Product Type See-Through Wood Fireplace (Inbuilt)
Brand Regency
Model Mansfield L850B ST
Overall Dimensions (Width x Depth x Height) 1073 mm x 499 mm x 927 mm (without base frame; with optional base frame add 300 mm height)
Weight Approx. 300 kg (unit only; base must support at least 332 kg)
Fuel Type Natural hardwood only (seasoned air-dried, moisture <20%)
Maximum Heat Output (Hardwood) 13 kW
Overall Efficiency (Hardwood) 63%
Particulate Emission Factor 1.3 g/kg
Flue System Regency triple skin approved flue kit; minimum 4.6 m above floor protector; 50 mm clearance to combustibles
Minimum Enclosure Dimensions (Width x Depth x Height) 1580 mm x 569 mm (finish dependent) x 2400 mm
Floor Protector Requirements 9 mm thick non-combustible material, 1220 mm wide, 300 mm deep (recommended 900 mm in front)
Base Frame Height Minimum 300 mm (non-combustible, hollow center for outside air)
Ventilation Grilles Two grilles (one above, one below doors), minimum 8000 mm² open area each
Optional Fan Kit Up to 2 fan kits, max 9 m duct run, 150 mm diameter flexible duct
Optional Outside Air Kit Recommended for airtight homes; install before fireplace placement
Firebrick Material Ceramic firebricks (sides, bottom) and baffle bricks (top)
Glass Type Neoceram ceramic glass (replacement part #2510221)
Door Seal 16 mm door rope seal (part #3720101A)
Controls Single air slide control (primary and air wash); pull right to open, left to close
Warranty 15 years on welded firebox steel (labor coverage varies); see manual for full details

Frequently Asked Questions - Mansfield L850B ST Regency

What type of wood can I burn in the Mansfield L850B ST?
Burn only untreated, air-dried seasoned hardwoods with moisture content below 20%. Do not burn treated wood, tea tree, oil-based woods, coal, cardboard, solvents, colored paper, or household waste.
What are the minimum clearance requirements?
The enclosure must use non-combustible framing and finishing. A 25 mm clearance is needed between any vertical or horizontal stud and the reduced clearance box. Triple skin flue requires 50 mm clearance to combustibles. The floor protector must extend 300 mm from the door (recommended 900 mm in front).
How do I start a fire?
Open the air slide fully. Use paper and dry kindling to start. Add start-up wood, then once established, add seasoned logs. After about 45 minutes, adjust air slide to moderate level. Never use flammable liquids to start or rekindle the fire.
How often should I clean the flue?
Inspect the flue at least every two months during heating season. Clean when creosote buildup reaches 3 mm. Have the flue professionally cleaned at least once a year, or more frequently if needed.
Why is my glass getting dirty?
Dirty glass can result from closing the air control too soon, burning wet wood, a dirty flue, insufficient combustion air, or worn door seals. Leave the air slide open for 10-15 minutes after reloading, and burn only seasoned hardwood to keep glass clean.
What should I do if the fire burns too fast?
Check that the door is properly closed and latched. Ensure the air slide is not left fully open. Worn seals can also cause excessive draft. If the flue is too tall, a flue damper may help. If the unit glows, you are overfiring – stop loading fuel and close the air slide and doors immediately.
How do I replace the glass?
Use approved personal protective equipment. Remove the door, then remove the top glass retainer, loosen bottom retainer bolts, and loosen side retainer screws. Carefully remove the old glass, install a new glass seal, place the new glass (part #2510221), and reassemble in reverse order.
Can I install a fan kit?
Yes, up to two optional fan kits can be installed. Each uses 150 mm diameter flexible duct with a maximum run of 9 meters. The fan housing must have 6 mm clearance to combustibles and be mounted to 407 mm on-center studs. Wiring must be done by a qualified electrician.
What is the warranty coverage?
The welded firebox steel is covered for 15 years, with labor for the first 2 years. Other components like stainless steel, air tubes, glass (thermal breakage), and electrical parts have 1-5 year coverage. Firebricks are not covered. See the full warranty in the manual for details.
Do I need outside air for this fireplace?
It is strongly recommended for airtight homes (e.g., 5-6 Star energy rated). The optional outside air kit must be installed before the fireplace is placed on the base frame. Ensure the base is hollow in the center to allow connection.

User questions about Mansfield L850B ST Regency

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Heating in PDF format for free! Find your manual Mansfield L850B ST - Regency and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Mansfield L850B ST by Regency.

USER MANUAL Mansfield L850B ST Regency

Owners & Installation

Regency Mansfield L850B ST - Owners &amp; Installation - 1

REGENCY®

FIREPLACE PRODUCTS

SEE-THRU WOOD FIREPLACE

Model: MANSFIELD L850B ST

Manual

Regency Mansfield L850B ST - Manual - 1

natural_image Modern living room interior featuring a single fire extinguisher with visible flames, surrounded by wall-mounted wood and a large window (no text or symbols)

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

WARNING:

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult an authorised installer, service agency or the distributor.

It is highly recommended for protection of infants and infirm to place a secure safety guard in front of this appliance when in operation.

Thank you for purchasing a REGENCY FIREPLACE PRODUCT

The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.

Keep those REGENCY FIRES burning.

SAFETY NOTE: If this wood fire is not properly installed, a house fire may result. For your safety, follow the installation instructions, contact local building, fire officials, or authority having jurisdiction about restrictions and installation inspection requirements in your area.

The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit.

CAUTION: BURN UNTREATED WOOD ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVATIVES, METAL FOILS, COAL, PLASTIC, GARBAGE, SULPHUR OR OIL WILL DAMAGE THE FIRE AND ATMOSPHERE.

"This wood heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as compared to green or freshly cut hardwoods."

DO NOT BURN (WILL VOID WARRANTY):

  • Treated wood
  • Tea Tree
  • Oil Based woods
  • Coal
  • Cardboard
  • Solvents
  • Colored Paper
  • Household Waste

Regency Mansfield L850B ST - DO NOT BURN (WILL VOID WARRANTY): - 1

WARNING!

Regency Mansfield L850B ST - WARNING! - 1

natural_image Illustration of two hands reaching toward a red circular object with wavy lines, enclosed in a partial square frame (no text or symbols)

HOT GLASS WILL CAUSE BURNS

DO NOT TOUCH GLASS UNTIL COOLED

ONLY CLEAN APPLIANCE WITH A DAMP CLOTH (NEVER WHEN UNIT IS HOT) DO NOT USE ANY ABRASIVE CLEANERS

table of contents

Copy of Data Badge 4

Unit Dimensions....5

Before Installing Your Fireplace....6

INSTALLATION ....7

Safety Guidelines and Warnings/Cautions......7

Unit Dimensions....8

Reduced Clearance Box Dimensions....8

Wood Fireplace Specifics and Minimum Clearances .....9

Flue Clearances to Combustibles ....10

Optional Base Frame 11

Flue Requirements ....12

Installation Instructions - Unit Preparation/Framing ...14

Installation Instructions -Unit Preparation/Framing and

Wall Finishing....17

Flue & Chimney Requirements....18

Optional Fan Kit Installation 20

Fan Duct Extension Kit....22

Wiring Diagram....22

Optional Outside Air Kit Installation 23

Firebrick Installation 24

MAINTENANCE 25

Appliance Maintenance....25

Creosote....25

Ash Removal....25

Glass Installation....25

Maintenance 25

Glass Maintenance 25

Door Latch Adjustment....25

OPERATING INSTRUCTIONS......26

Operating Instructions....26

Air Slide Control 26

Wood Storage 26

Lighting the Appliance & the First Few Fires ......27

Troubleshooting 28

PARTS LIST......29

WARRANTY....31

Installation of Appliance Checklist....31

Warranty 32

This is a copy of the data badge that accompanies each L850B ST Fireplace. We have included a copy of the contents here for your review.

NOTE: Regency units are constantly being improved. Check the data badge on the unit and if there is a difference, the data badge on the unit is the correct one.

COPY OF DATA BADGE

MAKE: REGENCYTYPE: FIREPLACE INBUILT
Model: MANSFIELD L850B STSerial Number 444
TESTED BY: AUSTRALIA SOLID FUEL TEST REPORT NUMBER: ASFT16012-1 TESTING PTY LTD.3 GARDEN STREET, MORWELL VIC 3870WHEN TESTED IN ACCORDANCE WITH AS/NZS 4012:2014 & AS/NZS 4013:2014MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD: 13 kWOVERALL AVERAGE EFFICIENCY BURNING HARDWOOD: 63%PARTICULATE EMISSION FACTOR: 1.3 g/kgCATALYTIC COMBUSTOR: NOMANUFACTURER/DISTRIBUTOR: FIREPLACE PRODUCTS AUSTRALIA PTY. LTD.99 COLEMANS ROAD, DANDENONG SOUTH VIC. 3175
Date of Manufacture:JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2021 2022 2023 2024 2025□ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ ▢ 919-639b

UNIT DIMENSIONS

1193 1098 1073 790 1281 1227 310 300 927 ...

