Aigis PTZA6-2W23H - Surveillance Camera

PTZA6-2W23H - Surveillance Camera Aigis - Free user manual and instructions

Find the device manual for free PTZA6-2W23H Aigis in PDF.

📄 12 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Aigis PTZA6-2W23H - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypePTZ (Pan-Tilt-Zoom) Surveillance Camera
ModelPTZA6-2W23H
BrandAigis
Ingress ProtectionIP66 (dustproof, waterproof, moisture proof)
Mounting OptionsWall, Pendant, Corner, Pole, Recess (ceiling)
Video OutputBNC connector (75Ω coaxial cable)
Power Supply24VAC
CommunicationRS485 (control), Alarm I/O
Lightning ProtectionTVS Lightning Proof technology (up to 1500W)
Weight (approximate)Not specified, but mounting accessories must support at least 4x unit weight
Dimensions (Recess Hole)225-227 mm diameter
Maximum Cable DistanceRG59/U: 750ft (229m), RG6/U: 1000ft (305m), RG11/U: 1500ft (457m)
Operating EnvironmentOutdoor (IP66), indoor recess
Installation RequirementsSafety factor of at least 4; use threaded sealant tape and RTV sealant for outdoor
MaintenanceClean with damp cloth; do not use liquid or aerosol cleaners
Spare Parts / AccessoriesWall mount, pendant mount, corner bracket, pole bracket, M8 screws, RTV sealant, terminal blocks, BNC connector (not supplied)
RepairabilityRefer servicing to qualified personnel; do not open unit
Safety StandardsComplies with National Electrical Code (US), lightning and surge proofing
Included ComponentsPTZ dome, mounting bracket, terminal blocks, hardware kit, installation manual

Frequently Asked Questions - PTZA6-2W23H Aigis

What power supply does the PTZA6-2W23H require?
The camera requires 24VAC power. Use the supplied terminal block for connection.
Is the camera suitable for outdoor use?
Yes, the outdoor models are IP66 rated, meaning they are dustproof, waterproof, and moisture proof. Ensure proper sealing with thread sealant tape and RTV sealant.
What type of cable is recommended for video transmission?
Use 75Ω coaxial cable with all copper conductor and 95% copper shield. Maximum distances: RG59/U: 750ft, RG6/U: 1000ft, RG11/U: 1500ft.
How is the camera mount installed?
The PTZA6 supports wall, pendant, corner, pole, and recess mounts. Follow the manual for drilling templates and use the provided hardware. Ensure a safety factor of at least 4.
Does the camera have lightning protection?
Yes, it uses TVS Lightning Proof technology to protect against strikes below 1500W and surge impulses. However, proper grounding and surge protection are still required.
How do I clean the camera?
Unplug the unit before cleaning. Use a damp cloth only; do not use liquid or aerosol cleaners.
Can I install an indoor dome outdoors?
No, only outdoor domes (IP66) are suitable for outdoor use. Indoor domes are not waterproof and will be damaged.
What is the maximum ceiling thickness for recess mount?
The recess mount is designed for drop ceilings or sheetrock. Raise the clips until the gap is larger than the ceiling tile thickness. Use support wires if the ceiling cannot support the weight.
How is the pan/tilt module installed?
Handle the module carefully. Align the guide notches with the locking flanges and push gently until the locking clips engage. Do not force it.
Where can I find the installation manual?
The full installation manual is provided in PDF format and can be downloaded from notice-facile.com or the manufacturer's website.

User questions about PTZA6-2W23H Aigis

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Surveillance Camera in PDF format for free! Find your manual PTZA6-2W23H - Aigis and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PTZA6-2W23H by Aigis.

USER MANUAL PTZA6-2W23H Aigis

PTZA6 Series Pan-Tilt-Zoom Domes Installation Manual

Aigis Mechtronics, Inc.

