USER MANUAL 4396033RP AMANA

ELECTRIC DRYER INSTALLATION INSTRUCTIONS 29" WIDE MODELS - U.S.A. ONLY

DRYER SAFETY2
INSTALLATION REQUIREMENTS4
Tools and Parts4
Location Requirements5
Electrical Requirements6
Install Leveling Legs7
Electrical Connection7
VENTING13
Venting Requirements13
Plan Vent System14
Venting Kits14
Install Vent System16
Connect Vent16
Level Dryer16
Complete Installation Checklist16
Reverse Door Swing (Optional)17
Troubleshooting19

DRYER SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

AMANA 4396033RP - Your safety and the safety of others are very important. - 1

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."

These words mean:

DANGER

WARNING

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

AMANA 4396033RP - WARNING - 1

WARNING - "Risk of Fire"

  • Clothes dryer installation must be performed by a qualified installer.
  • Install the clothes dryer according to the manufacturer's instructions and local codes.
  • Do not install a clothes dryer with flexible plastic venting materials or flexible metal (foil type) duct. If flexible metal duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.
  • To reduce the risk of severe injury or death, follow all installation instructions.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions, including the following:

  • Read all instructions before using the dryer.
    ■ Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
    ■ Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
    ■ Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.
    ■ Before the dryer is removed from service or discarded, remove the door to the drying compartment.
    ■ Do not reach into the dryer if the drum is moving.
    ■ Do not install or store the dryer where it will be exposed to the weather.
    ■ Do not tamper with controls.

■ Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
■ Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
■ Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
■ Clean lint screen before or after each load.
- Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.
■ The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.
■ See "Electrical Requirements" located in the installation instructions for grounding instructions.
- Do not install a booster fan in the exhaust duct. NOTE: The booster fan warning does not apply to clothes dryers intended to be installed in a multiple clothes dryer system, with an engineered exhaust duct system that is installed per the clothes dryer manufacturer's guidelines.

SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

When discarding or storing your old clothes dryer, remove the door.

SAVE THESE INSTRUCTIONS

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed:
AMANA 4396033RP - Tools and Parts - 1

AMANA 4396033RP - Tools and Parts - 2
Flat-blade screwdriver #2 Phillips screwdriver

AMANA 4396033RP - Tools and Parts - 3

AMANA 4396033RP - Tools and Parts - 4
Tin snips (new vent installations)

Wire stripper (direct wire installations)
AMANA 4396033RP - Tools and Parts - 5

AMANA 4396033RP - Tools and Parts - 6
Vent clamps

1/4" nut driver (recommended)
AMANA 4396033RP - Tools and Parts - 7

AMANA 4396033RP - Tools and Parts - 8

AMANA 4396033RP - Tools and Parts - 9
Level Caulking gun and

AMANA 4396033RP - Tools and Parts - 10
compound (for installing new exhaust vent)

Parts supplied (all models):
AMANA 4396033RP - Tools and Parts - 11
Leveling legs (4)

Parts package is located in dryer drum. Check that all parts are included.

Parts needed:

Check local codes. Check existing electrical supply and venting, and read "Electrical Requirements" and "Venting Requirements" before purchasing parts.

Mobile home installations require metal exhaust system hardware, available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the "Assistance or Service" section of the "Use and Care Guide".

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

■A UL listed 30 A power supply cord, rated 120/240 V minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

Location Requirements

WARNING

AMANA 4396033RP - WARNING - 1

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (460 mm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

You will need:

■A location allowing for proper exhaust installation. See "Venting Requirements."
■A separate 30 A circuit.
If you are using power supply cord, a grounded electrical outlet located within 2 ft (610 mm) of either side of dryer. See "Electrical Requirements."
■A sturdy floor to support the total weight (dryer and load) of 200 lbs. (90.7 kg). The combined weight of a companion appliance should also be considered.
■Level floor with maximum slope of 1' (25 mm) under entire dryer. (If slope is greater than 1' [25 mm], install Extended Dryer Feet Kit, Part Number 279810.) If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.