645 569 499 1098

499 927 493

Note: All dimensions in millimetres.

installation

Regency Fireplaces are constructed with the highest quality materials and assembled under strict quality control procedures that ensure years of trouble free and reliable performance.

It is important that you read this manual thoroughly and fully understand the safe installation and operating procedures. The more you understand the way your Regency Fireplace operates, the more enjoyment you will experience from knowing that your unit is operating at peak performance.

BEFORE INSTALLING YOUR FIREPLACE

1) Please read this entire manual before you install and use your new wood fireplace. Failure to follow instructions may result in property damage, bodily injury or even death. Install and use only in accordance with manufacturer's installation and operating instructions.
2) Check your local building codes - Building Inspection Department. You may require a permit before installing your fireplace. Be aware that local codes and regulations may override some items in the manual.
3) Notify your home insurance company that you plan to install a wood heater.
4) THE FIREPLACE CAN GET VERY HOT. DO NOT INSTALL, PLACE OR POSITION TV'S, PAINTINGS, PICTURES, CANDLES, FURNITURE, DRAPES OR ANY OTHER COMBUSTIBLE ITEMS ON THE WALL OR NEAR THE FIREPLACE.
5) ENSURE THERE ARE NO EXHAUST FANS WITHIN THE VICINITY OF THE FIREPLACE AS THIS CAN CAUSE THE FIREPLACE TO EMIT FUMES BACK INTO THE ROOM.
6) ENSURE THERE IS ADEQUATE AIR SUPPLY WITHIN THE ROOM/AREA THE FIREPLACE IS BEING INSTALLED IN TO ENSURE PROPER OPERATION OF THE FIREPLACE. INSTALL OPTIONAL OUTSIDE AIR KIT IF IN DOUBT.
7) EVALUATE THE LOCATION OF YOUR FIREPLACE AND OPTIONAL COMPONENTS. IT IS VERY IMPORTANT TO DETERMINE HOW THE FIREPLACE IS GOING TO BE FINISHED. THE FEATURES YOU WOULD LIKE TO INCORPORATE SUCH AS FINISH TRIM, OUTSIDE AIR AND FAN KIT NEED TO BE EVALUATED BEFORE COMMENCING INSTALLATION.
8) DETERMINE WHAT THE THICKNESS OF YOUR DESIRED NON-COMBUSTIBLE FINISHING MATERIALS WILL BE INCLUDING THE NON-COMBUSTIBLE BOARD. THIS PREDETERMINED THICKNESS WILL DICTATE THE POSITION OF THE NAILING STRIPS, FRAMING AND OVERALL FINAL LOOK OF YOUR FIREPLACE.
9) Your fireplace is heavy and requires two or more people to move it safely. The fireplace can be badly damaged by mishandling and or injury can occur.
10) Do not connect the fireplace to a flue system servicing another appliance or an air distribution duct.

WARNING: CARELESS INSTALLATION IS THE MAJOR CAUSE OF SAFETY HAZARDS. CHECK ALL LOCAL BUILDING AND SAFETY CODES BEFORE INSTALLATION OF UNIT.

THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES.

SAFETY GUIDELINES AND WARNINGS/CAUTIONS

1) Never use petrol, petrol type lantern fuels, kerosene, charcoal lighter fuel, or similar liquids to start or 'freshen up' a fire in your heater. Keep all such liquids well away from the heater while it is in use.
2) Keep the door closed during operation and maintain all seals in good condition.
3) Do not burn any quantities of paper, garbage, and never burn flammable fluids such as petrol, naptha or engine oil in your heater.
4) If you have smoke detectors, prevent smoke spillage as this may set off a false alarm.
5) Do not overfire heater. If the flue, flue baffle or the heater top begin to glow, you are overfiring. Stop adding fuel and close the air slide control and both doors. Overfiring can cause extensive damage to your heater including warpage and premature steel corrosion. Overfiring will void your warranty.
6) Do not permit creosote or soot build-up in the flue system. Check and clean flue at regular intervals. Failure to do so can result in a serious flue fire.
7) Your Regency heater can be very hot. You may be seriously burned if you touch the heater while it is operating, keep children, clothing and furniture away. Warn children of the burn hazard. For safety reasons a guard around the fire is recommended.
8) The heater consumes air while operating, provide adequate ventilation with an air duct or open a window while the heater is in use or use optional outside air kit.
9) Do not use grates or andirons or other methods for supporting fuel. Burn directly on the base or bricks where supplied.
10) Open the air slide control fully for 10 to 15 seconds prior to slowly opening the door when refuelling the fire.
11) Your wood fire should burn dry, hardwood, firewood only. The use of cut timber, plywood, "mill ends", etc. is not allowed as this fuel can easily overheat your wood fire. Evidence of excessive overheating will void your warranty. As well, a large portion of sawmill waste is chemically treated timber, which is illegal to burn in many areas. Salt drift wood and chemically treated fire logs also must not be burned in your wood fire.

WARNING

Ensure that curtains, blinds and drapes cannot extend to or anywhere near the fire as this could cause an extremely dangerous operating condition.

These must be secured by any means possible.

Examples not limited to :

If a window or door is opened, the wind/breeze could cause them to move.

Physical movement by an adolescent child.

WARNING: THE APPLIANCE AND FLUE-SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. UNIT FLUEING REQUIRES A MINIMUM OF 50 MM CLEARANCE TO COMBUSTIBLES.

WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY. I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING 'TESTED TO AS/NZS 4013'.

ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013.

CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE.

CAUTION: CRACKED AND BROKEN COMPONENTS, e.g. GLASS PANELS OR FIREBRICKS & BAFFLE BRICKS, ETC. MAY RENDER THE INSTALLATION UNSAFE.

WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE.

WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING.

WARNING: DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES.

WARNING: DO NOT USE AS AN OPEN FIRE OR OPERATE WITH THE DOOR OPEN.

WARNING: OPEN AIR SLIDE CONTROL BEFORE OPENING FIRE DOOR.

CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS

CAUTION: THE USE OF SOME TYPES PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE HAZARDOUS

CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED WITH CRACKED GLASS

installation

UNIT DIMENSIONS

Dimensions

The outside dimensions of the Mansfield L850B ST including the Reduced Clearance Box is as follows:

  • Width = 1073 mm
  • Depth = 499 mm
  • Height = 927 mm

Height of optional Base Framing Kit = 300mm

Note: Base is non-combustible and needs assembly

Height of reduced clearance box off the ground should be a minimum of 300mm and supported by a non-combustible stand able to support 332kg.

Note: Depth is determined by the position of the nailing strips and thickness of non-combustible finished wall material.

Flue

The flue must be a Regency triple skin type with approved cowl and must extend a minimum of 4.6 metres above the top of the floor protector.

Optional Ducting

2 x Optional fan forced ducting kit are available, using 150 mm ducting to a max run of 9 metres to channel warm air to another location.

REDUCED CLEARANCE BOX DIMENSIONS
1073

499 927

WOOD FIREPLACE SPECIFICS AND MINIMUM CLEARANCES

Framing and Finishing Guide

Finishing material must be flush with the outer edge of Clean Edge Finish – see page on Installation Instructions.

Finishing material must not protrude past the outer edge of Clean Edge Finish – see on Installation Instructions.

All walls of the enclosure must be a minimum of 9 mm non-combustible material compliant with AS1530-1 and AS1530-3.

Please note: when selecting non-combustible material, wall temperatures can exceed 250°C. Clean edge trim standoffs top and both sides are set at 22mm. Leave a minimum 10mm gap from bottom of clean edge trim to non combustible material to allow for expansion and contraction.

*Enclosure Depth = 569 mm – total thickness of finishing material on each side of the heater.

*Maximum finishing material thickness is 15 mm on the front & back face of the enclosure to ensure a minimum air gap of 20 mm between the face of the reduced clearance box and the back face of the finishing material on each side of the heater.

Enclosure depth is noted with nailing strips (top & sides) set for the correct total thickness of non-combustible finished wall material.

Ceiling inside of the cavity is to be 2.4 metres minimum.

Ceiling in the room is to be 2.4 metres minimum.

Ceiling can be of combustible materials.

Enclosure Width = 1580 mm minimum

Enclosure volume is critical and must not be reduced.

The enclosure must be fitted with an air ventilation grill centrally located below one of the door openings and centrally located above one of the door openings, as high as possible. Minimum 1080mm above top of fuel loading door. Both grills must be installed as per diagram below.

Floor Protector Requirements

Floor protector needs to be 9mm thick non-combustible material, 1220mm wide and 300mm deep extending out from door on both sides. We do recommend that your non-combustible floor protector extends 900mm in front of the unit. This allows the floor to be protected when the door is fully open in case of ember drop.

The appliance must be installed on a non-combustible stand 300mm above the floor protector.

Framing

When constructing the framework for the enclosure :

  • All framing must be non-combustible material
  • There must be a 25 mm clearance between any vertical or horizontal stud and the body of the reduced clearance box, to the sides and above the reduced clearance box.

