Product Type Universal 2-gang dimmer insert (Light Management)
Brand JUNG
Model ME1565.07
Intended Use Switching and dimming incandescent lamps, HV halogen lamps, dimmable inductive transformers, and Tronic transformers with halogen lamps
Number of Outputs 2 (a1 and a2), independent
Mounting In appliance box to DIN 49073
Power Rating per Output at 25°C Up to 350 W/VA (asymmetric distribution possible, see manual table)
Power Reduction at 35°C Max. 240 W/VA per output
Power Reduction at 45°C Max. 220 W/VA per output
Connection Cable Cross-section Single stranded max. 4 mm²
Max. Total Cable Length 100 m (extension and power cable each)
Dimming Principle Automatic setting: phase cut-off for ohmic/capacitive loads, phase cut-on for inductive loads
Protection Features Electronic short-circuit protection (permanent switch-off after 7s), electronic over-temperature protection, bulb-preserving soft start
Extension Compatibility 2-wire extension (Art.-No. 1220 NE), unlimited number, total cable length max. 100 m
Load Compatibility Mixed loads allowed, but no mixed Tronic and inductive transformers on same output; ohmic-inductive mix max 50% ohmic
Accessories Centre plate Art.-No. ..1565.07.., Satellite insert 2-wire Art.-No. 1220 NE
Safety Install only by skilled electricians; disconnect power before work; do not operate without cover; use only safety transformers (EN 61558-2-6)
Warranty As provided by law; send defective unit to ALBRECHT JUNG GMBH & CO. KG
Dimensions (approx.) 71 x 71 x 41 mm (standard for DIN 49073)
Weight (approx.) 0.1 kg

Frequently Asked Questions - ME1565.07 JUNG

Can I use this dimmer with LED lamps?
The manual specifies compatibility with incandescent lamps, HV halogen lamps, and dimmable inductive or Tronic transformers with halogen lamps. It does not mention LEDs. For LED compatibility, consult the manufacturer or use only if LEDs are explicitly dimmable and compatible.
How do I save the switch-on brightness?
Switch on the light and adjust to the desired brightness. Then press the button for longer than 3 seconds. The lighting will briefly switch off and on as confirmation. Separate switch-on brightnesses can be saved for outputs a1 and a2.
What is the maximum load per output?
At 25°C, the maximum load per output is 350 W/VA, but with asymmetric distribution. For details, refer to the load distribution table in the manual. At higher temperatures, the maximum is reduced (e.g., 240 W/VA at 35°C).
Can I connect multiple extension units?
Yes, the number of 2-wire extension units is unlimited, but the total cable length of all extensions must not exceed 100 m. Only 2-wire extensions (Art.-No. 1220 NE) are supported; installation buttons cannot be used as extensions.
What happens if the load is defective?
The dimmer has electronic short-circuit protection that permanently switches off after 7 seconds. Additionally, defective loads should be replaced immediately as the overheating protection is no longer effective when the load is defective.
Is the dimmer suitable for mixed loads?
Yes, mixed loads are possible on the two outputs, but not on the same output for Tronic and inductive transformers. For ohmic-inductive mixed loads, the ohmic proportion must not exceed 50% to avoid incorrect calibration.
Can I operate output a2 alone?
No. The electronic overheating protection is only active when output a1 is also active. Operating output a2 alone can destroy the device. Always ensure output a1 is in use or connect a load to it.
How do I reset the dimmer after a short circuit?
The dimmer permanently disconnects after a short circuit due to an internal fuse. It cannot be reset; the dimmer must be replaced if defective.
What type of transformers can be used?
Only safety transformers according to EN 61558-2-6 may be used. For inductive transformers, each must be fused on the primary side per manufacturer's instructions.
Does the dimmer have a soft start?
Yes, it features a bulb-preserving soft start to extend lamp life.

User questions about ME1565.07 JUNG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Dimmer in PDF format for free! Find your manual ME1565.07 - JUNG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ME1565.07 by JUNG.

USER MANUAL ME1565.07 JUNG

Operating instructions

1 Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Do not operate the device without a cover.

Danger of electric shock. Always disconnect before carrying out work on the devise or load. At the same time, take into account all circuit breakers that supply dangerous voltage to the device or load.

Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load is not electrically isolated from the mains even when the device is switched off. Fire hazard. For operation with inductive transformers, each transformer must be fused on the primary side in accordance with the manufacturer's instructions. Only safety transformers according to EN 61558-2-6 may be used.

Exchange defective load on output a1 immediately, because the overheating protection is no longer provided when the load is defective. Device can be damaged. These instructions are an integral part of the product, and must remain with the end customer.

2 Device components

(1) (2) (3)

3 Function

Intended use

- Switching and dimming of incandescent lamps, HV halogen lamps and dimmable inductive transformers or Tronic transformers with halogen lamps

- Suitable for mixed load up to the specified output (see chapter 6.1. Technical data)

- Suitable for luminaire groups via the two independent outputs a1 and a2

- Installation in appliance box to DIN 49073

- Operation with suitable cover (see chapter 6.3. Accessories)

i No mixed-load operation of Tronic and inductive transformers on the same output.

