SAMSUNG

AR09KSFSAWKNSA - Air-conditioner SAMSUNG - Free user manual and instructions

Find the device manual for free AR09KSFSAWKNSA SAMSUNG in PDF.

📄 63 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice SAMSUNG AR09KSFSAWKNSA - page 4
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Split Air Conditioner
Model AR09KSFSAWKNSA
Brand Samsung
Cooling Capacity (BTU/h) 9000
Cooling Capacity (kW) 2.5
Heating Capacity (BTU/h) 9500
Heating Capacity (kW) 2.8
Energy Efficiency (EER) 3.2
Refrigerant R32
Power Supply (V/Hz/Ph) 220-240 / 50 / 1
Indoor Unit Dimensions (WxDxH mm) 820 x 285 x 210
Outdoor Unit Dimensions (WxDxH mm) 720 x 548 x 310
Indoor Unit Weight (kg) 8.5
Outdoor Unit Weight (kg) 25.0
Noise Level Indoor (dB(A)) 19 - 39
Noise Level Outdoor (dB(A)) 48
Functions Cooling, Heating, Dehumidification, Fan, Auto, Sleep, Turbo
Filter Type Washable, Anti-Bacterial
Remote Control Included
Installation Type Wall-mounted
Warranty (years) 5 (compressor), 2 (parts)

Frequently Asked Questions - AR09KSFSAWKNSA SAMSUNG

How do I clean the filter on my Samsung AR09KSFSAWKNSA?
Turn off the unit and open the front panel. Remove the filter by sliding it out. Wash with warm water and mild detergent, let it dry completely, then reinstall. Clean every 2 weeks for optimal performance.
What is the recommended room size for this air conditioner?
The AR09KSFSAWKNSA is suitable for rooms up to 25 m² (269 sq ft) for effective cooling and heating.
Can I use the air conditioner without the remote?
Yes, there is a manual control button on the indoor unit. Press it to toggle between modes or use the 'Auto Clean' function.
How do I activate the Turbo mode?
Press the 'Turbo' button on the remote to enable fast cooling or heating. The unit will run at maximum capacity for 30 minutes.
What does the 'Auto Clean' function do?
After cooling or dehumidification, Auto Clean dries the indoor unit's heat exchanger to prevent mold and odor. It runs for about 30 minutes.
Why is my air conditioner not cooling properly?
Check the air filter for dirt, ensure the thermostat is set lower than room temperature, and verify that all doors/windows are closed. If issue persists, contact service.
How do I set the timer?
Press the 'Timer' button on the remote. Use + or - to set the desired time (0.5 to 12 hours). The unit will start or stop after the set time.
What type of refrigerant does this model use?
The AR09KSFSAWKNSA uses R32 refrigerant, which is more environmentally friendly and energy-efficient than older refrigerants.
Can I install the outdoor unit on a balcony?
Yes, but ensure proper ventilation and clearance as per the installation manual. The unit must be placed on a sturdy, level surface.
How often should I service the air conditioner?
Professional servicing is recommended annually. Regularly clean the filter and keep the outdoor unit free from debris.

User questions about AR09KSFSAWKNSA SAMSUNG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air-conditioner in PDF format for free! Find your manual AR09KSFSAWKNSA - SAMSUNG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AR09KSFSAWKNSA by SAMSUNG.

USER MANUAL AR09KSFSAWKNSA SAMSUNG

Features of your new air conditioner

2-step cooling

2-step cooling function will quickly cool the room to reach the desired temperature and then it will adjust the fan speed and air flow direction automatically to help you stay comfortable and refreshing.

Fast cooling/heating

If you want the strong and cool/warm air, just select Fast function! It will get you the strongest air!

Comfort cooling/heating

If you want the comfortable and refreshing air, Comfort function will spread the cool/warm air indirectly to you, so that you can stay comfortable.

Single User

Use Single User function when you are alone at home. Single User function will minimize the energy consumption with inverter technology and reduce your electricity bill by adjusting the maximum operating capacity of the compressor.

Easy Filter

There is no grille to remove before separating the filter from the air conditioner! Therefore, filter can be cleaned easily, more frequently! Frequent filter cleaning will prevent dust from entering into the product or accumulating on the filter.

good'sleep function

good'sleep function will allow you to have deep, good night's sleep by adjusting the temperature, fan speed and air flow direction.

Smart Install

When the installation is done, your product will examine itself through trial operation to check if it was installed properly.

Easy Installation

It's so easy to install! You can easily hang the product on the wall and connect the pipes and wires by opening the cover on the bottom of the product. Now you won't have to tilt the product to connect the pipe and the wires!

SAMSUNG AR09KSFSAWKNSA - Easy Installation - 1

Correct Disposal of This Product

(Waste Electrical & Electronic Equipment)

(Applicable in countries with separate collection systems)

This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal.

Contents

Preparation

Safety precautions 4

Checking before use 10

Basic function

Checking the name of the parts 11

Checking the remote controller 12

Basic function....14

Adjusting the air flow direction.... 17

Timer

Setting the Current time....18

Setting the On/Off timer 19

good'sleep mode....21

Options

Using the Fast function....22

Using the Comfort function 22

Using the Single User function 23

2-Step cooling function 24

Using the d'light Cool function 24

Using the Quiet function 25

Settings

Using the Auto clean function....26

Setting the Beep sound 26

Checking the power consumption....27

Setting the Display option....27

Resetting the Filter clean reminder 28

Using the Smart A/C application.... 28

Others

Cleaning the air conditioner....29

Maintaining the air conditioner....32

Troubleshooting 33

Installation

Safety precautions 35

Choosing the installation location 36

Accessories 40

Fixing the installation plate....41

Disassembling/Assembling the Cover panel for indoor unit installation 42

Connecting the assembly cable 44

Installing and connecting the assembly pipe of the indoor unit 47

Evacuating the indoor unit 48

Cutting or extending the pipe 48

Installing and connecting the drain hose of the indoor unit 50

Changing direction of the drain hose 51

Installing and connecting the drain hose of the outdoor unit 52

Evacuating the connected pipes....52

Performing the gas leak tests....55

Fixing the indoor unit in place 56

Fixing the outdoor unit in place 56

Smart Install mode....57

Final check and trial operation....59

Pump down procedure (when removing the product) 59

How to connect your extended power cables....60

Safety precautions

Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.

Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com.

Important safety symbols and precautions:

WARNINGHazards or unsafe practices that may result insevere personal injury or death.
CAUTIONHazards or unsafe practices that may result inminor personal injury or property damage.
Follow directions. Cut-off the power supply.
Do NOT attempt. Do NOT disassemble.
Make sure the machine is grounded to prevent electric shock.

FOR INSTALLATION

WARNING

Use the power line with the power specifications of the product or higher and use the power line for this appliance only. In addition, do not use an extension line.

▶ Extending the power line may result in electric shock or fire.
▶ Do not use an electric transformer. It may result in electric shock or fire.
▶ If the voltage/frequency/rated current condition is different, it may cause fire.

The installation of this appliance must be performed by a qualified technician or service company.

▶ Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury and may also void warranty on the installed product.

Install a Isolation Switch next to the Air Conditioner (but not on the panels of the Air Conditioner) and circuit breaker dedicated to the air conditioner.

▶ Failing to do so may result in electric shock or fire.

Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.

▶ Failing to do so may result in electric shock, fire, explosion, problems with the product.

Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak.

▶ This may result in electric shock or fire.

Never install the outdoor unit in a location such as on a high external wall where it could fall.

▶ If the outdoor unit falls, it may result in injury, death or property damage.

This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line.

▶ Failure to do so may result in electric shock, fire, and explosion.

▶ Make sure to use a socket-outlet with ground.

FOR INSTALLATION

CAUTION

Install your appliance on a level and hard floor that can support its weight.

▶ Failing to do so may result in abnormal vibrations, noise, or problems with the product.

Install the draining hose properly so that water is drained correctly.

▶ Failing to do so may result in water overflowing and property damage. Avoid adding drain to waste pipes as odours may arise in the future.

When installing the outdoor unit, make sure to connect the draining hose so that draining is performed correctly.

The water generated during the heating operation by the outdoor unit may overflow and result in property damage.

In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.

FOR POWER SUPPLY

WARNING

When the circuit breaker is damaged, contact your nearest service center.

Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert the power line between objects, or push the power line into the space behind the appliance.

▶ This may result in electric shock or fire.

Safety precautions

FOR POWER SUPPLY

SAMSUNG AR09KSFSAWKNSA - FOR POWER SUPPLY - 1

CAUTION

SAMSUNG AR09KSFSAWKNSA - CAUTION - 1

When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker.

▶ Failing to do so may result in electric shock or fire.

FOR USING

SAMSUNG AR09KSFSAWKNSA - FOR USING - 1

WARNING

SAMSUNG AR09KSFSAWKNSA - WARNING - 1

If the appliance is flooded, please contact your nearest service center.

▶ Failing to do so may result in electric shock or fire.

If the appliance generates a strange noise, a burning smell or smoke, cut-off the power supply immediately and contact the nearest service center.

▶ Failing to do so may result in electric shock or fire.

In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching the power line. Do not touch the appliance or power line.

▶ Do not use a ventilating fan.
▶ A spark may result in an explosion or fire.

To reinstall the air conditioner, please contact your nearest service center.

▶ Failing to do so may result in problems with the product, water leakage, electric shock, or fire.
▶ A delivery service for the product is not provided. If you reinstall the product in another location, additional construction expenses and an installation fee will be charged.
▶ Especially, when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air, please contact your nearest service center.
▶ Please refer to your warranty cards for terms and conditions.

SAMSUNG AR09KSFSAWKNSA - WARNING - 2

Do not touch the circuit breaker with wet hands.

▶ This may result in electric shock.

Do not turn the air conditioner off with the circuit breaker while it is operating.

▶ Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric shock or fire.

After unpacking the air conditioner, keep all packaging materials well out of the reach of children, as packaging materials can be dangerous to children.

▶ If a child places a bag over its head, it may result in suffocation.

SAMSUNG AR09KSFSAWKNSA - WARNING - 3

Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating.

▶ Take special care that children do not injure themselves by inserting their fingers into the product.

Do not touch the air flow blade with your hands or fingers during the heating operation.

▶ This may result in electric shock or burns.

Do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner.

▶ Take special care that children do not injure themselves by inserting their fingers into the product.

Do not strike or pull the air conditioner with excessive force.

This may result in fire, injury, or problems with the product.

FOR USING

SAMSUNG AR09KSFSAWKNSA - FOR USING - 1

WARNING

SAMSUNG AR09KSFSAWKNSA - WARNING - 1

Do not place an object near the outdoor unit that allows children to climb onto the machine.

This may result in children seriously injuring themselves.

Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people.

▶ Since this may be dangerous due to a lack of oxygen, Open a window at least once an hour.

SAMSUNG AR09KSFSAWKNSA - WARNING - 2

If any foreign substance such as water has entered the appliance, cut-off the power supply and contact the nearest service center.

▶ Failing to do so may result in electric shock or fire.

SAMSUNG AR09KSFSAWKNSA - WARNING - 3

Do not attempt to repair, disassemble, or modify the appliance yourself.

▶ Do not use any fuse (such as cooper, steel wire, etc.) other than the standard fuse.

▶ Failing to do so may result in electric shock, fire, problems with the product, or injury.

Do not place objects or devices under the indoor unit.

▶ Water dripping from the indoor unit may result in fire or property damage. (example electrical appliances)

Check that the installation frame of the outdoor unit is not broken at least once a year.

▶ Failing to do so may result in injury, death or property damage.

Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.

Do not stand on top of the appliance or place objects (such as laundry, lighted candles, lighted cigarettes, dishes, chemicals, metal objects, etc.) on the appliance.

This may result in electric shock, fire, problems with the product, or injury.

Do not operate the appliance with wet hands.

▶ This may result in electric shock.

Do not spray volatile material such as insecticide onto the surface of the appliance.

As well as being harmful to humans, it may also result in electric shock, fire or problems with the product.

Do not drink the water from the air conditioner.

▶ The water may be harmful to humans.

Do not apply a strong impact to the remote controller and do not disassemble the remote controller.

Do not touch the pipes connected with the product.

This may result in burns or injury.

Do not use this air conditioner to preserve precision equipment, food, animals, plants or cosmetics, or for any other unusual purposes.

This may result in property damage.
▶ Please refer to your warranty cards for terms and conditions.

Avoid directly exposing humans, animals or plants from the air flow from the air conditioner for long periods of time.

This may result in harm to humans, animals or plants.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

For use in Europe : This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

FOR CLEANING

WARNING

Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or alcohol to clean the appliance.

This may result in discoloration, deformation, damage, electric shock or fire. Before cleaning or performing maintenance, cut-off the power supply and wait until the fan stops.

▶ Failing to do so may result in electric shock or fire.

