USER MANUAL GNPR40L GE
Water Softening system
Safety Information 2
Installation Instructions .....3-15
Step-by-step instructions .....6-15
Operating Instructions
Breaking a salt bridge .....17
Cleaning the injector and screen .....17
Service 16
Water softener system .....16-17
Care and Cleaning 18
Troubleshooting Tips .....19-21
Advanced Programming .....22-23
Advanced Troubleshooting ....24-27
Consumer Support
Checking the Brine Draw and Refill Function....30
Consumer Support ....Back Cover
Control Valve Diagram/Parts .....31, 33
Flow Diagrams .....28-29
Systems Diagram/Parts .....32, 33
Warranty (U.S.) 34
Warranty (Canada) 35
Water Meter 30

text_image
TESTED AND CERTIFIED Water Quality UNDER INDUSTRY STANDARDSWrite the model and serial numbers here:
Model # ____
Serial # ____
To find these numbers, lift the cover and look on the rim below the control panel.
Water Softening System
Owner's Manual & Installation Instructions
Models GNPR40L, GNPR48L

natural_image
Abstract decorative swirl design with no text or symbols215C1173P030 49-50218-1 04-07 JR
▲ WARNING!
For your safety, the information in this manual must be followed to minimize the risk of electric shock, property damage or personal injury.

SAFETY PRECAUTIONS
- Check and comply with your state and local codes. You must follow these guidelines.
■ Use care when handling the water softening system. Do not turn upside down, drop, drag or set on sharp protrusions.
Water softening systems using sodium chloride (salt) for regeneration add sodium to the water. Persons on sodium restricted diets should consider the added sodium as part of their overall intake. Potassium chloride can be used as an alternative to sodium chloride in your softener.
The water softening system works on 12 volt-60 Hz electrical power only. Be sure to use only the included transformer.
■Transformer must be plugged into an indoor 120 volt, grounded outlet only.
Use clean water softening salts only, at least 99.5% pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. These products may contain dirt and sediments, or mush and cake, and will create maintenance problems.
- Keep the brine tank cover in place on the softener unless servicing the unit or refilling with salt.
⚠ WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

PROPER INSTALLATION
This water softening system must be properly installed and located in accordance with the Installation Instructions before it is used.
■ Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather. Water freezing in the system will break it.
Do not install in direct sunlight. Excessive sun or heat may cause distortion or other damage to non-metallic parts. Do not attempt to treat water over 100°F.
■Properly ground the system to conform with all governing codes and ordinances.
■ Use only lead-free solder and flux for all sweat-solder connections, as required by state and federal codes.
The water softening system requires a minimum water flow of three gallons per minute at the inlet. Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve to reduce the flow if necessary.
■ Softener resins may degrade in the presence of chlorine above 2 ppm. If you have chlorine in excess of this amount, you may experience reduced life of the resin. In these conditions, you may wish to consider purchasing a GE point-of-entry household filtration system with a chlorine reducing filter.
⚠ WARNING: Discard all unused parts and packaging material after installation. Small parts remaining after the installation could be a choke hazard.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
Installation Instructions
Water Softening System
Models GNPR40L and GNPR48L

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com

WARNING: Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage.
- Check with your state and/or local public works department for plumbing codes. You must follow their guides as you install the Water Softening system.
NOTE: Failure to comply with these installation instructions will void the product warranty, and the installer will be responsible for any service, repair or damages caused thereby.
BEFORE BEGINNING INSTALLATION
Read these instructions completely and carefully.
- IMPORTANT — Save these instructions for local inspector's use.
- IMPORTANT – Observe all governing codes and ordinances.
- Note to Installer – Be sure to leave these instructions with the Consumer.
- Note to Consumer – Keep these instructions for future reference.
- Proper installation is the responsibility of the installer.
- Product failure due to improper installation is not covered under the Warranty.
IMPORTANT INSTALLATION RECOMMENDATIONS(CONT.)
▲WARNING:
Do not use with water
that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. The water should be tested periodically to verify that the system is performing satisfactorily.
IMPORTANT INSTALLATION RECOMMENDATIONS
- In the Commonwealth of Massachusetts, Plumbing Code 248 CMR shall be adhered to. Consult with your licensed plumber.
- Use only lead-free solder and flux for all sweat-solder connections, as required by state and federal codes.
- Connect the softener to the main water supply pipe before or ahead of the water heater. DO NOT RUN HOT WATER THROUGH THE SOFTENER. Temperature of water passing through the softener must be less than 100°F.
UNPACKING AND INSPECTION
Be sure to check the entire softener for any shipping damage or missing parts. Also note damage to the shipping cartons. Contact the transportation company for all damage and loss claims. The manufacturer is not responsible for damages in transit.
Small parts needed to install the softener are packaged either in a bag or box. To avoid loss of the small parts, keep them packaged until you are ready to use them. Be sure not to discard components hidden in packaging.
TOOLS AND MATERIALS REQUIRED FOR INSTALLATION
- Teflon tape
- Razor knife
• One adjustable wrench - 1/2"vinyl/pvc drain line (the length required will be determined by your specific location)
• Additional tools may be required if modification to home plumbing is necessary. - In and out fittings included with the softener are 1" copper adapters. You should maintain the same, or larger, pipe size as the water supply pipe, up to the softener inlet and outlet. Then, use the necessary adapters to connect the water supply to the 1" copper adapters.
- Use the included bypass valve to install the softener. The bypass valve allows you to turn off water to the softener for servicing, but still have water pressure in the house pipes.
- Use appropriate fitting/pipe material (i.e., copper, brass, galvanized or CPVC) to connect the 1" copper adapters to the house plumbing.
- If a rigid valve drain is needed to comply with plumbing codes, you can buy the parts needed to connect a 1/2" copper tubing or plastic pipe drain.
- Clean nugget or pellet water softener salt is needed to fill the brine tank.
WHERE TO INSTALL THE SOFTENER
- Place the softener as close as possible to a sewer drain, or other acceptable drain point or standpipe.
- It is recommended to keep outside faucets on hard water to save soft water and salt.
- Do not install the softener in a place where it could freeze. Freeze damage is not covered by the warranty.
- Do not install the softener where it would block access to the water heater or access to the main water shutoff.
- Put the softener in a place where water damage is least likely to occur if a leak develops. The manufacturer will not repair or pay for water damage.
- A 120-volt electric outlet is needed to plug in the included transformer. The softener has a 10-foot power cable. If the outlet is remote (up to 100 feet), use 18 gauge wire to connect. Be sure the electric outlet and transformer are in an inside location, to protect from wet weather. Be sure the outlet is unswitched to prevent accidental shutoff.
- If installing in an outside location, you must take the steps necessary to assure the softener, installation plumbing, wiring, etc., are as well protected from the elements (sunlight, rain, wind, heat, cold), contamination, vandalism, etc., as when installed indoors. Outdoor installation is not recommended, and voids the warranty.
- Keep the softener out of direct sunlight. The sun's heat may distort non-metallic parts and may damage the electronics.
PLAN HOW YOU WILL INSTALL THE SOFTENER
You must first decide how to run the inlet and outlet pipes to the softener. Look at the house main water pipe at the point where you will connect the softener. Is the pipe soldered copper, glued plastic or threaded galvanized? What is the pipe size?
⚠ WARNING: Use only lead-free solder and flux to prevent lead poisoning.
See Typical Installation Illustration. Use this as a guide when planning your particular installation. Be sure to direct the incoming hard water supply to the softener valve inlet fitting. The valve is marked IN and OUT.
TYPICAL INSTALLATION ILLUSTRATION

text_image
Hard water Hard water to outside faucets 12V transformer 120-volt outlet MAIN WATER PIPE Soft water Pipe coupler Union nut Adapter OUTLET Brine line SALT GOES HERE Brinewell Brine tank cover NOTE: See Drain Hose Connections section.
text_image
Fig. 1 CROSSOVER Use if water supply flows from the left. Include single or 3-valve bypass. Soft water Hard water To softener inlet From softener outletOPTIONAL 3-VALVE BYPASS INSTALLATION ILLUSTRATION

text_image
Hard water to outside faucets Hard water MAIN WATER PIPE Soft water 12V transformer 120-volt outlet Bypass valve Inlet valve Outlet valve Pipe coupler Union nut Adapter Brine line OUTLET SALT GOES HERE Brinewell Brine tank cover 3-Valve Bypass System For soft water service:
text_image
Fig. 2 CROSSOVER Use if water supply flows from the left. Include single or 3-valve bypass. Soft water Hard water To softener inlet From softener outletBEFORE YOU BEGIN
- Turn off the gas or electric supply to the water heater, in the possibility that the water heater may be drained while draining pipes.
- Turn off the water supply to pipes to be cut and drain the house water pipes.
- Open both hot and cold faucets at the lowest location possible.
1 INSTALL BYPASS VALVE
- Make sure there is a gasket secured inside the inlet and outlet union nuts of the bypass. Then assemble the union nut to the valve inlet and outlet, hand-tightening both union nuts simultaneously. It is not necessary to lubricate or use sealant on the rubber gaskets or union nuts.