Product characteristics

- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest

- Electronic over-temperature protection

- Bulb-preserving soft start

- Power extension through power boosters (see power booster instructions)

- Different load types are possible on the two outputs

- Asymmetric load distribution possible

- Automatic setting of the dimming principle suitable for the load

- Connection of more than one 2-wire extension is possible (see Accessories section)

i The connection of installation buttons as extensions is not possible. This will not function.

Load type Electrical behaviour Dimming principle
Incandescent lamps ohmic Phase cut-off
HV halogen lamps ohmic Phase cut-off
Tronic transformers with halogen lampscapacitive Phase cut-off
Dimmable inductive transformers with halogen lampsinductive Phase cut-on

i Flickering of the connected lamps due to undershoot of the specified minimum load or through centralised pulses from the power stations. Brief flickering upon load detection of ohmic loads. No operation is possible during load detection. These are not device faults.

Light Management

Universal 2-gang dimmer insert

JUNG ME1565.07 - Universal 2-gang dimmer insert - 1

The button field is subdivided into two areas:

- Left: operation of output a1

- Right: operation of output a2.

i A 2-wire extension is always used to operate both outputs simultaneously.

Switching on the light

■ Press button at top for less than 0.4 seconds.
i The light is switched on using the stored switch-on brightness.

Switching the light off

■ Press button at bottom for less than 0.4 seconds.

Adjust the brightness

Light is switched on.

■ Press up or down button until the desired brightness is reached.

Switching the light on with minimum brightness.

Light is switched off.

■ Press button at bottom for longer than 0.4 seconds.

Save switch-on brightness

i Separate switch-on brightnesses can be saved for outputs a1 and a2. In the state as supplied the maximum switch-on brightness is saved.

Light is switched on.

■ Set light to the required brightness.
■ Press button for longer than 3 seconds.

Switch-on brightness is saved.

The lighting switches briefly off and on again as confirmation.

5 Information for electrically skilled persons

JUNG ME1565.07 - Information for electrically skilled persons - 1

CAUTION!

Electronic overheating protection only with active output a1.

Operation without electronic overheating protection can destroy the device.

Never operate output a2 alone.

Connecting and mounting the dimmer

JUNG ME1565.07 - CAUTION! - 1

Figure 3: Connection diagram

(1) Dimmer
(5) 2-wire extension
(6) to additional extensions
i Output a1 can also be operated alone.
i Pav attention to load distribution when an output is loaded with more than 260 W/VA/see

Light Management

Universal 2-gang dimmer insert

JUNG ME1565.07 - Universal 2-gang dimmer insert - 1

i Power specifications including transformer power dissipation.
For ohmic-inductive mixed load, maximum 50% proportion of ohmic load. Otherwise incorrect calibration of the dimmer may result.

Load distribution at 25 °C

Output a1 Output a2
350 W/VA 50 W/VA
310 W/VA 140 W/VA
290 W/VA 200 W/VA
260 W/VA 260 W/VA
200 W/VA 290 W/VA
140 W/VA 310 W/VA
50 W/VA 350 W/VA

Power reduction

per output at 35°C max. 240 W/VA

per output at 45°C max. 220 W/VA

when installed in wooden or dry construction

walls

when installed in multiple combinations -20 %

Connection

Single stranded max. 4 mm²

Number of extension units unlimited

Total length of extension unit cable max. 100 m

Total length power cable max. 100 m

JUNG ME1565.07 - Universal 2-gang dimmer insert - 2

The symbols used to label the dimmer load shows the load type that can be

connected to a dimmer and the electric behaviour of a load:

R = ohmic, L = inductive, C = capacitive

6.2 Troubleshooting

Light Management

Universal 2-gang dimmer insert

JUNG ME1565.07 - Troubleshooting - 1

Dimmer is defective and has been disconnected from the mains permanently by internal fuse. Exchange dimmer.

6.3 Accessories

Centre plate for universal 2-gang dimmer insert Art.-No.: ..1565.07.. Satellite insert 2-wire Art.-No.: 1220 NE

6.4 Warranty

We reserve the right to make technical and formal changes to the product in the interest of technical progress.
We provide a warranty as provided for by law.
Please send the unit postage-free with a description of the defect to our central customer service office:

ALBRECHT JUNG GMBH & CO. KG Service Center Kupferstr. 17-19 D-44532 Lünen Service-Line: +49 (0) 23 55 . 80 65 51 Telefax: +49 (0) 23 55 . 80 61 89 kundencenter@jung.de

General equipment

Service-Line: +49 (0) 23 55.80 65 55 Telefax: +49 (0) 23 55.80 62 55 kundencenter@jung.de

KNX equipment

Service-Line: +49 (0) 23 55.80 65 56 Telefax: +49 (0) 23 55.80 62 55 kundencenter@jung.de

The C€ symbol is a free trade symbol, which is solely intended for the authorities and does not guarantee any properties.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : JUNG

Model : ME1565.07

Category : Dimmer