Caple

CGC711BK - Range hood Caple - Free user manual and instructions

Find the device manual for free CGC711BK Caple in PDF.

📄 20 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Caple CGC711BK - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Range hood
Brand Caple
Model CGC711BK
Color Black
Installation Type Built-in / Under cabinet
Width 60 cm (approx.)
Depth 50 cm (approx.)
Height 15 cm (approx.)
Weight 12 kg (approx.)
Power Supply 220-240 V, 50 Hz
Motor Power 200 W (approx.)
Lighting LED lights
Number of Speeds 3 speeds
Extraction Rate (max) 600 m³/h (approx.)
Noise Level (max speed) 65 dB (approx.)
Filter Type Aluminum grease filter
Charcoal Filter Optional (sold separately)
Control Type Electronic push buttons
Duct Diameter 150 mm (approx.)
Energy Class B (approx.)
Annual Energy Consumption 80 kWh (approx.)
Safety Features Auto shut-off, overload protection
Cleaning Grease filters dishwasher safe
Warranty 2 years (standard manufacturer warranty)

Frequently Asked Questions - CGC711BK Caple

How do I install the Caple CGC711BK range hood?
Ensure the hood is at least 65 cm above gas hobs and 50 cm above electric hobs. Use the included template for drilling, connect the duct to the exhaust, and secure the hood. Always follow the user manual for detailed steps.
How often should I clean the grease filters?
Clean the aluminum grease filters every 2-3 months, or more often if you cook frequently. They are dishwasher safe; dry them thoroughly before reinstalling.
Does the CGC711BK require a charcoal filter?
If you are using the hood in recirculation mode (without external ducting), you need to install a charcoal filter (sold separately). For ducted mode, no charcoal filter is required.
What is the maximum extraction rate?
The maximum extraction rate is approximately 600 m³/h at the highest speed setting.
How do I replace the LED lights?
The LED lights are built-in. If they fail, contact Caple customer service or a qualified technician for replacement; they are not user-replaceable.
Can I use the hood without ducting?
Yes, you can use it in recirculation mode with a charcoal filter. The air is filtered and recirculated back into the kitchen.
What are the dimensions of the CGC711BK?
The approximate dimensions are: width 60 cm, depth 50 cm, height 15 cm. Check the exact measurements in the user manual before cutting cabinets.
How do I reset the filter alarm?
After cleaning the filters, press and hold the speed button or a specific reset button (refer to manual) for 3 seconds until the alarm light turns off.
What should I do if the hood is noisy?
Check that the ducting is properly connected and not blocked. Ensure the filters are clean and securely fitted. If noise persists, contact support.
Is the warranty valid for self-installation?
Yes, if installed correctly according to the manual. However, installation by a qualified electrician is recommended. Keep proof of purchase for warranty claims.

User questions about CGC711BK Caple

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Range hood in PDF format for free! Find your manual CGC711BK - Caple and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CGC711BK by Caple.

USER MANUAL CGC711BK Caple

natural_image Exterior view of a modern stainless steel HVAC unit with a canopy cover (no text or symbols visible)

CONTENTS

Introduction 3

Safety Instructions 4

Environmental Protection 9

Installation 10

Operation 15

Care and Maintenance 16

Troubleshooting 18

Product Dimensions 19

Caple Contact Details 20

INTRODUCTION

Thank you for choosing this Caple extractor hood.

To ensure that you get the best results from your new extractor, we strongly suggest that you read this instruction manual thoroughly before use. If treated with care, your Caple extractor should give you years of trouble-free use.

To register ownership, please ensure you complete and return the guarantee card supplied with the appliance or visit www.caple.co.uk and register here.

This instruction manual is designed to provide you with all the required information related to the installation, use and maintenance of the appliance.

This hood is designed to extract unpleasant odours from the kitchen; it is not intended to extract steam. In order to operate the unit correctly and safely, please read this instruction manual carefully before installation and use.

The cooker hood uses high quality materials and is made with a streamlined design. Equipped with an electric motor and centrifugal fan, it provides strong extraction with low noise. It also features non-stick grease filters and an easy installation.

IMPORTANT

This appliance must only be used for the purpose it is intended. Other types of use are not permitted and may prove dangerous. Caple will not be held liable for any damage caused by the incorrect use of the appliance.

Do not use any accessories or attachments not recommended by Caple as this may result in fire, electric shock or injury.

To protect against fire, electrical shock and injury to persons, do not immerse cords or plugs in water or any other liquid.

Never touch the appliance with wet or damp hands.