text_image
Bypass valve Outlet union nut Valve outlet Valve inlet Gaskets Outlet Inlet Inlet union nut- Insert copper adapters through union nuts. Place the rubber gaskets into the union nuts and assemble to bypass valve. It is not necessary to lubricate or use sealant on rubber gasket or union nuts.

text_image
union nuts. Valve outlet Valve inlet Inlet Copper adapters Outlet Gasket Union nut Copper adapters Outlet Inlet Union nut Valve outlet Valve inletOPERATION
To bypass the Water Softener with the bypass valve, rotate the handles clockwise so they are both perpendicular to the flow path of the inlet and outlet water stream, as shown below.

natural_image
Technical line drawing of a mechanical assembly with two circular components and mounting brackets (no text or symbols)To return to the conditioned water or service position, rotate the handles counterclockwise so they are parallel to the flow path of the inlet and outlet water stream, as shown below.

natural_image
Technical line drawing of a mechanical assembly with two circular components and a central shaft (no text or symbols)2 MOVE THE SOFTENER ASSEMBLY INTO INSTALLATION POSITION
Before sliding softener in position, be sure the installation surface is level and smooth. Sharp objects under the tank may puncture it. If needed, place the tank on a section of 3/4"thick (minimum) plywood. Then, place shims under the plywood as needed to level the softener. Slide softener into position.
3 PLUMB "IN" AND "OUT" PIPES TO AND FROM SOFTENER
⚠️CAUTION: Observe all of the following cautions as you connect inlet and outlet plumbing. See Typical Installation Illustration.
- BE SURE INCOMING HARD WATER SUPPLY IS DIRECTED TO THE SOFTENER VALVE INLET PORT. If house water flow is from the right, use a plumbing crossover as shown in Typical Installation Illustration.
- With the softener in place, determine the correct length of piping required to connect the household plumbing to the 1"copper adapter on the softener. Test fit all connections.
NOTE: The softener must not support the home's plumbing in the vertical direction. Secure the inlet and outlet pipes to the wall/ceiling using pipe clamps or straps. Be certain the home's plumbing does not exert any force on the softener bypass.
- Remove softener from installation space.
- Disconnect copper adapters and union nuts from bypass valve.
- Reconnect copper adapters with union nuts and gaskets in place to home plumbing. Before soldering adapters, slide union nuts and gasket away from area being soldered. NOTE: Torch heat will damage plastic parts.
- Support inlet and outlet plumbing in some manner (use pipe hangers or clamps) to keep the weight off of the valve fittings.
- Slide softener back into position.
- Make final connections to the bypass valve.
4 CONNECT AND RUN THE VALVE DRAIN HOSE
- Check that drain port on valve body has white tape on it. If not, apply Teflon Tape to threads prior to installing the valve drain fitting.
- Connect valve drain fitting to valve drain port. Tighten connection with a wrench.
- Connect 1/2" diameter drain hose (not provided) to the valve drain fitting. Tighten connections with wrench.
Valve drain hose connection

text_image
ction4 CONNECT AND RUN THE VALVE DRAIN HOSE (CONT.)
- Locate the other end of the hose at a suitable drain point (floor drain, sump, laundry tub, etc.) that terminates at the sewer. Check and comply with local codes.
- Tie or wire the hose in place at the drain point. High water pressure will cause it to whip during the back-wash and fast rinse cycles of regeneration. Also provide an air gap of at least 1-1/2" between the end of the hose and the drain point. An air gap prevents possible siphoning of sewer water into the softener, if the sewer should "back-up."
The water softener will not work if water cannot exit this hose during regeneration.
- Elevating the drain hose may cause back pressure that could reduce the brine draw during regeneration. If raising the drain line overhead is required to get to the drain point, measure the inlet water pressure to the softener first. For inlet pressures between 20 and 50 psi, do not raise higher than 8' above the floor. For inlet pressure above 50 psi, the drain line may be raised to a maximum height of 14'.

text_image
Valve drain hose Tie or wire hose in place 1½" air gap 1½" air gap STANDPIPE LAUNDRY TUB 1½" air gap SUMPFLOOR DRAIN
5 INSTALL THE BRINE TANK OVERFLOW AND HOSE
- Connect overflow drain hose to fitting on side of brine tank.
- Locate the other end of the hose at the drain point. DO NOT ELEVATE this hose higher than the elbow on the brine tank.
IMPORTANT: DO NOT TEE OVERFLOW HOSE TO VALVE DRAIN HOSE.
NOTE: This drain is for safety only. If the cabinet (brine tank) should over-fill with water, the excess is carried to the drain.

text_image
Hose adapter Do not connect to valve drain hose. Overflow drain hose To acceptable drain7 INSTALL GROUNDING WIRE AND CLAMPS
IMPORTANT: A copper or galvanized house cold water pipe is often used to ground electrical outlets in the home. Grounding protects you from electrical shock. The water softener may have broken this ground path. To restore connection, install UL approved grounding hardware or 6-gauge copper wire across the softener valve, tightly clamped, using UL approved grounding clamps at both ends as shown. Zinc clamps should not be used on copper plumbing. Grounding hardware is not provided with the unit. It may be purchased separately from your local hardware store.
NOTE: Clean copper pipe and ends of wire with emery paper. Bare wire is recommended. If insulated wire is used, it should be stripped 3/4" at each end before cleaning with emery paper.

text_image
To valve inlet Ground Clamp From valve outlet6 BRINE TUBING CONNECTION
Connect brine tube to clear air check assembly on the main valve:

text_image
Valve assembly Brine tube connection Brine tubing- Route brine tube through 1"hole in brine tank above hose adapter.
- Connect tubing to 90^ fitting on top of float assembly. Press in firmly to fully seat in fitting.

text_image
Brine tube connection To valve assembly Float assembly Brine tubeSTART-UP RINSING PROCEDURE
(BYPASS VALVE IS OPTIONAL)
1 OPEN WATER SUPPLY
With the plumbing, drain line and overflow connections completed, slowly open the water supply, allowing the lines to pressurize.
NOTE: The optional bypass should still be in bypass mode as shown.

natural_image
Technical line drawing of a mechanical device with two circular components and mounting brackets (no text or symbols)Outlet
Inlet
2 ADVANCE THE CONTROL VALVE
With the transformer unplugged, manually advance the control valve by depressing the drive gear and rotating the main system gear to the purge position (see Step 4).

text_image
SERVICE PURGE3 PURGE THE SYSTEM
Slowly open the inlet valve (only) on the bypass valve to the half-opened position, allowing the system to pressurize. It is normal to hear air blowing to the drain during this procedure.
Once the air clears and water begins to run to the drain, open the inlet valve (only) to the full open position and allow the water to run to the drain in purge for a minimum of 20 minutes.

natural_image
Technical line drawing of a mechanical assembly with two circular components and a handle (no text or symbols)Outlet
Inlet
4 RUN THE WATER
After the 20-minute purge cycle, manually advance the main gear to the backwash cycle and allow to run for a minimum of 10 minutes.
After 10 minutes during the backwash cycle, open both the inlet and outlet valves on the bypass to the fully opened position.
NOTE: When advancing the main gear manually while under water pressure, it is normal for the gear to encounter resistance as the valve chambers depressurize. If resistance occurs, pause five seconds to allow the valve to depressurize before advancing to the next step.

natural_image
Mechanical assembly diagram showing hands operating a gear mechanism with a wrench (no text or symbols present)Advance the gear in the counterclockwise direction only. Damage will occur if advanced in the opposite direction.
5 FILL BRINE TANK
After the ten-minute backwash cycle, manually advance the control valve to the brine refill position for ten minutes, allowing water to flow into the brine storage tank.

text_image
REFILL SERVOnce water begins to flow into the tank, fill the brine tank with a minimum of 80 lbs. of salt pellets.
6 ADVANCE CONTROL VALVE TO SERVICE POSITION
After the ten-minute refill time, manually advance the control valve to the service position.

text_image
RILL SERVICE7 CONNECT TO ELECTRICAL POWER
- The softener works on 12 volt-60Hz electric power. The included transformer changes standard 120-volt AC house power to 12 volts DC. Connect transformer to control panel. Plug is located on the bottom left of the control panel. Plug the transformer into a 120-volt outlet only. Be sure the outlet is always live so it can not be switched off by mistake.