TOP VIEW Floor Protector 1580mm 300mm 700mm Enclosure Depth (see above) 1150mm 300mm 700mm 1220mm 250mm min. from either side of appliance to outer perimeter of enclosure Fireplace Enclosure Combustible Wall There and th reduce

UPPER VENTILATION GRILL REQUIRED MINIMUM OPEN AREA OF 8000mm2 MINIMUM OF 1080mm ABOVE FUEL LOADING DOOR ON ONE SIDEO ONLY FRONT VIEW BOTTOM OF VENT TO BE 50 MM MIN ABOVE FLOOR PRO- TECTOR LOWER VENTILATION GRILL REQUIRED MINIMUM OPEN AREA OF 8000mm2 ON ONE SIDEO ONLY CEILING INSIDE ENCLOS 2.4m M ABOVE FL PROTECT

NON COMBUSTIBLE FACING MATERIAL & NON COMBUSTIBLE FRAME MUST BE USED ON ENTIRE ENCLOSURE
NEW OR EXISTING CEILING 50mm CLEARANCE IS REQUIRED TO FLUEING WHEN PASSING THRU COMBUSTIBLE CEILING. 9mm FLOOR PROTECTOR THICKNESS EXTENDING 300MM (BOTH SIDES OF FIREPLACE)

FLUE CLEARANCE TO COMBUSTIBLES

Note: The minimum flue clearance to combustibles for the triple skin flue as it passes through ceilings, any enclosure, roof space, etc. is 50 mm. Minimum 50mm clearance to combustibles as it passes through floors, living space and ceilings. Combustible Ceiling 2nd Floor Combustible Enclosure of Chimney when passing through 2nd Floor Combustible Ceiling Minimum 50mm clearance to combustibles as it passes through floors, living space and ceilings.

  1. Ventilation grills = 2 grills, 1 below & 1 above fuel loading doors. Grills can be on the same or opposite sides of the enclosure. Require minimum 8000mm² of open area for each grill.
  2. Require unit to be raised minimum of 300mm from floor protector.
  3. Non-combustible board and steel framing is required for the entire enclosure however the ceiling may be of combustible material - see page 9 for minimum ceiling height.
  4. Clearances to combustibles for triple skin flue as it passes through ceiling, living spaces = 50mm.
  5. Non-combustible with walls of enclosure to be 9mm thick minimum.

OPTIONAL BASE FRAME

1077 300

493

Regency Mansfield L850B ST - OPTIONAL BASE FRAME - 3

natural_image Empty rectangular frame with dashed border and corner handles, no text or symbols present

Technical diagram of a structural frame assembly with numbered components and dashed alignment lines

CONSTRUCTING YOUR OWN BASE FRAME

WHEN BUILDING YOUR OWN BASE FRAME OR PEDESTAL BASE PLEASE ENSURE THE FOLLOWING CONDITIONS ARE MET:

  1. MINIMUM HEIGHT OF THE BASE FRAME IS 300MM FROM THE FLOOR PROTECTOR TO THE UNDERSIDE OF THE REDUCED CLEARANCE BOX. IF BASE FRAME DOES NOT SIT ON THE SAME LEVEL OF THE FLOOR PROTECTOR, THEN THE FRAME NEEDS TO BE MADE TALLER TO ENSURE THE 300MM CLEARANCE IS MET. (SEE PAGE 9).
  2. ENSURE THE CENTRE OF THE BASE IS HOLLOW TO ALLOW THE HOOK-UP OF THE OPTIONAL OUTSIDE AIR KIT.
  3. ENSURE THE BASE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS
  4. ENSURE THE BASE CAN WITHSTAND THE WEIGHT OF AT LEAST 332KG PLUS.
  5. ENSURE THE FLOOR BENEATH THE BASE CAN WITHSTAND AT LEAST 332KG PLUS.
  6. THE BASE CANNOT BE OF SOLID CONSTRUCTION. COOLING AIR MUST BE ALLOWED TO FLOW UNOBSTRUCTED ACROSS THE BOTTOM OF THE REDUCED CLEARANCE BOX.

FLUE REQUIREMENTS

6000 3000 or less More than 3000 600 min. 3000 1000 min. if clear within 6000 of flue top Increase as necessary lntil nothing within 6000 of flue top Any nearby structure

3000 or less More than 3000 600 min. 3000 increase from 1000 min. until clear within 3000 of flue top

THE FLUE PIPE SHALL EXTEND NOT LESS THAN 4.6 M ABOVE THE TOP OF THE FLOOR PROTECTOR.

NOTE: INSTALLATION MUST BE CARRIED OUT BY A LICENSED INSTALLER IN ACCORDANCE WITH AS/NZS 2918:2018

FLUE REQUIREMENTS

Roofing Batten Ceiling Ceiling plate Gap 25 Flue pipe casing Flashing Gap 25 Gap 50 Gap 50 175 3 x ∅five from active flue to heat sensitive surface

Typical Example of a Sloped Ceiling Penetration

Flue-pipe casing(s) See Clause 4.8 Flashing Heat-sensitive roof 25 25 25 50 Flue pipe Batten Rafter

Example of Roof Penetration

installation

INSTALLATION INSTRUCTIONS UNIT PREPARATION/FRAMING

BEFORE INSTALLING ENSURE THE FOLLOWING:

READ THE ENTIRE MANUAL

EVALUATE THE LOCATION OF YOUR FIREPLACE AND LOCATION OF OPTIONAL COMPONENTS SUCH AS FAN, OUTSIDE AIR AND FINISH TRIMS.

DETERMINE THE THICKNESS OF YOUR DESIRED NON-COMBUSTIBLE FINISHING MATERIALS INCLUDING THE REQUIRED NON-COMBUSTIBLE BOARD. THIS PREDETERMINED THICKNESS WILL DICTATETHE ENCLOSURE DEPTH, POSITION OF THE NAILING STRIPS, FRAMING AND OVERALL FINAL LOOK OF YOUR FIREPLACE.

The unit comes standard with nailing strips and clean edge frame installed on both sides. The clean edge frame comes with 20 mm standoff brackets on the top edge plus left & right hand sides (not on bottom) to ensure clearance to finished wall material.

Clean edge frame: MAXIMUM THICKNESS OF FINISHING MATERIAL: 15MM

  1. Determine the location of the fireplace, flueing location and locations of the options such as the Fan Kit and outside air.
  2. Construct your base frame. Please see BASE FRAME instructions on page 11. The base frame is required TO RAISE THE UNIT in order to meet the 300mm clearance to the floor protector.

Base Frame

  1. Install the floor protector (see page on Installation instructions).

  2. Frame out side walls only of the fireplace enclosure. DO NOT FRAME FRONT OR BACK WALL. All framing for the walls of the enclosure need to be constructed using steel studs. Please refer to page on clearances for clearances and enclosure depth.

  3. Install the base frame and secure to the floor / floor protector ensuring the frame is level.

  4. Due to the large capacity of the firebox, most homes (especially 'air tight' 5 or 6 Energy Star Rates homes) will require an external air supply to ensure that the fire receives sufficient combustion air. If using optional outside air kit please refer to the outside air kit in this manual. The optional air kit adapter must be installed prior to the unit being positioned on to the base frame. Install flexible duct from air kit adapter to external air source.

  5. Install the fireplace on the base frame. Secure fireplace to the base frame

INSTALLATION INSTRUCTIONS UNIT PREPARATION/FRAMING

  1. Frame out the front & back walls of the enclosure using steel studs - refer to pages of this manual for clearances. Leave a 5 mm gap from the side of the Reduced Clearance Bos to any horizontal or vertical steel stud to allow for expansion.
  2. You are now ready to install the flueing.

Please refer to Flue requirements in this manual then install your flue system.

  1. After the flue has been installed, complete the install of your optional kits such as fan/heat distribution kit(s) and/or outside air kit.

When cutting a rectangular opening in the finishing material to fit around the clean edge :

Width

The width of the opening must include the actual width of the clean edge finish (outside edge to outside edge) plus allow for the 20 mm stand-offs on the left & right sides

Height

The height of the opening must include the actual height of the clean edge finish (outside edge to outside edge) plus allow for the 20 mm stand-offs on the top edge plus a 5 mm air gap along the bottom edge

The actual position of the opening in the facing material will depend on site conditions, finished floor level, the height of the reduced clearance box off floor protector level, etc. We suggest, to avoid errors, that these measurements be taken when the heater is actually installed in its final location.

Framing Width = Fireplace Width (569mm) less 2 x Cladding Thickness
CLADDING FRAMING WIDTH CLADDING FIREPLACE WIDTH - 569mm

INSTALLATION INSTRUCTIONS UNIT PREPARATION/FRAMING

  1. Install the nailing strips. The unit comes with eight nailing strips. The top, left and right side are all the same and the bottom one is the smaller piece. Install the top and side nailing strips with the slotted side on the unit. The left and right nailing strips should NOT be touching the floor. Secure with the screws provided. Install the bottom small nailing strip and secure to the left and right vertical ones. DO NOT TIGHTEN SCREWS on the top, left and right nailing strips.