FOR CLEANING

CAUTION

Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges.

This should be done by a qualified technician please contact your installer or service center.

Do not clean the inside of the air conditioner by yourself.

For cleaning inside the appliance, contact your nearest service center.
When cleaning the internal filter, refer to the descriptions in the 'Cleaning the air conditioner' section.
▶ Failure to do may result in damage, electric shock or fire.

Checking before use

Operation ranges

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

Mode Indoor temperature Outdoor temperature Indoor humidity
Cooling16 °C~32 °C -10 °C~46 °C Relative humidity 80% or less
Heating27 °C or less -15 °C~24 °C -
Dry18 °C~32 °C -10 °C~46 °C -

▶ If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
If the outdoor temperature goes down to -5^ , heating capacity may decrease as much as 60% 70% of specified capacity according to the using conditions.

Maintaining your air conditioner

Internal protections via the unit control system

This internal protection operates if an internal fault occurs in the air conditioner.

Type Description
Against cold airThe internal fan will be off to prevent cold air when the heat pump is heating.
Defrost cycleThe internal fan will be off to defrost ice when the heat pump is heating.Vertical air flow blade will be closed during defrost cycle and it will open again during heating operation after defrost cycle.
Protect compressorThe air conditioner does not start operating immediately to help protect the compressor of the outdoor unit after it has been started.

SAMSUNG AR09KSFSAWKNSA - Maintaining your air conditioner - 1

- If the heat pump is operating in Heat mode, defrost cycle is actuated to help remove frost from an outdoor unit that may have deposited at low temperatures. The internal fan is switched off automatically and restarted only after the defrost cycle is completed.

SAMSUNG AR09KSFSAWKNSA - Maintaining your air conditioner - 2

- A Samsung-branded air conditioning unit installed in an area which is not easily accessible (including without limitation roofs or positions above 2.4 metres for the outdoor unit) may require additional costs for labour and access equipment as may be mandated by occupational health and safety requirements. Such costs are to be borne by you should service or maintenance (including service or maintenance covered by your warranty or by a consumer guarantee) be required.

Smart install

▶ Through Smart install function, installer can check if the installation was done properly.
▶ If the installation was not done properly, error indicator will turn on the indoor unit display. Therefore user will know if the installation was done properly or not.

Checking the name of the parts

Your air conditioner may slightly look different from illustration shown below depending on your model.

Main parts
SAMSUNG AR09KSFSAWKNSA - Checking the name of the parts - 1

text_image Air filter Air intake Room temperature sensor Wi-Fi module (AR**KSWS** Series) Air flow blade (up and down) Air flow blade (left and right)

Display
SAMSUNG AR09KSFSAWKNSA - Checking the name of the parts - 2

text_image Power button/ Remote controller receiver AR**KSWS***Series 8.8 Wi-Fi indicator Timer/ Auto clean indicator Timer/ Auto clean Temperature indicator / Filter Reset indicator(0F) Defrost indicator(0F) Power consumption indicator / Auto clean indicator(0C) / DRED(Demand Response Enabling Devices) indicator(0,1)d2 d3 AR**KSFS*** Series 8.8 Single User indicator indicator

Checking the remote controller

  • Point the remote controller towards the remote controller receiver of the indoor unit.
  • When you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( )appears on the remote controller display.

Remote controller buttons

* Before using the functions of the remote controller, you should set the current time. (Refer to page 17)

SAMSUNG AR09KSFSAWKNSA - Remote controller buttons - 1

text_image Power Turn on/off the air conditioner Temp + - Increase/Decrease the temperature by 1 °C. Options Select options during operation Timer Select Timer option Directional < > Move through the Timer, Options or Settings menu to make a selection Mode + Temp - Fan Fan^~ Adjust the fan speed Horizontal air swing Activate/Deactivate horizontal air flow blades movement automatically Settings Select settings SET Set/Cancel the selected option or setting Vertical air swing Activate/Deactivate vertical air flow blade movement automatically Mode Set one of the 5 operating modes

SAMSUNG AR09KSFSAWKNSA - Remote controller buttons - 2

- In case you wish to cancel the options or settings that you have just set, press the Options or Settings button again, then the most recently selected item will blink and you may simply cancel it by pressing the SET button while selected item is blinking.

Remote controller display

SAMSUNG AR09KSFSAWKNSA - Remote controller display - 1

text_image Set temperature/ Time (for Timer option) indicator Set 88°C On Off Transmit indicator low battery indicator good'sleep indicator 10:00 AM PMhr Fan speed indicator Auto Cool Dry Fan Heat Vertical/Horizontal air swing indicator 2-Step Fast Comfort Single user Quiet d'light Cool Options indicator Usage Clean Beep Filter Reset Display Clock Settings indicator

SAMSUNG AR09KSFSAWKNSA - Remote controller display - 2

• Make sure that the water does not get to the remote controller.
• The following function are displayed on the remote controller display but not supported in this model.
- Virus Doctor ( )
- When turning off and turning on the remote controller, the Timer, Options and Settings set before turning off the remote controller are cancelled. However, the fan direction does not change.

Low Battery warning

When the battery is exhausted, (4) will be displayed in the remote controller display. When the icon appears, change the batteries. The remote controller requires two 1.5 V AAA type batteries.

Storing the remote controller

When you do not use the remote controller for long time, remove the batteries from the remote controller and store it.

Inserting the batteries

  1. Push the lever as arrow indicates on the rear side of the remote controller and pull up.
  2. Insert two AAA batteries.
    Check and match the "+" and "-" signs accordingly. Make sure you have inserted the batteries in correct position.
  3. Close the cover by place it back to its original position.
    You should hear click sound when the cover is locked properly.

SAMSUNG AR09KSFSAWKNSA - Inserting the batteries - 1

text_image Diagram of a battery internal structure with numbered components and labeled parts

SAMSUNG AR09KSFSAWKNSA - Inserting the batteries - 2

  • The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps are in the same space.
    • If other electrical products operate by the remote controller, call your nearest contact center.

SAMSUNG AR09KSFSAWKNSA - Inserting the batteries - 3

Correct disposal of batteries in this product

(Applicable in countries with separate collection systems)

This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66.

If batteries are not properly disposed of, these substances can cause harm to human health or the environment.

To protect natural resources and to promote material reuse, please separate batteries from other types of waste and recycle them through your local, free battery return system.

Basic function

Basic operation is an operation mode that can be selected by pressing the Mode button.

Auto(2-Step Cooling or Heat)

In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature.

- 2-Step Cooling mode sets the air conditioner to operate in Fast + Cool mode when set temperature is lower than indoor temperature, and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature.

Cool

In Cool mode, the air conditioner will cool your room. You can adjust the temperature and the fan speed to feel cooler in hot season.

  • If current outside temperature is much higher than the selected indoor temperature, it may take time to bring the inner temperature to the desired coolness.
  • Quiet mode makes the noise quieter during the operation of the indoor unit in the Cool mode.

Dry

The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air.

Dry mode makes the air feel refreshing in a humid climate.

To activate the Dry mode, set temperature on the remote controller should be lower than indoor room temperature.

Fan

Fan mode can be selected to circulate your room. Fan mode will be helpful to refresh the stale air in your room.

Heat

The air conditioner heats as well as cools. Warm your room with this versatile appliance in the cold of winter.

  • Fan may not operate for about 3\~5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up.
  • Quiet mode makes the noise quieter during the operation of the indoor unit in the Heat mode.
  • Since the air conditioner heats the room by taking heat energy from outdoor air, the heating capacity may decrease when outdoor temperature is extremely low.

Use an additional heating appliance in combination with the air conditioner if you feel the air conditioner heats insufficiently.

DEMAND RESPONSE MODE (DRM 1, 2, 3)

This air conditioner is equipped with a Demand Response unit which will respond to a signal sent by the power supply utility during emergency conditions.

  • During a Demand Response Event, the indoor and outdoor unit will be operated according to DRM mode (DRM 1, 2, 3) and indoor unit will show "d 1,d2 d3" on the display.
    • In case customer has set swing mode prior to DRM 1, 2, 3 being initiated, Air flow blades will continue to swing.

AR**KSWS**** Series
SAMSUNG AR09KSFSAWKNSA - DEMAND RESPONSE MODE (DRM 1, 2, 3) - 1

text_image d1

SAMSUNG AR09KSFSAWKNSA - DEMAND RESPONSE MODE (DRM 1, 2, 3) - 2

text_image d2

SAMSUNG AR09KSFSAWKNSA - DEMAND RESPONSE MODE (DRM 1, 2, 3) - 3

text_image 83

AR**KSFS*** Series
SAMSUNG AR09KSFSAWKNSA - DEMAND RESPONSE MODE (DRM 1, 2, 3) - 4

SAMSUNG AR09KSFSAWKNSA - DEMAND RESPONSE MODE (DRM 1, 2, 3) - 5

SAMSUNG AR09KSFSAWKNSA - DEMAND RESPONSE MODE (DRM 1, 2, 3) - 6

AIR CONDITIONER DEMAND RESPONSE MODES

Operational instruction (OI)Demand response mode (DRM)*Description of operation in this modeMandatory for compliance with this Standard (AS/NZS 4755.3.1)
OI 1 DRM1 Indoor fan and Compressor off Yes
OI 2 DRM2 The air conditioner continues to cool or heat during the demand response event, but the electrical energy consumed by the air conditioner in a half hour period is not more than 50 % of the total electrical energy that would be consumed if operating at the rated capacity in a half hour period.No
OI 3 DRM3 The air conditioner continues to cool or heat during the demand response event, but the electrical energy consumed by the air conditioner in a half hour period is not more than 75 % of the total electrical energy that would be consumed if operating at the rated capacity in a half hour period.No

Basic function

Press the button to turn on the air conditioner.

Press the button to set the operating mode.

• Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat.

SAMSUNG AR09KSFSAWKNSA - Basic function - 1

flowchart
graph LR
    A["Set 24°C\n1:30AM\nAuto"] --> B["Set 24°C\n1:30AM\nCool"]
    B --> C["Set 24°C\n1:30AM\nDry"]
    C --> D["Set 24°C\n1:30AM\nFan"]
    D --> E["Set 24°C\n1:30AM\nHeat"]

Press the button to adjust the temperature.

Auto You can adjust the set temperature by 1 °C within the range of 16 °C\~30 °C.

Cool You can adjust the set temperature by 1 °C within the range of 16 °C\~30 °C.

Dry You can adjust the set temperature by 1 °C within the range of 18 °C\~30 °C.

Fan Temperature adjustment is not possible.

Heat You can adjust the set temperature by 1 °C within the range of 16 °C\~30 °C.

Press the button to set the desired fan speed.

Auto(Auto)
Cool(Auto), (Low), (Med), (High), (Turbo)
Dry(Auto)
Fan(Med), (High), (Turbo)
Heat(Auto), (Low), (Med), (High), (Turbo)

SAMSUNG AR09KSFSAWKNSA - Basic function - 2

• Dry mode is only available in the cooling mode.

Adjusting the air flow direction

This function will allow you to adjust the air flow direction vertically and/or horizontally.

Press the or button to make air flow blades vertically and/or horizontally.

Vertical air flow Horizontal air flow

SAMSUNG AR09KSFSAWKNSA - Adjusting the air flow direction - 1

text_image Mode Temp Fan Timer Options Settings

SAMSUNG AR09KSFSAWKNSA - Adjusting the air flow direction - 2

text_image Mode Temp Fan Timer Options Settings

To keep the air flow direction in a constant direction, press the or button again. The air flow blade(s) will stop the movement.
▶ If you adjust the vertical air flow blade manually, it may not close completely when you turn off the air conditioner.
▶ If you adjust the horizontal air flow blade manually, it may not operate normally.

SAMSUNG AR09KSFSAWKNSA - Adjusting the air flow direction - 3

text_image Set 24°C 11:30AM Auto 2-Step Fast Comfort Single your Quiet Light Cool Usage Clean Beep Filter Reset Display Clock

SAMSUNG AR09KSFSAWKNSA - Adjusting the air flow direction - 4

text_image Set 24°C 11:30 AM Auto 2-Step Fast Comfort Single user Quiet in light Cool Usage Clean Beep Filter Reset Display Clock

SAMSUNG AR09KSFSAWKNSA - Adjusting the air flow direction - 5

  • Adjusting the air flow direction is not available in good'sleep mode while it is in cool mode.
    • However, you can adjust the air flow direction in good'sleep mode while it is in heat mode.

Remote controller display Remote controller display

Setting the Current time

Before using the functions of the air-conditioner, set the current time.

SAMSUNG AR09KSFSAWKNSA - Setting the Current time - 1

text_image Timer Options Settings < SET > 1:30AM Clean Beep Filter Reset Display Clock

Remote controller display

  1. Press the Settings button.

  2. Press the <, > or Settings button until (Clock) indicator starts to blink.

  3. Press the SET button to set the Clock function.

- (Clock)→(Clock) indicator will be displayed on the remote controller display and you can set the time.