text_image
12:00 Connect transformer to control panel
8 INSTALL 9V BATTERY FOR BATTERY BACKUP FEATURE
Your softening system has a battery backup feature that allows the control to continue monitoring water flow and maintain the proper time of day during short power outages. The control uses a standard 9-volt battery (not supplied).
During a power outage, the display will be turned off and the motor will not run, but the control will continue to monitor water flow and time. If power is out and a regeneration is needed, the regeneration will be delayed until power is restored. If power is lost during the regeneration, the control will resume the regeneration when power is restored.
While batteries may last for over a year, it is recommended that you replace the battery every year.

natural_image
Technical line drawing of a mechanical assembly with gears and housing (no text or symbols)During an interruption in power supply, a typical new 9-volt alkaline battery provides approximately 40 hours of power for the control.
If there is a power outage, after power is restored, verify that the time in the control is correct. If it is, system is OK. If time is incorrect, set the correct time in the control and replace the 9-volt battery. If system has been without power for over 24 hours, initiate an immediate regeneration cycle by pressing the REGEN button.
8 INSTALL 9V BATTERY FOR BATTERY BACKUP FEATURE (CONT.)
To install a battery:
- Remove the control valve cover.
- The battery pocket is located in the upper left corner of the control as shown.
- Connect the battery, matching up negative and positive posts.
- Insert battery into holder located on the back of the control panel. Make sure terminal wires are routed away from the valve gears.
9 INJECTOR SELECTION
- The injector is critical to the proper flow through the resin tank during the regeneration cycle. The injector supplied with the unit from the factory is applicable to installations with supply water pressure up to 70 psi.
- If supply water pressure is greater than 70 psi, injector assembly WS15X10059 should be installed.
| Water Pressure Injector Part Number | |
| 20–70 psi 5 bumps | WS15X10060 |
| 70–125 psi 4 bumps | WS15X10059 |

text_image
Injector Injector capPROGRAMMING THE CONTROL
PROGRAMMING THE CONTROL

The green indicator lights up next to the name of the active control setting.
Pressing the DOWN ▼ button displays the settings in order. By continuing to press the DOWN ▼ button, the settings start over, beginning with the time of day. Pressing the UP ▲ button displays the settings in reverse order.
To change the settings, press the SET button on the top right. A digit on the display will start to flash. If you want to change this number, press the UP ▲ button to increase the number or the DOWN ▼ button to decrease the number.
When the number is correct, press the LEFT button. The digit to the right will stop flashing and the next digit to the left starts flashing.
To skip the number without changing, press the LEFT button. When you reach the far left digit, press the LEFT button to return to the digit on the right.
NOTE: If you press and hold either the UP or DOWN button for more than 1 second, the flashing number will increase or decrease at ten counts per second.
You can only change the flashing digit. Continue changing numbers until you reach the desired setting. Press the SET button. The numbers stop flashing and the control accepts the new settings. After approximately 30 seconds, the control starts alternating the display between TIME OF DAY and CAPACITY.
NOTE: If the new setting is not accepted because it was outside the allowable range, the old value will be displayed. Refer to the table guides for correct settings.
SET PRESENT TIME OF DAY

- Press the SET button. The display will show the time of day with the minutes blinking.
- Press UP ▲ DOWN button to set. The UP button advances the digit; the DOWN button moves the digit in reverse.
When the number is correct, press the LEFT button. The digit to the right will stop flashing and the next digit to the left starts flashing. You can only change the flashing number.
If the present time is between noon and midnight, be sure PM indicator light is on. If the present time is between midnight and noon, be sure PM indicator light is off.
To change AM/PM, advance the far left digit. The digit will alternate between 0 and 1. As the digit alternates, the PM light will turn on and off.
NOTE: Each press of an UP ▲ DOWN button changes the digit by one minute. Holding the button changes the digit at a rapid rate.
- When the present time is correct, press SET to accept.
TIME OF REGENERATION
The system has a default setting of 2:00 a.m.
To change:
- Use the UP ▲ DOWN button to select a new time for regeneration.
- Use procedure in SET PRESENT TIME OF DAY.
- Press the SET button to accept.
TOTAL WATER HARDNESS
Water hardness is the hardness of the supply water to the house in grains per gallon. The system has a default setting of 25 grains/gallon.
A water test should be performed at the time of installation to determine your water hardness (grains/gallon). You can get the grains per gallon (gpg) hardness of your water supply from a water analysis laboratory. If you are on a municipal supply, call your local water department. If your report shows hardness in parts per million (ppm), simply divide by 17.1 to get the equivalent number of grains per gallon.
To change:
- Use the UP ▲ DOWN button to select total water hardness.
- Press the SET button.
- Change the digits by using the UP ▲DOWN ▼ or LEFT button.
- Press the SET button to accept.
SALT PER REGEN AND CAPACITY
These two settings are required to provide the most efficient operation of the system in your installation.
Salt efficiency is improved by regenerating part of the capacity. For example, the GNPR40 has 37,100 grains of capacity. It is more efficient to regenerate 20,000 grains of capacity more frequently than waiting and regenerating the complete 37,100 grains.

line
| Capacity (1,000 grains) | Salt Setting (lbs) | | ------------------------ | ------------------ | | 0 | 3 | | 1 | 5 | | 2 | 15 |
line
| Capacity (1,000 grains) | Salt Setting (lbs) | | ----------------------- | ------------------ | | 1 | 3 | | 0 | 10 | | 2 | 15 | | 0 | 25 |Both SALT PER REGEN and CAPACITY are determined based on the chart on page 13.
FOR CALIFORNIA INSTALLATIONS:
- California regulations require the control setting to yield 4,000 grains of capacity per pound of salt. To meet these requirements, the SALT PER REGEN and CAPACITY must be set no higher than indicated below:
| Model Capacity Default Salt Default | ||
| GNPR40L 16.5 | <Gr 4.0 lbs | |
| GNPR48L 15.2 | <Gr 3.6 lbs | |
SALT PER REGEN AND CAPACITY (CONT.)
NOTE: Both SALT PER REGEN and CAPACITY inputs must be based on the SYSTEM CAPACITY INPUTS CHART.
How to determine correct salt dosage and capacity:
The correct salt dosage and capacity are determined based on the family size and water hardness. Use the following procedure and example:
- Daily Water Usage = number of persons in household × 80 gallons
For a family of 3 Daily Water Usage = 3 × 80 = 240 gallons/day - Water Hardness – have the water tested or call your local water company. For this example, 20 grains is assumed.
- Calculate total grains used per day = gallons/day × hardness = grains/day 240 gallons/day × 20 grains = 4,800 grains/day
- Water softener should be set to regenerate every 5 days.
Req Capacity = 5 days × 4,800 grains/day = 24,000
- Use SYSTEM CAPACITY INPUT table to select capacity and determine lbs of salt per regeneration.
For GNPR40 use setting at 24,000 grains.
- Program the control:
Capacity: 24,000 grains
Lbs of Salt: 7.0
If water supply has a high level of sediment or iron, set system to regenerate every 3 days:
- Use the UP ▲ DOWN button to select SALT PER REGEN.
- Press the SET button.
- Use the UP ▲DOWN and LEFT buttons to select SALT PER REGEN amount.
- Press the SET button to accept.
- Use the UP ▲ DOWN button to select CAPACITY.
- Press the SET button.
- Use the UP ▲DOWN and LEFT buttons to select correct capacity.
- Press the SET button to accept.
SYSTEM CAPACITY INPUTS
| Example of Lbs of Salt req. per regen | CAPACITY (x 1,000) | |
| GNPR40L GNPR48L | ||
| 3.0 14.1 | 40 | N/A |
| 3.6 15.5 | 15.2 | 48 |
| 4.0 16.5 | 15.5 | |
| 5.0 19.0 | 18.0 | |
| 6.0 22.0 | 21.0 | |
| 7.0 24.0 | 23.5 | |
| 7.5 24.4 | 40 | 24.3 |
| 8.0 25.6 | 25.0 | |
| 9.0 27.9 | 26.1 | 48 |
| 10.0 30.0 | 30.0 | |
| 11.0 31.9 | 31.5 | |
| 12.0 33.6 | 33.0 | |
| 13.0 35.1 | 34.0 | |
| 14.0 36.4 | 35.2 | |
| 15.0 | 37.1^40 | 36.0 |
| 16.0 | N/A | 37.0 |
| 17.0 | N/A | 38.0 |
| 18.0 | N/A | 39.8 |
| 19.0 | N/A | 41.0 |
| 20.0 | N/A | 41.5 |
| 21.0 | N/A | 42.0 |
| 22.0 | N/A | 43.0 |
| 23.0 | N/A | 44.0 |
| 24.0 | N/A | 45.2 |
| 25.0 | N/A | 45.9 |
| 26.0 | N/A | 46.5 |
| 27.0 | N/A | 47.2 |
| 28.0 | N/A | 48.9^48 |
^40 GNPR40L certified capacity at salt setting
^48 GNPR48L certified capacity at salt setting
NOTE: The 3.0 lbs salt setting (GNPR40L) and the 3.6 lbs salt setting (GNPR48L) are certified using the 5 bump injector. The 7.5 lbs (GNPR40L), 15 lbs (GNPR40L), 9 lbs (GNPR48L) and 18 lbs (GNPR48L) are certified using the 4 bump injector.
NORMAL OPERATION
The control will cycle between TIME OF DAY and CAPACITY about every 10 seconds, as indicated by the green indicator light.
Capacity in Normal Operation mode is the gallons of water available until the next regeneration cycle.
During a regeneration cycle, the control will cycle between TIME OF DAY and REGEN TIME REMAINING.
REGEN TIME REMAINING is the number of minutes until the regeneration cycle is complete.
MANUAL REGENERATION
Occasionally you may find it necessary to initiate a manual regeneration. This is done by pressing the REGEN button on the front of the display. When you press the REGEN button, the control performs a full regeneration of the water conditioner immediately.
In the event the system is allowed to run out of salt, it will be necessary to run "Back to Back" regenerations. This can be done easily by pressing the REGEN button one time, waiting at least one minute and pressing the REGEN button again.
NOTE: The second regeneration will begin immediately after the first is completed.
"Back to Back" regenerations are necessary if full exhaustion occurs due to low regenerate levels or system malfunction. The system works on a highly efficient proportionate-brining method. When the system is not aware of the lack of proper regenerate (salt), a larger portion of the resin bed becomes exhausted.