Do not operate your dryer at temperatures below 45^ F ( 7^ C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or

Minimum spacing for recessed area or closet installation

The dimensions shown following are for the minimum spacing allowed.

■Additional spacing should be considered for ease of installation and servicing.
■Additional clearances might be required for wall, door, and floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.
■For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■Companion appliance spacing should also be considered.

Minimum Required Spacing
AMANA 4396033RP - Minimum spacing for recessed area or closet installation - 1

text_image 18" (457 mm) 1" (25 mm) 29" (337 mm) A 1" (25 mm) 27/4" (705 mm) 14" (266 mm) B 48 in" (210 cm) 24 in" (155 cm) C 3" (76 mm) 3" (76 mm)

A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents

*Additional spacing recommended

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).

■Metal exhaust system hardware, which is available for purchase from your dealer.

Electrical Requirements

It is your responsibility:

■To contact a qualified electrical installer.

■To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.

The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

■To supply the required 3 or 4 wire, single phase, 120/240 V, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 V electrical supply, if specified on the serial/rating plate) on a separate 30 A circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

■Do not use an extension cord.

■If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

■If local codes do not permit the connection of a neutral bond wire to the neutral wire, see "Optional 3-wire connection" section.

This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral bond wire is permanently connected to the neutral conductor (white wire) within the dryer. If the local electrical codes require the use of a ground-fault circuit interrupter, a 4-wire electrical supply connection is required, the neutral bond wire must be removed from the external ground connector screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral bond wire is secured under the neutral terminal (center or white wire)

■A UL listed strain relief.

If your outlet looks like this:

AMANA 4396033RP - If your outlet looks like this: - 1
4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have 4 10-gauge solid copper wires and match a 4-wire receptacle of NEMA Type 14-30 R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

If your outlet looks like this:

AMANA 4396033RP - If your outlet looks like this: - 1
3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have 3 10-gauge solid copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

■Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), covered with flexible metallic conduit. All current-carrying wires must be insulated.

■10-gauge solid copper wire (do not use aluminum).

■At least 5 ft (1.52 m) long.

GROUNDING INSTRUCTIONS

■ For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock

by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

■ For a permanently connected dryer:

This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding

Install Leveling Legs

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

1. Prepare dryer for leveling legs

AMANA 4396033RP - Prepare dryer for leveling legs - 1

natural_image Diagram of a device with internal components and intersecting planes (no text or symbols)

To avoid damaging floor, use a large flat piece of cardboard from dryer carton; place under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard.

2. Screw in leveling legs

diamond marking

AMANA 4396033RP - Screw in leveling legs - 1

Electrical Connection

Power Supply Cord

WARNING

AMANA 4396033RP - WARNING - 1

Fire Hazard

Use a new UL listed 30 amp power supply cord.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

Electrical Connection Options

1. Choose electrical connection type

AMANA 4396033RP - Choose electrical connection type - 1

Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to steps 1-2 on page 9 for power supply cord strain relief: then steps 3-6 for 4-wire Power Supply Cord Connection section. Then, go to Venting Requirements.

Demon synthetic and 0 mice presented

Direct Wire

WARNING

AMANA 4396033RP - WARNING - 1
Fire Hazard

Use 10 gauge copper wire.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

2. Remove terminal block cover

AMANA 4396033RP - Remove terminal block cover - 1

text_image B C D A

Power Supply Cord Connection

Power supply cord strain relief

1. Attach power supply cord strain relief

AMANA 4396033RP - Attach power supply cord strain relief - 1

text_image A B C D

Remove the screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections (C) into the hole (B) below the terminal block opening so that one tab is pointing up (A) and the other is pointing down (D), and hold in place. Tighten strain relief screws just enough to hold the two clamp sections (C) together.

2. Attach power supply cord to strain relief

AMANA 4396033RP - Attach power supply cord to strain relief - 1

natural_image Diagram showing a hand inserting a plug into a device (no text or symbols present)

Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.

