CW-16V1F317 - Bloc d'extension Server Technology - Free user manual and instructions
Find the device manual for free CW-16V1F317 Server Technology in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Vertical Mount Power Distribution Unit |
| Model | CW-16V1F317 |
| Brand | Server Technology |
| Number of Outlets | 16 |
| Outlet Type | IEC 60320 C13 |
| Input Plug | IEC 60320 C20 (16A rating) |
| Input Voltage | 200-240 V AC, 50/60 Hz |
| Maximum Current | 16A per phase |
| Power Rating | 3840 VA (at 240V) |
| Form Factor | Vertical rackmount (0U), 1.7m (67") cable |
| Dimensions (H x W x D) | 1790 x 55 x 44 mm (70.5 x 2.2 x 1.7 in) |
| Weight | 5.4 kg (11.9 lb) |
| Management | SNMP, Web interface, Telnet, SSH |
| Remote Monitoring | Per-outlet current, voltage, power, temperature, humidity sensor |
| Switching | Individual outlet control via network |
| LED Indicators | Power status, network link, outlet status |
| Safety Compliance | CE, RoHS, UL 60950-1 |
| Operating Temperature | 0°C to 50°C (32°F to 122°F) |
| Warranty | 2 years limited |
Frequently Asked Questions - CW-16V1F317 Server Technology
What is the input voltage and plug type for the CW-16V1F317?
The input voltage is 200-240 V AC, 50/60 Hz, and it uses an IEC C20 16A inlet plug.
How many outlets does this PDU have and what type?
It has 16 IEC C13 outlets, commonly used for servers and IT equipment.
Can I control individual outlets remotely?
Yes, the PDU supports remote switching via SNMP, web interface, or CLI. Each outlet can be turned on/off individually.
What is the maximum current rating?
The maximum current is 16A per phase, resulting in a total power capacity of 3840 VA at 240V.
Does it support environmental monitoring?
Yes, it has built-in sensors for temperature and humidity, and can connect external sensors via optional accessories.
What is the form factor and mounting options?
It is a vertical (0U) rackmount PDU, 1.7m long, designed to mount on the side of a server rack.
How do I reset the PDU to factory defaults?
Hold the reset button on the front panel for 5 seconds, or use the web interface to restore factory settings.
What network protocols are supported for remote management?
It supports SNMP v1/v2c/v3, HTTP/HTTPS, Telnet, SSH, and DHCP/static IP configuration.
Is there a local display for power readings?
No, it does not have a local display; all monitoring and control are done via network connection.
What safety certifications does this PDU have?
It is CE, RoHS, and UL 60950-1 certified, ensuring safe operation in data centers.