This system continuously monitors itself and displays an error message if it detects something wrong. This typically happens when the valve has not advanced through the regeneration cycle properly.
When an error is detected, the display shows the letters "Err" with a number from 1 to 4. The table on page 24 describes each error, the cause of the error and the solutions.
To clear the error from the display, press any button on the control. If the error still exists, the control will display the error message again after 30 seconds.
SOUNDS YOU WILL HEAR
During the regeneration cycle, the softener makes several sounds. These sounds are normal.
- Clicking sound – This occurs as the valve assembly advances. It is the opening and closing of the valve ports.
- Harmonic sound – As the valve transitions between cycles in regeneration, a high-pitched harmonic noise may be heard for a few seconds.
- Water flow sound – In the backwash and purge portions of the regeneration, water flow is very high – 2–3 gpm. This is required to flush the tank of accumulated minerals and sediments.
SANITIZING PROCEDURES
To complete the installation, do the following sanitizing procedures.
Care is taken at the factory to keep your water softener clean and sanitary. Materials used to make the softener will not infect or contaminate your water supply and will not cause bacteria to form or grow. However, during shipping, storage, installation and operation, bacteria could get into the softener. For this reason, sanitizing as follows is suggested when installing.
NOTE: Sanitizing is recommended by the Water Quality Association for disinfecting.
- Be sure to complete all installation steps, including programming the control.
- Pour about 3/4 oz. (1 ½ tablespoons) of common 5.25% unscented household bleach (Clorox, Linco, Bo Peep, White Sail, Eagle, etc.) into the brinewell. Refer to illustration on page 5.
-
IMPORTANT: Press and hold for 3 seconds the faceplate REGEN button to start an immediate regeneration. The indicator light will alternate between TIME OF DAY and REGEN TIME REMAINING. The bleach will be drawn through the water softener, and out the drain. This process takes approximately 3 hours.
-
If, after sanitization, water from the house faucet tastes salty or has a slight color, this is a preservative from the resin tank. Turn on the cold soft water faucets and drain for a few minutes or until clear.
NOTE: When the sanitizing regeneration is over, all remaining bleach is flushed from the conditioner and your house COLD water supply is fully soft immediately. However, your water heater is filled with hard water and as hot water is used, it will refill with soft water. When all the hard water is replaced in the water heater, hot only and mixed hot and cold water will be fully soft. If you want totally soft water immediately, after the above regeneration, drain the water heater until the water runs cold.
⚠ WARNING: If you do drain the water heater, use extreme care as the hot water could cause burns. Turn the water heater off prior to draining.
| SPECIFICATIONS/DIMENSIONS | GNPR40L GNPR48L | ||
| Resin Tank Size 10x44"12x48" | |||
| Resin Volume 1.25 ft | 3 | 1.50 ft3 | |
| Refill Controller 0.35 gpm 0.35 gpm | |||
| Backwash Controller 2.8 gpm | 2.8 gpm | ||
| Brine Tank | Size | 15x40" | 15x40" |
| Capacity | 350 lbs 350 lbs | ||
| Operation Temperature | Min. | 34° | 34° |
| Max. | 100°F | 100°F | |
| Flow Rate | 15.2 gpm 18.0 gpm | ||
| Pressure Drop | 15.0 psi | 15.0 psi | |
| Maximum Flow to Drain | 4.0 gpm | 3.5 gpm | |
These systems conform to WQA NSF/ANSI 44 for the specific capacity claims as verified and substantiated by test data.
* Testing was performed using pellet grade sodium chloride as the regenerant salt.
** Efficiency rating is valid only at the lowest stated salt dosage. These softeners were efficiency rated according to WQA NSF/ANSI 44.
*** Extent of iron removal may vary with conditions. The capacity to reduce clear water iron is substantiated by WQA test data. State of Wisconsin requires additional treatment if water supply contains greater than 5 ppm clear water iron. Use of Diamond Crystal® Red•Out® or Super Iron Out® will improve iron removal. Refer to Cleaning Iron Out of the Water Softening System section.

text_image
40¼" 15" 14½" 50" 44 47" 10"
text_image
40¼" 15" 54¼" 48 12" 15¼" 51¼"About the water softener system.
Service
When the water softening system is providing soft water, it is called "Service." During service, hard water flows from the house main water pipe into the water softening system. Inside the water softening system resin tank is a bed made up of thousands of tiny, plastic resin beads. As hard water passes through the bed, each bead attracts and holds the hard minerals. This is called ion-exchanging. It is much like a magnet attracting and holding metals. Water without hard minerals (soft water) flows from the water softening system and to the house pipes.
After a period of time, the resin beads become coated with hard minerals and they have to be cleaned. This cleaning is called regeneration. The regeneration cycle is started at 2:00 AM (factory setting) by the water softening system control, and consists of five stages or cycles. These are FILL, BRINING, BRINE RINSE, BACKWASH and FAST RINSE.
Automatic Hard Water Bypass During Regeneration
For emergency needs, hard water is available to the home during the regeneration cycles.
However, you should avoid using HOT water because the water heater will fill with the hard water.
Fill
Salt dissolved in water is called brine. Brine is needed to clean the hard minerals from resin beads. To make the brine, water flows into the salt storage area during the fill stage.
Backwash
During backwash, water travels up through the resin tank at a fast flow rate, flushing accumulated iron, dirt and sediments from the resin bed and to the drain.
Brining
During brining, brine travels from the salt storage area into the resin tank. Brine is the cleaning agent needed to remove hard minerals from the resin beads. The hard minerals and brine are discharged to the drain.
Fast Rinse
Backwash is followed by a fast flow of water down through the resin tank. The fast flow flushes brine from the bottom of the tank, and packs the resin bed.
The nozzle and venturi create a suction to move the brine, maintaining a very slow rate to get the best resin cleaning with the least salt.
After fast rinse, the water softening system returns to soft water service.
Brine Rinse
After a pre-measured amount of brine is used, the brine valve closes. Water continues to flow in the same path as during brining, except for the discontinued brine flow. Hard minerals and brine flush from the resin tank to the drain.
Breaking a Salt Bridge
Sometimes, a hard crust or salt bridge forms in the salt storage area. It is usually caused by high humidity or the wrong kind of salt. When the salt bridges, an empty space forms between the water and salt. Then salt will not dissolve in the water to make brine.
If the brine tank is full of salt, it is hard to tell if you have a salt bridge. Salt is loose on top, but the bridge is under it. The following is the best way to check for a salt bridge.
Salt should be loose all the way to the bottom of the tank. Take a broom handle or like tool, and carefully push it down into the salt, working it up and down. If the tool strikes a hard object (be sure it's not the bottom or sides of the tank), it's most likely a salt bridge. Carefully break the bridge with the tool. Do not pound on the walls of the tank.
If the wrong kind of salt made the bridge, take it out. Then fill the tank with nugget or pellet salt only. In humid areas, it is best to fill with less salt, more often to prevent a salt bridge from forming.