Regency Mansfield L850B ST - INSTALLATION INSTRUCTIONS UNIT PREPARATION/FRAMING - 1

natural_image Metal panel with circular features and a red arrow pointing to a small circular feature (no text or symbols visible)

Nailing strip installed with slotted side on unit. The slot allows the movement of the nailing strip to be adjusted depending upon thickness of finish material.

Smaller Bottom Nailing Strip

Adjustable nailing strips - secure to steel framing Adjustable nailing strip- secure to steel framing Nailing strip- secure to steel framing ial

Bottom nailing strip-secure to left and right vertical nailing flanges

Note: Keep left and right nailing strips off the floor to allow for adjust ability

INSTALLATION INSTRUCTIONS UNIT PREPARATION / FRAMING & WALL FINISHING

IMPORTANT: DO NOT BEGIN FRAMING UNTIL THIS STEP HAS BEEN COMPLETED.

  1. Set the Adjustable Nailing Strips in position by using a piece of the non-combustible cladding and finishing material as a gauge.
  2. Hold the piece of cladding and finishing material flush with the front edge of the clean edge finish.
  3. Slide the Adjustable Nailing Strips so they are tight against the back of the non-combustible cladding material and tighten the screws to lock the angles in place.
  4. Repeat on the other side of the Mansfield fireplace.

Clean Edge Frame (Comes with Unit) Nailing Strips adjusted forward to thickness of finishing material Finish Material Finish material to this edge Nailing Strips pulled forward to butt up against backside of finish material

Nailing Strips pulled forward against the backside of the finished wall material to provide backing and support Finish material to this edge when using the Clean Edge Frame

  1. Install the steel framing: Both walls require construction of non-combustible materials including the framing. Steel stud framing must be used. Install the left and right vertical steel frame and secure to the nailing strips. Position the steel frame behind the nailing strip. Install the top horizontal steel frame and secure to the top nailing strip.

Steel framing installed Secure nailing flanges to steel framing

  1. Finish constructing the remainder of the front wall using steel framing. Ensure the framing is level and plumb and there is enough framing to secure the required non-combustible finishing material.
  2. Install the non-combustible finishing material. Ensure there are no seams on the top and sides as these areas get extremely hot. Having no seams on the top and side will prevent cracking. Use only high heat non-combustible finishing material.
  3. ENSURE ALL ADHESIVES / GLUES ETC. ARE HIGH HEAT RESISTANT. ALLOW BONDING AGENTS TO CURE PROPERLY BEFORE FIRING UNIT.

FLUE AND CHIMNEY REQUIREMENTS

PLEASE READ AND REFER TO INSTALLATION INSTRUCTIONS UNIT PREPARATION ON PAGE 16

Top of Unit prior to installation of the flue.

NOTE: INSTALL REGENCY APPROVED FLUE KIT ONLY
Regency Mansfield L850B ST - PLEASE READ AND REFER TO INSTALLATION INSTRUCTIONS UNIT PREPARATION ON PAGE 16 - 1

natural_image Technical diagram of a mechanical component with three circular features and mounting brackets (no text or symbols)
  1. Insert the 7" stainless steel starter piece. Note the crimped end is down (into unit).

Regency Mansfield L850B ST - PLEASE READ AND REFER TO INSTALLATION INSTRUCTIONS UNIT PREPARATION ON PAGE 16 - 2

natural_image Top-down view of a ceiling-mounted cylindrical device with a circular opening, mounted on a white platform (no visible text or symbols)
  1. Insert the 7" stainless steel active flue. Note: crimped end is down. Must connect active pipe using stainless steel rivets or self drilling screws. 2 for each join.

Regency Mansfield L850B ST - PLEASE READ AND REFER TO INSTALLATION INSTRUCTIONS UNIT PREPARATION ON PAGE 16 - 3

natural_image Exterior view of a modern office building (no signage)
  1. The first length of 9" / 11" galvanised flue is fitted with air cooling brackets.

Regency Mansfield L850B ST - PLEASE READ AND REFER TO INSTALLATION INSTRUCTIONS UNIT PREPARATION ON PAGE 16 - 4

natural_image Close-up of a metallic mechanical component with ribbed texture and metal brackets, no visible text or symbols
  1. Insert the 9" & 11" galvanized flue skin fitted with aircooling bracket. Note: Crimped end of outer flue faces upwards.

Regency Mansfield L850B ST - PLEASE READ AND REFER TO INSTALLATION INSTRUCTIONS UNIT PREPARATION ON PAGE 16 - 5

natural_image Close-up of a metallic cylindrical device with a reflective top, mounted on a workbench (no visible text or symbols)
  1. Air cooled bracket and pipe fitted to unit

Regency Mansfield L850B ST - PLEASE READ AND REFER TO INSTALLATION INSTRUCTIONS UNIT PREPARATION ON PAGE 16 - 6

natural_image Close-up of a metallic cylindrical component pressing into a circular opening, with no visible text or symbols.
  1. The final length of 9" / 11" galvanized flue pipe has ventilation slots at the top where it meets the cowl - to allow heat to escape.

Note: Ventilation at top of outer flue where it meets cowl – must be vented to allow heat escape.

Note: 9" skin will be shorter than 11" at top – this is fine as allows 9" to vent into outer and cowl.

Regency Mansfield L850B ST - PLEASE READ AND REFER TO INSTALLATION INSTRUCTIONS UNIT PREPARATION ON PAGE 16 - 7

natural_image Exterior view of a modern office building (no signage)

At this stage of the installation the unit is installed with the flue system and any optional kits. The next step is to install and set the nailing strips in the correct position to accommodate the front wall framing and finishing.

OPTIONAL FAN KIT INSTALLATION

LISTINGS AND CODE APPROVALS

This Fan Kit has been approved for use with Mansfield L850B ST.

Check with your local building code agency before you begin your installation to ensure compliance with local codes, including the need for "permits" and follow-up inspections. If any problems are encountered regarding code approvals, or if you wish clarification on any of the instructions contained here, contact your local dealer.

Ceiling Register Wall Register Ceiling Register Wall Register Floor Register

Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of bends to a minimum. Maximum duct length is 9.0m. The Fan Kit 946-591 does not contain any flexible duct. A separate Flex Kit is required 946-596. This Flex Kit contains one length of 4.5 metres of flex duct. If 9.0 metres of flex ducting is required you will need to purchase an additional Flex Kit.

Item No.Description No Description
1 240VFan Assembly7 Aluminum Flex 4.5m Long x 150 mm Round Diameter
2Duct Flange-Fan End
3Adapter Round to Oval8 Duct Flange -Heater End
4 AngleBracket 9Sidewall Grill
5Junction Box10 Cable Clamp
6Wall Adapter Plate

GENERAL INFORMATION

The Fan Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fireplace.

Important Installation Notes

1) The appliance installation must conform with local codes and installation codes.
2) The appliance when installed, must be electrically grounded in accordance with local codes.

3) This kit is tested and safe when installed in accordance with this installation manual. Please read all instructions before starting installation and follow all instructions carefully during installation.

4) Installation of this kit must be performed by a qualified person.

5) The Fan Kit must be installed only as specified. Any modifications of the kit or components will void the warranty and may cause a fire hazard.

6) Plan the location of the fireplace and the warm air duct runs, see diagram 1 as a guide for possible duct runs and locations.

NOTE: Airflow through the duct system is affected by the duct length and number of bends. Keep the length and bends to a minimum to maximize performance.

MINIMUM FRAMING CLEARANCES

* Wall studs must be 407mm on centre for mounting fan housing.
* Fan Housing: Maintain a (6mm minimum) clearance from fan housing to combustible material.
* Wall Registers must be 102mm above floor and / or 102mm below ceiling.

1) Determine the location of the air register/fan housing assembly. Cut a 121mm x 406mm hole between framing members (wall studs or floor joists). Maintain a 6mm clearance from fan housing to combustible material. See Framing Clearances section.

Minimum Fan Duct Clearances

The fan ducting requires a minimum of 25 mm clearance to combustibles.

Exploded view diagram of a mechanical device with numbered components for identification

Wall Register Wall Register Minimum 102 mm from ceiling

Minimum 102 mm from floor

NOTE: Installation of Fan Kit should be done prior to installation of the wall.

2) Mount and secure the fan housing assembly to framing. The mounting brackets are preset so that the front of the fan housing will protrude 12.7 mm out of the wall so that the front face will be flush with finished wall etc. See Diagram 2.
3) Install the flexible duct. Secure the duct to the duct collar on the unit and the fan housing with 3 screws per end.

Minimum 45 mm Fan Housing Adjustable Mounting Bracket Finished Surface Diagram 1: Front View

Finished Surface 45 x 90 mm Framing 12.7 mm Front of Fan Housing Adjustable Brackets for different wall/floor thickness.

Diagram 2: Side View - Secure fan housing to minimum 45mm framing.