  1. Press the button to set the time.

- You can set the time in hourly units from 1 hour \~ 12 hours according to AM, PM and in minute units from 0 \~ 59 minutes.

  1. Press the SET button to complete the current time setting.

- Current time setting will be cancelled if you don't press the SET button within 10 seconds after setting the time. Therefore, check for the current time on the remote controller display.

Setting the On/Off timer

SAMSUNG AR09KSFSAWKNSA - Setting the On/Off timer - 1

Check the current time on the remote controller before using this function.
The default time is 1 AM on the remote controller. The current time is reset to default time after changing the batteries.

You can set the air conditioner to turn on/off automatically at desired time.

Setting On timer while the air conditioner is off / Off timer while the air conditioner is on

SAMSUNG AR09KSFSAWKNSA - Setting On timer while the air conditioner is off / Off timer while the air conditioner is on - 1

text_image Timer Options Settings < SET >

Setting On timer

SAMSUNG AR09KSFSAWKNSA - Setting On timer while the air conditioner is off / Off timer while the air conditioner is on - 2

text_image On 8.8°C Off 1:30 AM Auto Cool Dry Fan Heat 2 Step Fast Comfort Single User Quiet Night Cool Usage Clean Beep Filter Reset Display Clock

Remote controller display

Setting Off timer
SAMSUNG AR09KSFSAWKNSA - Setting On timer while the air conditioner is off / Off timer while the air conditioner is on - 3

text_image Set 24°C off 24 11:30 AM Auto 2-Step Fast Comfort Single user Quiet diligent Cool Usage Clean Beep Filter Reset Display Clock

Remote controller display

  1. Press the Timer button to select (On/Off).

- (On/Off) indicator will keep blinking and you can set the time.

  1. Press the button to set the time.

- You can set the time in hourly units from 1 hour \~ 12 hours according to AM, PM and in minute units from 0 \~ 59 minutes.

  1. Press the SET button to complete the On/off timer setting.

- (On/Off) indicator and the set time of the timer will be displayed on the remote controller display and the Timer indicator ⏻) will be displayed on the indoor unit display.

- On/Off timer setting will be cancelled if you don't press the SET button within 10 seconds after setting the time. Therefore, check for the (On/Off) indicator on the remote controller display and the Timer indicator (💡) on the indoor unit display.

▶ Press the Timer button → select (On/Off) → press the ☑ or ▶ button Cancel → set the timer to - - → press the SET button.
▶ Press the Power (💡) button.

SAMSUNG AR09KSFSAWKNSA - Setting On timer while the air conditioner is off / Off timer while the air conditioner is on - 4

  • When On/Off timer setting is completed, the set status will be displayed for 3 seconds, and then only (On/Off) indicator will remain on the remote controller display thereafter.
  • If you press the Power ⏻ button on the indoor unit after setting the On/Off timer from the remote controller, Timer indicator on the indoor unit display will disappear and the On/Off timer will be cancelled. Even though the On/Off timer is cancelled, (On/Off) indicator on the remote controller will remain displayed.
  • When the On timer is set while the air conditioner is off, Timer indicator (💡) will be displayed and remain on until the On timer turns on.
  • Off timer may not work depending on the On/Off status of the indoor unit and the On/Off status of the indicator on the remote controller display.
  • Only the latest setting timer will be applied between the On Timer/Off Timer and good'sleep Off timer functions.

Setting the On/Off timer

Additional options available in On/Off timer mode (When the remote controller is on)
SAMSUNG AR09KSFSAWKNSA - Setting the On/Off timer - 1You can select from Auto/Cool/Dry/Fan /Heat.
SAMSUNG AR09KSFSAWKNSA - Setting the On/Off timer - 2You can set the temperature after selecting the operation mode.Temperature adjustment is available when Auto/Cool/Dry /Heat mode is selected.

Setting on timer and off timer simultaneously

SAMSUNG AR09KSFSAWKNSA - Setting on timer and off timer simultaneously - 1

text_image On 8.0°C Off 11:30 AM Auto Cool Dry Fan Heat - 2-Step Fast Comfort Single user Quiet d Light Cool Usage Clean Beep Filter Reset Display Clock

Remote controller display

Follow the same process for setting on timer and off timer.

good'sleep mode

For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep ▷ Sound sleep ▷ Wake up stage. When the air conditioner is operating in Cool/Heat mode;

SAMSUNG AR09KSFSAWKNSA - good'sleep mode - 1

text_image Timer Options Settings < SET >

SAMSUNG AR09KSFSAWKNSA - good'sleep mode - 2

text_image Set 26°C Off 20 1:30AM Cool Auto Fan Heat 2-Step Fast Comfort Single user Quiet Light Cool Usage Clean Beep Filter Reset Display Clock

Remote controller display

  1. Press the Timer button to select (💡).

- (a) Indicator will keep blinking and you can set the time.

  1. Press the button to set the time.

- You can set the time in half hour unit from 30 minutes (0.5 on the display) \~ 3 hours and hour unit from 3\~12 hours.

- Time can be set from minimum 30 minutes to maximum 12 hours.

- Default time setting for the model is 8 hours.

  1. Press the SET button to complete the good'sleep mode setting.

- Indicator and the set time of the model will be displayed on the remote controller display.

- Timer indicator ⏻) will be displayed on the indoor unit display.

- good'sleep mode setting will be cancelled if you don't press the SET button within 10 seconds after setting the time. Therefore, check for the 📋 Indicator on the remote controller display and the Timer indicator 🌐 on the indoor unit display.

Cancel ▶ Press the Timer button → select (✗) → press the (< or >) button → set the timer to -.→ press the SET button.

Additional options available in good'sleep mode
SAMSUNG AR09KSFSAWKNSA - good'sleep mode - 3You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.
SAMSUNG AR09KSFSAWKNSA - good'sleep mode - 4When the good'sleep mode is on.In Cool mode : Air flow direction will be adjusted automatically.In Heat mode : Adjusting air flow direction is available.

Temperature and fan speed change ingood'sleep mode

• Fall asleep: Eases you into sleep by dropping the temperature.
• Sound sleep: Relaxes your body and raises your temperature slightly.
- Wake up: Allows you to wake up from comfortable intermittent air and it makes you feel refreshed.

SAMSUNG AR09KSFSAWKNSA - Temperature and fan speed change ingood'sleep mode - 1

  • Fan speed and the air flow direction will be adjusted automatically in good'sleep mode.
  • Recommended set temperature is between 25^ 27^ for cooling and 21^ 23^ for heating.
  • If the set temperature is too low, you may feel cold during sleep or catch a cold.
  • Optimal operation hour of good'sleep mode is 8 hours. Therefore, if the time is set too short or long, you may not feel as comfortable as you would expect.
  • If the good'sleep mode is set over 5 hours, Wake up stage will begin when 1 hour is remaining in the operation time and the air conditioner will stop automatically.
  • When the On timer and the good'sleep function is set simultaneously, the air conditioner will only apply the function that was set later.

Using the Fast function

You can set the Fast function to provide fast and powerful cooling/heating.

When the air conditioner is operating in Cool/Heat mode;

SAMSUNG AR09KSFSAWKNSA - Using the Fast function - 1

text_image Timer Options Settings < SET >
  1. Press the Options button.
  2. Press the <, > or Options button until (Fast) indicator starts to blink.
  3. Press the SET button to set the Fast function.
  4. (Fast)→(Fast) indicator will be displayed on the remote controller display and Fast function will begin.

Cancel

▶ Press the Options button → Press the◀, ▶ or Options button to make the (Fast) indicator blink and press the SET button.

SAMSUNG AR09KSFSAWKNSA - Cancel - 1

text_image 8:00 11:30 AM Cool Fast

SAMSUNG AR09KSFSAWKNSA - Cancel - 2

• Fast function is only available in Cool/Heat mode.
• Vertical/Horizontal air swing can be adjusted.
- Set temperature and fan speed cannot be adjusted.
- If the Fast function is selected while 2-Step Cooling/Comfort/Single user/ Quiet/good'sleep function is on, corresponding function will be cancelled.
- When you select Fast function in Heat mode, you may not be able to increase fan speed in order to prevent any cool air from blowing.

Remote controller display

Using the Comfort function

You can set the Comfort function to provide mild cooling/heating.

When the air conditioner is operating in Cool/Heat mode;

SAMSUNG AR09KSFSAWKNSA - Using the Comfort function - 1

text_image Temp — 小 ✓ Timer Options Settings << SET >
  1. Press the Options button.
  2. Press the ◀, ▶ or Options button until (Comfort) indicator starts to blink.
  3. Press the SET button to set the Comfort function.
  4. (Comfort)→(Comfort) indicator will be displayed on the remote controller display and Comfort function will begin.

Cancel

▶ Press the Options button →Press the ◀, ▶ or Options button to make the (Comfort) indicator blink and press the SET button.

SAMSUNG AR09KSFSAWKNSA - Cancel - 1

text_image Set 24°C 17:30AM Cool Comfort

SAMSUNG AR09KSFSAWKNSA - Cancel - 2

• Comfort function is only available in Cool/Heat mode.
• Vertical/Horizontal air swing can be adjusted.
- Set temperature can be adjusted, but fan speed cannot be adjusted.
- If the Comfort function is selected while Step Cooling/ Fast/Single user/Quiet/goodtisle is on, corresponding function will be cancelled.

Remote controller display

Using the Single User function

This function will reduce the energy usage while the air conditioner is operating in Cool/Heat mode.

When the air conditioner is operating in Cool/Heat mode;

SAMSUNG AR09KSFSAWKNSA - When the air conditioner is operating in Cool/Heat mode; - 1

text_image Timer Options Settings < SET >

SAMSUNG AR09KSFSAWKNSA - When the air conditioner is operating in Cool/Heat mode; - 2

text_image Set 24°C 11:30AM Cool Single user
  1. Press the Options button.
  2. Press the ◀, ▶ or Options button until (Single user) indicator starts to blink.
  3. Press the SET button to set the Single user function.
  4. (Single user)→ (Single user) indicator will be displayed on the remote controller display. Then = = = =_ will be displayed on the set temperature indicator part for few seconds and Single user function will begin.
  5. When the Single user function is on, vertical air swing will turn on automatically.

  6. If the current set temperature is lower than 24^ C in Cool mode, it will be automatically raised to 24^ C.

Cancel

▶ Press the Options button → Press the (<, >) or Options button to make the (Single user) indicator blink and press the SET button.

SAMSUNG AR09KSFSAWKNSA - Cancel - 1

• Single user function is only available in Cool/Heat mode.
- If the Single user function is selected while 2-Step Cooling/Fast/Comfort / Quiet/guest is open, corresponding function will be cancelled.
- Vertical air swing will remain on even after the Single user function is cancelled.

Remote controller display

Additional options available in Single user function
You can adjust the set temperature by 1 °C within the range of 24 °C ~ 30 °C in Cool mode and 16 °C ~ 30 °C in Heat mode.
(Auto), (low), (Med), (High) (Turbo) can be selected.
Vertical/Horizontal air swing can be selected.

2-Step cooling function

2-Step Cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor temperature is higher than the set temperature, and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature.

When the air conditioner is operating in Cool mode;

SAMSUNG AR09KSFSAWKNSA - When the air conditioner is operating in Cool mode; - 1

text_image Timer Options Settings < SET >
  1. Press the Options button.
  2. Press the ◀, ▶ or Options button until (2-Step) indicator starts to blink.
  3. Press the SET button to set the 2-Step Cooling function.

- (2-Step)→(2-Step) indicator will be displayed on the remote controller display and 2-Step Cooling function will begin.

Cancel

▶ Press the Options button → Press the (<, >) or Options button to make the (2-Step) indicator blink and press the SET button.

SAMSUNG AR09KSFSAWKNSA - When the air conditioner is operating in Cool mode; - 2

text_image Set 18°C 14:30AM Cool 2-Step Fast Comfort Single user Quiet Light Cool Usage Clean Beep Filter Reset Display Clock

Remote controller display

Using the d'light Cool function

This function will let the air conditioner select the operation mode automatically from Cool/Dry/Fan mode to provide refreshing air. When the function is selected, air conditioner will operate in Cool mode for 10 minutes and change to appropriate operation mode according to surrounding environment.

Press the d'light Cool button on the remote controller while the air conditioner is operating in Cool mode;

SAMSUNG AR09KSFSAWKNSA - Press the d'light Cool button on the remote controller while the air conditioner is operating in Cool mode; - 1

text_image Options Timer Settings < SET >
  1. Press the Options button.
  2. Press the ◀, ▶ or Options button until (d'light Cool) indicator starts to blink.
  3. Press the SET button to set the d'light Cool function.