text_image
Push tool into salt bridge to break 1"-2" Pencil mark Broom handle Salt Salt bridge Water levelCleaning the Injector and Screen
A clean injector and screen is needed for the water softening system to work properly. This small unit makes the suction to move brine from the brine tank storage area to the resin tank during regeneration. If it becomes plugged with sand, dirt, etc., the water softening system will not work and you will get hard water. This will be evident by a high level of water in the brine tank—over 4" when the system is in service mode.
TO CLEAN:
- Put system in Bypass mode and relieve water pressure.
- Remove injector screen (a flat-head screwdriver is required).
- Remove injector cap and injector (needle nose pliers are required).
- Clean and flush thoroughly.
- Check for damage.
•Reassemble injector and injector screen.
• To check proper operation, see page 30, Checking the Brine Draw and Refill Function. - Initiate REGEN cycle to restore resin bed. A back-to-back regeneration is suggested. Excess water in the brine tank will be removed.

text_image
Injector Injector cap Injector screenInjector screen and cap installation
Checking the Salt Storage Level and Refilling
Brine (salt dissolved in water) is needed for each and every regeneration. The water for making brine is metered into the salt storage area by the water softening system valve and control. However, you must keep the tank supplied with salt.
Use clean water softening salts only, at least 99.5% pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. They contain dirt and sediments, or mush and cake, and will create maintenance problems.
⚠️CAUTION: Water softening salt with iron removing additives: Some salts may have an additive to help the water softening system handle iron in the water supply. Although this additive may help to keep the water softening system resin clean, it may also release corrosive fumes that weaken and shorten the life of some water softening system parts. GE recommends using only Diamond Crystal® Red•Out® brand salt.
Cleaning Iron Out of the Water Softening System
Your water softening system takes hardness minerals (calcium and magnesium) out of the water. Also, it can control some (see the Specification Guidelines section) "clear water" iron. With clear water iron, water from a faucet is clear when first put into a glass. After 15 to 30 minutes, the water begins to cloud or turn rust colored. A water softening system will not remove any iron that makes the water cloudy or rusty as it comes from the faucet (called red water iron). To take red water iron out of water, or over the maximum of clear water iron, an iron filter or other equipment is needed.
GE recommends using only Diamond Crystal® Red•Out® brand salts with Iron Fighter® additive to help keep the resin bed clean of clear iron. If your water supply has clear water iron, periodic resin bed cleaning is needed. GE recommends using Super Iron Out® brand resin bed cleaner to thoroughly clean your resin bed if your iron content is high. Clean the bed at least every six months, or more often if iron appears in the soft water between cleanings.
IMPORTANT: It is important to mix the resin bed cleaner with water (following the manufacturer's instructions), pour it into the brinewell tube (see page 5) and regenerate the softener immediately. Do not pour the resin bed cleaner in with the salt, as it will not be as effective in cleaning the resin, and can cause damage to the softener if it is left in the brine tank for an extended period due to the corrosive gases that are formed.
The control has an adjustable backwash cycle. The backwash can be lengthened to better flush the resin bed from high sediment or iron situations. See the Advanced Control Setting section or consult an installer.
Also set LBS OF SALT and CAPACITY so the system will regenerate about every 3 days. See page 13.

Troubleshooting Tips
Save time and money! Review the chart on these pages first and you may not need to call for service.
NO SOFT WATER – Most Common Problems:
Check the following before calling for service:
- Not enough salt—brine tank should be at least 1/3 full.
- Bypass valve in "Bypass" position—flange on knobs should be in line with pipes (see page 6).
- Hardness setting too low. Check hardness setting and adjust. Verify hardness of supply water—from local water company, water test or call the GE Answer Center.
- Salt Bridge—salt solidifies above water level so that brine water is not in contact with salt. See the Breaking a Salt Bridge section.
Problem Possible Causes What To Do
| No soft water Faucet or fixture where sample was• taken not plumbed to soft water. NOTE: Be sure sample is from a faucet of the water softening system, trace the water flow path, that does not mix soft and hard water. For example, a single lever kitchen faucet, or if the cold side is plumbed to hard water. | To conserve salt, the installer may have isolated some fixtures (outside faucets, toilets, etc.) from soft water. From the outlet water softening system, trace the water flow path, in house plumbing. If soft water is not directed to a faucet fixture where wanted, consult a plumber. |
| No salt in the brine tank or• Check for a salt bridge or, if the tank is empty, refill with salt bridged recommended salt. Press (for 3 seconds) the REGEN button to start an immediate regeneration and restore soft water supply. See page 17, Breaking a Salt Bridge. | |
| Transformer unplugged at wall outlet or power cable to softener not connected. Fuse blown or circuit breaker popped on circuit to electrical outlet. Electrical outlet on a circuit that can continuously be switched off | • Check for a loss of electrical power to the water softening system, due to any of these conditions and correct as needed. With the power supply restored, observe the faceplate time display and read Programming the Control section. NOTE: The electrical outlet for the softener should be live so it cannot be accidentally switched off. |
| Manual bypass valve in bypass position | • Be sure the flange on the bypass valve knobs are in line with the pipes. |
| Valve drain hose pinched, plugged, elevated too high or otherwise restricted | • Any restriction in this drain hose may prevent proper operation of the nozzle and venturi and reduce or prevent brine draw during regeneration. |
| Injector and injector screen dirty, incorrectly assembled or damaged | • This will be evident by a high level of water in the brine tank. Water level will be greater than 4" when the system is in the service position. • Refer to Cleaning the Injector and Screen instructions. With water pressure to the water softening system off, remove the injector and injector screen. Thoroughly clean and flush. Check for any damage. Reassemble to valve assembly. |
| If resin bed is fully exhausted, for example, after a malfunction, one regeneration cycle may not fully restore capacity | • Complete "back to back" regenerations. Initiate Regeneration cycle, wait 1 minute, then press REGEN again. See page 14. |