1124 Louise Road, Winston-Salem, NC 27292

Ph (336)795-7740 <ax (336)795-7744

www.aigismech.com

Table2of2Contents2

  1. Important Safeguards....3

1.1. Warnings....3

1.2. +environmental Specifications....3

1.3. Lightning-Proof Requirements....3

1.4. Lightning and Surge Proofing....4

1.5. Water Proofing....4

  1. Installation 4

2.1. Before You Start....4

2.2. Materials Required....4

  1. Bracket Installation....4

3.1. Overview....4

3.2. Bracket Installation....5

3.2.1. Wall Bracket Installation 5

3.2.2. Pendant Bracket Installation 5

3.2.3. Corner Bracket Installation....6

3.2.4. Pole Bracket Installation 7

3.3. Wiring and Installing the Dome Cover......8

3.4. Pan/Tilt Module Installation 9

  1. Recess Mount Installation....10

4.1. Ceiling Hole Preparation.... 10

4.2. PTZ Module Installation....12

4.3. Trim Ring and Dome Bubble Attachment..... 12

IMPORTANT SA<+%UARDS

  1. Read Instructions - All the safety and operating instructions should be read before the unit is operated.

  2. Retain Instructions - The safety and operating instructions should be retained for future reference.

  3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to.

  4. Follow Instructions - All operating and use instructions should be followed.

  5. Cleaning - Unplug the unit from the outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.

  6. Attachments - Do not use attachments not recommended by the product manufacturer as they may cause hazards.

  7. Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit may fall, causing serious injury to a person and serious damage to the unit. Use only with a stand, tripod, bracket, or mount recommended by the manufacturer or sold with the product. Any mounting of the unit should follow the manufacturer's instructions and should use a mounting accessory recommended by the manufacturer.

An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn.

  1. Ventilation - Openings in the enclosure, if any, are provided for ventilation, to ensure reliable operation of the unit, and to protect it from overheating. These openings must not be blocked or covered. This unit

should not be placed in a built-in installation unless proper ventilation is provided or the manufacturer's instructions have been adhered to.

  1. Power Sources - This unit should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply you plan to use, consult your appliance dealer or local power company. For units intended to operate from battery power or other sources, refer to the operating instructions.

  2. Grounding or Polarization - This unit may be equipped with a polarized alternating-current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarized plug. Alternatively, this unit may be equipped with a 3-wire grounding-type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type plug.

  3. Power Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit from the appliance.

  4. Power Lines - An outdoor system should not be located in the vicinity of overhead power lines or other electric light or power circuits or where it can fall into such

power lines or circuits. When installing an outdoor system, extreme care should be taken to keep from touching such power lines or circuits as contact with them might be fatal. U.S.A. models only - refer to the National Electrical Code Article 820 regarding installation of CATV systems.

  1. Overloading - Do not overload outlets and extension cords as this can result in a fire or electric shock.

  2. Object and Liquid Entry - Never push objects of any kind into this unit through openings, as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit.

  3. Servicing - Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.

  4. Damage Requiring Service - Unplug the unit from the outlet and refer servicing to qualified service personnel under the following conditions:

a. When the power supply cord or plug is damaged.

b. If liquid has been spilled or objects have fallen into the unit.

c. If the unit has been exposed to rain or water.

d. If the unit does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions, as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the unit to its normal operation.

e. If the unit has been dropped or the cabinet has been damaged.

f. When the unit exhibits a distinct change in performance--this indicates a need for service.

  1. Replacement Parts - When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards.

  2. Safety Check - Upon completion of any service or repairs to this unit, ask the service technician to perform safety checks to determine that the unit is in proper operating condition.

  3. Coax Grounding - If an outside cable system is connected to the unit, be sure the cable system is grounded. U.S.A. models only--Section 810 of the National Electrical Code, ANSI/NFPA No.70-1981, provides information with respect to proper grounding of the mount and supporting structure, grounding of the coax to a discharge unit, size of grounding conductors, location of discharge unit, connection to grounding electrodes, and requirements for the grounding electrode.

  4. Lightning - For added protection of this unit during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the cable system. This will prevent damage to the unit due to lightning and power line surges.

