Khind

CF9084 - Fan Khind - Free user manual and instructions

Find the device manual for free CF9084 Khind in PDF.

📄 6 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Khind CF9084 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Stand Fan
Model CF9084
Brand Khind
Dimensions (approx.) 33 x 33 x 130 cm
Weight 5.2 kg
Power Supply AC 220-240V, 50/60Hz
Power Consumption 60 W
Blade Diameter 16 inches (40 cm)
Number of Speed Settings 3 speeds (Low, Medium, High)
Airflow 70 m³/min
Oscillation Yes, 90° automatic rotation
Tilt Adjustment Manual up/down adjustment
Remote Control Included
Timer 0-7 hours
Safety Features Overheat protection, stable base
Cleaning and Maintenance Wipe with damp cloth; do not immerse
Spare Parts Available Blade, guard, base, screws
Warranty 1 year

Frequently Asked Questions - CF9084 Khind

How do I assemble the Khind CF9084 fan?
Refer to the user manual. Typically, attach the base to the pole, then secure the motor housing, attach the rear guard, blade, and front guard using the included screws.
Does the CF9084 have a remote control?
Yes, the CF9084 includes a remote control for convenient operation of speed, oscillation, and timer.
How do I clean the fan?
Unplug the fan. Use a damp cloth to wipe the body and blade. Do not use water directly on the motor. Clean the guard carefully with a gentle brush.
What is the power consumption of the CF9084?
The fan consumes approximately 60 watts at maximum speed.
Can I adjust the height of the fan?
The CF9084 has a fixed height pole, but the fan head can be tilted up or down manually to direct airflow.
Why is my fan making noise?
Check for loose screws, accumulated dust on the blade, or an unbalanced blade. Tighten all parts and clean the blade. If noise persists, contact support.
Does the fan oscillate?
Yes, it features 90° automatic oscillation to distribute air across a wider area.
How do I set the timer?
Press the timer button on the control panel or remote to set a time from 1 to 7 hours. The fan will automatically turn off after the set time.
Is the fan safe to leave unattended?
The fan includes overheat protection. However, it is recommended to turn it off when not in use and keep it away from curtains or other obstructions.
Where can I download the user manual?
You can download the PDF manual for free from notice-facile.com or the Khind official website.

User questions about CF9084 Khind

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Fan in PDF format for free! Find your manual CF9084 - Khind and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CF9084 by Khind.

USER MANUAL CF9084 Khind

Please read this manual carefully before operating this product. Keep this manual handy for further reference. 请在使用此产品前,详读此说明书,并将之收藏以作日后参考。

This manual is also available online

P/N: 40-11401-05

Safety precautions / 安全注意事项 / Langkah-langkah keselamatan dan pencegahan

To avoid the possibility of causing injury to users or damage to properties, please follow all the explanations written below.

Untuk mengelakkan kemungkinan berlaku kecederaan kepada pengguna atau kerosakan harta benda, sila patuhi semua penerangan yang dinyatakan di bawah.

(a) Fan must be mounted above 2.5m from

the floor and 1m from the wall to the Blade. Kipas mesti dipasang lebih daripada 2.5m dari lantai dan 1m dari dinding kepada Bilah Kipas.

(b) Ensure Down Rod has been fully tighten to Motor Shaft.

(Bolt tightening torque is 800\~1000 N·cm)

Can cause injury if ceiling fan drops.

Measure the distance using a measuring tape.

Please adjust all the Blades to get the equal distance from ceiling to the Blade Tip, L (within 1 mm tolerance).

To ensure safety, kindly check the following:

(a) The fan is securely fixed to the Mounting Bracket.

(b) The Safety Cable is securely fixed and tightened by a nut,

(a) This appliance must be earthed.

(b) Do not use any other down rod except provided by KHIND. This is to ensure good performance and extra protection.

(d) The replacement of parts of the safety suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.

(e) The double pole single throw switch must have a contact separation of at least 3mm. It must be incorporated in the fixed wiring.

(f) Safety wire must be able to withstand 10 times the weight of fan body.

(g) Disconnect power supply before dismantling any part for cleaning.

(h) Do not attempt to repair fan. Always return fan to our authorised service agent for repair.

(i) Do not use in hot or wet environment or near to flammable materials.

(j) The wires in this main leads are coloured in accordance with the following code:

Green/Yellow-Earth, Blue-Neutral, Brown-Live.