- (d'light Cool)→(d'light Cool) indicator and air swing (⇌) indicator will be displayed on the remote controller display and d'light Cool function will begin.

- The air conditioner will set the temperature to auto and adjust the fan speed automatically according to the room temperature.

Cancel

▶ Press the Options button → Press the ⬇, ▶ or Options button to make the (d'light Cool) indicator blink and press the SET button.

SAMSUNG AR09KSFSAWKNSA - Press the d'light Cool button on the remote controller while the air conditioner is operating in Cool mode; - 2

text_image 80 1:30 AM Cool d'light Cool

SAMSUNG AR09KSFSAWKNSA - Press the d'light Cool button on the remote controller while the air conditioner is operating in Cool mode; - 3

• d'light Cool function is only available in Cool mode.
- When d'light Cool function is activated, temperature sets automatically and R_U will appear on the remote controller display.
- If you press the Mode button while the d'light Cool function is on, it will cancel the function.

Using the Quiet function

You can reduce the noise generated from an indoor unit during Cool/Heat mode.

When the air conditioner is operating in Cool/Heat mode;

SAMSUNG AR09KSFSAWKNSA - Using the Quiet function - 1

text_image User interface control panel with 'Options' button and navigation buttons including Timer, Save, and SET buttons

SAMSUNG AR09KSFSAWKNSA - Using the Quiet function - 2

text_image Set 18°C OFF 19:30 AM Cool Auto Fan Heat 2-Step Fast Comfort Single User Light Cool Usage Clean Beep Filter Reset Display Clock Quiet

Remote controller display

  1. Press the Options button.
  2. Press the ◀, ▶ or Options button until (Quiet) indicator starts to blink.
  3. Press the SET button to set the Quiet function.
  4. (Quiet)→(Quiet) indicator will be displayed on the remote controller display and Quiet function will begin.

Cancel

▶ Press the Options button → Press the (<, >) or Options button to make the (Quiet) indicator blink and press the SET button.

Additional options available in Quiet function
SAMSUNG AR09KSFSAWKNSA - Using the Quiet function - 3You can adjust the set temperature by 1 °C within the range of 16 °C ~ 30 °C.
SAMSUNG AR09KSFSAWKNSA - Using the Quiet function - 4Fan speed is set to (Auto).
SAMSUNG AR09KSFSAWKNSA - Using the Quiet function - 5Vertical/Horizontal air swing can be selected.

SAMSUNG AR09KSFSAWKNSA - Using the Quiet function - 6

  • Quiet function is only available in Cool/Heat mode.
  • If the Quiet function is selected while 2-Step Cooling/Fast/Comfort/Single user/gundtisle is on, corresponding function will be cancelled.

Using the Auto clean function

Auto clean function will minimise the moisture inside of the indoor unit. Activate this function to help provide you with clean air.

When the air conditioner is operating;

SAMSUNG AR09KSFSAWKNSA - Using the Auto clean function - 1

text_image Timer Options Settings << SET >

AR**KSWS*** Series

SAMSUNG AR09KSFSAWKNSA - Using the Auto clean function - 2

text_image C1

AR**KSFS*** Series

SAMSUNG AR09KSFSAWKNSA - Using the Auto clean function - 3

text_image 0:1

Indoor unit display

  1. Press the Settings button.

  2. Press the ◀, ▶ or Settings button until (Clean) indicator starts to blink.

  3. Press the SET button to set the Auto clean function.

- 3 seconds after setting Auto clean function, (Clean) indicator on the remote controller display will disappear and Auto clean (☐), Timer (☑) indicator will turn on the indoor unit display. Auto clean function will be activated after the air conditioner stops operating. - Duration of the Auto clean function can be different depending on the previous operation mode used.

Auto(cool), Cool, Dry mode: 30 minutes.

Auto(heat), Heat, Fan mode: 15 minutes.

Cancel

▶ Press the Settings button → Press the ☑, ☒ or Settings button to make the (Clean) indicator blink and press the SET button.

SAMSUNG AR09KSFSAWKNSA - Cancel - 1

- When the operation mode is set during Auto clean function is activated, the air conditioner will operate in chosen operation mode and the Auto clean function will be re-activated when the operation stops. - During the auto clean function, indoor fan will continue to run and air flow blade will remain open to expel ambient air.

Setting the Beep sound

Beep sound from the indoor unit can be muted.

SAMSUNG AR09KSFSAWKNSA - Setting the Beep sound - 1

text_image Timer Options Settings < SET >
  1. Press the Settings button.

  2. Press the◀,▶ or Settings button until (Beep) indicator starts to blink.

  3. Press the SET button to mute the beep sound.

- 3 seconds after setting Beep sound function, (Beep) indicator on the remote controller display will disappear and Beep sound function will begin.

Checking the power consumption

This function is displayed on the indoor unit display but not supported in **30** model.

This function will display the amount of electricity consumed by operating the air conditioner.

When the air conditioner is operating;

SAMSUNG AR09KSFSAWKNSA - Checking the power consumption - 1

text_image Timer Options Settings < SET >

AR**KSWS*** Series
SAMSUNG AR09KSFSAWKNSA - Checking the power consumption - 2

text_image 0:1

AR**KSFS*** Series
SAMSUNG AR09KSFSAWKNSA - Checking the power consumption - 3

text_image 0:1

Indoor unit display

  1. Press the Settings button.
  2. Press the ◀, ▶ or Settings button until (Usage) indicator starts to blink.
  3. Press the SET button to check the power consumption.

  4. 3 seconds after setting power consumption checking function, (Usage) indicator on the remote controller will disappear.

  5. Indoor unit will display the amount of Power consumption for few seconds and then return to usual status by displaying the set indoor temperature.
  6. Power consumption will be calculated from the moment the air conditioner is turned on and calculated value will be reset when the air conditioner turns off.
  7. 0.1 is the default value of the electricity consumption and 99 is the maximum value. Unit is in kWh.

SAMSUNG AR09KSFSAWKNSA - Checking the power consumption - 4

- When the air conditioner is not operating, power consumption will not be displayed on the indoor unit display.

Setting the Display option

Display lighting can be adjusted by following this instruction.

SAMSUNG AR09KSFSAWKNSA - Setting the Display option - 1

text_image Timer Options Settings < SET >
  1. Press the Settings button.
  2. Press the ◀, ▶ or Settings button until (Display) indicator starts to blink.
  3. Press the SET button to set the display status.

- 3 seconds after setting Display function, (Display) indicator on the remote controller display will disappear and indoor unit display will be turned off.

Cancel

▶ Press the Settings button → Press the ⏻, ⏻ or Settings button to make (Display) indicator blink and press the SET button.

▶ (Display) indicator on the remote controller display will disappear and the indoor unit display will be turned on again.

SAMSUNG AR09KSFSAWKNSA - Cancel - 1

• Display option cannot be set when the air conditioner is off.
• Operation or timer display will not be turned off by the display off function.

Resetting the Filter clean reminder

When Filter clean reminder (Rights up on the indoor unit display, clean the filter and reset the reminder by following this instruction.

SAMSUNG AR09KSFSAWKNSA - Resetting the Filter clean reminder - 1

text_image Timer Options Settings < SET >

AR**KSWS**** Series

SAMSUNG AR09KSFSAWKNSA - Resetting the Filter clean reminder - 2

text_image CF

AR**KSFS*** Series

SAMSUNG AR09KSFSAWKNSA - Resetting the Filter clean reminder - 3

text_image CF

Indoor unit display

  1. Press the Settings button.

  2. Press the ◀, ▶ or Settings button until (Filter Reset) indicator starts to blink.

  3. Press the SET button to reset Filter clean reminder.

- 3 seconds after setting Filter clean reminder function, (Filter Reset) indicator on the remote controller display will disappear and QIndicator on the indoor unit display will disappear.

Using the Smart A/C application

You can conveniently control your air conditioner anywhere with Smart APP. (Applicable model: AR**KSWS***Series)

WIFI is not seen to new remote control LCD.(It is hidden function.)

SAMSUNG AR09KSFSAWKNSA - Using the Smart A/C application - 1

text_image Timer Options Settings
  1. Press the Timer button to set the WiFi function.

- Press the Timer button for 4 seconds.

- ( ) will blink first, then(AP) appears on the remote controller display for few seconds and disappears. WiFi function will begin.

SAMSUNG AR09KSFSAWKNSA - Using the Smart A/C application - 2

• For detail information, please refer to Smart A/C application manual.

• Smart A/C application may not be available for some models.

SAMSUNG AR09KSFSAWKNSA - Using the Smart A/C application - 3

text_image AP 1:30AM Auto

Remote controller display

Cleaning the air conditioner

CAUTION

- Make sure to turn off the power of the indoor unit and cut-off the power supply before cleaning the air conditioner.

Cleaning the indoor unit

▶ Clean the product with a tepid damp cloth.
▶ Remove the dust accumulated in the gap of the product with a soft brush.

SAMSUNG AR09KSFSAWKNSA - Cleaning the indoor unit - 1

- Contact the service center when you clean the indoor unit heat exchanger because it needs to be disassembled.

SAMSUNG AR09KSFSAWKNSA - Cleaning the indoor unit - 2

natural_image Illustration of a hand cleaning an air conditioner cover (no text or symbols)

CAUTION

  • Do not clean the display using alkaline detergent.
  • Do not use sulfuric acid, hydrochloric acid, organic solvents (such as thinner, kerosene and acetone etc.) to clean the surface of the product or put any stickers on it. They may damage the surface of the air conditioner.

Cleaning the outdoor unit heat exchanger

▶ When dust accumulates on the heat exchanger, it may decrease cooling performance. Therefore, clean it regularly.
▶ Spray water to clean the dust.

SAMSUNG AR09KSFSAWKNSA - Cleaning the outdoor unit heat exchanger - 1

- If it is difficult to clean the outdoor unit heat exchanger on your own, contact service center.

CAUTION

- Be careful with the sharp edges on the outdoor unit heat exchanger.

SAMSUNG AR09KSFSAWKNSA - CAUTION - 1

natural_image Exterior view of a server rack unit with mesh grille and mounting base (no visible text or symbols)

Heat exchanger (Illustration may differ slightly depending on the models)

Cleaning the air conditioner

Removing the Air filter

There are two non-slip handles on the bottom of the filter. Hold the handles with your both hands and slightly push it up to release the hooks from the bottom side. Then, pull it down to remove the filter from the main body.

SAMSUNG AR09KSFSAWKNSA - Removing the Air filter - 1

text_image Air filter

Cleaning the air filter

Washable foam based air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing.

Remove the Air filter from the main body.

SAMSUNG AR09KSFSAWKNSA - Cleaning the air filter - 1

Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, rinse it with running water.

SAMSUNG AR09KSFSAWKNSA - Cleaning the air filter - 2

natural_image Hand holding a tool interacting with a grid-patterned object (no text or symbols visible)

Insert the Air filter back in its original position. Dry the Air filter in a ventilated area.

SAMSUNG AR09KSFSAWKNSA - Cleaning the air filter - 3

SAMSUNG AR09KSFSAWKNSA - Cleaning the air filter - 4

natural_image 3D wireframe model of a cylindrical structure with grid pattern, resting on a flat surface (no text or symbols)

SAMSUNG AR09KSFSAWKNSA - Cleaning the air filter - 5

  • Clean the Air filter every 2 weeks. Cleaning term may differ depending on the usage and environmental conditions. In dusty area, clean it once a week.
  • If the Air filter dries in a confined (or humid) area, odors may generate. If it occurs, re-clean and dry it in a well-ventilated area.

Reassembling the Air filter

  1. Put the filter on the main body and insert the hooks which are in the top of the Air filter into the main body. ①
  2. There's one hook in both side of the filter, press the surface of the Air filter softly and get the hooks into the main body. ②
  3. Press the bottom of the filter lightly to securely fix the main body. ③④⑤

SAMSUNG AR09KSFSAWKNSA - Reassembling the Air filter - 1

text_image Air filter ① ①

SAMSUNG AR09KSFSAWKNSA - Reassembling the Air filter - 2

natural_image Diagram of a car air conditioner unit with two labeled parts (②), showing internal structure and airflow direction (no text or symbols beyond labels)

SAMSUNG AR09KSFSAWKNSA - Reassembling the Air filter - 3

text_image Diagram of a car air conditioner with labeled parts showing hand placement for cooling system

Maintaining the air conditioner

If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.

  1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut-off the power supply. There may be internal damage if moisture is left in components.
  2. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness.

Periodical checks

Refer to the following chart to maintain the air conditioner properly.