Troubleshooting Tips
| Problem Possible Causes What To Do | ||
| Water hard sometimes | Using hot water while the water softening system is regenerating | · Avoid using hot water during water softening system regeneration because the water heater will refill with hard water. |
| Control HARDNESS number setting too low number shown is the same as the actual grains per gallon hardness of your water supply. See the Programming the Control section if a change in the setting is needed. | ||
| Grains of hardness in your water • supply have increased To check, have the water tested by a water analysis laboratory or call your local water department. Adjust the hardness number setting as needed. | Water hardness can change over time, especially in well water. | |
| System capacity inputs, Salt per • Regeneration and Capacity set too low | See Salt per Regen and Capacity section so system will regenerate about every 5 days. See instructions on pages 12 and 13. | |
| If resin bed is fully exhausted, for example, after a malfunction, one regeneration cycle may not fully restore capacity | · Complete "back to back" regenerations. Initiate Regeneration cycle, wait 1 minute, then press REGEN again. See page 14. | |
| Water feels slippery after installation of water softening system | Absence of hardness minerals | · This is normal. Hardness in water gives it the abrasive feel you may have been accustomed to. The slippery feel is the clean feel of soft water. |
| Water softening system not using any salt | Water softening system is a "demand" unit | · Does not use much salt to regenerate—very efficient. |
| Possible salt bridge | · See the Breaking a Salt Bridge section. | |
| Possible plugged injector and screen | · See the Cleaning the Injector and Screen section. | |
| Water is blue color after water softening system was installed | Acidic water in copper plumbing | · Have the water tested at once. |
| Cloudiness on glassware (automatic dishwashers) | Combination of soft water and too much detergent | · This is called etching and is permanent. To prevent this from happening, use less detergent if you have soft water. Wash glassware in the shortest cycle that will get them clean. |
| Excessive/high level of water in brine tank | Valve drain hose pinched, plugged, elevated too high or otherwise restricted | · Any restriction in this drain hose may prevent proper operation of the injector and screen and reduce or prevent brine draw during regeneration. |
| Injector or injector screen dirty | · See the Cleaning the Injector and Screen section, page 17. With water pressure to the water softening system off, remove the injector and injector screen. Thoroughly clean and flush. Check for any damage. Reassemble to valve assembly. | |
| Salty tasting or brown/yellow colored water after installation | Unit not sanitized | Complete the Sanitizing Procedures on page 15.At completion of regeneration cycle (approx. 2 hrs), run water from faucets to purge the salty water. |
| Low water pressure Check pressure. | Drain height 8' or less, pressure should be minimum of 20 psi.Drain height above 8', pressure should be minimum of 50 psi. | |
| Restricted drain hose • Clean and reconnect drain line.• Check for kinks in drain line. | ||
| Brown/yellow colored water | Unit was idle for a period of time | Complete the Sanitizing Procedures on page 15. |
| Sounds you might hear during regeneration cycle | Running water from the unit into a drain during regeneration | This is normal. High water flows in backwash cycle, flushes minerals and sediments from resin tank. |
| Harmonic noises during regeneration | This is normal. | |
| Clicking | This is normal. This is the sound of various valves opening and closing as valves cycle through regeneration cycle. | |
| Water has air bubbles and is cloudy | Air in system after installation | Will go away after it runs for a while. |
⚠ WARNING: Advanced programming should only be performed by a qualified technician.
This section was designed for the use of water treatment professionals. Default settings are based on water conditions at a typical installation. Before making any changes, consult a water treatment professional, as incorrect settings may result in a system malfunction. Programming the control is not covered under the warranty.
To access advanced programming, simultaneously hold down the UP ▲ and DOWN ▼ buttons. This will allow you to enter advanced programming settings P6 through P19 (see table below).
Advanced Programming Parameters
Minimum Units
Parameter Description Range Increments of Measure Notes
| P6 Refill controller 1-99 1 gpm 0.33 gpm, both models | |||||
| P7 Brine draw value 1-99 1 Minutes | 40L - 15 and 48L - 16 | ||||
| P8 | Not used | N/A | N/A | N/A | N/A |
| P9 | Backwash time | 3-30 | 1 | Minutes | Skip this parameter to accept the default or enter a value. |
| P10 Slow rinse time 8-125 | 1 Minutes | GNPR40L = 67 | GNPR48L = 83 | ||
| P11 | Fast rinse time | 2-19 | 1 | Minutes | Skip this parameter to accept the default or enter a value. |
| P12 | Units of measure | 0-1 | 1 | 0 = U.S.1 = MetricSkip this parameter to accept the default (U.S.). | |
| P13 | Clock mode | 0-1 | 1 | 0 = 12-hour clock1 = 24-hour clockSkip this parameter to accept the default (12-hour). | |
| P14 | Calendar override | 0-30 | 1 | days | 0 = no calendar overrideSkip this parameter to accept the default (no override). |
| P15 | Reserve type | 0-3 | 1 | 0 = variable reserve | |
| P16 | Fixed reserve capacity or initial average value | 0-70 | 1 | percent of capacity | Description depends on the value entered for P15 (Reserve type). Skip this parameter to accept the default. |
| P17 Operation type | 0-1 | 1 | 0 = Not used1 = 5-cycle counter current | ||
| P18 | Salt/capacity change lock out | 0-1 | 1 | 0 = None1 = salt/capacity change locked outSkip this parameter to accept the default (no lock out). | |
| P19 | Factory defaults | DO NOT CHANGE | 1 | Loads in factory default values. DO NOT CHANGE THIS PARAMETER. | |
Default Settings
The following table represents preset values programmed into the system at the factory for both levels for the model shown.
Required Parameters
Name Description GNPR40L GNPR48L
| P1 Time of day Set in field Set in field | |||
| P2 Time of regeneration 2:00 a.m. 2:00 a.m. | |||
| P3 Hardness Set in field (25 grains) Set in field (25 grains) | |||
| P4 Salt amount 7.5 lbs | 9.0 lbs | ||
| P5 Capacity | 24.4 Kgr | 26.1 Kgr | |
Advanced Programming Parameters
Name Description GNPR40L GNPR48L
| P6 | Refill controller | 0.33 gpm | 0.33 gpm | |
| P7 | Brine draw value 15 min. | 16 min. | ||
| P8 | Not used | N/A | N/A | |
| P9 | Backwash time | 12 min. | 12 min. | |
| P10 | Slow rinse time | 67 min. | 83 min. | |
| P11 | Fast rinse time | 4.0 min. | 4.0 min. | |
| P12 | Units of measure 0 | 0 | ||
| P13 | Clock mode | 0 | 0 | |
| P14 | Calendar override | 0 | 0 | |
| P15 | Reserve type | 0 | 0 | |
| P16 | Fixed reserve capacity or initial average value | N/A | N/A | |
| P17 | Operation type | 1 | 1 | |
| P18 | Salt/capacity change lock out | 0 | 0 | |
| P19 | Factory defaults | 9 | 9 |
Manual Indexing for Each Regeneration
The control valve may be manually indexed to each regeneration position as follows:
- Remove the control valve cover.
- Press down on the top of the drive gear to disengage the cam gear. (See Step 1 in Start-Up Rinsing Procedure section.)
- With the cam gear disengaged, rotate the cam gear counterclockwise to the various positions, using the same steps as the Start-Up Rinsing Procedure.
The control valve may also be operated in a fast mode for testing the control. To activate the fast mode, follow Steps 1 and 2 above to disengage the cam gear. When the cam gear is disengaged, it should be advanced slightly in a counterclockwise direction.
The switch will then activate the motor to cause the cam gear to advance through all the cycles in about 30 minutes. The control will not recognize a fast mode as a regeneration. Manual regenerations can be initiated only by pressing the manual regeneration switch on the face of the control.
Errors
This system continuously monitors itself and displays an error message if it detects something wrong.
When an error is detected, the display shows the letters "Err" with a number from 1 to 4. The table below lists Err numbers, a description of each error, the cause of the error and the solutions.
To clear the error from the display, press any button on the control. If the error still exists, the control will display the error message again after 30 seconds.
Error Detection Codes
Code Description Cause Solution
| Err 1 | Electronics failure | Control settings need reprogramming | • Press any key to load default values. Refer to Programming the Control. |
| Err 2 | Improper start of regeneration (limit switch open when it should be REGEN"). closed) | Valve cam gear has been manually rotated during a regeneration | • Press any key to clear the alarm. (Alarm automatically clears at “TIME OF |
| Valve cam gear has been manually rotated out of “service” position the cam gear to the proper location. | • The control will turn the motor on and drive | ||
| Faulty motor | • Replace motor assembly. | ||
| Motor wire disconnected | • Make sure motor wire is fully connected to control. | ||
| Faulty switch | • Replace switch. | ||
| Err 3 | Improper finish of regeneration (limit switch closed when it should be open) | Valve cam gear has been manually rotated out of “service” position | • The control will turn the motor on and drive the cam gear to the proper location. |
| Faulty motor | • Replace motor assembly. | ||
| Motor wire disconnected | • Make sure motor wire is fully connected to control. | ||
| Faulty switch | • Replace switch. | ||
| Err 4 | Improper control settings (one or more settings out of the allowable range) | One or more settings is out of the allowable range | • See the Advanced Programming Parameters section on page 22 and Default Settings section on page 23. |
Troubleshooting Procedures
| Problem Possible Causes What To Do | ||
| Capacity display stays at "9999" even though there is water usage | Total system capacity was calculated to be a value greater than 9999 | As the water usage continues, the remaining capacity will drop below 9999, then other values will be shown. |
| Control does not respond to REGEN button programming mode | Button is not active in the | Wait for 30 seconds until lights begin to alternate. |
| Control does not display time of day | Transformer is unplugged | Check connection to control and wall outlet. |
| No electric power at outlet | Repair outlet or use a working outlet. | |
| Defective transformer | Replace transformer. | |
| Defective circuit board | Replace control. | |
| Control does not display correct time of day | Outlet operated by a switch | Use an outlet not controlled by a switch. |
| Power outage | Reset time of day and replace battery. | |
| No water flow display when water is flowing (colon doesn't blink) | Bypass valve in "bypass" position | Set bypass valve into "service" position. |
| Meter probe disconnected or not fully connected to meter housing | Fully insert probe into meter housing. | |
| Restricted meter turbine rotation due to foreign material in meter | Remove bypass valve, free up turbine and flush with clean water. Turbine should spin freely. If not, refer to the Water Meter Maintenance section. | |
| Defective meter probe | Replace control. | |
| Defective circuit board | Replace control. | |
| Control display is frozen at REGEN TIME REMAINING | Back to back regenerations were requested | Refer to Manual Regeneration section. |
| Control regenerates at the wrong time of day | Power outages | Reset time of day to correct time of day and replace battery. |
| Time of day set incorrectly | Reset time of day to correct time of day. Note PM light. | |
| Time of regeneration set incorrectly | Reset time of regeneration. Note PM light. | |
| Cam gear stalled in regeneration cycle | Motor not operating | Replace motor assembly. |
| Motor runs backward | Replace motor assembly. | |
| No electric power at outlet | Repair outlet or use a working outlet. | |
| Broken gear | Replace gear. | |
| Defective switch | Replace switch. | |
| Binding of cam gear | Remove foreign object obstruction from valve discs or cam gear. | |
| Water pressure greater than 125 psi during regeneration | Install pressure regulator to reduce pressure. | |
| Defective circuit board | Replace control. | |
| Continuous regeneration. Cam gear does not stop at the end of regeneration. | Defective switch | Replace switch. |
| Control does not regenerate automatically or when REGEN button is pressed | Transformer unplugged | Connect power. |
| No electric power at outlet | Repair outlet or use a working outlet. | |
| Defective motor | Replace motor assembly. | |
| Defective switch | Replace switch. | |
| Control does not regenerate automatically but does regenerate when REGEN button is pressed | If water flow display is not operative, refer to "No water flow display when water is flowing" in this table | Refer to "No water flow display when water is flowing" in this table. |
| Incorrect hardness and capacity settings | Set new control values. See the Programming the Control section. | |
| Defective circuit board | Replace control. | |
Advanced troubleshooting.
| Problem Possible Causes What To Do | ||
| Run out of soft water between regenerations (WS15X10059). | Incorrect injector | With water pressure >70 psi, use 4 bump injectors |
| Improper regeneration | Repeat regeneration, making certain correct salt dosage is used. | |
| Fouled resin bed·Use resin cleaner. | ||
| Incorrect salt dose and capacity setting | Set Salt per Regen and Capacity setting to proper level. Refer to the Programming the Control sections. | |
| Incorrect hardness | Set to correct hardness. Refer to the Programming the Control sections. | |
| Water hardness has increased | Set to new value. Refer to the Programming the Control sections. | |
| Restricted meter turbine rotation due to foreign material in meter housing | Remove bypass, free up turbine and flush with clean water. Turbine should spin freely—if not, replace meter. | |
| Water usage below 1/5 gallon per minute | Repair leaky plumbing and/or fixtures. | |
| Brine draw value from Advanced Programming Parameters table is incorrect | Set correct brine draw value. | |
| Incorrect salt type or use of grid plate (salt shelf) | Do not use block salt or grid plate (salt shelf) in brine tank. | |
| Control does not draw brine | Low water pressure | Increase water pressure (20 psi at conditioner). |
| Restricted drain line | Remove obstruction. | |
| Injector or injector screen is plugged | Clean injector and screen. Refer to the Cleaning the Injector and Screen section. | |
| Injector defective | Replace injector and cap. | |
| Valve disc 3 and/or 5 not closed | Manually operate cam gear to flush out foreign matter holding disc open. Replace if needed. | |
| Air check valve prematurely closed | Briefly put control into brine refill status. Refer to the Manual Regeneration section. Repair air check valve if needed. | |
| Brine tank overflow | Brine valve disc 1 held open | Manually operate cam gear to flush out foreign matter holding disc open. |
| Valve disc 2 not closed during brine draw, causing brine refill disc open. | Manually operate cam gear to flush out foreign matter holding | |
| Air leak in brine line to air check | Check all connections in brine line for leaks. | |
| Salt setting too high | Set in new values. Refer to Advanced Programming section. | |
| Float assembly malfunctions | Inspect float assembly in brine well for proper operation. It must be able to move freely. | |
| Intermittent or irregular brine draw | Low water pressure | Increase water pressure (20 psi at conditioner). |
| Defective injector | Replace both injector and injector cap. | |
| No conditioned water after regeneration | Unit did not regenerate | Check for power. |
| No salt in brine tank | Add salt to brine tank. | |
| Plugged injector | Remove injector and flush it and injector screen. | |
| Air check valve closed prematurely | Put control momentarily into REFILL to free air check. Replace or repair air check as needed. | |
| Incorrect salt type or use of grid plate (salt shelf) in brine tank | Do not use block salt or grid plate (salt shelf) in brine tank. | |
| Control backwashes at excessively low or high rate 26 | Incorrect backwash controller | Replace with correct size controller. |
| Foreign matter affecting controller operation | Remove and clean controller. | |
| Flowing or dripping water at drain line or brine line after regeneration | Drain valve (2 or 6) or brine valve (1) held open by foreign matter disc open. | • Manually operate cam gear to flush out foreign matter holding |
| Weak valve stem return spring on top plate | • Replace spring. | |
| Resin in valve | • Clean valve and backwash control. | |
| Hard water leakage during service used. | Improper regeneration | • Repeat regeneration, making sure the correct salt dosage is |
| Leaking bypass valve | • Replace bypass valve. | |
| O-ring around riser tube damaged | • Replace O-ring. | |
| Incorrect salt type or use of grid plate (salt shelf) in brine tank | • Do not use block salt or grid plate (salt shelf) in brine tank. | |
1 Service Position

