GE

AGX10AB - Fridge GE - Free user manual and instructions

Find the device manual for free AGX10AB GE in PDF.

📄 16 pages English EN Download 💬 AI Question
Notice GE AGX10AB - page 2
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about AGX10AB GE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Fridge in PDF format for free! Find your manual AGX10AB - GE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AGX10AB by GE.

USER MANUAL AGX10AB GE

Safety Instructions .....2, 3

Operating Instructions .....4, 5

Care and Cleaning

Air Filter 6

Grille and Case ....6

Outdoor Coils 6

Installation Instructions . . .7-13

Casement Window

Installation....13

Horizontal Sliding

Window Installation .....8-12

Preparation 7

Troubleshooting Tips .....14

Normal Operating Sounds ....14

Consumer Support

Consumer Support ...Back Cover

Warranty ....15

Owner's Manual and Installation Instructions

AGX08

AGX10

Write the model and serial numbers here:

Model # ____

Serial #

Find these numbers on a label on the side of the air conditioner.

GE AGX10AB - Owner's Manual and Installation Instructions - 1

natural_image Abstract decorative swirl design with no text or symbols

3828A20514T 49-7530 11-05 JR

IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.

▲WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

GE AGX10AB - ▲WARNING! - 1

SAFETY PRECAUTIONS

■ Use this appliance only for its intended purpose as described in this Owner's Manual.
■ This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
■ Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
■ Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

■ Turn the unit OFF and unplug your air conditioner before making any repairs or cleaning.

NOTE: We strongly recommend that any servicing be performed by a qualified individual.

■ For your safety...do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

■ All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

GE AGX10AB - SAFETY PRECAUTIONS - 1

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

⚠ WARNING!

GE AGX10AB - ⚠ WARNING! - 1

USE OF EXTENSION CORDS —115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.

However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.

GE AGX10AB - ⚠ WARNING! - 2

USE OF ADAPTER PLUGS —115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.

However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.

The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.

When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.

If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.

Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

GE AGX10AB - ⚠ WARNING! - 3

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

About the controls on the air conditioner.

GE AGX10AB - About the controls on the air conditioner. - 1

text_image 5 6 4 7 3 8 2 9 1 10 COOLEST

1

GE AGX10AB - About the controls on the air conditioner. - 2

text_image OFF HIGH FAN HIGH COOL LOW FAN MED COOL LOW COOL

MODE CONTROLTEMP CONTROL
2

GE AGX10AB - About the controls on the air conditioner. - 3

Controls

GE AGX10AB - Controls - 1

Temp Control

The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

GE AGX10AB - Temp Control - 1

Mode Control

HIGH COOL, MED COOL and LOW COOL provide cooling with different fan speeds.

LOW FAN or HIGH FAN provides air circulation and filtering without cooling.

NOTE: If you move the switch from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.

Cooling Descriptions

For Normal Cooling—Select HIGH COOL or MED COOL with the temp control at 5 or 6.

For Maximum Cooling—Select HIGH COOL with the temp control at 10.

For Quieter & Nighttime Cooling—Select LOW COOL with the temp control at 3 or 4.

Additional controls and important information.

Exhaust Control

The vent control is located in the lower corner of the air discharge grille.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

GE AGX10AB - Exhaust Control - 1

natural_image Pure technical line drawing of a mechanical joint or bracket assembly without any text, numbers, or symbols

To open the vent, pull the lever toward you. To close it, push the lever in.

Air Direction

The side-to-side air direction levers are located in the air discharge louvers, and are adjusted by moving the levers to the left or right.

Fingertip pressure on the horizontal bank of louvers adjusts the air direction up or down.

GE AGX10AB - Air Direction - 1

natural_image Line drawing of a hand inserting air filters into a mounted air conditioner unit (no text or symbols)

Care and cleaning of the air conditioner.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

GE AGX10AB - Outdoor Coils - 1

natural_image Line drawing of a window with slatted door and ventilation grilles (no text or symbols)

Air Filter

The air filter behind the inlet grille should be checked and cleaned at least every 30 days or more often if necessary.

To open the inlet grille and remove the air filter:

1 Grasp both sides of the inlet grille and pull forward. The inlet grille will pivot forward and down to reveal the air filter.
2 Remove the filter by grasping it by the frame and pulling it out.
3 Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.
4 Replace the filter and close the inlet grille.

CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

GE AGX10AB - To open the inlet grille and remove the air filter: - 1

text_image Air filter Inlet grille

Preparing to install the air conditioner.

Read these instructions completely and carefully.

GE AGX10AB - Preparing to install the air conditioner. - 1

Before You Begin

NOTE TO INSTALLER: Leave these instructions with the air conditioner after installation is completed.