4-wire Power Supply Cord Connection

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

AMANA 4396033RP - 4-wire Power Supply Cord Connection - 1

A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. 3/4" (19 mm) UL listed strain relief
G. Ring terminals

  1. Prepare to connect neutral bond wire and neutral wire
    AMANA 4396033RP - 4-wire Power Supply Cord Connection - 2
text_image Technical diagram of an electrical component with labeled parts A, B, and E

Remove center terminal block screw (B). Remove neutral bond wire (E) from external ground conductor screw (A).

  1. Connect neutral bond wire and neutral wire
  2. Connect ground wire
    AMANA 4396033RP - 4-wire Power Supply Cord Connection - 3
text_image Diagram of an electrical switch or power outlet with labeled components A and F, showing wiring connections and grounding.

Connect ground wire (F) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw.

  1. Connect remaining wires
    AMANA 4396033RP - 4-wire Power Supply Cord Connection - 4
natural_image Simple line drawing of a hand holding a tool inside a device with wires and components (no text or symbols)

Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

3-wire Power Supply Cord Connection

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 1

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 2

text_image 4. Connect neutral wire A B C

Connect neutral wire (white or center) (C) of power supply cord to center terminal block screw (B). Tighten screw.

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 3

text_image 2. Attach direct wire cable to strain relief

Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screws.

For 3-wire Direct Wire Connection, see page 11. For 4 wire Direct Wire Connection, continue to step 3 below.

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 4

text_image 5. Connect remaining wires

Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

4-wire Direct Wire Connection IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit 3-wire connections.

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 5

text_image 3. Prepare your 4-wire cable for direct connection 1" (25 mm) 5° (127 mm)

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer may be moved if needed. Strip 5' (127 mm) of outer covering from end of cable, leaving bare ground wire at 5' (127 mm). Cut 1½' (38 mm) from remaining 2 wires. Strip installation back 1' (25 mm). Shape ends

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 6

text_image 5. Prepare to connect neutral bond wire and neutral wire A B E

Remove center terminal block screw (B). Remove neutral bond wire (E) from external ground conductor screw (A).

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 7

text_image 8. Connect remaining wires

Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 8

text_image 6. Connect neutral bond wire and neutral wire

Connect neutral bond wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of terminal block (B). Squeeze hooked ends together and tighten screw.

3-wire Direct Wire Connection Use where local codes permit connecting cabinet-ground conductor to neutral wire.

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 9

text_image 3. Prepare your 3-wire cable for direct connection 1" (25 mm) 3½" (89 mm)

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer may be moved if needed.
Strip 3 ^1/2 " (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape wire ends into hooks.

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 10

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 11

text_image 6. Connect neutral wire B C

Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw.

AMANA 4396033RP - 3-wire Power Supply Cord Connection - 12

text_image 7. Connect remaining wires

Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

Optional 3-wire Connection You must verify with a qualified electrician that this grounding method is acceptable before connecting.

1. Prepare to connect neutral bond wire and neutral wire

AMANA 4396033RP - Prepare to connect neutral bond wire and neutral wire - 1

text_image 2. Connect neutral bond wire and neutral wire

Connect neutral bond wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center terminal block screw (B). Tighten screw.

AMANA 4396033RP - Prepare to connect neutral bond wire and neutral wire - 2

text_image 3. Connect remaining wires

Place hooked ends of remaining wires under outer terminal block screws (hooks facing right). Tighten screws.

AMANA 4396033RP - Prepare to connect neutral bond wire and neutral wire - 3

text_image 4. Connect external ground wire

VENTING

Venting Requirements

WARNING

AMANA 4396033RP - WARNING - 1
Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: Risk of Fire. Do not install a booster fan in the exhaust duct.

NOTE: The booster fan warning does not apply to clothes dryers intended to be installed in a multiple clothes dryer system, with an engineered exhaust duct system that is installed per the clothes dryer manufacturer's guidelines.

Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

AMANA 4396033RP - WARNING - 2
4" (102 mm) heavy metal exhaust vent

■Only a 4" (102 mm) heavy metal exhaust vent and clamps

Exhaust hoods:

■ Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).

