ERAF 0921A - Water pump GREE - Free user manual and instructions
Find the device manual for free ERAF 0921A GREE in PDF.
| Product Type | Water Pump |
| Brand | Gree |
| Model | ERAF 0921A |
| Pump Type | Centrifugal |
| Dimensions (W x H x D) | 30 cm x 25 cm x 20 cm |
| Weight | 8 kg |
| Power Rating | 750 W |
| Voltage / Frequency | 220-240 V / 50 Hz |
| Max Flow Rate | 60 L/min |
| Max Head | 30 m |
| Inlet / Outlet Diameter | 1 inch (25 mm) |
| Housing Material | Cast Iron |
| Impeller Material | Stainless Steel |
| Protection Class | IPX4 |
| Noise Level | 70 dB |
| Features | Thermal overload protection, dry-run protection |
| Maintenance | Clean inlet filter monthly; check seals annually |
| Safety | Do not operate without water; keep away from children |
| Spare Parts | Available from Gree authorized service centers |
| General Information | Suitable for garden irrigation and water transfer |
Frequently Asked Questions - ERAF 0921A GREE
User questions about ERAF 0921A GREE
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Water pump in PDF format for free! Find your manual ERAF 0921A - GREE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ERAF 0921A by GREE.
USER MANUAL ERAF 0921A GREE
natural_image
Exterior view of a Schneider Electric industrial control unit (no visible text or symbols beyond branding)Water Input Reg. SetP. On C 07.0 Mode: Set Point Standard
line
| Point | T_EXT | SOLLWERT | |-------|-------|----------| | P1 | Low | Low | | P2 | High | High || Auto E/I com. | |
| On Ext. Temp.:No | |
| On Hot to: °C 00.0 | |
| On Cold to: °C 00.0 | |
| Commutation delays | |
| in Hot in min 000 | |
| in Cold in min 000 |
| I/O via Contact | N |
| I/O via Serial | N |
| E/I via Contact | N |

(From Remote Control)
Hours/Minutes 12:00 TT/MM/JJ 01/01/13 Day of the week Fri
| Clock | |
| Daylight savings time: OFF | |
| Trans. Time 000min | |
| Start: --- | |
| in --- at ---.00 | |
| End: --- | |
| in --- at ---.00 |
| Clock | |
| Daylight savings time: | |
| Trans. Time | 060min |
| Start: | Last Sunday |
| in March at | 02.00 |
| End: | Last Sunday |
| in October at | 03.00 |
Unit on cycles
| Enable: | YES |
| SetPoint 1 | 7.0 |
| SetPoint 2 | 10.0 |
| Unit on cycles |
| MON copy to TUES: NO00.00 + 00:30 |
| 00-08:_ _ _ _ _ _ _ _ |
| 08-16:_ _ _ _ _ _ _ _ |
| 16-24:_ _ _ _ _ _ _ _ _ |
EINSTELLUNGEN
| NO | MODBUS MASTER |
| MOD_MB_Protocol_MNG | |
| Version:2.3 04/11/10 | |
| 1st Master | |
| Sublist number: | 00 |
| Sublist trigger: | ■ |
| General trigger: | ■ |
| Polling time: | 000ms |
Circulation Pumps: 2 Variable Speed: Y
Control Type: Modbus
UNIT CONFIGURATION
Fans Type: EC
EINSTELLUNGEN
Danfoss ETS 12.5 0 25B
(IG Slave Address:21)
Aux:Main
12:00 01/01/15 LAN 01
T.Water OUT°C 7.0

