VIKING

TVWH360AW - Range hood VIKING - Free user manual and instructions

Find the device manual for free TVWH360AW VIKING in PDF.

📄 12 pages English EN Download 💬 AI Question
Notice VIKING TVWH360AW - page 2
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about TVWH360AW VIKING

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Range hood in PDF format for free! Find your manual TVWH360AW - VIKING and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TVWH360AW by VIKING.

USER MANUAL TVWH360AW VIKING

natural_image Exterior view of a silver rectangular electronic device with a small internal component (no text or symbols visible)

Tuscany Hoods

TVWH360, CTVWH360

TVWH480, CTVWH480

TVWH660, CTVWH660

Table of Contents

Important Information 2

Warnings 3

Dimensions & Specifications 4

Clearance Dimensions 5

Interior Ventilator Dimensions 6

Exterior Ventilator Dimensions 7

Planning Information 8

Installation 9

Duct Cover Option 10

Service & Registration 11

IMPORTANT—Please Read and Follow!

NOTE: If installing hood with warming shelf panel, install warming shelf panel first.

IMPORTANT – PLEASE READ AND FOLLOW

  • Before beginning, please read these instructions completely and carefully.
  • Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
  • Please observe all local and national codes and ordinances. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition.
  • Damp environment approved models should be installed in a covered non-enclosed area and should be protected from the elements as much as possible.
  • The installer should leave these instructions with the consumer who should retain for local inspector's use and for future reference.
  • Check with a qualified and trained installer or local codes for makeup air requirement, if any.

This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn off the electricity to the hood from the power supply before servicing or cleaning. Our hoods are equipped with variable speed control blowers. These units will not function with a single speed ventilator. All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any non-Viking Range ventilator kit will void the hood warranty.

READ AND SAVE THESE INSTRUCTIONS

WARNING

To reduce the risk of fire, electric shock, or injury to persons, observe the following:

  • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
  • Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  2. Sufficient air is needed for proper combustion and exhausting of gases through the flute (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  3. When cutting of drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  4. Ducted fans must always be vented to the outdoors.
  5. WARNING!: To reduce risk of fire, use only metal ductwork
  6. CAUTION!: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings, or into attics, crawl spaces, or garages.
  7. CAUTION!: To Reduce the Risk of Fire and Electric Shock, Install this rangehood only with remote blower models manufactured by Viking Range, model numbers – DEV900/DEV1200, VEV900/VIL1200 or integral blowers manufactured by Viking,Range model numbers – VINV300/600/1200 or DII1200. NOTE – Please refer inside for specific canopy/blower combinations.

WARNING

To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on "Kitchen Firesafety Tips," published by NFPA.)

  1. SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
  2. NEVER PICK UP A FLAMING PAN. You may be burned.
  3. DO NOT USE WATER, including wet dishcloths or towels a violent steam explosion will result.
  4. Use an extinguisher ONLY if

  5. You know it is a Class ABC extinguisher, and you already know how to operate it.

  6. The fire is small and contained in the area where it started.
    • The fire department is being called.
  7. You can fight the fire with your back to an exit.

CAUTION

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS

Rangehoods must be installed with the ventilators that are specified on their carton indicating suitability with

this model. Other ventilators cannot be substituted.

VIKING TVWH360AW - WARNING - 1

CAUTION

This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

Dimensions & Specifications

A
36" W 3$-7/8" (91.1 cm)
48" W 47-7/8" (121.6 cm)

VIKING TVWH360AW - Dimensions & Specifications - 1

text_image 12" (30.5 cm) 18" (45.7 cm) 12" (30.5 cm) 18" (45.7 cm) 24" (61.0 cm) A (15.2 cm) (6" (15.2 cm)

*NOTE: Optional duct cover sold separately.

18"H. Wall Hoods
Description 36" 48" 66"
Duct cover width35-7/8"(91.1 cm)47-7/8"(121.6 cm)65-7/8"(167.3 cm)
Duct cover depth12" (30.5 cm)
Duct cover height12" (30.5 cm)
Number of lights2 3 3
Number of filters2 3 3
Heat lamps1 2 2
Interior ventilator kitsVINV300/600/1200VINV1200 VINV1200
Exterior ventilator kitsDEV900/1200*DEV1200*/1500**DEV1200*/1500**
In-line ventilator kitsDIL1200 DIL1200DIL1200
Interior duct size7"/10"(17.8/25.4 cm)10"(25.4 cm)10"(25.4 cm)
Exterior duct size10" (24.5 cm)
Interior—Maximum amps4.2/5.2/8.2 10.810.8
Exterior—Maximum amps8.0/5.3 7.8/8.57.8/8.5
In-Line—Maximum amps5.3/7.2 9.6 9.6

** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods.

Clearance Dimensions

VIKING TVWH360AW - Clearance Dimensions - 1

text_image 12" (30.5 cm) *optional duct cover 18" (45.7 cm) 66" min (167.6 cm) to 72" max (182.9 cm) 30" min (76.2 cm) to 36" max (91.4 cm) 36" (91.4 cm)

Interior Ventilator Dimensions

Top View
VIKING TVWH360AW - Interior Ventilator Dimensions - 1

text_image A 36" W 17-15/16" (45.6 cm) A 4-5/8" (11.7 cm) 7" (17.8 cm) dia. duct location B 36" W 35-7/8" (91.1 cm) B