CAUT ON RISK OF ELECTRIC SHOCK, DO NOT OPEN! CAUTION: TO R+DUC+ TH+ RISK O< +L+CTRICAL SHOCK, DO NOT OP+N COV+RS. NO US+ S+RVIC+ABL+ PARTS AR+ INSID+. R<+R S+RVIC+ TO QUALI

Figure 1 – Typical Outdoor Installation

1.4. Lightning and Surge Proofing

This product uses TVS Lightning Proof technology which can prevent damage to the equipment caused by lightning strickes below 1500W and impulse signals such as surge; but it is also necessary to abide by the above stated precautions to ensure electrical safety.

1.5. Water Proofing

Outdoor domes are IP66 rated which indicates they are dustproof, waterproof, and moisture proof. Do not install an indoor dome in an outdoor environment. Protect the unit from damaged caused by long term water wear. Utilize thread sealant tape and RTV sealant on outdoor units.

2. Installation

Note: Disregard references to RTV sealant and thread sealant tape for indoor installations.

2.1. Before You Start

- Read this manual in detail. - Ensure that all installation and maintenance work is performed by technical personnel with proper qualifications and experience with this type of equipment. - All electrical work must be in accordance with the latest local and national laws and regulations including fire prevention measures. - Ensure that all components were included in the shipment. If any parts are missing contact the shipper. - Handle the pan/tilt module carefully. The camera module is designed to snap into the dome with very little effort. Do not bend and components or attempt to force the unit into place. Do not handle the dome bubble with your hands. - Make sure the installation site is sufficient in terms of structural integrity and/or available space before commencing the installation. Maintain a safety coefficient of at least 4 when installing this product. - The unit is shipped in the safest possible packaging. Keep it for possible future use. If the unit needs to be returned, replace it properly in its packaging and contact your supplier for return authorization and shipping instructions. - When using a wall mount, pendant mount, or corner mount, ensure that the mounting accessory can support at least 4 times the weight of the unit. When using a pole mount, ensure that the installation is in accordance with the lightning-proof requirements stated above. When mounting an indoor unit into the ceiling, utilize support wires if necessary and ensure that the ceiling can support the weight of the unit.

2.2. Materials Required

Minimum Video Coaxial Cable Requirements: - 75Ω impedance - All copper conductor wire (core) • 95% copper shield mesh
International Gauge Max Transmission Distance
RG59/U 750ft (229m)
RG6/U 1,000ft (305m)
RG11/U 1,500ft (457m)
• RS485 Communications cables (refer to Appendix) • 24VAC Power supply cables (refer to Appendix) \- Thread sealant tape • Room Temperature Vulcanizing (RTV) sealant \- Customer-supplied 1.5" NPT pipe for Pendant Mount installations (cut to desired length)

3. Bracket Installation

Figure 2 – PTZ Unit and Acces

3.1. Overview

These units were designed the installer in mind. Quick and simple connections are required to complete the installation. Some of the features include: - External threading of the external cover to easily connect the cover to the mount bracket. - Quick-attach and release mechanism used to connect the camera module to the external cover. - Simple, clearly marked connection board. - Mounting options include wall mount, pole mount, pendant mount and corner mount. ![](images/b484d14e9205df9e8299e175288b112fc766a5775512676e49d527e412e25c5a.jpg) ![](images/e4da4c65a0ecb7a8edeb66044a5390795886014f02c1e3952d8f22adb6e98851.jpg)

3.2. Bracket Installation

Select an appropriate mounting location such that a safety factor of 4 can be achieved.

