for any knobs or pulls installed on the integrated panel/frame.
Stainless Steel models that are installed adjacent to a wall require 2-1/4" (57 mm) door clearance on hinge side to allow for door handle.
Units have a zero clearance when installed adjacent to cabinets.

text_image
1/4" (6 mm) 90° Door Swing Space Required For any Knobs or PullsIntegrated

General Installation
LEVELING INFORMATION
-
Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown.
-
If the unit is not level, remove grille and adjust legs as necessary. Use included tool to adjust the height of the rear legs.

text_image
Technical diagram of a mechanical or electrical enclosure with labeled components and dimensional annotations
text_image
Rotate Front Legs to Adjust Rotate Clockwise to raise near leg. Rotate Counter-Clockwise to lower leg.- Confirm the unit is level after each adjustment and repeat the previous steps until the unit is level.
INSTALLATION
- Plug in the power/electrical cord.
- Gently push the unit into position. Be careful not to entangle the cord.
- Ro-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit's top surface should be approximately 1/8" (3 mm) below the countertop.
- Install the anti-lip bracket.
- Remove the interior packing material and wise out the inside of the unit with a clean, water-dampened cloth.
Integrated Panel Installation
ALL 3000 SERIES EXCEPT DWR
- Fully open door.
- Starting at corner, pull gasket away from door.
- Continue to pull gasket

- The panel should be aligned with the outside edge (opposite the hinge) and high enough to align with the highest point in the door.

text_image
Align Top Of Panel With Highest Point Of Door Align Panel Against Door Edge FirstNOTICE Due to differences in floor construction or surrounding cabinetry, the panel may not sit flush with the top of the door.
- Secure integrated panel to door using clamps. A robust tape may also be used. U-Line recommends the use of bar clamps to secure the panel to the door. If using

text_image
Bar Clamp Door/Drawer WoodNOTICE
It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardwood is installed.
- Locate 6 of the #6x 1-1/2" (38 mm) screws provided with your unit.
- Using a Phillips screwdriver, place one screw into each of the 6 pilot holes and screw down. Do not overtighten screws.
- Ensure the screws sit flush against the bottom of the channel.

Integrated Panel

Integrated Panel
- Remove clamps from door.
NOTICE
If panel requires additional adjustment after removing clamps, slightly loosen each screw and
3000 SERIES DWR
- Fully open drawer.
- The panel should be aligned with the outside edge and high enough to align with the highest point in the drawer.
Align Top Of Panel With Highest Point Of Drawer

text_image
Align Panel Against Drawer Edge FirstNOTICE
Due to differences in floor construction or surrounding cabinetry, the panel may not sit flush with the top of the drawer.
- Secure integrated panel to drawer using clamps. A robust tape may also be used. U- Line racemmandin

NOTICE
It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardwood is installed.
- Locate 12 of the #6x 1-1/2" (38 mm) screws provided with your unit.
- Using a Phillips screwdriver, place one screw into each of the 6 pilot holes and screw down. Do not overtighten screws.


- Remove clamps from drawer.
NOTICE
If panel requires additional adjustment after removing clamps, slightly loosen each screw and adjust panel as necessary. Tighten screws upon completion.
Control Quick Guide
Actual Display: 3018WC

text_image
Up Red Wine 55°F Down Can be displayed in Celsius U-Select Lighting Select PowerActual Display: 30247WC

text_image
Up Zone Indicator Zone Indicator Zone Toggle Select U-LINE Red Wine 55°F White Wine 50°F Down Can be displayed in Celsius Power U-Select LightingActual Display: 3036WCWC, 3036BVWC, 3036RR, 3036RRGL

text_image
Up Zone ToggleZone Select U-LINE Red Wine White Wine 55°F 50°F Down Can be displayed in Celsius Power U-Select LightingActual Display: 3018R, 3018RGL and 3024R, 3024RGL, 3024BFV

text_image
Up U-LINE Down Beverage 38°F Can be displayed in Celsius Select Power U-Select LightingActual Display: 3024DWR

text_image
Up Zone Indicator Zone Indicator Zone Toggle Select U-LINE Beverage 38°F Market 38°F Down Can be displayed in Celsius Power U-Select LightingActual Display: 3024FZR

text_image
Up U-LINE Down Polar 0°F Can be displayed in Celsius Select Power U-Select Lighting| Mode Set Point | °F (°C) | Temperature Range°F (°C) |
| Red Wine 55 (12) 55 | 65 (12-18) | |
| White Wine 50 (10) | 45-55 (7-12) | |
| Sparkling Wine 45 (7) | 38-50 (3-10) | |
| Deli 36 (2) 34-40 (1 | ↑) | |
| Beverage/Drinks 38 | (3) 34-55 (1-18) | |
| Market Fresh 38 (3) | 34-40 (1-4) | |
| Root | 50 (10) 45 | 55 (7-12) |
| Pantry 42 (5) 34-70 | (1-21) | |
| Polar | 0 (-18) | (-5)-5 ([-21]-[-15]) |
First Use
All U-Line controls are preset at the factory. Initial startup requires no adjustments.
NOTICE
U-Line recommends allowing the unit to run overnight before loading with product.
When plugged in, the unit will begin operating under the factory default setting. Follow the on screen prompt for language selection and temperature units.
Sabbath Mode


text_image
U-LINE Up Down Select BE UP TO HER2 SABB-IN MODE MODE?This unit offers a Sabbath mode for users who require this functionality during Sabbaths. Sabbath mode disables system responses to user initiated activities and all external functions, including lighting, display and audible alarms. The unit will still maintain internal temperatures and set points.
To enable Sabbath Mode:
- Open the unit's door to activate the display.
- To access the Customer Menu, hold 38 or 5 seconds.
- Press 🔒 to scroll through available selections.
- Select Sabbath Mode from the Customer Menu by pressing 📄.
U-Line Corporation (U-Line) Limited Warranty
One Year Limited Warranty
For one year from the date of original purchase, this U-Line product warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by U-Line factory authorized service, unless otherwise specified by U-Line. Service provided during normal business hours.
Available Second Year Limited Warranty
Beyond the standard one year warranty outlined above, U-Line offers an extension of the one year warranty coverage for an additional second year from the date of purchase, free of charge. To take advantage of this second year warranty, you must register your product with U-Line within two months from the date of purchase at u-line.com providing proof of purchase.
Five Year Sealed System Limited Warranty
For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by U-Line under the above warranty must be performed by U-Line factory authorized service, unless otherwise specified by U-Line. Service provided during normal business hours.
Terms
These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and maintained in accordance with the U-Line User Guide.
The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or under any warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal rights, and you may also have other rights which vary from state to state.
Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of merchantability or any warranty fit for a particular purpose is limited to the duration of these warranties, and only extends to five years in duration for the parts described in the section related to the five year limited warranty above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.