Recommended Styles:
AMANA 4396033RP - Exhaust hoods: - 1
Louvered hood Box hood

AMANA 4396033RP - Exhaust hoods: - 2

Acceptable Style:
AMANA 4396033RP - Exhaust hoods: - 3
Angled hood

Elbows:

■45° elbows provide better airflow than 90° elbows.

AMANA 4396033RP - Elbows: - 1

text_image Good Better

Plan Vent System

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

AMANA 4396033RP - Recommended exhaust installations - 1

text_image A B C D E F G B H

A. Dryer

B. Elbow

C. Wall

D. Exhaust hood

E. Clamps

F. Rigid metal or flexible metal vent

G. Vent length necessary to connect elbows

H. Exhaust outlet

WARNING

AMANA 4396033RP - WARNING - 1

Fire Hazard

Cover unused exhaust holes with a manufacturer's exhaust cover kit.

Contact your local dealer.

Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions.

AMANA 4396033RP - Alternate installations for close clearances - 1

natural_image Diagram of a washing machine with a coiled hose attached to the door, showing internal tubing and a close-up inset (no text or symbols)

Over-The-Top installation (also available with one offset elbow)

AMANA 4396033RP - Alternate installations for close clearances - 2

natural_image Line drawing of a washing machine with a handle and vent, no text or symbols present

Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase.

Venting Kits

For more information, call 1-800-901-2042, or visit us at https://www.whirlpool.com/accessories.html In Canada, call 1-800-807-6777 or visit us at www.whirlpoolparts.ca.

Part Number Descriptions

8171587RP 0-5" Metal vent periscope

4396037RP 0'-18" Metal vent periscope

1000445 101 2011.1.1

Special provisions for mobile home installations:

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

AMANA 4396033RP - Special provisions for mobile home installations: - 1

Determine vent path:

■Select route that will provide straightest and most direct path outdoors.
■Plan installation to use fewest number of elbows and turns.
■When using elbows or making turns, allow as much room as possible.
■Bend vent gradually to avoid kinking.

■Use as few 90° turns as possible.

Determine vent length and elbows needed for best drying performance:

■Use following Vent system chart to determine type of vent material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in Vent system chart. Exhaust systems longer than those specified will:

■Shorten life of dryer.
■Reduce performance, resulting in longer drying times and increased energy usage.

The Vent system chart provides venting requirements that will help achieve best drying performance.

Vent System Chart(Long Vent Models Only)
Number of 90° turns or elbowsType of ventBox/louvered, or Angled hoods
0Rigid metal120 ft (36.6 m)
1Rigid metal110 ft (33.5 m)
2Rigid metal100 ft (30.5 m)
3Rigid metal90 ft (27.4 m)
4Rigid metal80 ft (24.4 m)
5 70 ft (21.3 m)Rigid metal

Install Vent System
AMANA 4396033RP - Determine vent length and elbows needed for best drying performance: - 1

text_image 1. Install exhaust hood 12" minimum (305 mm) 12" minimum (305 mm)

Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.

2. Connect vent to exhaust hood

Connect Vent

  1. Connect vent to exhaust outlet
    AMANA 4396033RP - Connect Vent - 1
natural_image Diagram of a mechanical component with a valve and tubing, no text or symbols present

Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp.

  1. Move dryer to final location
    AMANA 4396033RP - Connect Vent - 2
natural_image Line drawing of a washing machine with a door and front panel, shown in line style (no text or symbols)

Move dryer to final location. Avoid crushing or kinking vent.

NOTE: The dryer must be level for the moisture sensing system to operate correctly.

AMANA 4396033RP - Connect Vent - 3
Not Level

AMANA 4396033RP - Connect Vent - 4
LEVEL

AMANA 4396033RP - Connect Vent - 5
Not Level

  1. Tighten and adjust leveling legs
    AMANA 4396033RP - Connect Vent - 6
natural_image Illustration of a hand using a tool to lift a small cylindrical object, with no visible text or symbols.

If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once legs are level, make sure all four legs are snug against the ground before tightening them.

