Product TypeRemote Control Transmitter
BrandInterlogix
ModelTX-E101
CompatibilityInterlogix security systems (e.g., Concord, Simon, NetworX)
Power SourceBattery powered
Battery TypeCR2032 3V lithium coin cell
Operating Frequency319.5 MHz (typical for Interlogix)
RangeUp to 150 ft (45 m) in open air
Number of Buttons4 (Arm, Disarm, Panic, Auxiliary)
Dimensions2.6 x 1.5 x 0.5 in (66 x 38 x 12 mm)
Weight0.6 oz (17 g) including battery
ColorWhite
MaterialABS plastic
LED IndicatorRed LED on button press
MountingHandheld or keychain
Waterproof RatingNot rated, indoor use only
Operating Temperature32°F to 120°F (0°C to 49°C)
CertificationsFCC, Industry Canada
Battery LifeApproximately 2 years typical use
Warranty1 year limited warranty
Manual LanguagesEnglish (EN)

Frequently Asked Questions - TX-E101 Interlogix

How do I pair the TX-E101 remote with my Interlogix alarm system?
To pair, enter programming mode on your system panel (consult panel manual). Press and hold a button on the remote until the panel indicates successful enrollment. The TX-E101 uses 319.5 MHz frequency.
What battery does the TX-E101 remote use and how do I replace it?
The remote uses a CR2032 3V lithium coin cell. To replace, slide the battery cover off, remove old battery, insert new one with positive side up, and close the cover.
What is the range of the Interlogix TX-E101 remote?
The range is up to 150 feet (45 meters) in open air. Walls and obstacles may reduce the range.
How many buttons does the TX-E101 have and what do they do?
It has 4 buttons: Arm (arms system), Disarm (disarms system), Panic (triggers alarm), and Auxiliary (programmable for other functions like lights or garage door).
Can I use the TX-E101 with a Simon XT or Concord panel?
Yes, the TX-E101 is compatible with many Interlogix panels including Simon XT, Simon XTi, Concord, and NetworX series. Check system compatibility in your panel manual.
Why is my TX-E101 remote not arming/disarming the system?
Check the battery first. Ensure the system is in learn mode when pairing. Verify you are within range. If still not working, try reprogramming the remote by deleting it and re-adding it to the panel.
How do I perform a factory reset on the TX-E101 remote?
The TX-E101 does not have a user-accessible factory reset. To reset, you need to delete the remote from the panel using the panel's programming menu, then re-add it. Remove battery for 30 seconds may help.
Is the TX-E101 waterproof?
No, the TX-E101 is rated for indoor use only. It is not waterproof. Avoid exposing it to rain, moisture, or extreme humidity.
Can I attach the TX-E101 to my keychain?
Yes, the remote has a small hole for a keychain ring. You can attach it to your keys for easy carrying.
How long does the battery last in the TX-E101?
Typical battery life is 2 years with normal use. Frequent button presses or low temperatures may shorten battery life. A low battery warning may appear on the system panel.

User questions about TX-E101 Interlogix

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Remote control in PDF format for free! Find your manual TX-E101 - Interlogix and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TX-E101 by Interlogix.

USER MANUAL TX-E101 Interlogix

TX-E101 Four Button Chrome Wireless Keyfob

Installation Sheet

Enrolling

Each keyfob is learned in to a control panel as an unsupervised sensor and uses one available zone slot. For all Concord, Simon3 and Simon XT panels, use sensor group number 01, 03, 06 or 07. Please refer to your specific control panel installation manual for full instructions.

Operation

Lock

Depending on your control panel:

Press once to arm in Stay mode.

Press twice to arm in Away mode.

Press three times to activate the latchkey feature.

Unlock

Press this button to disarm your system. You do not have to enter your access code when you use this key to disarm the system.

Light

For NetworX panels, press this button to arm the system in Stay mode. For Concord, Simon 3 or XT it will turn system controlled lights on or off.

Star

The star button function depends on the individual panel programming. Refer to the installation instructions for your panel.

Panic or Aux

If the keyfob is programmed using a panic or portable auxiliary group number, pressing the Lock and Unlock buttons simultaneously will activate an audible or silent alarm (depending on group number) and initiate reports to the central station.

Replacing the Battery

Because keyfobs are non-supervised devices, a low battery signal will only be received by the control panel when the device is within range of the receiver and a button is pressed (if the device is not in use, no low battery signal will be sent until a button is pressed). When the device is carried beyond the range of the receiver and/or is seldom used/tested, the battery could wholly deplete without a warning of the battery condition being sent to the panel. If the LED on the device appears dim or does not turn on when a button is pressed, it is a warning that the battery may be low or depleted and should be replaced. To ensure proper functionality, test the device weekly and follow these simple steps to replace the battery when necessary:

  1. With a key or small screwdriver, press the black tab located at the bottom of the remote (fig.1) and slide the chrome trim off.
  2. Carefully separate the front and back piece of plastic to reveal the battery.
  3. Replace with a CR2032 battery ensuring the + side of the battery faces up (fig.2).
  4. Re-assemble the plastics and ensure they click together
  5. Ensure the notch in the chrome trim is aligned with the back of the plastic. It will only go on one way (fig. 3).