Energy Power Meter: Y
Type=S= PM3250
(Slave Address:20)
| UNIT CONFIGURATION | |
| Isolating Valve | Y |
| CtrlMode:Y | |
| ON Delay Time s | 60 |
| PUMP DOWN CONFIG. | |
| Enable | N |
| Max.Time: | sec 20 |
| SENSOR OPTIONAL | |
| Water Pressure | N |
| Freigabe Remote | N |
| Wat. T.Sens | N |
| Refr. Liquid Temp. | N |
| Additional Temp. | |
| N | |
| PRESSURE TRANSDUCERS | |
| High Press.Sensor | |
| Range Begin kPa | 0 |
| Range End kPa | 3500 |
| PRESSURE TRANSDUCERS | |
| Water | |
| Range Begin kPa | 0 |
| Range End kPa | 1000 |
| REMOTE CONTROL | |
| I/O via Contact | N |
| I/O via Serial | N |
| E/I via Contact | N |
EINSTELLUNGEN
Full Charge Last Power Fail. 000
| Fan Speed Setting (summer) | |
| On: 25 C | Off |
| Ramp begin. | (Aus): |
| Ramp ending | 20°C |
| 28°C | |
| Ultra Quiet(High Ramp45°C | |
| Ramp2 begin. | |
| Ramp2 begin. | |
| Fan Speed Setting (summer) | |
| DT.Ext-Cond Min. | 7.0°C |
| Integral Time | 100s |
| Derivat. Time | 0s |
| Time Pulse Start | 120s |
| Fan Speed Reg. (Winter) | |
| On:17°C | OFF:18°C |
| Ramp begin. | 16°C |
| Ramp ending | 12°C |
Water Flow FS Alarm:N
Cond.Temperature Limit
HEAT RECOVERY
Water Flow FS Alarm
FS Start Delay
s00
FS Run Delay
s00
EINSTELLUNGEN
- 0–10Vdc
- 0–20mAmp
- 4–20mAmp
- Digital Input
• R S 4 8 5 O M I
• LAN from Unit 1
SETPOINT REMOTE Offset Enable: Y 0-10V Signal
Opt.SetP. °C 00.0 Zero Adj. mV 00
Signal \$ 0.0
SETPOINT REMOTE Offset Enable: Y RS485 OMI Signal
Max Offset 9C: 5.0
Signal § 0.0
SETPOINT REMOTE Offset Enable: Y LAN From Unit 1
Max Offset 2C: 5.0
Signal § 0.0
(Autoadaptive oper.)
Act.Head Pres.kPa 0000
Al.Max Speed 100.0%
Set Head Press.kPa 150
Pump Inverter
CTRL Head Press:Y
(Flexible operat.)
Act.Head Pres.kPa 0000
Speed request 000.0%
Pump PID Regulation
Act.Head Pres. kPa 000
Set Head Press.kPa 000
Prop.Band 0000
Int.Time s 000
Der.Time s 000
Usage of Pres.Values
Local
EINSTELLUNGEN
(Read only) Min frequency: 0.0Hz Max frequency: 0.0Hz
Accel.time: 0.0s decel.time: 0.0s
Power Supply Settings Thresh. Failure V20.0 I.G. Time Ch. Over s20
UCAP Recharge Time s300 Max Time Life s60 Delay Work Alarm s10
Emergency Recovery
Enable: Y
Activ.At Power ON If Temp wout>SetP+9C 6.0
DELAY SETTINGS
Power On Delay s 000 Start Trans. s 20 Temp.Al.Delay min 15
DELAY SETTINGS
FS Start Delay s 10 FS Run Delay s 5 Pump Changeover h 12
COMPRESSOR TIMING
Cycle minimum s 360 Minimun Run Time s 120 Minimun Off Time s 180 Between 2 diff. s 75 Betw.2 diff.min. s 30
F.C. K Multipl. 2.0
EINSTELLUNGEN
Sample Time: 00:00:00
Reset graph: N
Autoscale: N
Low limit: 000
High limit: 000
EINSTELLUNGEN
Sensorkalibrierung
Read Value 9C 000.0 Adjustment 9C 00.0
SPEICHERVORGÄNGE
Program Set up N A1.Page Clear-up N
PROGRAM SETUP [Programm-Setup]:
Default installation running....
Please wait
switch-off and back on the controller
WARNING: Too many BMS Write from BMS
Legend: N.O.: Normally Open N.C.: Normally Close
![GREE ERAF 0921A - PROGRAM SETUP [Programm-Setup]: - 1](/content/2026/05/1059129/images/244bb7ff41f73f3622bbf2847b58332f1ddd308be5fe6ae66f7b2650aa642182.jpg)
Water Flow = A Water Flow Serious AR Pump Therm. Switch = A
Antifreeze B Antifreeze Serious AR High Ev.Water IN T. B Low Ev.Water In T. B
![GREE ERAF 0921A - PROGRAM SETUP [Programm-Setup]: - 2](/content/2026/05/1059129/images/7940361af3afd7721fbf8cc1c12838aaa8012998fe531d65f8a03e284f3f551b.jpg)
High Pressure AR Compr.Thermal =B Compr.Thermal Ser. AR Low Pressure =B Low Pressure SeriousAR
![GREE ERAF 0921A - PROGRAM SETUP [Programm-Setup]: - 3](/content/2026/05/1059129/images/011ccc097ad881d6e0071657f8ae559214f83ae3d78de302e28e1567e1f6e94c.jpg)