Type DescriptionEvery 2 weeksEvery 3 monthsEvery 4 monthsOnce a year
Indoor unitClean the air filter (1)
Clean the condensate drain pan (2)
Thoroughly clean the heat exchanger (2)
Clean the cross fan (2)
Clean the condensate drain pipe (2)
Replace the remote controller batteries (1)
Outdoor unitClean the heat exchanger on the outside of the unit (2)
Clean the heat exchanger on the inside of the unit (2)
Clean the electric components with jets of air (2)
Verify that all the electric components are firmly tightened (2)
Clean the fan (2)
Verify that all the fan assembly is firmly tightened (2)
Clean the condensate drain pan (2)

● : This check mark requires checking the indoor/outdoor unit periodically. Follow the description to maintain the air conditioner properly.

SAMSUNG AR09KSFSAWKNSA - Periodical checks - 1

(1) The described operations should be performed more frequently if the area of installation is very dusty.
(2) These operations must always be performed by qualified personnel. For more detailed information, see the installation part in the manual.

Troubleshooting

Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.

PROBLEM SOLUTION
The air conditioner does not work at all.Check power status and then operate the air conditioner again.Plug in or switch on the circuit breaker and then operate the air conditioner again.Ensure Isolator is switch on.Check if you have set the Off Timer. Operate the air conditioner again by pressing thePowerbutton.
The temperature adjustment is not working.Check if you have selected Fan/Fast mode. In these modes, desire temperature is set to auto and you cannot adjust the temperature.
Cool/Warm air does not come out of the air conditioner.Check if the set temperature is higher(during Cool mode)/ lower(during Heat mode) than the current temperature. Press theTemp+or - button on the remote controller to change the set temperature.Check if the Air filter is blocked by dirt. If there is a lot of dust on the Air filter, cooling(heating) performance may decrease. Clean them frequently.Check if the outdoor unit is covered or installed near the obstacle Take the cover off and take the obstacle away.Check if the air conditioner is operating in defrost mode. When the ice formed in winter or the outdoor temperature is too low, the air conditioner operates in defrost mode automatically. In defrost mode, indoor fan stops and warm air does not come out.If the doors or windows are open, it may cause bad cooling (heating) performance.Close the doors and windows.Check if the air conditioner has just been turned on after stopping cooling or heating operation. In this case, just a fan will run to protect the outdoor unit compressor.Check if the pipe length is too long. When the pipe length exceeds maximum allowable pipe length, cooling (heating) performance may decrease.
Air flow adjustment is not working.Check if you have selectedgood'sleepIn this mode, you cannot adjust the air flow direction. (If thegood'sleepmode is operating in Heat mode, you can adjust the air flow direction.)

Troubleshooting

PROBLEM SOLUTION
Fan speed adjustment is not working.Check if you have selected Auto/Dry/Fastwood in these mode, fan speed is set to Auto and you cannot adjust the fan speed.
Remote controller is not working.Check if your batteries are depleted.Make sure nothing is blocking your remote controller sensor.Check that there are strong lighting apparatus near the air conditioner. Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves.
Timer function does not set.Check if you press theSet/Cancelbutton on the remote controller after you have set the time.
The indicator is blinking continuously.Press thePowebbutton or disconnect the power plug/switch off the auxiliary power switch.If the indicator is still blinking, contact the service center.
Odors permeate in the room during operation.Check if the appliance is running in a smoky area. Ventilate the room or operate the air conditioner in Fan mode for 1~2 hours.(We do not use smelly components in the air conditioner.)Check the Drains have been cleared Regular Maintenance.
Error is indicated.When an indoor unit indicator blinks, contact the nearest service center. Please ensure the error code is passed onto the service center when booking the service call.
Noise is generated.Depending on the status of the air conditioner usage, noise can be heard when refrigerant flow movement changes. It is normal.
Smoke is generated from the outdoor unit.If may not be a fire but it can be a steam generated by the defrost operation from outdoor heat exchanger during Heat mode in winter.
Water is dropping from the outdoor unit piping connection.Water may be generated because of the temperature difference. It is normal.
Indoor unit display indicates "d; d2d3"This is not a defect. If the air conditioner receives a Demand Response signal from the power supply utility, then the compressor and fans will be operated according to DRM mode(DRM 1, 2,3). The indoor unit display will indicate"d; d2 d3* see page 15 for more details about DRM mode.

Safety precautions

Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.

• Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components.
- Verify that installation and testing operations are performed by qualified personnel.
- Verify that the air conditioner is not installed in an easily accessible area.

General information

Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.
For maximum safety, installers should always carefully read the following warnings.
▶ Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.
This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.
The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the "Operating limits" table, included in the manual, shall immediately invalidate the warranty.
The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.
▶ Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.
In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG's technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.
▶ Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations should be performed by qualified personnel only.
The unit contains moving parts, which should always be kept out of the reach of children.
Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may cause electric shocks or fires.
▶ Do not place containers with liquids or other objects on the unit.
All the materials used for the manufacture and packaging of the air conditioner are recyclable.
The packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with current laws.
The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.

Installing the unit

IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes.

Upon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.)

Safety precautions

▶ After completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user.
Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries.
▶ To help prevent injury when accidentally touching the indoor unit fan, install the indoor unit at least 2.5 m above the floor.
The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.
Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs. The units' components must be accessible and that can be disassembled in conditions of complete safety either for people or things.
For this reason, where it is not observed as indicated into the Installation Manual, the cost necessary to reach and repair the unit (in safety, as required by current regulations in force) with slings, trucks, scaffolding or any other means of elevation won't be considered in-warranty and charged to end user.

Power supply line, fuse or circuit breaker

▶ Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards.
▶ Always verify that a suitable grounding connection is available.
▶ Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines.
▶ Always verify that the cut-off and protection switches are suitably dimensioned.
▶ Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual.
▶ Always verify that electric connections (cable entry, section of leads, protections...) are compliant with the electric specifications and with the instructions provided in the wiring scheme.
Always verify that all connections comply with the standards applicable to the installation of air conditioners.

Choosing the installation location

Indoor unit

For Wi-Fi Air-conditioner installation, select indoor unit location near to wireless router.
In case Wi-Fi signal strength weakened, Smart APP may be disconnected depending on the Wi-Fi signal strength.
▶ Where airflow is not blocked.
▶ Where cool air can be distributed throughout the room.
▶ Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram.
▶ Wall that prevents vibration and is strong enough to hold the product weight.
▶ Out of the direct sunlight.
▶ 1 m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated).
As far away as possible from the fluorescent and incandescent lights (so that the remote controller can be operated well).
▶ A place where the air filter can be replaced easily.
- Don't install directly above electronics equipment as leaking water may cause damage if not serviced. (eg. Computers, TV, etc).

Outdoor Unit

▶ Where it is not exposed to strong wind
▶ Well ventilated and dustless places
▶ Where possible keep out of sunlight and rain
▶ Where neighbors are not annoyed by operation sound or hot air
▶ Solid wall or support that prevents vibration and is strong enough to hold the product weight
▶ Where there is no risk of flammable gas leakage
▶ When installing the unit at a high place be sure to fix the unit legs
▶ 3 m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)
▶ Install the unit horizontally
▶ Place where drained water does not become any problem.
▶ Place with no plants (especially climbing plants) and where small animal can not access.
▶ Outdoor unit should not be place higher than 2.4 m or directly under eaves for accessibility for service and OH&S reasons.

SAMSUNG AR09KSFSAWKNSA - Outdoor Unit - 1

  • Avoid the following places to prevent malfunction of the unit
  • Where there is machine oil - Salty environment such as seaside areas
  • Where sulfide gas exists - Other special atmosphere areas

SAMSUNG AR09KSFSAWKNSA - Outdoor Unit - 2

text_image Outdoor Unit Outer wall Indoor Unit Cut insulation to have rainwater drained

SAMSUNG AR09KSFSAWKNSA - Outdoor Unit - 3

text_image 100 mm or more 125 mm or more 125 mm or more Wrap the refrigerant pipes and the drain hose with the absorbent pad and vinyl tape. Refer to page 56 for further details. You can select the direction of draining (left or right). CAUTION 'L' m as maximum pipe length and 3 m as minimum pipe length. (It will reduce noise and vibration) 'H' meters maximum total pipe height 'L' meters maximum total pipe length Model Pipe Length Pipe Height Minimum Maximum Maximum

SAMSUNG AR09KSFSAWKNSA - Outdoor Unit - 4

Make an U-trap(A) on the pipe (which is connected to the indoor unit) at outer wall and cut the bottom part of the insulation (about 10 mm) to prevent rainwater from getting inside through the insulation. However, be careful not to damage the pipe.

SAMSUNG AR09KSFSAWKNSA - Outdoor Unit - 5

natural_image Diagram of a mechanical or electrical component with a coiled wire and grid pattern, no visible text or symbols

Make at least one round: It will help reduce noise and vibration.

ModelPipe Length Pipe Height
MinimumMaximumMaximum
**09/12**3 158
**18/24**3 3015
**30**3 3015

* The appearance of the unit may be different from the diagram depending on the model.

Choosing the installation location

Space Requirements for Outdoor Unit

When installing 1 outdoor unit

◆ Figure Description

Top view Side view
SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 1SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 2

• , Air flow direction.

(Unit: mm)

◆ When the air outlet is opposite the wall

SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 3

text_image 300 or more

◆ When the air outlet is towards the wall

SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 4

text_image 1500 or more

◆ When 3 sides of the outdoor unit are blocked by the wall

SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 5

text_image 300 or more 150 or more 600 or more

◆ The upper part of the outdoor unit and the air outlet is towards the wall

SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 6

text_image 2000 or more 1500 or more

◆ The upper part of the outdoor unit and the air outlet is opposite the wall

SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 7

text_image 500 or more 300 or more

When the walls are blocking front and the rear side of the outdoor unit

SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 8

text_image 300 or more 1500 or more

(Unit: mm)

◆ When the air outlet is towards the wall
SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 9

text_image 1500 or more

◆ When 3 sides of the outdoor unit are blocked by the wall
SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 10

text_image 300 or more 300 or more 600 or more 600 or more 600 or more

(Unit : mm)

When the walls are blocking front and the rear side of the outdoor units
SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 11

text_image 600 or more 600 or more 300 or more 1500 or more

When front and rear side of the outdoor unit is towards the wall

SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 12

text_image 1500 or more 600 or more 3000 or more 3000 or more 200 or more

When the upper part of the outdoor unit and the air outlet is opposite the wall
SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 13

text_image 500 or more 300 or more 300 or more 500 or more

SAMSUNG AR09KSFSAWKNSA - When installing 1 outdoor unit - 14

- If installation is done in inappropriate space, unit may generate sound and cause bad effect on the product. - Installation must be done in level and in a place where vibration will not cause any effect.

accessories

The following accessories are supplied with the air conditioner:

SAMSUNG AR09KSFSAWKNSA - accessories - 1

NOTE

• The number of each accessory is indicated in parentheses.

Accessories in the indoor unit case

Installation Plate (1) **09/12** (04 frame)SAMSUNG AR09KSFSAWKNSA - accessories - 2Installation Plate (1) **18/24/30** (05 frame)SAMSUNG AR09KSFSAWKNSA - accessories - 3Remote controller (1)SAMSUNG AR09KSFSAWKNSA - accessories - 4Batteries for Remote controller (2)SAMSUNG AR09KSFSAWKNSA - accessories - 5User's & Installation Manual (1)SAMSUNG AR09KSFSAWKNSA - accessories - 6Wi-Fi Manual (1) AR**KSWS***SAMSUNG AR09KSFSAWKNSA - accessories - 7
Remote Control Holder (1)SAMSUNG AR09KSFSAWKNSA - accessories - 8M4 x 16 Tapped Screws (2)SAMSUNG AR09KSFSAWKNSA - accessories - 9Cap Screws(2)SAMSUNG AR09KSFSAWKNSA - accessories - 10Guide Right(1)SAMSUNG AR09KSFSAWKNSA - accessories - 11Guide Left(1)SAMSUNG AR09KSFSAWKNSA - accessories - 12

Accessories in the outdoor unit case

Drain Plug (1) Rubber Leg (4)
SAMSUNG AR09KSFSAWKNSA - accessories - 13SAMSUNG AR09KSFSAWKNSA - accessories - 14

SAMSUNG AR09KSFSAWKNSA - accessories - 15

NOTE

  • The flare nuts are attached to the end of each pipe of an evaporator or a service port.
    Use the nuts when connecting the pipes.
  • The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below.

Tools required for installation

General Tools

• Vacuum Pump(Backward flowing prevention) • Manifold Gauge • Stud Finder
- Torque Wrench - Pipe Cutter - Reamer - Pipe Bender - Spirit Level
- Screw Driver - Spanner - Drill - L Wrench - Measuring Tape

Tools for test operations

- Thermometer - Resistance Meter - Electroscope

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

  • Right (A)
  • Left (B)
  • Underside_right (C)
  • Rear_right or left (D)

* Direction of pipe
SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 1

text_image A D C D B

SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 2

• You can install the refrigerant pipe in the left/right/bottom, or the rear side of the indoor unit.
- If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

  1. Disassemble the cover panel as described in page 42\~43.

  2. Remove the Hanger plate from the indoor unit.

(1) Unscrew 2 screws that fixes the Hanger plate to the indoor unit.
(2) Push the hooks (on the bottom part of the indoor unit) up to release the installation plate from the hooks that holds it.
(3) Pull the installation plate to release it completely from the indoor unit.

SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 3

text_image Screw

SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 4

natural_image Hand inserting a component into a device (no text or symbols visible)

SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 5

natural_image Illustration of hands installing or adjusting a computer motherboard with visible slots and buttons (no text or symbols)
  1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards.

Pipe hole (∅65 mm) Pipe hole (∅65 mm)
SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 6

text_image A B C

SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 7

text_image A B C D

(Unit : mm)

Model A B C D
**09/12 **36 190 81 36
**18/24/30**33 110 110 33

SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 8

• Make sure to drill only one hole after choosing the direction of the pipe.

  1. Fix the indoor unit.

If you fix the indoor unit on a wall

(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.

SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 9

- If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20 mm.

SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 10

text_image Plastic Anchor <20 mm Wall

If you fix the indoor unit on a window frame

(1) Determine the positions of the wooden uprights to be attached to the window frame.
(2) Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.
(3) Attach the installation plate to the wooden upright using tapping screws.

If you fix the indoor unit on a gypsum board

(1) Use stud finder to find out locations of the studs.
(2) Fix the plate hanger on two studs.

Fixing the installation plate

SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 1

  • Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.
    • Fix the installation plate without inclining to one side.

SAMSUNG AR09KSFSAWKNSA - Fixing the installation plate - 2

- Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not strong enough to withstand the product weight, the unit could fall and cause injury.

Assembling the hanger screw

Use 2 screws to fix the indoor unit with hanger plate as shown in the picture.

SAMSUNG AR09KSFSAWKNSA - Assembling the hanger screw - 1

text_image Screw

Disassembling/Assembling the Cover panel for indoor unit installation

SAMSUNG AR09KSFSAWKNSA - Disassembling/Assembling the Cover panel for indoor unit installation - 1

text_image QR code image containing encoded data, no visible human-readable text

Please scan this QR code for detail video of indoor unit installation.

In order to install the indoor unit, you must disassemble the cover panel first. Please proceed following instructions to disassemble and assemble the cover panel. Hooks (on the cover panel) may get damaged if you apply excessive force as you disassemble and assemble the cover panel. Please follow the following instructions.

Removing the screws

Cover panel is assembled on the bottom part of the indoor unit (as shown in the illustration) and it is fastened with screws. Remove the Cap screw first and unfasten the screws so that you can disassemble the cover panel.

SAMSUNG AR09KSFSAWKNSA - Removing the screws - 1

text_image Cap Screw Cover Panel

Removing the Cover panel (Before mounting the indoor unit)

The bottom panel fits the main body using the side, center, and bottom hooks as shown. Unlock the side hooks first, and then unlock the center and bottom hooks.

Check the location of the hooks before removing the cover panel.

SAMSUNG AR09KSFSAWKNSA - Removing the Cover panel (Before mounting the indoor unit) - 1

text_image Side hooks Center hooks Bottom hooks

▶ Location of the hooks on the central part

Number and location of the hooks
SAMSUNG AR09KSFSAWKNSA - Removing the Cover panel (Before mounting the indoor unit) - 2
SAMSUNG AR09KSFSAWKNSA - Removing the Cover panel (Before mounting the indoor unit) - 3
Center hookBottom hook
SAMSUNG AR09KSFSAWKNSA - Removing the Cover panel (Before mounting the indoor unit) - 4SAMSUNG AR09KSFSAWKNSA - Removing the Cover panel (Before mounting the indoor unit) - 5

* For specific Hook location and quantity, please refer to cover panel with indicating arrows based on physical goods.

Removing the hooks on the side

SAMSUNG AR09KSFSAWKNSA - Removing the Cover panel (Before mounting the indoor unit) - 6

natural_image Illustration of hands using a tool to cut or spread a rectangular object, no text or symbols present

Removing the hooks on the central part

SAMSUNG AR09KSFSAWKNSA - Removing the Cover panel (Before mounting the indoor unit) - 7

natural_image Diagram of a mechanical assembly with arrows indicating force or movement, and an inset showing hand positioning (no text or symbols)

* Caution (fragile)

- Gently press the both side of the cover panel inwards (①) and release the hooks on both sides(②).

* Caution (fragile)

- Use both hands

- Release each hook by pushing it up at an angle.

Assembling the Cover panel (After mounting the indoor unit)

To assemble the Cover panel, proceed in reverse order of disassembling.

Use both hands for assembling and be extra careful not to damage the pipes and drain hose.

Lock the side, center, and bottom hooks in this sequence. Tighten the bottom panel with the screws, and close the screw holes with their cap.

SAMSUNG AR09KSFSAWKNSA - Assembling the Cover panel (After mounting the indoor unit) - 1

natural_image Illustration of a hand holding a device with arrows indicating motion or force (no text or symbols present)

SAMSUNG AR09KSFSAWKNSA - Assembling the Cover panel (After mounting the indoor unit) - 2

natural_image Close-up of a mechanical component with a circular outline and internal structure (no visible text or symbols)

SAMSUNG AR09KSFSAWKNSA - Assembling the Cover panel (After mounting the indoor unit) - 3

natural_image Illustration of a hand holding a curved object with an upward arrow, enclosed in a circle (no text or symbols)

SAMSUNG AR09KSFSAWKNSA - Assembling the Cover panel (After mounting the indoor unit) - 4

natural_image Simple diagram showing a pulley system with an upward arrow and a hanging weight inside a circular frame (no text or symbols)

SAMSUNG AR09KSFSAWKNSA - Assembling the Cover panel (After mounting the indoor unit) - 5

natural_image Illustration of a hand holding a finger with a pointer and arrow, inside a circular frame (no text or symbols)

Connecting the assembly cable

Cable specification

ModelPower cable(Outdoor Unit)Interconnection cable(Indoor-Outdoor)Type GL
**09/12** **18/24** **30**3G, 1.5 mm ^2 ,H07RN-F(**09/12**)3G, 2.5 mm ^2 ,H07RN-F(**18/24**)3G, 4.0 mm ^2 ,H07RN-F(**30**)Power Supply3 x 1.0 mm ^2 , H07RN-F(60245 IEC66)10 A (***09/12** )20 A (***18/24** )25 A (**30** )
F1/F2communication2 x 0.75 mm ^2 , H05RN-F(60245 IEC57)
DRED Connected Wire -4 x 0.75 mm ^2 , H05RN-F(60245 IEC57)(Only for reference)-

SAMSUNG AR09KSFSAWKNSA - Connecting the assembly cable - 1

  • Connect the power cable to the auxiliary circuit breaker. If every pole fails to connect to the power supply, it must be incorporated in a wire with a contact opening of ≥ 3 mm.
    • Use shield cable (Category 5; less than 50pF/m) for noisy environmental site.
  • Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord.

(Code designation IEC: 60245 IEC 66/CENELEC: H07RN-F, IEC: 60245 IEC 57/CENELEC: H05RN-F)

Connecting the cable

Electrical work

(1) For electrical and earth works, comply with the 'technical standards of electrical installations' and the the 'wiring regulations' of the Local wiring regulations.
(2) Tighten the terminal block screw to 1.2 \~ 1.8 N·m (12 \~ 18 kgf·cm).
(3) Precautions when connecting terminal blocks of the indoor unit

▶ Before connecting, make sure the connecting part of the terminal socket is facing upwards.

SAMSUNG AR09KSFSAWKNSA - Electrical work - 1

SAMSUNG AR09KSFSAWKNSA - Electrical work - 2
Upside down

SAMSUNG AR09KSFSAWKNSA - Electrical work - 3
The terminal socketis damaged.

SAMSUNG AR09KSFSAWKNSA - Electrical work - 4
There is no ring terminal to cover the wire.

▶ There must be no space between the terminal and the screw when connected.

- Any remaining space may become a fire hazard due to overheating of the electrical contact.

SAMSUNG AR09KSFSAWKNSA - Electrical work - 5

SAMSUNG AR09KSFSAWKNSA - Electrical work - 6

SAMSUNG AR09KSFSAWKNSA - Electrical work - 7
The terminal socket is upside down.

SAMSUNG AR09KSFSAWKNSA - Electrical work - 8
Either the screw is not fitted properly or there is a space between the screw and the ring terminal.

SAMSUNG AR09KSFSAWKNSA - Electrical work - 9

- For the terminal block wiring, use a wire with a ring terminal socket only. Regular wires without a ring terminal socket may become a fire hazard due to overheating of the electrical contact during a wiring work.

* When you install the unit, make first refrigerant connections and then electrical connections.

Connect the air conditioner to grounding system before performing the electrical connection.

If unit is uninstalled, first disconnect electrical cables, then refrigerant connections.

If the outdoor unit is more than 5.5 meters away from the indoor unit, you must extend the cable. The maximum length of the cable is 15(* *09/12***) / 30(* *18/24/30***) meters.

  1. Extend the assembly cable if necessary.

SAMSUNG AR09KSFSAWKNSA - Electrical work - 10

- Do not connect two or more different cables to extend the length. It may cause fire.

  1. Open the cover panel.
  2. Remove the screw securing the connector cover.
  3. Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below)

SAMSUNG AR09KSFSAWKNSA - Electrical work - 11

• Each wire is labeled with the corresponding terminal number.

  1. Pass the other end of the cable through the 65 mm hole in the wall.
  2. Close the connector cover by tightening the screw carefully.
  3. Close the cover panel.
  4. Remove the terminal board cover on the side of the outdoor unit.
  5. Connect the cables to the terminals as seen in the picture.

SAMSUNG AR09KSFSAWKNSA - Electrical work - 12

• Each wire is labeled with the corresponding terminal number. • DRED(Demand Response Enabling Device) may be supplied by the power supply utility.

SAMSUNG AR09KSFSAWKNSA - Electrical work - 13

text_image Indoor unit Outdoor unit DRED C DRS/3 DRV2 DRM1 **09/12/18/24** **30** Indoor unit 1(L) 2(N) F1 F2 1(L) 2(N) F1 F2 L N Outdoor unit F1 F2 Indoor unit 1(L) 2(N) F1 F2 1(L) 2(N) F1 F2 1(L) 2(N) L R Outdoor unit F1 F2 DRED C DRM3 DRM2 DRM1 * DRED terminal block : Connection to DRED Relay or Switch.

SAMSUNG AR09KSFSAWKNSA - Electrical work - 14

• Also circular terminal must be matched with screw size in terminal block.
• After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.
- Please ensure that Power & Communication cables are separated, they must not be in the same cable.
• Power & Communication cable shall not exceed 30m.
- Do not connect 240 V direct to DRED's or F1/F2 terminal blocks.

Connecting the assembly cable

  1. Connect the grounding conductor to the grounding terminals.
  2. Close the terminal board cover by tightening the screw carefully.

SAMSUNG AR09KSFSAWKNSA - Connecting the assembly cable - 1

• In Russia and Europe, consult with the supply authority to determine the supply system impedance before installation.

SAMSUNG AR09KSFSAWKNSA - Connecting the assembly cable - 2

  • Connect the wires firmly so that wires can not be pulled out easily. (If they are loose, it could cause burn-out of the wires.)
  • Connect the wires according to color codes, referring to the wiring diagram.
    • The power cable and the interconnection cable should be selected according to the specification in page 44.

DRED wiring diagram

Outdoor unit
SAMSUNG AR09KSFSAWKNSA - DRED wiring diagram - 1

text_image ASSY Control out DRED SUB PBA COMMON DRM3 DRM2 DRM1 DRED Controller

Installing and connecting the assembly pipe of the indoor unit

Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.

There are 2 refrigerant pipes of different diameters:

• The smaller one is for the liquid refrigerant
• The larger one is for the gas refrigerant

A short pipe is already fitted to the air conditioner. You may need to extend the pipe using the assembly pipe (optional).

The connection procedure for the refrigerant pipe varies according to the exit position of the pipe when facing the wall:

• Right(A)
- Left(B)
- Underside(C)
- Rear

  1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit unless you connect the pipe directly from the rear.
  2. Smooth the cut edges.
  3. Remove the protection caps of the pipes and connect the assembly pipe to each pipe. Tighten the nuts first with your hands, and then with a torque wrench, applying the following torque:

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the assembly pipe of the indoor unit - 1

natural_image Technical diagram of a mechanical component with labeled parts A, B, and C (no text or symbols beyond labels)
Outer DiameterTorque
N·m kgf·cm
ø6.35 mm 14~18 140~180
ø9.52 mm 34~42 350~430
ø12.70 mm 49~61 500~620
ø15.88 mm 68~82 690~830

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the assembly pipe of the indoor unit - 2

• If you want to shorten or extend the pipes, refer to page 48\~49.