NOTE TO CONSUMER: Keep Owner's Manual and Installation Instructions for future use.

CAUTION:

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

IMPORTANT NOTES:

For personal safety, this air conditioner must be properly grounded.

It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.

Follow National Electric Codes (NEC) and/or local codes and ordinances.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

GE AGX10AB - IMPORTANT NOTES: - 1

Electrical Requirements

GE AGX10AB - Electrical Requirements - 1

Some models require 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

GE AGX10AB - Electrical Requirements - 2

Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

GE AGX10AB - Electrical Requirements - 3

Tools You Will Need

■ Screwdrivers

■ Ruler or tape measure

■ Scissors or knife

■ Pencil

Level

■ Drill and 1/8"bit

GE AGX10AB - Tools You Will Need - 1

Before Installing the Air Conditioner

A Open the inlet grille and remove the filter. See the Air Filter section.

B Secure the front grille frame with the two screws packed with the Owner's Manual.

C Replace the filter and close the inlet grille.

GE AGX10AB - Before Installing the Air Conditioner - 1

text_image Inlet grille

Horizontal sliding window installation instructions.

Read these instructions completely and carefully.

Parts Included

GE AGX10AB - Horizontal sliding window installation instructions. - 1

text_image Filler panel Top and bottom seals (2) (discard 1 for sliding window installation) Top guide Support platform Filler panel frame Foam gasket (2) (discard for casement window installation) Side guide (2) Side seal (2) Air conditioner Support angle Leveling bolt and nut Type A (2) Washer (2) and Nut (2) Type B (11) Type C (3) Type D (4) Window locking bracket (1)

Read completely, then follow step-by-step.

GE AGX10AB - Read completely, then follow step-by-step. - 1

Window Requirements

■These instructions are for a horizontal sliding or a casement window.
■The electrical outlet must be within reach of the power cord.

GE AGX10AB - Window Requirements - 1

Horizontal sliding window

■For installation in a casement window, the window frame assembly and the side of the building must be adequate to support the weight of the air conditioner.

GE AGX10AB - Window Requirements - 2

text_image 15/2" min. 16/2" max. 21/2" min.

Casement window
(See Casement Window Installation Instructions)

GE AGX10AB - Window Requirements - 3

Optional—Change the Power Cord Exit

You may change the power cord exit from the bottom to the side, if desired, for appearance or window sill clearance.

A Grasp both sides of the inlet grille and pull forward. The inlet grille will pivot forward and down to reveal the air filter.
B Remove the filter by grasping it by the frame and pulling it out.
C If present, remove both screws from the grille and retain.

GE AGX10AB - Optional—Change the Power Cord Exit - 1

text_image Inlet grille

GE AGX10AB - Optional—Change the Power Cord Exit - 2

text_image Air filter Inlet grille

D Pull the grille frame with your thumb while pushing the case with your fingers. Lift the grille frame up and off.
E Remove the right screw from the power cord clamp. (Replace screw into the empty hole in case the power cord exit ever needs to be reversed.)
F Replace the front grille frame and lead the power cord out the side.
G Replace the two screws (if removed earlier) and the filter, and close the inlet grille.

GE AGX10AB - Optional—Change the Power Cord Exit - 3

natural_image Hand holding a wall-mounted panel or fixture, no visible text or symbols

GE AGX10AB - Optional—Change the Power Cord Exit - 4

text_image Right screw Power cord

GE AGX10AB - Optional—Change the Power Cord Exit - 5

natural_image Pure technical line drawing of a heat exchanger or cooling unit with no text, numbers, or symbols

Horizontal sliding window installation instructions.

Read completely, then follow step-by-step.

3

Install the Window Track Gasket or Seal

For sliding window installation, fold and fit one of the foam gaskets into the window track. This may require cutting the ends of the gasket to make it fit properly in the track. Discard the bottom seal; it is not needed.

For casement window installation, remove the backing from the bottom seal and apply it to the horizontal inside face edge of the window frame. Discard the foam gaskets; they are not needed.

GE AGX10AB - Install the Window Track Gasket or Seal - 1

text_image Window jamb Foam gasket Window track

Sliding Window

GE AGX10AB - Install the Window Track Gasket or Seal - 2

text_image Bottom seal

Casement Window

4

Prepare the Window and the Support Assembly

A Loosely attach the support platform to the support angle using 2 Type A screws, washers and nuts.
B Attach the leveling bolt and nut.

GE AGX10AB - Prepare the Window and the Support Assembly - 1

text_image Type A screws Washers Nuts Support platform Support angle Leveling bolt and nut

The window track may not allow the air conditioner to tilt toward the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.