Flexible Air Duct: Attach the 152.4 mm round air duct (supplied) to the fireplace collar and run the duct to the fan housing. Attach the round-to-oval adapter to the fan housing and the flex duct to the adapter.

Air Duct Round to Oval Adapter Fan Housing Secure with 3 Screws and Aluminum Duct Tape at Unit

4) Install the On/Off switch in a convenient location. This switch controls the fan operation. NOTE: Variable speed or Rotary 3 speed switch (not supplied) can be fitted.
5) Wire up the fan, wall switch and power supply per local codes. See wiring diagram as reference. *Electrician to supply wiring
6) Screw fan junction box to the fan housing.
7) Screw the Wall Adapter Plate and Grill to the Fan Housing. See Diagram 4.

Ground screw hole Fan Housing Finished Surface Wall Adapter Plate Grill Diagram 4

8) Remove the knockout on the top of the unit.
Regency Mansfield L850B ST - Minimum Fan Duct Clearances - 7

natural_image Close-up of a metallic mechanical component with a circular opening and an arrow pointing to a feature (no visible text or symbols)

9) On the top of the unit, bend the 3 tabs so that they are pointed upwards. Insert the Duct collar. Secure the collar to the 3 tabs with screws.

Duct collar secured with screws

10) The fan duct is now ready to be attached to the unit. Slide the ducting over the collar and secure with screws.

Regency Mansfield L850B ST - Minimum Fan Duct Clearances - 9

natural_image Close-up of a metal coiled component being adjusted by a tool, no visible text or symbols

11) Final step is to double check the fan ducting connections at both the unit and fan. Next ensure there is a minimum of 25mm clearance to combustibles, Strap and secure the fan duct. Double check the operation of the fan and all electrical work is completed.

FAN DUCT EXTENSION KIT

  1. Attach the connecting collar to the duct that came with the duct kit. Use the screws provided.

Regency Mansfield L850B ST - FAN DUCT EXTENSION KIT - 1

natural_image Close-up of a hand operating a large metallic industrial hose with coiled tubing (no visible text or symbols)
  1. Attach the 4.5m duct within this kit to the connecting collar on the opposite end with the screws provided. Extend the flex to the desired length.

Regency Mansfield L850B ST - FAN DUCT EXTENSION KIT - 2

natural_image Close-up of a hand operating a metallic cylindrical tool with threaded end (no visible text or symbols)

WIRING DIAGRAM

ON/OFF Switch 240V-50Hz Brown (Hot) Blue (Neutral) (Earth) Earth Wire Brown Blue Earth CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation Green Blue-Neutral Brown-High Red-Low Red: Low Speed Fan Black High Speed Heat Zone Unit Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.

Alternate Switches: May use the following. Check with local authorities and electrician.

CLIPSAL 203 2E45 OUD - Dimmer

CLIPSAL 2031 VF3CSF - 3 Speed

Installation of wiring and switching must be carried out by a qualified electrician

Note: When using the supplied On / Off Switch or Dimmer (not supplied) remove the Red wire at the motor terminal or insulate the bare end of the Red wire (this connection is not used).

OPTIONAL OUTSIDE AIR KIT INSTALLATION

Due to the large capacity of the firebox, most homes (especially 'air tight' 5 or 6 Energy Star Rated homes) will require an external air supply to ensure that the fire receives enough combustion air. The Outside Air Kit cannot be fitted after the fireplace has been installed.

Provision will need to be made to extend the flex ducting for the Outside Air Kit to an external vent located through a wall, eaves or roof flume (not supplied).

When installing the outside air kit please ensure your pedestal base the unit sits on is hollow in the centre. The outside adapter attaches to the bottom of the unit. It is recommended not to down-size the outside air ducting.

  1. Evaluate your base frame. Ensure there is adequate space to allow the hook up of the adapter beneath the reduced clearance box.
  2. Gently lay the unit on its back to access the bottom. Remove the cover plate located on the bottom of the reduced clearance box accessing the primary air control.

Regency Mansfield L850B ST - OPTIONAL OUTSIDE AIR KIT INSTALLATION - 1

natural_image Close-up of a square metallic object with red circular markers and a bright central spot, no visible text or symbols.

Remove screws and Cover Plate

Regency Mansfield L850B ST - OPTIONAL OUTSIDE AIR KIT INSTALLATION - 2

natural_image Close-up of a metallic circular component with a central radial feature and evenly spaced slots, no visible text or symbols.

View with Cover Plate removed and unit adapter installed - primary air control now visible.

  1. Install the adapter ensuring it is centred on the primary air opening. Secure in place with the provided screws.

NOTE: The larger diameter end requires to be sitting below the unit. Small diameter end will insert into the bottom of the Reduced Clearance Box.

Regency Mansfield L850B ST - OPTIONAL OUTSIDE AIR KIT INSTALLATION - 3

natural_image Close-up of a black cylindrical mechanical part with a red arrow pointing to it, placed on a surface (no text or symbols visible)

Large Diameter End to be Below Unit

  1. Stretch the 150 mm diameter flex duct out to the distance required. Attach the 150 mm diameter flex duct to the large diameter part that is protruding below the bottom of the unit. Use the screws provided.

Regency Mansfield L850B ST - OPTIONAL OUTSIDE AIR KIT INSTALLATION - 4

natural_image Close-up of a metal pipe wrapped in coiled black plastic, with tiled wall background (no visible text or symbols)
  1. Cut a hole on your pre-determined outside wall to allow the fresh outside air hood to be installed. Install and secure the outside air hood. Seal around the flange to ensure tight seal against exterior of home. Join the 150 mm diameter flex duct from the unit adapter to the fresh air hood on the inside of the wall.

Regency Mansfield L850B ST - OPTIONAL OUTSIDE AIR KIT INSTALLATION - 5

natural_image Close-up of a hand using a power tool to cut a metallic cylindrical pipe (no visible text or symbols)

installation

FIREBRICK INSTALLATION

Some firebricks are not in place at time of delivery to prevent damage.

Place 2 right and 2 left vertical bricks at sides of fireplace first.

Then place 2 bottom bricks in position.

3 x Baffle Bricks need to be placed in position at top of firebox.

Firebricks are included as an integral part of the unit and not only enhance operating performance hence compliance of the unit but also to extend the life of your firebox.

Bricks must be replaced if damaged in any way in order not to Void the Warranty

Regency Mansfield L850B ST - FIREBRICK INSTALLATION - 1

natural_image 3D rendering of a U-shaped mechanical component with two rectangular bases and a central slot (no text or symbols)

APPLIANCE MAINTENANCE

CREOSOTE

When wood is burned slowly, it produces tar and other organic vapours, which when combined with moisture, form creosote. The creosote vapours condense in the relatively cool flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote can result in an extremely hot fire.

WARNING: Things to remember in case of a flue fire:

  1. Close both door & the air slide.

  2. CALL THE FIRE BRIGADE.

Ways to Prevent and Keep Unit Free of Creosote

1) Burn heater with the air slide wide open for about 10-15 minutes every morning during burning season.
2) Burn heater with air slide control wide open for about 10 - 15 minutes every time you apply fresh wood. This allows the wood to achieve the charcoal stage faster and burns up any unburned gas vapours which might otherwise be deposited within the system.
3) Only burn seasoned hardwood! Avoid burning wet or green wood. Seasoned wood has been dried at least one year.
4) A small hot fire is preferable to a large smouldering one that can deposit creosote within the system.
5) The flue should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred.
6) Have flue system and unit cleaned by competent flue sweeps twice a year during the first year of use and at least once a year thereafter or when a significant layer of creosote has accumulated (3 mm) it should be removed to reduce the risk of a flue fire.

ASH REMOVAL

During constant use, ash should be removed every few days.

Safety Precautions

1) Do not allow ash to build up to the loading doors. Only remove ash when the fire has died down. Even then, expect to find a few hot embers.
2) The firebricks are brittle and can be damaged if logs that are too large or forced/thrown in.
3) Shovel out the ash into an appropriate container for removing ashes. The ash can still have hot embers so dispose of carefully. A large metal bucket designed for ash removal is recommended. It should come with a tight fitting lid and wire handle for carrying.
4) Leave about 25mm of ash in the firebox. It will make it easier to build and maintain a fire. The hot coals tend to nestle into the ash and glow, adding more heat to the fuel and reflecting the heat back into the fire.

GLASS INSTALLATION

ALWAYS ENSURE APPROVED PERSONAL PROTECTIVE EQUIPMENT IS USED WHEN HANDLING DAMAGED GLASS

  1. Remove the door from the heater by lifting it up off hinge pins.
  2. Remove the top glass retainer.
  3. Loosen the bolts on the bottom retainer.
  4. Loosen screws on the left and right side retainers.
  5. Remove the glass carefully and keep it aside.
  6. Install a new glass seal onto the window frame.
  7. Install the new glass.
  8. Reverse steps 1-4 to reassemble the unit.