*300 or 600 CFM Interior Ventilator Installation for all Wall Hoods

Top View
VIKING TVWH360AW - Interior Ventilator Dimensions - 2

text_image A 36" W 17-15/16" (45.6 cm) 48" W 23-15/16" (60.8 cm) 66" W 32-15/16" (83.7 cm) A 5-1/2" (14.0 cm) 10" (25.4 cm) dia. duct location B 36" W 35-7/8" (91.1 cm) 48" W 47-7/8" (121.6 cm) 66" W 65-7/8" (167.3 cm)

*1200 CFM Interior Ventilator Installation for all Wall Hoods

*See blower install guide for detail mounting instructions

Exterior Ventilator Dimensions

Top View
VIKING TVWH360AW - Exterior Ventilator Dimensions - 1

text_image A 36" W 17-15/16" (45.6 cm) 48" W 23-15/16" (60.8 cm) 66" W 32-15/16" (83.7 cm) 5-15/16" (15.1 cm) 10" (25.4 cm) dia. duct location B 36" W 35-7/8" (91.1 cm) 48" W 47-7/8" (121.6 cm) 66" W 65-7/8" (167.3 cm)

900 or 1200 CFM Exterior Ventilator Installation for all Wall Hoods

Top View
VIKING TVWH360AW - Exterior Ventilator Dimensions - 2

text_image A 36" W 17-15/16" (45.6 cm) 48" W 23-15/16" (60.8 cm) 66" W 32-15/16" (83.7 cm) 5-15/16" (15.1 cm) 10" (25.4 cm) dia. duct location B 36" W 35-7/8" (91.1 cm) 48" W 47-7/8" (121.6 cm) 66" W 65-7/8" (167.3 cm)

1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all Wall Hoods

Planning Information

Proper installation of ducting is extremely important to ensure maximum performance from any ventilation product.

  • All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated.
  • Straight runs and gradual turns are best; for example, each 90^ elbow is equivalent to 5-10 feet (1.52-3.05 cm) of straight run.
  • Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
  • Proper performance is dependent on proper ducting; make sure that a qualified and trained installer is used.
  • Check with a qualified and trained installer or local codes for makeup air requirement, if any.
  • Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-wire with ground.

Plan where the duct work will be located. Install proper-sized duct work, and roof or wall cap for the type of blower you are using. Recommended hood locations for the most common installations are shown. Adjust your measurements for various heights of ceilings, soffits, cabinets, or ranges/rangetops.

Check Framing
VIKING TVWH360AW - Planning Information - 1

natural_image Technical line drawing of a mechanical assembly with a cylindrical component and a base block (no text or symbols)

NOTE: Because of the weight of the hood make sure that the mounting screws are driven into the framing and not just the drywall. It may be necessary to drill additional holes in the canopy for proper alignment.

VIKING TVWH360AW - Planning Information - 2
NOTE: Wall exhaust must be a minimum of 24" (61.0 cm) from ground. This may vary depending on local codes and geographic location.

Installation

VIKING TVWH360AW - Installation - 1

text_image step 1 1-1/2" x 3/4" (3.8 cm) x (1.9 cm) wood strip 1-3/16" (4.6 cm) 5/16" Nut driver

Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2" x 3/4" wood strip (provided locally) to wall using screws provided.

VIKING TVWH360AW - Installation - 2

text_image slot for Wood strip 5/16" Nut driver step 2

Use additional mounting screws to secure hood to wood strip.

VIKING TVWH360AW - Installation - 3

text_image step 3 5/16" Nut driver

CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary.

VIKING TVWH360AW - Installation - 4

text_image option 5/16" Nut Driper

CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing use additional mounting screws, if necessary.

VIKING TVWH360AW - Installation - 5

text_image step 4 1 2 3

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

VIKING TVWH360AW - Installation - 6

text_image step ⑤ 2

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Duct Cover Option

VIKING TVWH360AW - Duct Cover Option - 1

text_image option 1

Measure distance from ceiling to canopy.

VIKING TVWH360AW - Duct Cover Option - 2

text_image option ②

Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided.

To install ventilation kit refer to ventilation kit installation instructions.

Service & Registration

If service is required, call your authorized service agency.

Have the following information readily available.

  • Model number
  • Serial number
  • Date purchased
    • Name of dealer from whom purchased

Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range, LLC at 1-888-(845-4641), or write to:

VIKING RANGE, LLC

PREFERRED SERVICE

111 Front Street

Greenwood, Mississippi 38930 USA

Record the information indicated below. You will need it if service is ever required. The model and serial number for your hood is located behind the baffle filter on the left side panel in the lower right corner.

Model no. ____ Serial no. ____

Date of purchase ____ Date installed ____

Dealer's name ____

Address ____

If service requires installation of parts, use only authorized parts to ensure protection under the warranty.

THIS MANUAL SHOULD REMAIN WITH THE HOOD FOR FUTURE REFERENCE.

Viking Range, LLC

111 Front Street

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information,

call 1-888-(845-4641)

or visit our web site at vikingrange.com in the US or

brigade.ca in Canada

VIKING TVWH360AW - Service & Registration - 1

VIKING TVWH360AW - Service & Registration - 2

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : VIKING

Model : TVWH360AW

Category : Range hood