GE AGX10AB - Prepare the Window and the Support Assembly - 2

text_image 1/16"higher than track Wood Stool

WOOD PIECE—

WIDTH: 2"

LENGTH: Long enough to fit inside window frame.

THICKNESS: To determine the thickness, place a piece of wood between the stool and the support platform to make it 1/16"higher than the top of the window track.

Attach securely with nails or screws provided by the installer.

C Measure and mark a line 8¼" (for sliding windows) or 8½" (for casement windows) from the window jamb. Center the support assembly on the window track. Attach the support platform to the window stool using 4 Type D screws.

NOTE: For casement window installation, the back edge of the support platform must butt flush against the window frame face. Modify window as needed.

Depending on the window track material, you may need to drill holes in the window track through the existing holes in the support assembly to secure the screws.

GE AGX10AB - WOOD PIECE— - 1

text_image 8/4" (sliding window) 8/3" (casement window)

D Pull the support angle against the outside wall and tighten the screws on top of the support platform. Adjust the leveling bolt so the support platform is installed with a slight tilt to the outside. Use a level; about 1/3 bubble will be the correct slant to the outside. Tighten the nut.

GE AGX10AB - WOOD PIECE— - 2

text_image A filler block is recommended for homes with vinyl or aluminum siding

5

Install the Guides to the Case

A Install the top guide with 3 Type B screws.
B Install the side guides with 3 Type B screws on each side. Install the center screw first on both sides.

NOTE: DO NOT drill a hole in the bottom of the pan.

The air conditioner is designed to operate with the bottom of the pan approximately half-full of water.

GE AGX10AB - Install the Guides to the Case - 1

text_image Type B screws Top guide Side guide Type B screws

6

Measure, Cut and Install the Filler Panel

A Measure the height of the window opening from the top of the support platform. Subtract 20¾ inches. Mark this measurement on the filler panel and cut it evenly across.

GE AGX10AB - Measure, Cut and Install the Filler Panel - 1

text_image Measure distance and subtract 20¼ inches.

B Insert the uncut end of the filler panel into the top guide. Center the filler panel side-to-side in the top guide.

GE AGX10AB - Measure, Cut and Install the Filler Panel - 2

text_image Frame Filler panel

C Insert the filler panel frame over the filler panel and into the side guides.

7

Attach the Side and Top Seals

A Remove the backing from the side seals and apply to the vertical inside face edges of the window frame and the sliding window that will rest against the air conditioner.
On casement window installations requiring a filler panel, one of the side seals should be applied to the inside face edge of the filler panel instead of to the window frame.
B Peel the backing from the top seal and apply to the top inside face edge of the window frame.

GE AGX10AB - Attach the Side and Top Seals - 1

text_image Top seal Side seals

Horizontal sliding window installation instructions.

Read completely, then follow step-by-step.

8

Install the Air Conditioner in the Window

A Slide the air conditioner onto the support platform. Be sure the side channels butts against the vertical window jamb and the filler panel frame is against the top window jamb. Slide the inner window sash firmly against the side of the air conditioner and trim any excess from the foam gasket.

GE AGX10AB - Install the Air Conditioner in the Window - 1

text_image Slide window closed

If the air conditioner does not fit securely, remove it and readjust the leveling bolt.

B Screw 2 Type B screws through the two holes in the middle of the bottom bar. Depending on the window configuration, this may require drilling two 1/8"holes in the window channel to align with the existing holes in the bottom bar.

GE AGX10AB - Install the Air Conditioner in the Window - 2

text_image Bottom bar Type B screws Window channel frame

Make sure the air conditioner is firmly anchored to the window channel frame.

C Drill 1/8"holes to align with the existing holes in the frame. Secure with 2 Type C screws.

GE AGX10AB - Install the Air Conditioner in the Window - 3

text_image Type C screw

NOTE: Check all seals and plug any remaining air gaps with a suitable weatherproof caulk.

9

Secure the Window and Install the Window Side Gasket

A Attach the window locking bracket with a Type C screw.
B On sliding window installations, cut the second long foam gasket to the proper length and stuff it between the 2 windows.

GE AGX10AB - Secure the Window and Install the Window Side Gasket - 1

text_image Window side gasket Window locking bracket Type C screw

Casement window installation instructions.

Read these instructions completely and carefully.

1

Prepare the Window

A Decide where the air conditioner will fit best. If you want to install the air conditioner in a window that does not open, you need to remove the glass panes and window dividers to provide an opening at least 15½"wide × 21½"high.
B If the window opening is wider than 15½", you will need to install a filler panel. Make this panel from wood and run it the full length of the window. Attach it securely to the window frame and paint it to protect it from the weather.