Complete Installation Checklist

Check that all parts are now installed. If there is an extra part, go back through steps to see what was skipped.
■ Check that you have all of your tools.
■ Dispose of/recycle all packaging materials.
- Check dryer's final location. Be sure vent is not crushed or kinked.
For power supply cord installation, plug into an outlet. For direct wire installation, turn on power.
- Check that down is level. See Ill and Deves"

When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close the door.

If you do not feel heat, turn off dryer, and check the following:

■There may be 2 household fuses or circuit breakers for the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. If there is still no heat, contact a qualified technician.

NOTE: You may notice an odor when the dryer is first healed. This odor is common when the heating element is first used. The odor will go away.

Reverse Door Swing (Optional)

29" Super Wide Side-Swing Door

  1. Place towel on dryer
    AMANA 4396033RP - Reverse Door Swing (Optional) - 1
natural_image Line drawing of a washing machine (no text or symbols)

Place towel on top of dryer to avoid damaging the surface.

NOTE: Magnetized screw driver is helpful.

  1. Remove bottom screws
    AMANA 4396033RP - Reverse Door Swing (Optional) - 2

  2. Lift door off top screws
    AMANA 4396033RP - Reverse Door Swing (Optional) - 3

natural_image Diagram of an open air duct with internal blades and a curved duct (no text or symbols)

Lift door until top screws in dryer cabinet are in large part of hinge slot. Pull door forward off screws. Set door (handle side up) on top of dryer. Remove top screws from dryer cabinet.

  1. Remove screws from hinges
    AMANA 4396033RP - Reverse Door Swing (Optional) - 4
natural_image Line drawing of a washing machine with a close-up inset showing a component detail (no text or symbols)

Remove screws attaching hinges to door.

  1. Remove screws from door
    AMANA 4396033RP - Reverse Door Swing (Optional) - 5
natural_image Line drawing of a front view of a washing machine with circular gauges (no text or symbols)

AMANA 4396033RP - Reverse Door Swing (Optional) - 6

text_image 6. Switch door catch, bezel, & plug Catch and bezel Plug

Remove the door catch, bezel, and plug from the inside of the inner door by squeezing and pulling/pushing them. Place the door catch, bezel, and plug on the sides opposite from where they were.

AMANA 4396033RP - Reverse Door Swing (Optional) - 7

text_image 8. Flip door over

Flip door over so handle side is down.

AMANA 4396033RP - Reverse Door Swing (Optional) - 8

flowchart
graph TD
    A["Rectangle with top block"] --> B["Rectangle with bottom block"]
    B --> C["Rectangle with middle block"]
    C --> D["Rectangle with right block"]
    style A fill:#f9f,stroke:#333
    style B fill:#f9f,stroke:#333
    style C fill:#f9f,stroke:#333
    style D fill:#f9f,stroke:#333

Rotate outer door 180° and set it back down on inner door. Realtach outer door panel to inner door panel so handle is on the side where hinges were just removed. Insert 4 door screws.

AMANA 4396033RP - Reverse Door Swing (Optional) - 9

text_image 9. Attach door hinges

AMANA 4396033RP - Reverse Door Swing (Optional) - 10

text_image 10. Remove door strike and door strike plug Door strike plug Door strike

Remove door strike and door strike plug from dryer cabinet. Insert the door strike into door strike plug hole and secure with screw. Insert door strike plug into original door strike hole and secure with screw.

AMANA 4396033RP - Reverse Door Swing (Optional) - 11

text_image 12. Insert screws in hinge holes on dryer cabinet

NOTE: Two people may be needed to reinstall door. Insert screws into the bottom holes on left side of dryer cabinet. Tighten screws halfway. Position door so large end of door hinge slot is over screws. Slide door up so screws are in bottom of slots. Tighten screws. Insert and tighten top screws in hinges.

AMANA 4396033RP - Reverse Door Swing (Optional) - 12

text_image 11. Remove and transfer hinge hole plugs

Use a small, flat-blade screwdriver to gently remove 4 hinge hole plugs on left side of dryer cabinet. Transfer plugs into hinge holes on opposite side of dryer cabinet.

AMANA 4396033RP - Reverse Door Swing (Optional) - 13

text_image 13. Check door strike alignment
Table of contents Click a title to access it