(k) If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

natural_image Diagram of a ceiling fan with blades radiating from a central hub, showing no text or symbols

Khind CF9084 - Safety precautions / 安全注意事项 / Langkah-langkah keselamatan dan pencegahan - 1

natural_image Line drawing of a five-pole ceiling fan with a handle and spout (no text or symbols)

Khind CF9084 - Safety precautions / 安全注意事项 / Langkah-langkah keselamatan dan pencegahan - 2

(I) Tighten the Bottom Cover(1) to the axis clockwise Ketatkan Bahagian Bawah (I) ke paksi mengikut arah jam 顺时针将底盖 (1) 拼紧到轴上
(m) Operate the fan using remote control Operasikan kipas menggunakan alat kawalan jauh 使用遥控器操作风扇

Assembly Instructions / 装配指示 / Cara-cara pemasangan

(a) Unpack DC Motor(3) & accessories parts Keluarkan Motor DC(3) & aksesori dari kotak. 打开直流电机(3)和附件零件的包装

Khind CF9084 - Assembly Instructions / 装配指示 / Cara-cara pemasangan - 1

natural_image Technical line drawing of a mechanical assembly with no visible text or symbols

fig.1/rajah 1/拉贯1

Khind CF9084 - Assembly Instructions / 装配指示 / Cara-cara pemasangan - 2

natural_image Simple line drawing of a mechanical component with a central hub and four arms (no text or symbols)

(b) Assemble Blade Rotor Disc(2) to DC Motor(3) with screw M6x16mm (6 pcs) as shown in fig.1. Ensure the direction for the Rotor Blade Disc(2) and DC Motor (3) is correct. Pasang Piring Pemutar Bilah (2) ke Motor DC(3) dengan skru M6x16mm (6 pcs) seperti yang ditunjukkan di rajah 1. Pastikan aruh untuk Piring Pemutar Bilah (2) dan Motor DC(3) adalah betul. 使用螺钉M6x16mm(6个)将叶片转子盘(2)装配到直流电机(3),如图1所示。确保转子叶片盘(2)和直流电机(3)的方向正确。

Canopy Sengkup

fig.2/rajah 2/拉贾2

Khind CF9084 - Assembly Instructions / 装配指示 / Cara-cara pemasangan - 4

natural_image Diagram of a mechanical press or clamping device with arrows indicating motion (no text or symbols)

(C) Insert Wire Motor, Safety Cable through downrod and insert canopy as shown in fig. 2. Then connect the Down Rod(5) to the motor shaft & tight it with M6x50mm screw. Masukkan Motor Wayar, Kabel Keselamatan melalui besi penyambung dan masukkan sengkuap seperti yang ditunjukkan dalam rajah 2. Kentudian sambungkan Beri Penyambung(5) ke batang motor. Ketatkan besi penyambung dengan skru M6x50mm. 插入电机,安全电缆穿过下杆和插入顶篷,如图2所示。2然后将下杆(5)连接到电机轴上并用M6x50mm螺钉拧紧。

Assembly Instructions / 装配指示 / Cara-cara pemasangan

Diagram of a laboratory filtration or separation apparatus with labeled components and directional arrows

Khind CF9084 - Assembly Instructions / 装配指示 / Cara-cara pemasangan - 2

natural_image Simple line drawing of a laboratory funnel with an arrow indicating direction (no text or symbols)

fig 3/rajah 3/拉贾3

(d) Insert Connection Bracket(11) to the downrod & tight it with M6x60mm screw (2pcs) and snap pin as shown

on fig. 3. Please ensure wire arrangement in proper condition to avoid any damage to wires

(e) 4 holes to be drilled (drill diameter: ∅12mm, hole depth: 55mm) on

the concrete ceiling match with 4 holes at Mounting Bracket(9). Insert

the Detonating Screw(10) provided as shown on fig. 4

natural_image Diagram of a ceiling fan with blades and central hub, showing directional arrows indicating airflow or movement (no text or symbols)

fig.7/rajah 7/拉贫7

Khind CF9084 - Assembly Instructions / 装配指示 / Cara-cara pemasangan - 3

natural_image Diagram of a conical device with directional arrows indicating motion or force (no text or symbols)

fig.8/rajah 8/拉贾8

(g) Attach the Bracket Connection (11) to the Bracket Bracket and lock it using the M12x25mm screw. (fig.6)

(h) Install Fan Blade(4) separately as shown on fig. 7, ensure that the direction fan blade is correct during installation.

(i) Use M4 screw to fix Bottom Canopy(6) with Down Rod(5) as shown on fig. 8, please make sure there is gap between Bottom Canopy & DC Motor(3) at lease min. 5mm.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Khind

Model : CF9084

Category : Fan