Replacement Glass Part Number: 2510221
Side Retainer Top Retainer Side Retainer Bottom Retainer

MAINTENANCE

It is very important to carefully maintain your heater, including burning seasoned wood and maintaining a clean heater and flue system. Have the flue cleaned before the burning season and as necessary during the season, as creosote deposits may build up rapidly. Moving parts of your heater require no lubrication. The integrity of all heater parts including fire bricks, air tubes, door rope seals, and door glass seal is imperative for the correct operation and longevity of your Regency Wood heater. They should be inspected on a regular basis and replaced if they show any signs of undue wear or damage. Failure of any of these components can damage the heater and void warranty.

GLASS MAINTENANCE

Your Regency heater is supplied with Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only, and follow our step-by-step instructions for replacement.

Allow the heater to cool down before cleaning the glass, do not clean the glass when it is hot and do not use abrasive cleaners as both will damage the glass.

DOOR LATCH ADJUSTMENT

The door latch may require adjustment as the door rope seal material compresses over time.

Follow the steps below to allow the latch to be moved closer to the door frame, causing a tighter seal.

1) Loosen Door Latch securing bolts.
2) Move door latch back towards the firebox by a few millimetres to create a firmer door seal.
3) Retighten latch bolts.

operating instructions

OPERATING INSTRUCTIONS

With your unit now correctly installed and safety inspected by your local authority, you are now ready to start a fire. Before establishing your first fire, it is important that you fully understand the operation of your air slide control.

WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE.

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING.

WARNING: DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES. CAUTION: THIS APPLIANCE MUST BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS.

WARNING: OPEN AIR CONTROL (AND DAMPER WHEN FITTED) BEFORE OPENING FIRING DOOR.

CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS.

CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS.

CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE HAZARDOUS.

WARNING: OPEN THE AIR SLIDE BEFORE OPENING THE DOOR.

For safety reasons and in order to avoid over firing of your unit do not burn your fire with the door open or ajar.

AIR SLIDE CONTROL

Both the primary and air wash drafts are controlled by the air slide control located below the glass door. To increase your draft - pull right to open, and to decrease - push left. All units have a secondary draft system that continually allows combustion air to the induction ports at the top of the firebox.

Regency Mansfield L850B ST - AIR SLIDE CONTROL - 1

natural_image Technical line drawing of a right-open mechanical assembly with diagonal braces and a cylindrical component (no text or symbols)

left-closed

WARNING: To build a fire in ignorance or to disregard the information contained in this section can cause serious permanent damage to the unit and void your warranty!!

FUEL REQUIREMENTS

BURN ONLY HARDWOOD TIMBER THAT HAS BEEN SEASONED AND THE MOISTURE CONTENT OF THE LESS THAN 20%.

FRESHLY CUT WOOD REQUIRES AT LEAST 12-18 MONTHS TO BE READY FOR USE.

USING SEASONED TIMBER WITH PROPER MOISTURE CONTENT WILL ENSURE DRAFT, CLEAN GLASS, EFFICIENCY AND HEAT OUTPUTS.

CAUTION: BURN UNTREATED AIR DRIED SEASONED HARDWOODS ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVATIVES, METAL FOILS, COAL, PLASTIC, GARBAGE, SULPHUR COAL, BRIQUETTES OR OIL WILL DAMAGE THE FIRE AND ATMOSPHERE AND VOID THE WARRANTY.

"This wood heater is designed to burn natural hardwood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as compared to green or freshly cut hardwoods."

DO NOT BURN

(WILL VOID WARRANTY)

  • Treated wood
  • Tea Tree
  • Oil based woods
  • Coal
  • Cardboard
  • Solvents
  • Colored Paper
    • Household Waste

SAVE THESE INSTRUCTIONS

WOOD STORAGE

Store wood under cover, such as in a shed, or covered with a tarp, plastic, tar paper, sheets of scrap plywood, etc., as uncovered wood can absorb water from rain or snow, delaying the seasoning process.

WARNING: Do not over-fire this unit and always open the door slowly when reloading

LIGHTING THE APPLIANCE AND THE FIRST FEW FIRES

operating instructions

When your installation is completed and inspected you are ready for your first fire.

1) Split wood into 3 stacks: Kindling, Start Up, (larger pieces than kindling) and firewood.

2) Open air slide control fully.

3) Open firebox door and build a small fire using paper and dry kindling on the firebrick base. Secure door on the firebox and wait a few minutes for a good updraft in the flue to establish the fire.

Add start up wood and spread across the unit. It is important to create airspaces within the pieces of start up wood for proper ignition and clean combustion. (Leaving the door slightly open will help your fire start more rapidly.

CAUTION: Never leave unit unattended if door is left open. This procedure is for fire start-up only, as unit may overheat if door is left open for too long.

4) With the air slide still in the fully open position add two or three seasoned logs to your fire. Form a trench in the ash bed to allow air to reach the rear of the firebox prior to closing the door.

5) After about 45 minutes, when your wood has begun to burn strongly, adjust your air slide control down to keep the fire at a moderate level.

WARNING: Never build a roaring fire in a cold heater. Always warm your heater up slowly!

6) Once a bed of coals has been established on the base of the firebox, you may adjust the air slide control to a lower setting to operate the unit at its most efficient mode.

7) During the first few fires, keep the combustion rate at a moderate level and avoid a large fire. Only after 5 or 6 such fires can you operate the heater at its maximum setting, and only after the metal has been warmed.

8) For the first few days, the heater will give off an odour from the paint. This is to be expected as the high temperature paint cures. Windows and/or doors should be left open to provide adequate ventilation while this temporary condition exists. Burning the heater at a very high temperature the first few times may damage the paint. Burn fires at a moderate level the first few days.

9) Do not place anything on the heater top during the curing process. This may result in damage to your paint finish.

10) During the first few days it may be more difficult to start the fire. As you dry out the firebrick and your masonry flue, the draft will increase.

(4.1) For those units installed at higher elevations or into sub-standard masonry fireplaces, drafting problems may occur. Consult an experienced dealer or mason on methods of increasing your draft.

12) Some cracking and popping noises may be experienced during the heating up process. These noises will be minimal when your unit reaches temperature.

13) Before opening your door to reload, open air slide fully for approximately 10 to 15 seconds until fire has been re-established. This will minimize any smoking. Open door slowly.

14) All fuel burning appliances consume oxygen during operation. It is important that you supply a source of fresh air to your unit while burning. A slightly opened window is sufficient for the purpose. If you also have an open fireplace in your home, a downdraft may be created by your Regency Heater causing a draft down your flue. If this occurs, slightly open a window near your unit.

CAUTION: If the body of your unit, flue baffle or any part of the flue starts to glow, you are over firing. Stop loading fuel immediately and close the draft control until the glow has completely subsided.

15) If you have been burning your heater on a low draft, use caution when opening the door. After opening the air slide, open the door a crack, and allow the fire to adjust before fully opening the door.

16) The controls of your unit or the air supply passages should not be altered to increase firing for any reason.

17) If you burn the unit too slowly or at too low a setting your unit will not be operating as efficiently as it can. An easy rule of thumb says that if your glass is clean, then your flue is clean and your exhaust is clean. Burn the heater hot enough to keep your glass clean and you won't need to clean your flue as often.

DO NOT OVERLOAD FIREPLACE OR COVER THE SECONDARY TUBES. ENSURE COALS / FUEL ARE BEHIND LOG RETAINER DO NOT OPEN DOOR WITH A ROARING FIRE OR WITH AIR CONTROL IN LOW POSITION. WHEN REFUELING ALWAYS ENSURE AIR CONTROL IS IN OPEN POSITION.