  1. Cut off the remaining foam insulation.
  2. If necessary, bend the pipe to fit along the bottom of the indoor unit.

Then pull it out through the appropriate hole.

▶ The pipe should not project from the rear of the indoor unit.
▶ The bending radius should be 100 mm or more.

  1. Pass the pipe through the hole in the wall.

  2. For further details on how to connect to the outdoor unit and evacuate the air, refer to page 52\~54.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the assembly pipe of the indoor unit - 3

- The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test; refer to page 56 for further details.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the assembly pipe of the indoor unit - 4

- Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, the flare may break and cause refrigerant gas leakage. - DO NOT WALL UP THE PIPE CONNECTION! All refrigerant pipe connection must be easy accessible and serviceable.

Installing and connecting the assembly pipe of the indoor unit

Assembling the hanger screw and guide

  1. Cut out the knock-out piece according to the drain hose direction before fixing the indoor unit.
  2. Fix the indoor unit on the wall.
    Pass the cables, pipes and hose through the hole which would be connected to the outdoor unit.
  3. Use 2 screws to fix the indoor unit as shown in the picture.

  4. Assemble the Guide into the position where the knock-out piece has been cut out before.

There're three hooks on the Guide, they must be totally fixed to the unit.

* The method of assembling the Guide is same whether it's on right or on left.

SAMSUNG AR09KSFSAWKNSA - Assembling the hanger screw and guide - 1

text_image Left and right each has one knock-out piece Screw Guide

Evacuating the indoor unit

The indoor unit is supplied with inert gas (nitrogen).

Before installing the unit, check if nitrogen gas flow out of indoor unit.

If this one isn't true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit.

1. Unscrew the caps at the end of each pipe.

▶ All inert gas exhausts from the indoor unit.

SAMSUNG AR09KSFSAWKNSA - Unscrew the caps at the end of each pipe. - 1

- To prevent dirt or foreign substances from getting into the pipes during installation, do NOT remove the caps completely until you are ready to connect the pipes.

SAMSUNG AR09KSFSAWKNSA - Unscrew the caps at the end of each pipe. - 2

- The remaining air in the Refrigeration cycle, which contains moisture, may cause malfunction on the compressor.

• Always contact the service center or a professional installation agency for product installation.

SAMSUNG AR09KSFSAWKNSA - Unscrew the caps at the end of each pipe. - 3

text_image Pipes Unscrew the caps

Cutting or extending the pipe

The length of the pipe can be:

• Extended up to : see table page 37
- Shorten up to: see page 37

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 1

If you need a pipe longer than 5 meters:

• You must add refrigerant to the pipes; otherwise, the indoor unit may freeze.

  1. Make sure that you have all the required tools (pipe cutter, reamer, flaring tool and pipe holder).
  2. If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut edge remains at 90^ with the side of the pipe (see below examples of correct and incorrect cut edges).

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 2

text_image Pipe cutter Pipe

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 3

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 4

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 5

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 6

  1. To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer.

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 7

• Face the pipe down while removing the burrs to make sure that burrs do not get in to the pipe.

  1. Put a flare nut slightly into the pipe and modify the flare.

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 8

text_image D A Pipe Flare 90°±2° B 45 23° R 0.4~0.8
Outer Diameter (D)Depth (A)Flaring Size (B)
ø6.35 mm 1.3 mm8.7 - 9.1 mm
ø9.52 mm 1.8 mm12.8 - 13.2 mm
ø12.70 mm 2.0 mm16.2 - 16.6 mm
ø15.88 mm 2.2 mm19.3 - 19.7 mm
  1. Check if you flared the pipe correctly (see examples of incorrectly flared pipes below).

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 9
Correct

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 10
Inclined

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 11
Damaged Surface

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 12
Cracked

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 13
Uneven Thickness

  1. Align the pipes to connect them easily. Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque:

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 14

text_image Flare nut Indoor outlet pipe Connecting pipe
Outer DiameterTorque
N·m kgf·cm
ø6.35 mm14~18140~180
ø9.52 mm34~42350~430
ø12.70 mm49~61500~620
ø15.88 mm68~82690~830

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 15

- Excessive torque can be cause of gas leakage. If extending pipe by welding/brazing please ensure nitrogen is used during welding/brazing process. The joint must be accessible and serviceable.

  1. For further details on how to connect to the outdoor unit and evacuate the air, refer to page 52\~54.

SAMSUNG AR09KSFSAWKNSA - Cutting or extending the pipe - 16

- Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, the flare may break and cause refrigerant gas leakage.

Installing and connecting the drain hose of the indoor unit

When installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain hose through the 65 mm hole drilled in the wall, check the followings:

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the indoor unit - 1

text_image Wall Indoor unit Drain hose

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the indoor unit - 2

natural_image Pure mechanical diagram showing a curved component and cross-section with hatched fill (no text or symbols)

The drain hose must NOT slant upwards.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the indoor unit - 3

natural_image Technical diagram of a mechanical assembly with no visible text or symbols

The end of the drain hose must NOT be placed under water.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the indoor unit - 4

natural_image Technical diagram showing mechanical assembly with no visible text or symbols

The drain hose must not be bent.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the indoor unit - 5

text_image 5cm less

Keep a clearance of at least 5 cm between the end of the drain hose and the ground.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the indoor unit - 6

text_image Ditch

Do not place the end of the drain hose in a hollow.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the indoor unit - 7

text_image After completing the installation of the drain hose, pour water into the drain pan to check whether the hose is well drained.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the indoor unit - 8

text_image 1) Correct connection Drain hose Pipe

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the indoor unit - 9

text_image 2) Incorrect connection Drain hose Pipe

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the indoor unit - 10

  • Don't tie drain hose to the assembly pipe which may lead to water leakage.
    • If the diameter of the connection hose is smaller than the product's drain hose, water leakage may occur.

Drain hose installation

  1. If necessary, connect the 2 meter extension drain hose to the drain hose.
  2. If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.
  3. Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose tightly with a clamp.

SAMSUNG AR09KSFSAWKNSA - Drain hose installation - 1

• If you do not use the other drain hose hole, block it with a rubber stopper.

  1. When extending the Drain Hose, hold the end of Drain Hose and Extended Hose, rotate and insert the drain hose into Extended hose for 40\~45 mm. Make sure the two hoses are firmly connected, there is no water leakage.

SAMSUNG AR09KSFSAWKNSA - Drain hose installation - 2

text_image Drain hose hole
  1. Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap the each side of connection by 20 mm.

SAMSUNG AR09KSFSAWKNSA - Drain hose installation - 3

text_image Drain hose Extension drain hose 40~45 mm Drain hose Extension drain hose 20 mm 20 mm or more or more Vinyl Tape Foam Insulation
  1. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.
  2. Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture.
  3. Using natural drainage method, check the drainage is normal.

SAMSUNG AR09KSFSAWKNSA - Drain hose installation - 4

text_image Shield Drain hose Extension drain hose

SAMSUNG AR09KSFSAWKNSA - Drain hose installation - 5

- The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page 56 for further details.

SAMSUNG AR09KSFSAWKNSA - Drain hose installation - 6

• Make sure the installed direction of the drain hose is correct. Inadequate installation may cause condensate water leakage.
- If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.
• DO NOT WALL UP THE DRAIN HOSE CONNECTION! Drain hose connection must be easy accessible and serviceable.

Changing direction of the drain hose

Change the direction only when it is necessary.

  1. Detach the rubber cap with the pliers.
  2. Detach the drain hose by pulling it and turning to the right.
  3. Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan.

SAMSUNG AR09KSFSAWKNSA - Changing direction of the drain hose - 1

text_image Screw Screw hole Drain hose
  1. Attach the rubber cap with a screwdriver by turning it to the left until it fixes to the end of the groove.
  2. Check for leakage on both side of the drain outlet.

Pour the water in direction of arrow.

SAMSUNG AR09KSFSAWKNSA - Changing direction of the drain hose - 2

natural_image Diagram of a washing machine with two circular insets showing internal components (no text or labels)

* Direction of the drained water

SAMSUNG AR09KSFSAWKNSA - Changing direction of the drain hose - 3

SAMSUNG AR09KSFSAWKNSA - Changing direction of the drain hose - 4

text_image Drain pan outlet Rubber cap

SAMSUNG AR09KSFSAWKNSA - Changing direction of the drain hose - 5

• Make sure the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part.

Installing and connecting the drain hose of the outdoor unit

While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following.

  1. Insert the drain plug into the drain hole on the underside of the outdoor unit.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the outdoor unit - 1

• To avoid drain plug from contacting the ground, secure gap between the ground and the bottom surface of the outdoor unit.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the outdoor unit - 2

text_image Drain hole Drain plug
  1. Connect a drain hose to the drain plug.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the outdoor unit - 3

text_image Bottom surface of outdoor unit Drain hole Drain plug Drain hose
  1. Ensure that condensation draining is adequate.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the outdoor unit - 4

- In areas with heavy snow fall, piled snow could block the air intake. To avoid this incident, install a frame that is higher than estimated snow fall. In addition, install a snow-proof hood to avoid snow from piling on the outdoor unit.

SAMSUNG AR09KSFSAWKNSA - Installing and connecting the drain hose of the outdoor unit - 5

text_image Snow-proof hood Estimated snow fall Frame Ground

Evacuating the connected pipes

The outdoor unit is loaded with sufficient R-410A refrigerant. Do not vent R-410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 2088.

You should evacuate the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling capacity and malfunction. Use Vacuum Pump as seen in the picture.

SAMSUNG AR09KSFSAWKNSA - Evacuating the connected pipes - 1

- When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high. It may cause explosion and injury.

  1. Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut.
  2. Tighten the flare nut first with your hands, and then with a torque wrench, applying the following torque.

SAMSUNG AR09KSFSAWKNSA - Evacuating the connected pipes - 2

• Excessive torque can be cause of gas leakage.

SAMSUNG AR09KSFSAWKNSA - Evacuating the connected pipes - 3

- Make the electrical connection and leave the system into "stand by mode". Do not turn on the system! This is necessary for better vacuum operation (full OPEN position of Electronic Expansion Valve - EEV -).

  1. Connect the charging hose of the low-pressure side of manifold gauge to a gas service port as seen in the picture.
  2. Open the valve of the low pressure side of manifold gauge counterclockwise.
  3. Evacuate the air in the connected pipes using the vacuum pump for about 15 minutes.

▶ Make sure that pressure gauge shows -0.1 MPa(-76 cmHg) after about 10 minutes. This procedure is very important to avoid a gas leak.
▶ Close the valve of the low pressure side of manifold gauge clockwise.
▶ Turn off the vacuum pump.
▶ Check for 2 minutes if there is any pressure change.
▶ Remove the hose of the low pressure side of manifold gauge.

  1. Set a valve cork of liquid and gas service port to the open position.

SAMSUNG AR09KSFSAWKNSA - Evacuating the connected pipes - 4

flowchart
graph LR
    A["Outdoor unit"] --> B["Indoor unit"]
    B --> C["Gas pipe side"]
    B --> D["Liquid pipe side"]
Outer DiameterTorque
N·mkgf·cm
ø6.35 mm14~18140~180
ø9.52 mm34~42350~430
ø12.70 mm49~61500~620
ø15.88 mm68~82690~830

SAMSUNG AR09KSFSAWKNSA - Evacuating the connected pipes - 5

text_image Manifold gauge Valve Gas service port Liquid service port Vacuum Pump (Backward flowing prevention)

Adding Refrigerant

Add refrigerant charge according to table below:

If you use a pipe longer than 5 m,

'A' g of refrigerant R-410A must be added for each extra meter.

If you use a pipe shorter than 5 m,

The evacuating time is normal.

Refer to the Service Manual for further details.

Model A
**09/12**15
**18/24**15
**30**40

SAMSUNG AR09KSFSAWKNSA - Adding Refrigerant - 1

• The remaining air in the Refrigeration cycle, which contains moisture, may cause malfunction on the compressor.
• Always contact the service center or a professional installation agency for product installation.

Evacuating the connected pipes

Charging the refrigerant under conditions of liquid by using a liquid pipe

R-410A is a mixed type of refrigerant. It is necessary for recharging under conditions of liquid. When recharging refrigerant from the refrigerant cylinder to the equipment, follow the instructions below.

  1. Before recharging, check whether the cylinder has a siphon or not.

There are two ways to recharge the refrigerant.

Cylinder with siphon
SAMSUNG AR09KSFSAWKNSA - Charging the refrigerant under conditions of liquid by using a liquid pipe - 1

text_image Siphon

▶ Charge the refrigerant standing the cylinder upright.