text_image
Service Position Inlet Outlet Drain treated Water untreated Water Description Position e Closed er Drain Closed Open ass Closed et Open er Drain Closed2 Refill Position

text_image
Refill Position Inlet Outlet Drain Treated Water Untreated Water e Description Position line Open oper Drain Closed et Open pass Closed outlet Open wer Drain ClosedTreated Water
Untreated Water
Valve
No. Description Position
1 Brine Closed
2 Upper Drain Closed
3 Inlet Open
4 Bypass Closed
5 Outlet Open
6 Lower Drain Closed
7 Center Dist. Closed
Treated Water
Untreated Water
Valve
No. Description Position
1 Brine Open
2 Upper Drain Closed
3 Inlet Open
4 Bypass Closed
5 Outlet Open
6 Lower Drain Closed
7 Center Dist. Closed
3 Brine Draw Position

text_image
Marine Draw Position Inlet Outlet Drain Treated Water Untreated Water e Description Position line Open oper Drain Closed let Closed pass Open outlet Closed ower Drain Closed4 Slow Rinse Position

text_image
Low Rinse Position Inlet 3 4 5 6 7 2 Drain Treated Water Untreated Water e Description Position line Open oper Drain Closed et Closed pass Open outlet Closed ower Drain ClosedTreated Water
Untreated Water
Valve
No. Description Position
1 Brine Open
2 Upper Drain Closed
3 Inlet Closed
4 Bypass Open
5 Outlet Closed
6 Lower Drain Closed
7 Center Dist. Open
1 Brine Open
2 Upper Drain Closed
3 Inlet Closed
4 Bypass Open
5 Outlet Closed
6 Lower Drain Closed
7 Center Dist. Open

text_image
5 Backwash Position Inlet Outlet Drain Treated Water Untreated Water Valve No. Description Position 1 Brine Closed 2 Upper Drain Open 3 Inlet Closed 4 Bypass Open 5 Outlet Open 6 Lower Drain Closed 7 Center Dist. Closed6 Fast Rinse Position

text_image
6 Fast Rinse Position Inlet Outlet Drain Treated Water Untreated Water Valve No. Description Position 1 Brine Closed 2 Upper Drain Closed 3 Inlet Open 4 Bypass Open 5 Outlet Closed 6 Lower Drain OpenValve Disc Identification

text_image
Disc 6 - Lower Drain Disc 3 - Inlet Disc 2 - Upper Drain Disc 7 - Center Distributor Disc 5 - Outlet Disc 4 - Bypass Disc 1 - BrineChecking the brine draw and refill function.
- Disconnect power to the control by unplugging the wall transformer or unplugging the power cord from the bottom of the control.
- Press down on the top of the drive gear to disengage the cam gear.
- With the cam gear disengaged, rotate the cam gear counterclockwise to the REFILL position until the air check fills with water, and water flows through the brine line into the brine tank. Do not run for more than three minutes.
- Press down on the drive gear, and rotate the cam gear counterclockwise to the DRAW/RINSE position. Check that water is being drawn from the brine tank. The water level in the brine tank will recede very slowly. Observe the water level for at least one minute. If the water level does not recede, if it goes up or if air enters the transparent air check chamber and the ball falls and seats, refer to the Troubleshooting section in this manual.
- When water is being drawn from the brine tank, press down on the drive gear and rotate the cam gear counterclockwise to just before the SERVICE position. Connect power to the control and allow the motor to drive the cam gear to the SERVICE position. The motor will stop. Run cold water from a nearby faucet until the water is clear and soft.

text_image
Air checkWater meter.
In rare instances, the turbine wheel of the water meter can collect small particles of oxidized iron, eventually preventing the wheel from turning.
If the flow indicator light does not blink when conditioned water is flowing from the unit, it is an indication that the turbine wheel is not turning.