operating instructions TROUBLESHOOTING

SymptomPossible CauseSolution
Fire will not start or starts slowlyThe combustion air control is closed, or insufficient combustion air is reaching the fire.Ensure that the air control is open and that the air inlet is free from debris. If necessary crack open the fireplace door until the fire is started.
Wet or insufficient kindling was used to try to start the fireUse drier kindling and paper if necessary to start the fire. The initial burn helps to warm the flue and establish a proper draft.
Trying to burn wet “fuel” wood will slow down the startUse drier “fuel” wood for the fire, and allow more air space to start the fire. Wood should have a moisture content of 15-20% for best results. Use more kindling to dry the “fuel” wood.
A negative air pressure in the home which can reverse or impede the natural flow of flue gasses.Crack open a door or window, and turn off all exhaust devices. Typically increasing flue height will help to increase fireplace draw.
A dirty or blocked flue or blocked air inlets can reverse or impede the natural flow of flue gasses.Inspect the flue and fireplace for buildup or blockage and as necessary have the flue and fireplace cleaned.
Dirty GlassThe air control may have been closed to soon, slowing down the burn of the fire, which will allow deposits to stick to the glassLeave the air control open longer, at least 10-15 minutes every time you insert fresh wood, to ensure the fire has reached optimum temperature and properly established a draft.
Burning wet wood will slow the burn of the fire, produce more smoke, and allow unburned fuel to stick to the glass.Use drier wood for the fire. Wood should have a moisture content of 15-20% for best results.
A dirty flue, or an improperly sized or installed vent, will impede the flow of flue gasses slowing down the fire and allowing unburned fuel to stick to the glass.Inspect the flue for buildup or blockage and to ensure that the proper size and configuration of venting was installed (refer to the Unit's manual) and as necessary have the flue cleaned, repaired, or replaced.
An inadequate supply of combustion air will slow the burn and allow deposits to stick to the glass.Ensure that air intakes are clean and clear of any debris. It may be necessary to install an outside air kit to provide adequate air supply.
Worn seals will change the airflow of the fireplace and can allow deposits to stick to the glass.Inspect and replace any worn seals to ensure proper airflow patterns within the unit.
SymptomPossible CauseSolution
Fire burning too fastThe door may have been left open, or the door latch may need adjustment.Ensure that the door is properly closed and that when latched that the latch holds the door closed. If necessary adjust the latch (refer to the manual).
Worn seals will change the airflow of the fireplace and can increase the speed of the burn by bypassing the air control system.Inspect and replace any worn seals to ensure proper airflow patterns within the unit.
The air slide control may have been left open, allowing the fire to burn fasterOnce the fireplace has reached optimum temperature, adjust the primary air control to maintain optimum burn.
An overly tall flue may create an excessive draft, which will increase the speed of the burn.Although heater pipe dampers are not recommended in today's EPA Certified units, it is possible to install a flue damper in the pipe at a height of 18" above the flue of the unit. This will restrict the flue gasses and help decrease the speed of the burn.
CAUTIONIf the body of your unit starts to glow, you are overfiring the unit. STOP loading fuel immediately and close the air slide control & both doors until the glow has completely subsided.

MAIN ASSEMBLY

1 251022Ceramic Glass (glass only)
2 371020A Bottom Bricks (2pcs)
3 371020B Side Bricks (2pcs)
4 371020C Top Bricks (left top & right top)
5 371020D Top Brick (middle top)
N/S 1560021Top, Left & Right Nailing Strips (6pcs)
N/S 1560022Bottom Nailing Strip (2pcs)
N/S 1638000Base Frame Kit*
N/S 1564007Deflector Hood
N/S 3720301P10 Glass Seal (2.3m)
N/S 156011050mm Finishing Trim with Box*
N/S = Not Shown * = optional accessory—not a spare part
1634200 30mm Finishing Trim with Box*
6 1639000Log Bar Support Assembly
3720101A 16mm Door Rope Seal
7 1562100Door Frame Assembly (no glass)
8 1562500Door Handle Assembly
9 1566000Door Hinge
10 1569000Adjustable Door Latch
11 1563200Air Slide Assembly
N/S 1560019Door Opening Tool
12 1633600Secondary Air Tube
13 1562400Glass Retaining Set
14 1634100Clean Edge Frame (with 20 mm standoffs)

Technical diagram of a modular device with numbered components, showing assembly and mounting layout.

parts list

# Part Description
1 910-169/P Replacement Fan Motor
2 946-001 Duct Flange
3 946-002 Round to Oval Adapter
4 946-007 Angle Bracket
5 946-004 Junction Box
6 946-005-AWT Wall Adapter Plate White
7 948-357 Adapter Round
8 946-093F Duct Mounting Plate
9 946-000 Duct Flange Collar
10 946-006 Side Grill White
11 904-687 Connector Clamp

Exploded view diagram of a refrigerator internal components with numbered labels

INSTALLATION OF APPLIANCE CHECKLIST

For future reference and to assist in any warranty claim please complete the following information.

In the unlikely event of a problem, contact your installer or dealer for assistance:

APPLIANCE WAS PURCHASED FROM

Name: ____

Address:

Telephone Number: ____

MODEL DETAILS

Date Installed: ____

Model Description: ____

Serial Number:

INSTALLED BY

Company Name: ____

License Number: ____

Plumber Name: ____

Address:

Telephone Number:

COMMISSIONING CHECKS (TO BE COMPLETED AND SIGNED)

Is flue system set up in accordance with AS2918

YES NO

Smoke and Spillage test completed

YES NO

Use of appliance and operation of controls explained

YES NO

Clearance to combustible materials checked

YES NO

Installers Signature: ____

Print Name: ____

Date:

Limited Warranty

FPI Fireplace Products International Ltd. ("the manufacturer") through its wholly owned subsidiary, Fireplace Products Australia Pty Ltd (for Australia and New Zealand customers) and sold under the Regency® brand of fireplace products (collectively referred to herein as "FPI"), extends this Limited Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.

Some conditions apply (see below).

The policy is not transferable, amendable or negotiable under any circumstances.

Wood ProductsComponent CoverageLabor Coverage
Components Covered15 years2 years1 yearWarranty(Years)
Welded Firebox Steel5
All Stainless Steel Components, Smoke Deflectors, Heat Shields etc.1
Air Tubes1
Airmate1
Door handle and latch assembly, all hardware1
Glass Thermal Breakage Only1
Steel Faceplates, Accessory Housings1
All Plating1
Ash Drawer, Heatshields, Pedestal1
All Baffles-Steel, Ceramic, Vermiculite1
All castings, firebox, surrounds, doors, panels etc.1
All Electrical, Fans, wiring, switches etc.√(Fan only)1
Glass - Crazing1
Catalyst Assembly (see below for specific details)6 Years Prorated3
Flue components1
FirebricksNilNil

After the original warranty coverage for any of the parts above have expired, any repair and/or replacement parts purchased by the consumer from FPI or through an accredited distributor or dealer will carry a ninety (90) day warranty (valid only with an original copy of the tax invoice). No labor coverage is included with any repair and/or replacement part.

Replacement parts are limited to one per warranty term. Airtube and baffle replacements are limited to one replacement per term.

Catalyst Assembly

IMPORTANT WARRANTY INFORMATION FOR UNITS WITH A CATALYTIC CONVERTER

FPI will replace, at no charge to the consumer, 'one' catalytic converter that ceases to function within three (3) years from the date of purchase by the original consumer, provided that the following conditions are met:

(1) The catalytic converter must not have been mechanically abused
(2) Only recommended fuels have been used in the appliance

If after three (3) years the catalytic converter fails to function, a prorated warranty will provide for replacement at the following fee schedule to be paid by the consumer*:

Year 4....\$90*

Year 5......\$100*

Year 6......\$110*

* Prices subject to change without notice. Conditions (1) and (2) above also apply for prorated warranty periods.

AFTER YEAR SIX (6), THE CONSUMER MUST PURCHASE ANY CATALYTIC CONVERTERS THAT NEED REPLACEMENT AT THE CURRENT RETAIL PRICE, AND WILL BE RESPONSIBLE FOR ANY LABOUR COSTS TO REMOVE AND/OR SERVICE. LABOR WILL ONLY BE COVERED ON THE CATALYTIC CONVERTER FOR THE FIRST THREE (3) YEARS.

Conditions:

Warranty protects against defect in manufacture or FPI factory assembled components only, unless herein specified otherwise. This warranty will only apply to those products which are acquired at the time of this warranty being effective. FPI will not be liable for any damage or loss that falls outside the scope of the warranty.

Any part(s) found to be defective during the warranty period as outlined above will be repaired or replaced at FPI's option through an accredited distributor, dealer or pre-approved and assigned agent provided that the defective part is returned to the distributor, dealer or agent for inspection if requested by FPI. Alternatively, FPI may at its own discretion fully discharge all of its obligations under the warranty by refunding the verified purchase price of the product to the original purchaser. The purchase price must be confirmed by an original copy of the tax invoice.

The authorised selling dealer, or an alternative authorised FPI dealer if pre-approved by FPI, is responsible for all in-field diagnosis and service work related to all warranty claims. This warranty does not cover dealer travel costs for diagnostic or service work. Dealers may charge homeowner for travel and additional time. Check with your selling dealer in advance for any costs to you when arranging a warranty call. FPI is not responsible for results or costs of workmanship of unauthorised FPI dealers or agents in the negligence of their service work. Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product.

At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective and determine whether the warranty will apply prior to processing or authorising of any claim. Failure to allow this upon request will void the warranty.

All warranty claims must be submitted by the dealer servicing the claim, including an original copy of the tax invoice (proof of purchase by you). All claims must be complete and provide full details as requested by FPI to receive consideration for evaluation, including proof of maintenance records. Incomplete claims may be rejected. FPI has absolute discretion to assess and determine any warranty claim and may accept or reject a claim as it considers appropriate. Any part or parts of the unit found to be defective will be repaired or replaced at FPI's option, through an accredited distributor or service agent provided that the defective part be returned to the distributor or agent, Transportation Prepaid, if requested. It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect.

If a consumer has a unit installed outside an accredited distributor, dealer or pre-approved service agent's service area, or the closest approved service agent is situated more than thirty (30) kilometres from the installation, FPI is not obliged to arrange warranty repairs or shipping/transportation costs. In these cases, the consumer must arrange warranty service with its selling dealer, and shipping, travel and/or additional labor charges will apply.

Unit must be installed according to all manufacturers' instructions as per the manual.

All Local and National required codes must be met.