3.2.1. Wall Bracket Installation

Hold up the wall arm to the desired installation location and use it as a template to mark the center of the drill holes. The upper two holes are slotted for easy installation. Mark the portion of the slotted holes as shown in
. ![](images/ba2b5c5382d927a85bd5471dbcfddfc0e687f1498b11f31418f62c9d091b1c1e.jpg)
3.2.2. Pendant Bracket Installation Hold the pendant mount flange up to the ceiling and mark the hole pattern.
text_image φ103mm 120° 120°
text_image 04 02 05 03 05 01
3.2.3. Corner Bracket Installation Hold up the corner bracket to the desired installation location and use it as a template to mark the center of the drill holes. The hole pattern in shown in
text_image 78.00 mm 140.00 mm
natural_image Technical line drawing of a mechanical assembly with bolt holes and a central circular component labeled '06' (no text or symbols beyond the label)
text_image 01 Cables 02 Wall Mount 01 Cables 02 Wall Mount 03 Corner Bracket 04 M8 x 30mm screw 05 M8 Wall Anchor 06 RTV Sealant
3.2.4. Pole Bracket Installation Apply RTV sealant around the edge of the wall mount as shown in
text_image 01 Cables 02 Wall Mount 03 Pole Bracket 04 Hose Clamps 05 M8x30mm Screw 06 Pole 07 RTV Sealant 02 07
3.3. Wiring and Installing the Dome Cover The 4-position and 12-position terminal blocks are supplied in the packaging of the PTZ dome. The BNC connector is not supplied. Make the required connections based on the diagram in
text_image Alarm Cable C ontrol Cable Vid eo Cable Power Cable BNC conn e c t o r 1 2 76543 A+Bt AUX1 AUX2 Rs485 AC24V %ND
text_image Metal Button
text_image Video Cable Connection P rotec tive Cover A la rm C a b le conne c tion D I P Switch P o w e r C a b le /C on tro l Cable Con ne c tion
text_image M 4Screw G1½"
text_image L+D Metal Button
3.4. Pan/Tilt Module Installation Remove the pan/tilt module from the packaging and inspect it for damage. If the unit needs to be returned to the factory, replace it properly in its packaging as shown in
natural_image Technical line drawing of a device with internal components and a close-up view of a mechanical assembly (no text or symbols)
text_image % u id e notch e AMP Socket Loc king flange s Lo cking clips
text_image Heater wire Heater wire connectors Safety line
text_image Captive Screws
4. Recess Mount Installation Indoor recess-mount domes can be mounted in drop ceilings (a.k.a. ceiling tiles, acoustic ceiling tiles, etc.) or sheetrock ceilings. A typical installation is shown in
natural_image Technical line drawing of a mechanical assembly with no visible text or symbols
4.1. Ceiling Hole Preparation Draw a circle on the ceiling for the hole the PTZ will be mounted into. The dimensions of the hole should be 8.86-in (225mm) minimum to 8.94-in (227mm) maximum, as shown in
text_image Ø225.00⁺².00 ±0.00 mm
text_image Tightening Cap Screw Cap Power Cable Control Cable (RS485) Video Cable Alarm Cable
text_image Metal ButtonMetal Button
text_image Bulkhead connector AC Power / Data Terminal Block Alarm Term inal Block BNC Conn e c tor
text_image AMP Socket L+D
text_image Rai se clips un til the gap is larger than the ceiling tile thickn ess.
natural_image Technical line drawing of a mechanical device with no visible text or symbols
natural_image Technical line drawing of a mechanical assembly with a cylindrical component mounted on a base plate (no text or symbols) If the ceiling is not strong enough to meet the 4x safety factor, support wires can be attached to a support beam and connected to the back of the PTZ housing. text_image M3 tapped holes Attach to housing using M3 Screws Attach to support beam Support wires
4.2. PTZ Module Installation Remove the pan/tilt module from the packaging and inspect it for damage. If the unit needs to be returned to the factory, replace it properly in its packaging as shown in
natural_image Technical line drawing of a device with internal components and a close-up view of a mechanical assembly (no text or symbols)
4.3. Trim Ring and Dome Bubble Attachment Attach the tether to one of the two threaded plastic posts in the trim ring using an M3 screw from the hardware kit (see
text_image Tether Tab and groove M3 plastic threaded posts
text_image % uid e n o tc he AMP Socket Lo ckng flan ge s Lo ckng clip s
natural_image Simple line drawing of a dome-shaped object with concentric rings, intersected by two perpendicular lines (no text or symbols)
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Aigis

Model : PTZA6-2W23H

Category : Surveillance Camera