GE AGX10AB - Prepare the Window - 1

text_image 15½" wide Window divider 21½" high

C If you want to install the air conditioner in a window that opens, you must remove the catch handle and the entire crank handle assembly. Then either remove the window or fold it back against the building and fasten it securely.
NOTE: If you removed the catch handle and crank handle assembly, fill the holes with caulk to protect against weather.
NOTE: Window molding may need to be modified for proper installation.

GE AGX10AB - Prepare the Window - 2

text_image Catch handle Crank handles

2

Install the Air Conditioner in the Window

Mounting procedure is similar to that described in steps 1–9 of the Horizontal Sliding Window Installation Instructions.

The installations are also typical. Since styles and sizes of casement windows vary widely, it is advisable to have the air conditioner installed by someone skilled in this type of installation.

CAUTION: Do not block the air circulation to the outside louvers.

Before You Call For Service...

GE AGX10AB - Before You Call For Service... - 1

Troubleshooting Tips Save time and money! Review the chart on this page first and you may not need to call for service.

Problem Possible Causes What To Do
Air conditioner does not start is unpluggedThe air conditioner into the outlet.Make sure the air conditioner plug is pushed completely
The fuse is blown/circuit breaker is tripped. the fuse or reset the breaker.Check the house fuse/circuit breaker box and replace the breaker.
Power failure.The unit will automatically re-start in the settings last used after the power is restored.There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.
The current interrupter device is tripped.Press the RESET button located on the power cord plug.If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Air conditioner does not cool as it shouldAirflow is restricted.Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner.
The temp control may not be set high enough.Turn the knob to a higher number. The highest setting provides maximum cooling.
The air filter is dirty.Clean the filter at least every 30 days. See the Care and cleaning of the air conditioner section.
The room may have been hot.When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cold air is escaping.Check for open furnace floor registers and cold air returns.Set the air conditioner's vent to the closed position.
Cooling coils have iced up.See “Air conditioner freezing up” below.
Air conditioner freezing upIce blocks the air flow and stops the air conditioner from cooling the room.Set the mode control at HIGH FAN or HIGH COOL with the temp at 1 or 2. Wait for approximately one hour, then reset to desired temperature.

Normal Operating Sounds

■ You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
■ You may hear the thermostat click when the compressor cycles on and off.

■ Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
■ The fan may run even when the compressor does not.

GE Air Conditioner Warranty.

GE AGX10AB - GE Air Conditioner Warranty. - 1

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, 24 hours a day, visit us at ge.com, or call 800.GE.CARES (800.432.2737). Please have serial number and model number available when calling for service.

Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty.

For The Period Of: GE Will Replace:

One YearFrom the date of the original purchase and related service to replace the defective part.Any part of the air conditioner which fails due to a defect in materials or workmanship.During this limited one-year warranty, GE will also provide, free of charge, all labor
Five YearsFrom the date of the original purchaseAny part of the sealed refrigerating system (the compressor, condenser, evaporator and all connecting tubing) which fails due to a defect in materials or workmanship.During this four-year limited additional warranty, GE will also provide, free of charge, all labor and related service to replace the defective part.

What GE Will Not Cover:

■Service trips to your home to teach you how to use the product.

■Improper installation, delivery or maintenance. If you have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.

■Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.

In commercial locations, labor necessary to move the unit to a location where it is accessible for service by an individual technician.

■Replacement of house fuses or resetting of circuit breakers.

■Failure due to corrosion on models not corrosion-protected.

■Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.

■Incidental or consequential damage caused by possible defects with this air conditioner.

■Damage caused after delivery.

■Product not accessible to provide required service.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state's Attorney General.

GE AGX10AB - What GE Will Not Cover: - 1

GE Appliances Website

ge.com

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner's Manuals, order parts, catalogs, or even schedule service on-line. You can also "Ask Our Team of Experts" your questions, and so much more...

GE AGX10AB - GE Appliances Website - 1

Schedule Service ge.com

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience 24 hours any day of the year! Or call 800.GE.CARES (800.432.2737) during normal business hours.

GE AGX10AB - Schedule Service ge.com - 1

Real Life Design Studio ge.com

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE's Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

GE AGX10AB - Real Life Design Studio ge.com - 1

Extended Warranties ge.com

Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800.626.2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

GE AGX10AB - Extended Warranties ge.com - 1

Parts and Accessories ge.com

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

GE AGX10AB - Parts and Accessories ge.com - 1

Contact Us ge.com

If you are not satisfied with the service you receive from GF., contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations

GE Appliances, Appliance Park

Louisville, KY 40225

GE AGX10AB - Contact Us ge.com - 1

Register Your Appliance ge.com

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material, or detach and use the form in this Owner's Manual.

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : GE

Model : AGX10AB

Category : Fridge