Never pull the power cable as you could damage it. If the appliance is faulty, do not attempt to repair it. Isolate it from the mains electric supply and contact Caple Service either by phone 0117 938 7420 or email service@caple.co.uk

Keep all packaging (including plastic bags, polystyrene foam etc) out of the reach and away from children.

Do not rest large or unstable objects on any part of the appliance.

IMPORTANT

Caple cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that Caple reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance. Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualified personnel.

SAFETY INSTRUCTIONS

  • Never let children operate the machine.
  • The cooker hood is for home use only, not suitable for barbecuing, restaurants or other commercial purposes.
  • The cooker hood and its filter should be cleaned regularly in order to keep in good working condition.
  • Clean the cooker hood according to the instruction manual to reduce the risk of fire.
  • When using a gas hob, do not leave naked flames under the extractor.
  • Before connecting this appliance check that the power supply cord is not damaged.
  • If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the sealed or balanced flue type. If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room.

- The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.

- Regulations concerning the discharge of air have to be conformed to.

- Do not flambé under the cooker hood.

- Never leave frying pans unattended during use as overheated fats and oils may catch fire.

- To ensure the best performance, we recommend switching on the extractor 15 minutes before cooking and leave it running 15 minutes after. This will ensure that the air in the kitchen is being circulated before cooking commences and the air is being cleaned after cooking has finished.

- The performance of your extractor will vary depending on a number of factors. These include type of extraction, room volume, length of ducting, ventilation available and the cleanliness of the filters.

- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

- Children should be supervised to ensure that they do not play with the appliance.

- Cleaning and user maintenance must not be made by children without supervision.

  • Never immerse the appliance in water.
  • This appliance is intended to be used in household and similar applications such as:

Staff kitchen areas in shops, offices and other working environments.
Farm Houses.
By clients in hotels, motels and other residential type environments.
Bed and breakfast type environments.

  • To avoid all risk, if the power cable is damaged, it must only be replaced by a Caple appointed engineer.
  • Appliances can be used by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children must not play with this appliance.
  • When not in use and before cleaning, always isolate the appliance from the electrical supply.

ELECTRICAL SHOCK HAZARD

  • Only plug this unit into a properly earthed outlet. If in doubt seek advice from a suitably qualified engineer.
  • Failure to follow these instructions can result in death, fire, or electrical shock.
  • This appliance must be connected to the mains by a competent person. We recommend that the appliance is connected by a qualified electrician who is a member of the N.I.C.E.I.C who will comply with the I.E.E and local regulations. Electrical information can be found on the rating plate.

Caple CGC711BK - ELECTRICAL SHOCK HAZARD - 1

ENVIRONMENTAL PROTECTION

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice. This appliance is marked according to the European directive on Waste Electrical and Electronic Equipment (WEEE).

By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The symbol on the product indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal.

For more detailed information about treatment, recovery and recycling of this product, please contact your local council, your household waste disposal service or the retailer where you purchased the product

WARRANTY

Your new appliance is covered by warranty. The warranty card is enclosed - if it is missing, you must provide the following information to your retailer in order to receive a replacement: date of purchase, model and serial number. Registration can also be completed online by visiting www.caple.co.uk.

Ensure you keep your warranty card safe, you may need to show it to Caple Service together with proof of purchase. If you fail to show your warranty card you will incur all repair charges.

Spare parts are only available from Caple Service and spare parts authorised centres.

CE DECLARATIONS OF CONFORMITY CE

This appliance has been manufactured to the strictest standards and complies with all applicable legislation, Low Voltage Directive (LVD) and Electromagnetic Compatibility (EMC).

UKCA DECLARATIONS OF CONFORMITY

Caple CGC711BK - UKCA DECLARATIONS OF CONFORMITY - 1

This appliance has been manufactured to the strictest standards and complies with all applicable legislation.

TECHNICAL FICHE

This appliance conforms to all current and applicable energy regulations. To view the Technical Fiche that supports the energy labelling data, please visit the product page on our website www.caple.co.uk

INSTALLATION

PREPARE FOR THE INSTALLATION:

Caple CGC711BK - PREPARE FOR THE INSTALLATION: - 1

natural_image Diagram of a mechanical or fluidic system with directional arrows indicating flow or movement (no text or symbols)

If you have an outlet to the outside, your cooker hood can be connected as per the below picture by means of an extraction duct with an interior diameter of 150mm.

Caple CGC711BK - PREPARE FOR THE INSTALLATION: - 2

text_image Earthshed Outlet Box Earthshed Outlet Earthshed Plug

Before installation, turn the unit off and unplug it from the outlet.

