USER MANUAL GOFTR231PL JUNG

Operating Instructions Floor heating controller

JUNG GOFTR231PL - Operating Instructions Floor heating controller - 1

natural_image Two electronic control panel components: one with a dial and knob, the other showing an internal circuit board (no visible text or symbols)

1. Area of application

Used in domestic electrical installations to regulate electrical floor heating systems and temperature control systems.

2. Function

The floor heating controller consists of two parts:

• Control unit for setting the required floor temperature
- Remote sensor in the floor for monitoring the set temperature

Control unit:

Using the setting knob, set the required temperature for your floor. The numbers -6 on the knob correspond to a temperature range of 10 - 50 ^ C.

Note the setting instructions from the manufacturer of your floor heating system.

If the temperature in the floor falls below the temperature you have set, the control unit requests heat; this state is displayed by the red LED above the setting knob. You can therefore see if your heating is using energy.

A range restriction can also be carried out in the setting knob.

The operating state of your floor heating is switched on or off with the mains switch 0 - 1.

You also have the option of programming a temperature reduction via an external time switch e.g. during the night.

If you have installed this type of time switch, the temperature reduction is indicated by the green LED above the setting knob. The temperature reduction is approx. 5 °C.

Example: The temperature set by you on the control unit is 34 ^ (number on dial = 4). This means that the temperature in the floor e.g. during the night can drop down to 29 ^ without your heating switching itself on.

Sensor:

The sensor is to be installed in the floor. It monitors the floor temperature set on the control unit and issues commands to switch the floor heating on and off.

Safety instructions

Electrical equipment may only be installed and fitted by qualified electricians while observing the current accident prevention regulations.

Non-observance of the safety warnings or installation instructions may damage the device, cause fire or other hazards.

In the event of a fault, mains potential can be present at the sensor.

① The switch 0 – I on the control unit causes a singlepole disconnection of the device from the mains and interrupts the circuit to the heating resistor in the floor.
① When working on the load circuit, the mains voltage must be disconnected in principle.
① When the sensor is interrupted, the relay contact is closed. If the sensor experiences a short circuit, the relay contact is open.

3. Connection and installation

Control unit

Mount the control unit in a switch box in accordance with DIN 49 073.

Notice! The device must always be mounted with its supporting frame on top of the wallpaper!

- Carry out the electrical connection according to the wiring diagram (Fig. (1)). Solid conductor cross-section: 1 to 2.5 mm2 No PE conductor required. PE conductor is only used for looping through. Protection class II can be achieved through appropriate installation measures.

Abb.1

JUNG GOFTR231PL - Control unit - 1

text_image L N Netz 0/I L N 230 V~ U - NTC TA Last

Symbols used in the wiring diagram

L : L conductor

N : N conductor

TA : Connection for clock signal for temperature reduction

← : Load connection

NTC : Connection for remote sensor

  • Mount the control unit with the screws supplied.
  • Place the center plate together with the frame on the flush insert. The center plate must snap in place in the top left of the housing base.
  • Tighten the screw (A in Fig. (2)).
  • Clip on the setting knob (B).

Abb.2
JUNG GOFTR231PL - Control unit - 2

text_image Technical diagram of a mechanical assembly with labeled parts A, B, and numbered components 1 to 8

4. Sensor

The sensor must be laid in a conduit. It is thereby protected against damp and can easily be replaced in the event of a repair.

Dimension drawing of remote sensor: Fig. (3).

JUNG GOFTR231PL - Sensor - 1

text_image 4 m 40 Ø 8,5 Ø 5,9

5. Restricting the temperature setting range

The controller is set ex works to the maximum setting range of *to 6. There are 2 adjustment rings (Fig. (4)) in the setting knob which have a setting range of 5 to 30 °C. When restricting the range, we ask you to carry out the setting according to the diagram (Fig. (5)):

Temperature Management Floor heating controller

Ref.-no.: ..FTR 231 ..

JUNG GOFTR231PL - Restricting the temperature setting range - 1

text_image Diagram of a mechanical gear or dial with numbered components and directional arrow indicating rotation or movement.

JUNG GOFTR231PL - Restricting the temperature setting range - 2

text_image min 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80

b.4
JUNG GOFTR231PL - Restricting the temperature setting range - 3

line | z (°C) | x | |---|---| | 10 | 5 | | 18 | 10 | | 26 | 15 | | 34 | 20 | | 42 | 25 | | 50 | 30 |

Abb.5

x = restricting the range in the setting knob y = setting range of the controller z = sensor temperature °C

6. Technical data

The controller corresponds to DIN EN 60 730 type 1 and has radio interference suppression in accordance with VDE 0875 or EN 55 014.

6.1. Control unit

Operating voltage AC 230 V\~ 50/60 Hz

Temperature setting range

(dial)

※ ...6 (= 10 ... 50 °C)

Switching current

Switching capacity 2.3 kW

Red LED Control unit requires heat (heating mode)

Green LED Temperature reduction "on"

Contact (relay) 1 make contact (for heating), (non-floating)

Temperature reduction (TA) approx. 5 K

Differential in switching

temperature approx. 1 K

Protection type of housing

acc. to EN 60529 IP 30

Operating temperature 0...+40 °C

Storage temperature -25...+70 ^

6.2. Remote sensor

Sensor element NTC

Sensor cable PVC, 2 x 0.75 mm², 4 m

Protection type acc. to

EN 60529 IP 67

Operating temperature -20...+70^

Storage temperature -20+70^

Subject to change without further notice.

The sensor cable can be extended up to 50 m if required using a 2-core cable with a cross-section of 1.5 mm ^2 , without influencing the accuracy of the controller.

When laying in cable trunking or in the vicinity of power cables, a shielded cable should be used.

6.3. Sensor characteristic values

Measuring device Ri > 1 MΩ

Ratio temperature to resistance: see table in Fig (6).

The resistance values can only be measured with a disconnected sensor.

Temperature °C Resistor kΩ

0585,279
1066,785
1552,330
2041,272
2533,000
3026,281
3521,137
4017,085
4513,846
5011,277

The resistance values can only be measured with a disconnected sensor.

7. Guarantee

Our products are under guarantee within the scope of the statutory provisions.

Please return the unit postage paid to our central service department giving a brief description of the fault:

ALBRECHT JUNG GMBH & CO. KG

Service-Center

Kupferstr. 17-19

D-44532 Lünen

Service-Line: 0 23 55 . 80 65 51

Telefax: 0 23 55 . 80 61 89

CE The CE sign is a free-trade mark intended solely for state authorities and does not contain any assurance of properties.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : JUNG

Model : GOFTR231PL

Category : Switch