Cylinder without siphon
SAMSUNG AR09KSFSAWKNSA - Charging the refrigerant under conditions of liquid by using a liquid pipe - 2

▶ Charge the refrigerant turning the cylinder upside down.

SAMSUNG AR09KSFSAWKNSA - Charging the refrigerant under conditions of liquid by using a liquid pipe - 3

- If R-410A refrigerant is charged with gas, the composition of the charged refrigerant changes and the characteristics of the equipment vary.

- During the measuring operation of refrigerant quantity added use electronic scales. If cylinder doesn't have syphon, upset it.

Performing the gas leak tests

Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate).

SAMSUNG AR09KSFSAWKNSA - Performing the gas leak tests - 1

text_image Diagram showing a device connected to a wall-mounted device with labeled parts A and B, illustrating electrical or mechanical connections.

SAMSUNG AR09KSFSAWKNSA - Performing the gas leak tests - 2

natural_image Pure mechanical assembly diagram showing two bolted joint configurations labeled C and D (no text or symbols beyond labels)

Test part for outdoor unit
SAMSUNG AR09KSFSAWKNSA - Performing the gas leak tests - 3

text_image Tightening torque for body cap (Refer to the table) Spindle Charging core R-22: Diameter of the screw - 7/16-20UNF R-410A: Diameter of the screw - 1/2-20UNF Tightening torque for charging port cap (Refer to the table)

Test part for indoor unit

▶ Before inspecting the leakage, use a torque wrench to close the cap for the service valve. (Comply with a tightening torque for each size of the diameter, and tighten the cap firmly to prevent any leakage.).
▶ To check for any possible leakage, insert inert gas into the pipes connected to indoor/outdoor units and check the connection part of the indoor/outdoor units with soap lather or liquid for leakage test.

Outer Diameter (mm)Tightening torque
Body cap (N·m)Charging port cap (N·m)
ø 6.3520 ~ 2510 ~ 12
ø 9.5220 ~ 25
ø12.7025 ~ 30
ø15.8830 ~ 35
ø19.0535 ~ 40

To check for gas leaks on the outdoor unit,

Check the valve A and B using a leak detector.

(1 N·m = 10 kgf·cm)

To check for gas leaks on the indoor unit,

Check the flare nut C and D using a leak detector.

Leak test with nitrogen (before opening valves)

In order to detect basic refrigerant leaks, before recreating the vacuum and recirculating the R-410A, it's responsible of installer to pressurize the whole system with nitrogen (using a cylinder with pressure reducer) at a pressure above 40 bar (gauge).

Leak test with R-410A (after opening valves)

Before opening valves, discharge all the nitrogen from the system and create vacuum according to page 52\~54.

After opening valves, check leaks using a leak detector for refrigerant.

Pump down (before disconnecting the refrigerant connections for unit repair, removal or disposal)

Pump-down is an operation intended to collect all the system refrigerant in the outdoor unit.

This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere.

▶ Shut off the liquid valve with the Allen wrench.
▶ Turn the system on in cooling with fan operating at high velocity.
(Compressor will immediately start, provided 3 minutes have elapsed since the last stop).
▶ After 2 minutes of operation, shut the suction valve with the same wrench.
▶ Turn the system off and switch mains supply off.
▶ Disconnect tubing. After disconnection, protect valves and tubing ends from dust.
▶ Compressor damage may occur if run at a negative suction pressure.

Fixing the indoor unit in place

Perform the following work on the area where gas leak test was done priory.

After checking for gas leaks in the system, insulate the pipe, hose and cables.

Then place the indoor unit on the installation plate.

  1. To minimise condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes.
  2. Wind the pipe, assembly cable and drain hose with vinyl tape.
  3. Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit.
  4. Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place.

SAMSUNG AR09KSFSAWKNSA - Fixing the indoor unit in place - 1

• Make sure pipe does not move when you install the indoor unit on an installation plate.

  1. Wrap the rest of the pipe with vinyl tape.

  2. Attach the pipe to the wall using clamps (optional).

SAMSUNG AR09KSFSAWKNSA - Fixing the indoor unit in place - 2

text_image Insulation Pipes

SAMSUNG AR09KSFSAWKNSA - Fixing the indoor unit in place - 3

text_image Installation plate Vinyl tape Connecting wires Drain hose Connecting pipes

Fixing the outdoor unit in place

Install the outdoor unit in level on a stable base to help avoid the generation of noise and vibration, especially when installing the unit close to a neighbor.

If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an appropriate support (wall or ground).

  1. Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly.

  2. Fix the outdoor unit in level to an appropriate support using anchor bolts.

  3. If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly.

SAMSUNG AR09KSFSAWKNSA - Fixing the outdoor unit in place - 1

- Secure the rubber leg to help prevent the generation of noise and vibration.

SAMSUNG AR09KSFSAWKNSA - Fixing the outdoor unit in place - 2

text_image 'X' mm Y' mm Rubber leg
Model X Y
AR09/12KSFS***602310
AR09KSWS***660340
AR18/24KSFS***660340
AR30KSFS***690403

Outdoor unit installed on the wall by rack

  • Ensure the wall will be able to suspend the weight of rack and outdoor unit;
    • Install the rack close to the column as much as possible;
    • Install proper grommet in order to help reduce noise and residual vibration transferred by outdoor unit towards wall.

SAMSUNG AR09KSFSAWKNSA - Outdoor unit installed on the wall by rack - 1

text_image Designed to cut off residual vibration from outdoor unit to rack. (not supplied with product) Soft rubber designed to cut off vibration from rack to wall. (not supplied with product)

Smart Install mode

This model supports Smart Install mode which checks installation status to find out if there is any problems with any of the functions. Execute Smart Install mode after installation.

  1. Check the installation status of the air conditioner.

1) Check the power supply, service valve (if it's open), power cable of the indoor and outdoor unit and amount of additional refrigerant required for pipe extension.
2) Status of the indicator after supplying the power: Standby status

  1. When the air conditioner is in standby status, use the remote controller to start the Smart Install mode.

1) Press the Set, Mode and Power ⏻ button simultaneously for 4 seconds.

SAMSUNG AR09KSFSAWKNSA - Smart Install mode - 1

text_image Temp - Mode Fan Timer Options Settings < SET >

* Remote controller may be different (image/functions) depending on the model.

Smart Install mode

2) Smart Install mode in progress

• 88 Display: Progress will be displayed in 0\~99.
- LED Display : Indicator on the indoor unit display will blink in sequence and then all indicators will blink. (This will be repeated.)

TYPE 88 Display LED Display
Indoor unit indicatorSAMSUNG AR09KSFSAWKNSA - Smart Install mode - 1SAMSUNG AR09KSFSAWKNSA - Smart Install mode - 2LED 1LED 2LED 3

* Display may be different depending on the model.

  1. Smart Install mode will end.

1) Smart Install mode will take approximately 7\~13 minutes. (Actual time may be different depending on the model.)
2) When Installation is successful: Smart Install mode will end with ringing sound and the air conditioner will be in standby status. (Error message will not be displayed on the indoor unit indicator and the remote controller and buttons on the indoor unit will work normally.)
3) When installation is not successful: Smart Install mode will end and error message will be displayed on the indoor unit display.

SAMSUNG AR09KSFSAWKNSA - Smart Install mode - 3

  1. Take necessary measures when error occurs.
  2. Refer to the service manual for necessary measures for each error that occurs.
  3. Use the product after taking care of the error that occurs.
Error indicatorError Measures to take by an installer
88DisplayLED Display
LED 1LED 2LED 3
E 101Communication Error between Indoor and outdoor unit (whether the power cable and communication cable is crossed or not)
E 121Error on indoor temperature sensor
E 122,E 123Error on indoor heat exchanger
E 154Error on indoor fan motor
88display and all LED blinksEEPROM/Option error
E 162,E 163
E422Refrigerant flow blocking Error
ESS4Lack of Refrigerant (For Inverter model only)
※ Above LED pattern is displayed when there's error is occurred on outdoor unit. Check the LED display on outdoor unit for the details.

Final check and trial operation

To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly.

Check the followings:

• Strength of the installation site
- Tightness of pipe connection to detect gas leak
• Electric wiring connection
- Heat-resistant insulation of the pipe
- Drainage
• Grounding conductor connection
- Correct operation (follow the steps below)

1. Press the Power button and check the following:

▶ The indicator on the indoor unit lights up.
The airflow blade opens and the fan gears up for operation.
In Cool mode, use Temp + or - button and set the temperature at 16 °C.
In Heat mode, use Temp + or - button and set the temperature at 30 °C.

2. Press the Mode button to select Cool or Heat mode.

SAMSUNG AR09KSFSAWKNSA - Press the Mode button to select Cool or Heat mode. - 1

  • Approximately 3\~5 minutes later, outdoor unit will start to operate and the Cool or Warm air will blow out.
    • After 12 minutes of stationary condition check the indoor unit air treatment.

Cooling mode (indoor unit check) → Inlet air temp. - Outlet air temp: From 10 °C to 12 °C (indicative delta T)

Heating mode (indoor unit check) → Outlet air temp. - Inlet air temp: From 11 °C to 14 °C (indicative delta T)

In heating mode, the indoor fan motor can remain off to avoid cold air blown into conditioned space.

  1. Press the Air swing button and check the following:
    ▶ The airflow blades work properly.

  2. Press the Power button to stop the operation.

SAMSUNG AR09KSFSAWKNSA - Press the Mode button to select Cool or Heat mode. - 2

- When you complete the installation successfully, hand over this manual to the user for storage in a handy and safe place.

SAMSUNG AR09KSFSAWKNSA - Press the Mode button to select Cool or Heat mode. - 3

text_image Power Mode + Torr C= Fan

SAMSUNG AR09KSFSAWKNSA - Press the Mode button to select Cool or Heat mode. - 4

text_image Mode + Temp Fan

SAMSUNG AR09KSFSAWKNSA - Press the Mode button to select Cool or Heat mode. - 5

text_image Power Mode + Temp Fan

Pump down procedure (when removing the product)

  1. Press the Power ⏻ button on the indoor unit for 5 seconds. Beep will sound immediately to let you know that the product is ready for pump down procedure. Please let the compressor run for more than 5 minutes.
  2. Release the valve caps on High and Low pressure side.
  3. Use L wrench to close the valve on the high pressure side.
  4. After approximately 1 minutes, close the valve on the low pressure side.
  5. Stop operation of the air conditioner by pressing the power button on the indoor unit or remote controller.
  6. Disconnect the pipes.

How to connect your extended power cables

Items to prepare

(compressor and insulation tape should be prepared by an installation technician.)

Tools Crimping pliersConnection sleeve (mm)Insulation tapeContraction tube (mm)
SpecMH-14 20x∅7.0(HxOD) Width 18 mm 50x∅8.0(LxOD)
ShapeSAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 1SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 2SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 3SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 4
  1. As shown in the figure, peel off the shields from the rubber/wire of the power cable.

- Peel off 20 mm of the wire shields of the tube installed already.

SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 5

  • For information about the power cable specifications for indoor and outdoor units, refer to the installation manual.
    • After peeling off the tube wire, you must insert a contraction tube.

  • Insert both sides of core wire of the power cable into the connection sleeve.

  • Using a compressor, compress the two points and flip it over and compress another two points in the same location.

- The compression dimension should be 8.0.

- After compressing it, pull both sides of the wire to make sure it is firmly pressed.

  1. Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the insulation tape. A total of three or more layers of insulation is required.
  2. Apply heat to the contraction tube to contract it.
  3. After tube contraction work is completed, wrap it with the insulation tape to finish.

- Make sure that the connection parts are not exposed to outside.

- Be sure to use insulation tape and a contraction tube made of approved reinforced insulating materials that have the same level of withstand voltage with the power cable.(Comply with the local regulations on extensions.)

SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 6

text_image (Unit: mm) Power cable (provided by us) 202020 60 120 180 Wire tube power cable 20

SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 7

text_image Connection sleeve

SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 8

text_image Comp. dim. 8 Compress it 4 times 5 mm

SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 9

text_image Insulation tape 40 mm Contraction tube

SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 10

text_image Insulation tape

SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 11

- In case of extending the electric wire, please DO NOT use a round-shaped pressing socket. - Incomplete wire connections can cause electric shock or a fire.

SAMSUNG AR09KSFSAWKNSA - How to connect your extended power cables - 12

SAMSUNG

QUESTIONS OR COMMENTS?

COUNTRY CALL OR VISIT US ONLINE AT
AUSTRALIA 1300 362 603 www.samsung.com/au/support
NEW ZEALAND 0800 726 786 www.samsung.com/nz/support

Air Conditioner user & installation manual

imagine the possibilities

Thank you for purchasing this Samsung product.

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : SAMSUNG

Model : AR09KSFSAWKNSA

Category : Air-conditioner