Caple CGC711BK - PREPARE FOR THE INSTALLATION: - 3

text_image 65cm - 76cm

The cooker hood should be placed at a minimum distance of 65\~76cm above the hob. It is the manufacturer of the hob who determines the clearance required and the clearance quoted by the hob manufacturer must be followed. In the absence of any instructions supplied with a gas hob the minimum distance between the hob and the hood must be at least 760mm.

INSTALLATION - DUCTED

WARNING:

Observe the warning concerning the operation of the appliance when air is discharged from the room.

When the cooker hood and appliance supplied with energy other than electricity are simultaneously in operation, the negative pressure in the room must not exceed 4 Pa ( 4 × 10^-5 Bar).

Drill 3 x 8mm holes to accommodate the bracket. Screw and tighten the bracket onto the wall with the screws and screw plugs provided.

Caple CGC711BK - WARNING: - 1

text_image Holes on Wall Screw Plug Wall Bracket Screw (4mm x 30mm)

Level up the cooker hood and hang onto the wall bracket hook.

Caple CGC711BK - WARNING: - 2

text_image Wall Bracket Cooker Hood d

After hanging the hood on the bracket, remove the grease filters, mark 2 holes inside the hood for safety screws. After marking, remove the hood, drill two holes and insert 2 wall plugs and finally fix the safety screws with 2 screws (ST4x30mm).

Caple CGC711BK - WARNING: - 3

text_image 1. ST4 x 30mm screws 2. Wall plugs 3. Extractor back panel 4. Safety screw holes

Fix the one-way-valve to the air outlet of the cooker hood. Then, attach the exhaust pipe onto the one-way-valve as shown below.

Caple CGC711BK - WARNING: - 4

text_image Exhaust Pipe Cooker Hood

CHIMNEY INSTALLATION

The lower chimney bracket is used to fix the upper decorative chimney and lower decorative chimney. Use 2pcs 4x8mm screws to attach lower chimney and lower chimney bracket together. Put the lower chimney on the cooker hood and mark the location of lower chimney bracket fixing holes on the wall.

NOTE:

Do not fasten screws too much, make sure upper decorative chimney can be telescopically adjusted after assembled.

Caple CGC711BK - NOTE: - 1

text_image Upper Chimney (Inner) Lower Chimney bracket Lower Chimney (Outer)

Put the chimney on the cooker hood. Fix the lower chimney bracket on the wall by 2 screws (4mm x 30mm).

Then pulling out the upper chimney upwards to the target height. Adjust to reach the height required.

Fix the upper chimney on the upper chimney bracket by 2 screws (4x8mm). Then fix the upper chimney bracket on the wall. Before fixing the bracket on the wall, you can decide the upper chimney bracket fixing holes for installation.

Caple CGC711BK - NOTE: - 2

text_image Wall Plug Plate || Screw (4mm x 8mm) Screw (4mm x 30mm)

INSTALLATION - RECIRCULATION MODE

If you do not have an outlet to the outside, the exhaust pipe is not required (as shown in the section "Installation - ducted"), and charcoal filters must be installed.

Caple CGC711BK - INSTALLATION - RECIRCULATION MODE - 1

natural_image Diagram of a mechanical or fluid system with directional arrows indicating flow or movement (no text or symbols)

INSTALLING THE CHARCOAL FILTER (CAP75CF)

An activated charcoal filter can be used to trap odours. In order to install the charcoal filter, the grease filter should be detached first. Press the release button and pull it downward as shown below.

To fit the charcoal filter, line up part A of the charcoal filter with the rear bar, and part B of the

Caple CGC711BK - INSTALLING THE CHARCOAL FILTER (CAP75CF) - 1

natural_image Two-step diagram showing hand positioning of a flat surface with arrows indicating movement (no text or symbols)

filter with the front of the hood. Push the filter into this space to secure it. There are 2 clips on part B which lock the filter into place once it has been pushed in.

After assembly, the charcoal filter should be as below:

NOTE:

Make sure the filter is securely fitted. Otherwise, it could loosen and fall out. This could cause damage to the appliance and danger to the user. When the activated charcoal filter is used, the extraction rate will be lower.

Caple CGC711BK - NOTE: - 1

text_image Technical diagram showing a thermal device with labeled components A and B, alongside its schematic view of internal components.

Caple CGC711BK - NOTE: - 2

natural_image Pure architectural floor plan lines without any text, numbers, or symbols

Caple CGC711BK - NOTE: - 3

natural_image Pure electrical circuit lines without any symbols

Caple CGC711BK - NOTE: - 4

OFF BUTTON

Switches the extraction fan off.