I.G. Offline =B Too Much ChangeOver A
![GREE ERAF 0921A - PROGRAM SETUP [Programm-Setup]: - 4](/content/2026/05/1059129/images/d7a198ce5bd95eeb967590890e1ffa4db2ac5024db58f295aff503a7d1e8860b.jpg)
Unit IN Sensor =-- Unit OUT Sensor =AR Ext.Air Sensor =B Water Tank Sensor =B Cond.Press.Sensors A Evap.Press.Sensors AR T.Liquid Sensors =B Additional Probe =B
![GREE ERAF 0921A - PROGRAM SETUP [Programm-Setup]: - 5](/content/2026/05/1059129/images/c447369e7bed1f037dc587e5d9662182bde7a5b33854b21966cdcd600c50b0ca.jpg)
Phases Sequence =B Phases Sequence Ser. AR EEPROM =AR Supply Frequency =AR Wrong Password =-- Fan Thermal =B Fan Thermal Serious AR Fuse Fault =A
![GREE ERAF 0921A - PROGRAM SETUP [Programm-Setup]: - 6](/content/2026/05/1059129/images/f96c0c888875c4194685e63f7a085e9166072e399c992eb45027d7418ab00710.jpg)
Pumps Run Hours =-- Compr. Run Hours =--
LAN Interrupted =A BMS Error =--
![GREE ERAF 0921A - PROGRAM SETUP [Programm-Setup]: - 7](/content/2026/05/1059129/images/7c6cd0a98c538bfa257a6afb1bb09069a4641b85727e8b1a4b5dc6ad6f89b4b8.jpg)
Heat Recovery: - Not Possible =B - Locked =AR
Water IN/OUT Sensor A Exp.Board Offline =AR
![GREE ERAF 0921A - PROGRAM SETUP [Programm-Setup]: - 8](/content/2026/05/1059129/images/c2417833f45b3a31ff30c83a45cdea04f32c6dcc460bf66b4e207c1277b45b31.jpg)
Water Press.Sensors B Hi/Low Water Press. A Inverter P. Offline AR Inv. P. Not Serious B Inverter P. Serious A
![GREE ERAF 0921A - PROGRAM SETUP [Programm-Setup]: - 9](/content/2026/05/1059129/images/3677538893d7c681f5aa07ee5631973f67c2459bbacb6a39ab65d4c7f710b3ec.jpg)
Gas Detector = B Gas Det. Run Months B
Display address
Setting......:11
I/O Board address: 01
Display address
Setting.....:00
Display address
Setting......:11
I/O Board address: 01
Display address
Setting.....:00
Display address
Setting......:12
I/O Board address: 02
P:02 Adr Priv/Shared Trm1 12 Pr Trm2 32 Sh Trm3 None --
flowchart
graph TD
A["pLAN 32 GEMEINSAM"] --> B["6.54.3.2.10"]
B --> C["1231.2.3"]
C --> D["8.5.4.3.2.10"]
D --> E["1231.2.3"]
E --> F["1231.2.3"]
F --> G["1231.2.3"]
G --> H["1231.2.3"]
H --> I["1231.2.3"]
I --> J["1231.2.3"]
J --> K["1231.2.3"]
K --> L["1231.2.3"]
L --> M["1231.2.3"]
M --> N["1231.2.3"]
N --> O["1231.2.3"]
O --> P["1231.2.3"]
P --> Q["1231.2.3"]
Q --> R["1231.2.3"]
R --> S["1231.2.3"]
S --> T["1231.2.3"]
T --> U["1231.2.3"]
U --> V["1231.2.3"]
V --> W["1231.2.3"]
W --> X["1231.2.3"]
X --> Y["1231.2.3"]
Y --> Z["1231.2.3"]
Z --> AA["1231.2.3"]
AA --> AB["1231.2.3"]
AB --> AC["1231.2.3"]
AC --> AD["1231.2.3"]
AD --> AE["1231.2.3"]
AE --> AF["1231.2.3"]
AF --> AG["1231.2.3"]
AG --> AH["1231.2.3"]
AH --> AI["1231.2.3"]
AI --> AJ["1231.2.3"]
AJ --> AK["1231.2.3"]
AK --> AL["1231.2.3"]
AL --> AM["1231.2.3"]
AM --> AN["1231.2.3"]
AN --> AO["1231.2.3"]
AO --> AP["1231.2.3"]
AP --> AQ["1231.2.3"]
AQ --> AR["1231.2.3"]
AR --> AS["1231.2.3"]
AS --> AT["1231.2.3"]
AT --> AU["1231.2.3"]
AU --> AV["1231.2.3"]
AV --> AW["1231.2.3"]
AW --> AX["1231.2.3"]
AX --> AY["1231.2.3"]
Standby Unit Mode ON:
Standard
Sustain Unit OFF s 00
LAN CONFIGURATION Reg.Step Calling Mode: Standalone
Usage of Temp.Values Mode: Local
LAN CONFIGURATION Reg.Step Calling Mode: Standalone
Usage of Temp.Values Mode: Mean Mean/Loc.Diff. °C 0.0
EXV-EINSTELLUNGEN
HINWEIS
| COMPR. | EXV |
| 25% | 60% |
| 50% | 75% |
| 75% | 90% |
| 100% | 100% |
EXV Power Cooling
| Press.Prob. Failure: |
| At Comp.Start |
| At Normal Working |
ALARMAUSGABEN
Pump 1 Stopped Check Motor protection/ Contactor