- Disconnect electrical power to the unit.
-
Shut off the water supply or put the bypass valve(s) into the BYPASS position.
-
Relieve resin tank pressure: A. Remove control valve cover. B. Press down on the top of the drive gear to disengage the cam gear. C. With the cam gear disengaged, rotate the cam gear counterclockwise to the BACKWASH position.
Check that there is no water flow through the drain line before performing service or preventative maintenance.
- Disconnect the water conditioner from the plumbing. 30

text_image
Inner gland Turbine wheel Outer gland Turbine assembly- Using a needle-nose pliers, remove the outer gland and the turbine wheel from the outlet of the valve. Generally, it will not be necessary to remove the inner gland.
- Clean all iron deposits and/or debris off the turbine wheel. Excessive accumulation of iron may be removed from the components with a solution of sodium hydrosulfite (or sodium disulfite). Rinse the components thoroughly in clean water after using the iron removal solution.
- Flush accumulated iron deposits and/or debris from the inside of the valve outlet.
- Reinstall the turbine wheel into the outlet side of the valve, being certain that the turbine wheel shaft is carefully seated into the bearing of the inner gland.
- Carefully reinstall the outer gland into the outlet side of the valve. Check turbine rotation.
- Reconnect the water conditioner to the plumbing and follow Initial Start-Up section.
- Open the downstream faucet (conditioned water) and check to be certain that the flow indicator (colon) is blinking.

text_image
Exploded view diagram of a mechanical assembly with numbered parts for identification
text_image
Technical diagram of a mechanical device with numbered components and exploded view detailsGENERAL ELECTRIC PARTS CATALOG
| G | G |
| N | N |
| P | P |
| R | R |
| 4 | 4 |
| 0 | 8 |
| L | L |
| (00) | (00) |
REF. NO. GE PART NO. PART DESCRIPTION QTY QTY
| 0001 WS15X10054 VALVE BODY ASSEMBLY 1 1 | |
| 0002 WS26X10014 DRIVE MOTOR - 60 Hz | 1 1 |
| 0003 WS21X10022 CONTROL ASSEMBLY | 1 1 |
| 0004 WS26X10015 CAM GEAR | 1 1 |
| 0005 WS28X10050 BRACKET | 1 1 |
| 0006 WS02X10037 SCREW, 10-32 X 1/2 | 1 1 |
| 0007 WS26X10016 TURBINE GROUP | 1 1 |
| 0008 WS15X10055 BRINE/BACKWASH CONTROL | 1 1 |
| 0009 WS15X10056 INJECTOR SCREEN ASSEMBLY | 1 1 |
| 0010 WS15X10059 INJECTOR ASSEMBLY, 4 BUMPS | 1 1 |
| 0010 WS15X10060 INJECTOR ASSEMBLY, 5 BUMPS | 1 1 |
| 0011 WS31X10032 INJECTOR CAP ASSEMBLY | 1 1 |
| 0012 WS03X10049 O-RING, 1 X 1-1/4 X 1/8 | 1 1 |
| 0013 WS03X10050 O-RING, 1-5/16 X 1/2 X 3/32 | 1 1 |
| 0014 WS03X10051 O-RING, 3-1/8 ID X 3/16 | 1 1 |
| 0015 WS31X10033 CAP PLUG | 1 1 |
| 0016 WS35X10053 VALVE DISC KIT | 1 1 |
| 0017 WS03X10052 VALVE DISC SPRING | 1 1 |
| 0018 WS31X10034 TOP PLATE WITH SPRINGS | 1 1 |
| 0019 WS35X10054 AIR CHECK KIT | 1 1 |
| 0020 WS26X10017 DRIVE GEAR | 1 1 |
| 0021 WS02X10038 SCREW, 8-18 X 1-1/2 | 1 1 |
| 0022 WS03X10053 SPRING | 1 1 |
| 0023 WS02X10039 TOP PLATE SCREW | 1 1 |
| 0024 WS31X10035 BLACK COVER | 1 1 |
| 0026 WS26X10018 TRANSFORMER - 120V | 1 1 |
| 0027 WS21X10023 MICRO SWITCH | 1 1 |
| 0032 WS32X10024 10 X 44 RESIN TANK | 1 |
| WS32X10027 12 X 48 RESIN TANK | 1 |
| 0033 WS14X10003 DISTRIBUTOR, 10 X 44 TANK | 1 |
| WS14X10004 DISTRIBUTOR, 12 X 48 TANK | 1 |
| 0034 WS01X10016 RESIN MEDIA, 1.5 CUFT 1 1 | |
| 0035 WS31X10036 RESIN TANK COVER | 1 |
| 0036 WS07X10022 BRINE LINE - 5 FT | 1 1 |
| 0037 WS32X10025 BRINE TANK | 1 1 |
| 0038 WS32X10026 BRINE WELL | 1 1 |
| 0039 WS35X10055 FLOAT ASSEMBLY | 1 1 |
| 0040 WS02X10040 OVERFLOW FITTING 1 1 | |
| 0041 WS31X10037 BRINE WELL CAP | 1 1 |
| 0042 WS60X10015 1" COPPER TAIL PIECE | 1 1 |
| 0043 WS15X10057 BYPASS VALVE | 1 1 |
| 0044 WS31X10038 BRINE TANK LID | 1 1 |
| 0047 WS16X10001 BYPASS VALVE GASKETS | 1 1 |

All warranty service provided by our SmartWater™ Authorized Servicer Network. To schedule service, call 800.952.5039 (U.S.) or 866.777.7627 (Canada). Please have serial number and model number available when calling for service.
Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty.
For The Period Of: We Will Replace:
| One YearFrom the date of the original purchase service | Any part of the Water Softening System which fails due to a defect in materials or workmanship.During this limited one-year warranty, GE will also provide, free of charge, all labor and related to replace the defective part. |
| Three YearsFrom the date of the original purchase | The electronic monitor, if it fails due to a defect in materials or workmanship. During this three-year limited warranty, you will be responsible for any labor or related service costs. |
| Ten YearsFrom the date of the original purchase | A replacement brine tank or cabinet, if either fails due to a defect in materials or workmanship.During this ten-year limited warranty, you will be responsible for any labor or related service costs. |
What Is Not Covered:
■Service trips to your home to teach you how to use the product.
■Improper installation, delivery or maintenance.
■Failure of the product if it is abused, misused, altered, used commercially or used for other than the intended purpose.
■Use of this product where water is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
■Replacement of house fuses or resetting of circuit breakers.
■Damage to the product caused by accident, fire, floods or acts of God.
■Incidental or consequential damage caused by possible defects with this appliance, its installation or repair.
■Product not accessible to provide required service.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state's Attorney General.
Warrantor: General Electric Company. Louisville, KY 40225

All warranty service provided by our Factory Service Centers or an authorized technician. For service, call toll free 1.866.777.7627. Please have serial number and model number available when calling for service.
For The Period Of: We Will Replace:
| One YearFrom the date of the original purchase service | Any part of the Water Softening System which fails due to a defect in materials or workmanship.During this limited one-year warranty, GE will also provide, free of charge, all labor and related to replace the defective part. |
| Three YearsFrom the date of the original purchase | The electronic monitor, if it fails due to a defect in materials or workmanship. During this three-year limited warranty, you will be responsible for any labor or related service costs. |
| Ten YearsFrom the date of the original purchase | A replacement brine tank or cabinet, if either fails due to a defect in materials or workmanship.During this ten-year limited warranty, you will be responsible for any labor or related service costs. |
What Is Not Covered:
■Service trips to your home to teach you how to use the product.
■Improper installation, delivery or maintenance.
■Failure of the product if it is abused, misused, altered, used commercially or used for other than the intended purpose.
■Use of this product where water is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
■Replacement of house fuses or resetting of circuit breakers.
■Damage to the product caused by accident, fire, floods or acts of God.
■Incidental or consequential damage caused by possible defects with this appliance, its installation or repair.
■Product not accessible to provide required service.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within Canada. In-home warranty service will be provided in areas where it is available and deemed reasonable by Mabe to provide.
WARRANTOR IS NOT RESPONSIBLE FOR CONSEQUENTIAL DAMAGES.
Warrantor: MABE CANADA INC.
Consumer Support.

GE Appliances Website ge.com
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner's Manuals or order parts online.

Schedule Service ge.com
Expert GE repair service is only one step away from your door. Schedule your service at your convenience by calling 800.GE.CARES (800.432.2737) during normal business hours.

Real Life Design Studio ge.com
GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE's Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

Extended Warranties ge.com
Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800.626.2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

Parts and Accessories ge.com
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

Contact Us ge.com
If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations
GE Appliances, Appliance Park
Louisville, KY 40225

Register Your Appliance ge.com
Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material, or detach and use the form in this Owner's Manual.