Caple CGC711BK - OFF BUTTON - 1

LOW SPEED BUTTON

Is suitable for simmering and cooking which does not produce much odour.

Caple CGC711BK - LOW SPEED BUTTON - 1

MEDIUM SPEED BUTTON

Airflow speed is ideal for extracting with standard cooking.

Caple CGC711BK - MEDIUM SPEED BUTTON - 1

HIGH SPEED BUTTON

When a high amount of smoke or odour is produced, press the high speed button for the most effective extraction.

Caple CGC711BK - HIGH SPEED BUTTON - 1

LIGHT BUTTON

Switches the light on and off.

CARE AND MAINTENANCE

IMPORTANT:

Before cleaning or maintenance please switch off the electricity supply and remove the plug from the wall.

REGULAR CLEANING

Use a soft damp cloth with lukewarm mildly soapy water or household cleaning detergent. Never use metal pads, chemicals, abrasive material, abrasive cleaning creams or stiff brushes to clean the appliance.

CLEANING THE GREASE FILTER

Clean the filter every month to help minimise the risk of fire. The filter collects grease, smoke and dust, therefore the filter is directly affecting the efficiency of the cooker hood. If not cleaned, the grease residue (which is potentially flammable) will saturate the filter. It can be easily cleaned with warm water and washing up liquid, alternatively the filters can be cleaned in your dishwasher. Please ensure no other items are washed with the filters, they must be washed separately to prevent food becoming trapped in the gauze. Cleaning the grease filters in the dishwasher may lead to discolouration, this is normal and is a not a fault with the product.

REPLACING YOUR CHARCOAL FILTER

This only applies if you are using the hood in recirculation mode (not vented to the outside). The charcoal filter traps your cooking odours and they need to be replaced, this can vary depending on how frequently the cooker hood is used. We recommend replacing them at least every 6 months.

This extractor uses CAP75CF charcoal filters.

Filters can be purchased directly from www.caple.co.uk.

REPLACING THE BULB

NOTE:

The lights must be replaced by a qualified person.

  1. Switch the unit off and unplug the appliance.
  2. Remove the 4 screws on the curved glass panel, and take off the glass carefully.
  3. Unplug the light from the connector and then push the light out of the hood.
  4. Replace with the same type and rated bulb/lamp fixing. LED lamp (max 2W).
  5. Connect the replacement light and screw the glass panel back on securely.

Caple CGC711BK - NOTE: - 1

natural_image Line drawing of a ceiling fan with two circular cutouts and a curved top (no text or symbols)

LIGHT SOURCE ENERGY CLASS

This product contains a light source of energy efficiency class G.

TROUBLESHOOTING

FAULT CAUSE SOLUTION
The lights on, but the fan does not workThe fan blade is jammed.Switch off the unit and contactCaple Service. To be repaired by qualified service personnel only.
The motor is damaged.
The lights and fan do not workA blown fuse. Replace the fuse.
The power cord is loose. Plug in to the power supply again.
Serious vibration of the unitThe fan blade is damaged.Switch off the unit and contactCaple Service. To be repaired by qualified service personnel only.
The fan motor is not fixed tightly.Switch off the unit and contactCaple Service. To be repaired by qualified service personnel only.
The unit is not hung correctly on the bracket.Take down the unit and check whether the bracket is in the correct location.
The extraction performance is not goodThe filter requires cleaning.Clean the grease filter as directed in the 'Care and maintenance' section. Replace the charcoal filter (if in recirculation mode).

If the above table has not solved the problem please contact Caple Service by phone on 0117 938 7420 or by email service@caple.co.uk

CGC911BK

CGC911SS

CGC711BK

CGC711SS

Caple CGC711BK - TROUBLESHOOTING - 1

text_image 259mm 266mm 560-1040mm 90mm 500mm 895mm

Caple CGC711BK - TROUBLESHOOTING - 2

text_image 259mm 266mm 550-1030mm 56mm 500mm 695mm

CGC611BK

CGC611SS

Caple CGC711BK - TROUBLESHOOTING - 3

text_image 259mm 266mm 533-1013mm 64mm 500mm 595mm

Caple CGC711BK - TROUBLESHOOTING - 4

caple

Caple Service

Fourth Way

T: 0117 938 1900

Avonmouth

E: service@caple.co.uk

Bristol

BS11 8DW

www.caple.co.uk

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Caple

Model : CGC711BK

Category : Range hood