Input Water Temp. Over Maximum Limit

Input Water Temp. Over Minimum Limit

Compr. 1 Overload Check Absorption/
ALARMAUSGABEN
with Incorrect Pass-word
(At least 3 Attempts)
Interrupted or Fault:
Check Probe/Connect
Flow switch fault Check commutation contacts/Connect

Antifreeze Circ. 1 Check Evap. Clean/ Load Refrigerant
(Automatic Reset)

Driver EXV Circ.1: No communications Tlan Interrupted

EXV1: Suct. T. Probe Interrupted or Fault: Check Probe/Connect

Driver EXV Circ.1: MOP Prot. Failed

Driver EXV Circ.1: LOP Prot. Failed

Driver EXV Circ.1: LowSSH
ALARMAUSGABEN
⚠️ Heat recovery not possible (out of limits)
pCOe: Expansion board Not Connected
⚠️ Fan Overload protection
Low P.Hydraulic Circ.
High P.Hydraulic Circ.

Fuse 230V F1 Electrical Resistance Fault
ALARMAUSGABEN
Freecooling Driven Valve Blocked (Full Open)
OMI Not Connected Check RS485 Line
| Emergency Recovery | ||
| Parameter Einht DEF. | ||
| Twout > SetP+ °C 6,0 | ||
| Power OFF Time | s | 0 |
| Maximum Em. Rec. Time | s 0 | |
| Timed ON | s | 10 |
| DT Rated Water | °C 0,0 | |
| Verzögerungseinstellungen | ||
| Parameter Einht DEF. | ||
| Power On Delay | s | 0 |
| Start Trans. | s 20 | |
| Temp.Al.Delay | Min. | 15 |
| FS Start Delay | s 10 | |
| FS Run Delay | s 03 | |
| Pump Changeover | h 12 | |
| Compressor Timing | ||
| Parameter Einht DEF. | ||
| Cycle Minimum | s 360 | |
| Minimum Run Time | s 180 | |
| Minimum Off Time | s 60 | |
| Between 2 diff. | s 75 | |
| Betw.2 diff.min. | s 30 | |
| F.C. K Multipl. | s 20 | |
| LP-Start Delay | s 90 | |
| LP-Run Delay | s 10 | |
| Offset Adjustment | ||
| Parameter Einht DEF. | ||
| Adjustment | °C 0,0 | |