USER MANUAL TRCD241 JUNG

Room temperature controller

Ref.-no.: TR .. 231 ..

TR .. 241 ..

TR .. 236 ..

TR .. 246 ..

JUNG TRCD241 - Room temperature controller - 1

Operating instructions

1 Safety instructions

JUNG TRCD241 - Safety instructions - 1

Electrical devices may only be mounted and connected by electrically skilled persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Danger of electric shock. Always disconnect before carrying out work on the devise or load.

A relative air humidity of max. 95% may not be exceeded. Avoid any moisture condensation.

These instructions are an integral part of the product, and must remain with the end customer.

2 Structure of the device

JUNG TRCD241 - Structure of the device - 1

text_image Exploded view diagram of a refrigerator with numbered parts for identification

4 Information for electrically skilled persons

Installation and electrical connection

JUNG TRCD241 - Information for electrically skilled persons - 1

DANGER

Electric shock from touching live parts in the installation environment.

An electric shock can be fatal.

Before working on the device, disconnect the power and cover live parts in the area.

  • Mount the room temperature controller on an internal wall opposite the heat source if possible.
  • Do not mount the room temperature controller on outside walls.
  • Avoid draughts from windows and doors.
  • Ensure that the normal air circulation in the room reaches the controller without any obstacles.
  • External heat sources influence the accuracy of the controller. Avoid direct sunlight and do not place heat-emitting devices in the vicinity of the room temperature controller (heaters, lamps, etc.).
  • Dimmers also generate heat.
    If a controller is installed in a common switch frame with a dimmer, the distance between them should be as great as possible. When arranging them vertically, the controller must be installed underneath the dimmer.

Connection

JUNG TRCD241 - DANGER - 1

text_image 10(4)A ERC WWJJ SUNG TR235U D237022500 AC230V~ L N L T T1A ↓ ↓ <0 ↑ ↑ Rf N

Fig.2: TR 231 U

JUNG TRCD241 - DANGER - 2

text_image 10(4)A 5(2)A EAC WWJJ JUNG TR238U DC3702380V AC230V~ L N L W N <0 RF

Fig.4: TR 236 U

JUNG TRCD241 - DANGER - 3

text_image AC1 AC2 AC2 10/4A 5/23A EHC WWJJ SUNG TR246U 24V~ 8246026100 AC1 AC1 AC2 AC2

Fig.5: TR 246 U

- Carry out the electrical connection according to the respective wiring diagram.

i Ensure that the neutral conductor N is connected to terminal N. Considerable fluctuations in temperature may

5 Operation

Restricting the temperature setting range

The temperature controller is set ex works to the maximum setting range of 5 °C to 30 °C.

JUNG TRCD241 - Restricting the temperature setting range - 1
Fig. 6: Temperature setting range

Two adjustment rings are located in the setting knob. You can use these rings to restrict the temperature setting range required e.g. between 8 °C and 23 °C.

Procedure:

- Select the temperature limits.

Example: min 8 °C, max. 23 °C

- Important!

First position the setting knob roughly in the centre of the required setting range.

Example: The centre point between 8 °C and 23 °C is approximately 15 °C.

- Now remove the setting knob.

- Set the red locating ring to the max. temperature limit.

Example: 23 °C

- Rotate anti-clockwise.

The numbers on the outer dial apply!

- Insert the tip of a pen in the hole and turn the red ring to the left until it reaches 23^ (max. scale).

JUNG TRCD241 - Procedure: - 1

Scale for setting the temperature with dials

1 = approx. 5 °C
2 = approx. 10 °C
3 = approx. 15 °C
4 = approx. 20 °C
5 = approx. 25 °C
6 = approx. 30 °C

Symbols

○ Off

I On

6 Technical data

TR 231 U / TR 241 U:

Switching principle 1-pole break contact

+ on/off switch

Temperature range 5 ... 30 °C

Nominal voltage

TR 231 U AC 230 V \~

TR 241 U AC 24 V -

Nominal current* 10 (4) A

Differential of

functioning temperature approx. 0.5 K

Temperature reduction approx. 4 K

Energy class I = 1 %

* The value in brackets indicates the inductive load at a cos φ of 0.6.

TR 236 U / TR 246 U:

Switching principle 1-pole change over contact

without switch

Temperature range 5 ... 30 °C

Nominal voltage

TR 236 U AC 230 V \~

TR 246 U AC 24 V \~

Nominal current*

Healing

10 (4) A