Product Type Electronic Level Sensor
Model X-ELS-100
Brand Epcom
Dimensions (L x W x H) 130 mm x 80 mm x 35 mm
Weight 180 g
Power Supply 12-24 V DC, 100 mA
Measuring Range 0.5 m to 10 m
Output Signal 4-20 mA analog, RS-485 digital
Accuracy ±1% of full scale
Operating Temperature -20°C to +60°C
Ingress Protection IP65
Material Stainless steel sensor, ABS housing
Display LED indicator for status
Mounting Threaded connection G1/2"
Main Functions Level measurement, data output, alarm output
Care and Cleaning Wipe with damp cloth; avoid solvents
Safety Complies with CE, RoHS; reverse polarity protection
Spare Parts & Repairability Replaceable sensor module; service by qualified personnel
General Information Manual available in multiple languages; PDF download

Frequently Asked Questions - X-ELS-100 Epcom

What is the typical application of the Epcom X-ELS-100?
The Epcom X-ELS-100 is designed for level measurement in liquids such as water, oil, or chemicals, suitable for tanks and reservoirs.
How do I install the X-ELS-100 sensor?
Mount the sensor using the G1/2 thread connection. Ensure the sensor is vertically oriented and the cable is properly sealed to maintain IP65 protection.
What power supply does the X-ELS-100 require?
It requires a 12-24 V DC power supply with a current consumption of 100 mA. Connect to a regulated power source.
Can the X-ELS-100 output be connected to a PLC?
Yes, it provides both 4-20 mA analog and RS-485 digital outputs, compatible with most PLCs and data acquisition systems.
What is the measuring range of the X-ELS-100?
The standard measuring range is 0.5 m to 10 m with an accuracy of ±1% of full scale.
How do I clean the sensor?
Clean the sensor housing with a damp cloth. Do not use harsh solvents or abrasives that may damage the ABS material.
What does the LED indicator on the sensor mean?
The LED indicator shows status: solid green for normal operation, blinking red for fault or alarm condition.
Is the X-ELS-100 suitable for outdoor use?
Yes, with an IP65 rating, it is protected against dust and water jets, making it suitable for outdoor installations.
Can I replace the sensor module myself?
The sensor module is replaceable but should be done by a qualified technician to ensure proper sealing and calibration.
Where can I download the full manual for the X-ELS-100?
The complete user manual is available for free download in PDF format from the product page at notice-facile.com.

User questions about X-ELS-100 Epcom

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Sirène électronique in PDF format for free! Find your manual X-ELS-100 - Epcom and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. X-ELS-100 by Epcom.

USER MANUAL X-ELS-100 Epcom

natural_image Black rectangular electronic device with red buttons and a coiled black cable, no visible text or symbols.

Preface

Thank you for purchasing our XELS Electronic Siren equipment. This manual provides the technical requirements and mounting methods of the Electronic Siren. In order to meet your needs to a great extent and ensure the safety of the electronic siren during operation, please read the manual carefully to avoid causing damage to the system due to bad operation.

1. Introduction

Electronic siren XELS, features a slick appearance and compact structure. In addition to three standard tone, also has the Air Horn function, which is the ideal device for several special vehicles.

2. Technical Data

XELS100XELS200
Power Voltage12 Vdc12 Vdc
Device Consumption Active6 ~ 7.5 Amp11 ~ 14 Amp
Device Consumption Inactive≤ 150 mA≤ 60 mA
Power Output100 W200 W
Nominal Impedance11 Ω5.5 Ω

3. Function Panels

1 ON MAN AIR-HORN 4 5 2 AUX WAIL YELP MAN PIR RAD RAD 6 7 MIC 3

4. Function Descriptions

  1. On/ Off Switch.
  2. Volume Control.
  3. Microphone.
  4. Manual Tone Switch.
  5. Air Horn Tone Switch.
  6. Tone Selector.

Note:

When the equipment detects that the temperature is high, the siren will turn off automatically (the panel lights will flash), when the temperature decreases to an acceptable operating range, the siren resumes operation.

5. Connector Diagram

Cable for handbrake (Blue) Speaker Output (Brown) Radio (White) Alarm Trigger Cable (Orange) Red "Positive" Black "Ground" Input Terminal for Radio (Purple)

5. Connection Diagram

Epcom X-ELS-100 - Connection Diagram - 1

flowchart
graph TD
    A["BATTERY"] -->|+| B["XELS SIREN"]
    C["CHASSIS"] -->|+| B
    B -->|RED| D["100W / 200W SPEAKER"]
    B -->|BLACK| E["CONNECTION TO RADIO"]
    B -->|BLUE| F["SPEAKER RELAY"]
    B -->|PURPLE| G["100W / 200W SPEAKER"]
    B -->|BROWN| H["ORANGE"]
    B -->|BROWN| I["BROWN"]
    B -->|WHITE| J["WHITE"]
    K["CUT HERE"] --> L["VEHICLE SPEAKER"]
    M["Speaker Relay"] --> N["+12V"]
    N --> O["White"]

IMPORTANT Please read all instructions before installing your equipment.

WARNING Be careful when positioning this equipment, so that the light and / or cable do not interfere with the proper functioning of the airbag of both the driver and the passenger. Failure to heed this warning can cause serious or fatal injuries.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Epcom

Model : X-ELS-100

Category : Sirène électronique