| Product Type | Measurement Signal Conditioner |
| Model | 2169-200 |
| Brand | Daytronic |
| Dimensions (W x H x D) | 12.0 x 3.5 x 8.0 inches (approx.) |
| Weight | 4.5 lbs (approx.) |
| Power Supply | 115/230 VAC, 50/60 Hz, 15 VA |
| Input Channels | Up to 10 differential inputs |
| Output Signal | ±10 V analog output per channel |
| Bandwidth | DC to 10 kHz |
| Accuracy | ±0.1% of full scale |
| Main Functions | Signal amplification, filtering, and conditioning for various sensors |
| Compatible Sensors | Strain gauges, thermocouples, RTDs, LVDTs |
| Operating Temperature | 0°C to 50°C (32°F to 122°F) |
| Storage Temperature | -20°C to 70°C (-4°F to 158°F) |
| Humidity | 5% to 95% non-condensing |
| Enclosure Material | Aluminum with steel chassis |
| Display | None (typically rack-mounted) |
| Interface | Front-panel BNC connectors, rear-panel terminal block |
| Calibration | Annual recalibration recommended; internal calibration reference |
| Safety Certifications | CE, UL listed (when applicable) |
| Maintenance | Keep clean, dry; no user-serviceable parts internally |
| Spare Parts | Fuses, input connectors available from manufacturer |
| Reparability | Repair by qualified technician only; factory service available |
| General Information | Designed for industrial and laboratory measurement applications |
Frequently Asked Questions - 2169-200 Daytronic
What is the Daytronic 2169-200 used for?
The Daytronic 2169-200 is a signal conditioner for amplifying and filtering analog signals from various sensors like strain gauges, thermocouples, and LVDTs.
How many input channels does the 2169-200 have?
It supports up to 10 differential input channels, each providing a ±10 V analog output.
What is the power requirement for the 2169-200?
It operates on 115/230 VAC, 50/60 Hz, with a power consumption of approximately 15 VA.
How do I calibrate the Daytronic 2169-200?
Calibration is done using the internal calibration reference. It is recommended to perform annual recalibration to maintain accuracy.
Can the 2169-200 be used with thermocouples?
Yes, it is compatible with thermocouples as well as strain gauges, RTDs, and LVDTs with appropriate input modules.
What is the bandwidth of the 2169-200?
The bandwidth is DC to 10 kHz, suitable for many dynamic measurement applications.
Is the Daytronic 2169-200 CE certified?
Yes, it carries CE certification and is typically UL listed for safety.
What maintenance is required for the 2169-200?
Keep the unit clean and dry. There are no user-serviceable parts inside; refer to a qualified technician for repairs.
How do I connect sensors to the 2169-200?
Sensors are connected via front-panel BNC connectors or rear-panel terminal blocks, depending on the configuration.
Where can I find spare parts for the 2169-200?
Spare parts such as fuses and input connectors are available from Daytronic or authorized distributors.
User questions about 2169-200 Daytronic
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Measurement in PDF format for free! Find your manual 2169-200 - Daytronic and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 2169-200 by Daytronic.