The installer is responsible to ensure the unit is operating as designed at the time of installation.

The original purchaser is responsible for annual maintenance of the unit, as outlined in the owner's manual. As outlined below, the warranty may be voided due to problems caused by lack of maintenance. Annual maintenance records should be retained.

Exclusions:

This Limited Warranty does not extend to paint, rust or corrosion of any kind due to a lack of maintenance or improper venting, combustion air provision, corrosive chemicals (i.e. chlorine, salt, air, etc.), firebrick (rear, sides or bottom), door or glass gasket, or any other additional factory fitted gasket.

Malfunction, damage or performance based issues as a result of environmental conditions, location, chemical damages, downdrafts, installation error, installation by an unqualified installer, incorrect chimney components (including but not limited to cap size or type), operator error, abuse, misuse, use of improper fuels (such as unseasoned timber, mill-ends, construction timber or debris, off-cuts, treated or painted timber, tea tree, metal or foil, plastics, garbage, solvents, cardboard, coal or coal products, oil based products, waxed cartons, compressed pre-manufactured logs), accidents, lack of regular maintenance and upkeep, acts of God, weather related problems from hurricanes, tornadoes, earthquakes, floods, lightning strikes/bolts or acts of terrorism or war, which result in malfunction of the appliance are not covered under the terms of this Limited Warranty.

FPI has no obligation to enhance or modify any unit once manufactured (i.e. as products evolve, field modifications or upgrades will not be performed on existing appliances).

Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty. This includes units with rusted or corroded fireboxes which have not been reported as rusted or corroded within three (3) months of installation/purchase. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior fascia or over firing that can cause component or firebox/heat exchanger failure will not be covered by this warranty.

Units which show evidence of being operated while damaged, or with problems known to the purchaser and causing further damages will void this warranty.

Units where the serial no. has been altered, deleted, removed or made illegible will void this warranty.

Minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this warranty.

Freight damages for products or parts are not covered under the terms of the warranty.

Porcelain/Enamel: Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by the authorised selling dealer within three (3) days of installation. Any damage of this type not reported after this time period will be subject to rejection and any related warranty will not apply.

Special Finishes: Expect some changes in color as the product "ages" with constant heating and cooling. The manufacturer warranty does not cover tarnishing, changing colors and/or marks (i.e. finger prints, etc.) after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.

Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorisation from FPI may void this warranty.

INCORRECT INSTALLATION IS NOT COVERED BY WARRANTY. A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES.

Limitations of Liability:

1. Exclusion of implied terms

The customer may have the benefit of consumer guarantees under the Australian Consumer Law. To the maximum extent permitted by law, all terms, conditions or warranties that would be implied into this Warranty or in connection with the supply of any goods or services by the supplier under law or statute or custom or international conventions are excluded.

2. Limitation of liability

(a) To the maximum extent permitted by law and subject to clauses 1 and 3, the supplier's total liability arising out of or in connection with its performance or its obligations pursuant to this Warranty, or arising out of or in connection with the supply of specific goods or services (including pursuant to or for breach of this Warranty, under statute, in equity or for tort, including negligent acts or omissions) is limited as follows: (i) the supplier shall have no liability to the customer for any Consequential Loss; (ii) without limiting the effect of clause 2(a)(i), the supplier's total aggregate liability for Loss, however arising, shall not exceed the GST exclusive aggregate price paid by the customer to the supplier for the specific goods or services that gave rise to the Loss in question.

(b) The limitations and exclusions in this sub-clause do not apply to the extent that any Loss is directly attributable to: (i) the personal injury or death caused by the supplier's default, breach of this Warranty or negligence; or (ii) fraud by the supplier.

(c) Each party must take reasonable steps to mitigate any Loss it suffers or incurs.

3. Limitation of liability under Australian Consumer Law Guarantees

(a) To the extent that goods supplied by the supplier are not goods of a kind ordinarily acquired for personal, domestic or household use and the customer is deemed to be a consumer for the purposes of section 64A of the Australian Consumer Law, the customer agrees that the supplier's liability for a failure to comply with a consumer guarantee that the customer may have a benefit under the Australian Consumer Law (other than a guarantee under sections 51 (title), 52 (undisturbed possession) and 53 (undisclosed securities)), is limited to, at the option of the supplier, one or more of the following: (i) replacement of the goods or the supply of equivalent goods; (ii) the repair of the goods; (iii) the payment of the cost of replacing the goods or of acquiring equivalent goods; or (iv) equivalent goods; or (v) the payment of the cost of having the goods repaired.

(b) To the extent that services supplied by the supplier are services other than services of a kind ordinarily acquired for personal, domestic or household use or consumption, the supplier's liability for failure to comply with a consumer guarantee that the customer may have the benefit of is limited to, at the option of the supplier: (i) the supply of the services again; or (ii) the payment of the cost of having the services supplied again.

4. Subject to Change

This Limited Warranty is given at the time of sale and purchase of the relevant fireplace product. The terms of this Limited Warranty may be amended from time to time by FPI in accordance with changes to business practices, consumer laws or other legal requirements. The rights and protections granted under the Limited Warranty are those in force in relation to a fireplace product at the time and in the place of sale of that product, and only those terms will be applicable in respect of that product.

5. Severability

Any term of this Limited Warranty that is invalid or unenforceable in any jurisdiction is to be read down for the purposes of that jurisdiction, if possible, so as to be valid and enforceable, and is otherwise capable of being severed to the extent of the invalidity or unenforceability, without affecting the remaining provisions of this Limited Warranty or affecting the validity or enforceability of that provision in any other jurisdiction.

6. Definitions

For purposes of clauses 1, 2 and 3:

(a) Consequential Loss means loss of expected savings, loss of use, loss of opportunity, loss of profit, loss of revenue, increased financing costs, loss arising from delay, or any consequential, special or indirect loss or damage, whether or not the possibility or potential extent of the loss or damage was known or foreseeable, and whether arising from a claim under indemnity, contract, tort (including negligence), statute or otherwise.

(b) Loss means any expense, cost or damage of any kind and includes Consequential Loss and a fine or penalty imposed by a statutory or other authority.

How to Obtain Warranty Service:

Customers should contact the authorised selling dealer to obtain warranty service. In the event the authorised selling dealer is unable to provide warranty service, please contact FPI by mail at the address listed below. Please include your name, address, purchase date, selling dealer, serial #, type of unit, a brief description of the problem, email and telephone contact information, and a copy of your original tax invoice. A representative will contact you to make arrangements for an inspection and/or warranty service. (See below for Western Australia and/or New Zealand)

Please note Fireplace Products Australia Pty Ltd does not provide installation services.

Fireplace Products Australia Pty Ltd

99 Colemans Road

Dandenong South, VIC

Australia, 3175

Phone: +61 3 9799 7277

Fax: +61 3 9799 7822

To obtain warranty service in Western Australia and/or New Zealand, please contact one of our authorised distributors in those areas:

Western Australia:

New Zealand:

Air Group Australia

131 Bannister Rd

Canning Vale WA

Australia, 6155

Phone: (08) 9350 2200

Fax: (08) 9353 4225

Aber Holdings Ltd

PO Box 10095

Te Rapa, Hamilton

New Zealand, 3241

Freephone: 0800 161 161

Product Registration and Customer Support:

Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com.au/Customer-Care/Warranty-Registration.aspx within ninety (90) days of purchase.

Product Registration and Customer Support:

Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.

For purchases made in CANADA or the UNITED STATES:

http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx

For purchases made in AUSTRALIA:

http://www.regency-fire.com.au/Customer-Care/Warranty-Registration.aspx

You may also complete the warranty registration form below to register your Regency Fireplace Product and mail and/or fax it back to us, and we will register the warranty for you. It is important you provide us with all the information below in order for us to serve you better.

Warranty Registration Form (or Register online immediately at the above Web Site):

Warranty Details
Serial Number (required):
Purchase Date (required) (mm/dd/yyyy):
Product Details
Product Model (required):
Dealer Details
Dealer Name (required):
Dealer Address:
Dealer Phone #:
Installer:
Date Installed (mm/dd/yyyy):
Your Contact Details (required)
Name:
Address:
Phone:
Email:

For purchases made in CANADA:

For purchases made in the UNITED STATES:

For purchases made in AUSTRALIA:

FPI Fireplace Products

International Ltd.

6988 Venture St.

Delta, British Columbia

Canada, V4G 1H4

Fireplace Products US, Inc.

PO Box 2189 PMB 125

Blaine, WA

United States, 98231

Fireplace Products Australia Pty Ltd

99 Colemans Road

Dandenong South, Vic. 3175

Australia

Phone: 604-946-5155

Fax: 1-866-393-2806

Phone: 604-946-5155

Fax: 1-866-393-2806

Phone: +61 3 9799 7277

Fax: +61 3 9799 7822

warranty

Installer: Please complete the following information

Dealer Name & Address: ____

Installer:

Phone #: ____

Date Installed: ____

Serial #: ____

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Regency

Model : Mansfield L850B ST

Category : Heating