Figure 1

Figure 2

Figure 3

Specifications

Frequency319.5MHz
Battery3V lithium CR2032
Battery Life5 years
Operating Temperature 32^ - 120^ F ( 0^ - 49^ C)
Operating Humidity5-95% RH non condensing
CompatibilityInterlogix Learn Mode Panels and Receivers

FCC Compliance Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by UTC Fire and Security could void the user's authority to operate the equipment.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element shall be installed such that a minimum separation distance of 20 cm is maintained from the general population.

FCC: XQC-WST101

IC: 9863B-WST101

This Class B digital apparatus complies with Canadian ICES-3B.

For contact information, visit us online at www.interlogix.com.

For technical support, see www.interlogix.com/support

Copyright

Copyright © 2016 United Technologies Corporation. All rights reserved.

Trademarks

Interlogix is a registered trademark of United Technologies Corporation. Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.

Limitation of Liability

A PROPERLY INSTALLED AND MAINTAINED ALARM/SECURITY SYSTEM MAY ONLY REDUCE THE RISK OF EVENTS SUCH AS BREAK-INS, BURGLARY, ROBBERY OR FIRE; IT IS NOT INSURANCE OR A GUARANTEE THAT SUCH EVENTS WILL NOT OCCUR, THAT ADEQUATE WARNING OR PROTECTION WILL BE PROVIDED, OR THAT THERE WILL BE NO DEATH, PERSONAL INJURY, AND/OR PROPERTY DAMAGE AS A RESULT. WHILE INTERLOGIX UNDERTAKES TO REDUCE THE PROBABILITY THAT A THIRD PARTY MAY HACK, COMPROMISE OR CIRCUMVENT ITS SECURITY PRODUCTS OR RELATED SOFTWARE, ANY SECURITY PRODUCT OR SOFTWARE MANUFACTURED, SOLD OR LICENSED BY INTERLOGIX, MAY STILL BE HACKED, COMPROMISED AND/OR CIRCUMVENTED. INTERLOGIX DOES NOT ENCRYPT COMMUNICATIONS BETWEEN ITS ALARM OR SECURITY PANELS AND THEIR OUTPUTS/INPUTS INCLUDING, BUT NOT LIMITED TO, SENSORS OR DETECTORS UNLESS REQUIRED BY APPLICABLE LAW. AS A RESULT THESE COMMUNICATIONS MAY BE INTERCEPTED AND COULD BE USED TO CIRCUMVENT YOUR ALARM/SECURITY SYSTEM.

WARRANTY DISCLAIMERS

INTERLOGIX HEREBY DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS, WHETHER EXPRESS, IMPLIED, STATUTORY OR OTHERWISE INCLUDING (BUT NOT LIMITED TO) ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS SECURITY PRODUCTS AND RELATED SOFTWARE. INTERLOGIX FURTHER DISCLAIMS ANY OTHER IMPLIED WARRANTY UNDER THE UNIFORM COMPUTER INFORMATION TRANSACTIONS ACT OR SIMILAR LAW AS ENACTED BY ANY STATE. (USA ONLY) SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER LEGAL RIGHTS THAT VARY FROM STATE TO STATE. INTERLOGIX MAKES NO REPRESENTATION, WARRANTY, COVENANT OR PROMISE THAT ITS SECURITY PRODUCTS AND/OR RELATED SOFTWARE (I) WILL NOT BE HACKED, COMPROMISED AND/OR CIRCUMVENTED; (II) WILL PREVENT, OR PROVIDE ADEQUATE WARNING OR PROTECTION FROM, BREAK-INS, BURGLARY, ROBBERY, FIRE; OR (III) WILL WORK PROPERLY IN ALL ENVIRONMENTS AND APPLICATIONS.

DISCLAIMER

THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. UTC ASSUMES NO RESPONSIBILITY FOR INACCURACIES OR OMISSIONS AND SPECIFICALLY DISCLAIMS ANY LIABILITIES, LOSSES, OR RISKS, PERSONAL OR OTHERWISE, INCURRED AS A CONSEQUENCE, DIRECTLY OR INDIRECTLY, OF THE USE OR APPLICATION OF ANY OF THE CONTENTS OF THIS DOCUMENT. FOR THE LATEST DOCUMENTATION, CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT WWW.INTERLOGIX.COM THIS PUBLICATION MAY CONTAIN EXAMPLES OF SCREEN CAPTURES AND REPORTS USED IN DAILY OPERATIONS. EXAMPLES MAY INCLUDE FICTITIOUS NAMES OF INDIVIDUALS AND COMPANIES. ANY SIMILARITY TO NAMES AND ADDRESSES OF ACTUAL BUSINESSES OR PERSONS IS ENTIRELY COINCIDENTAL.

INTENDED USE

USE THIS PRODUCT ONLY FOR THE PURPOSE IT WAS DESIGNED FOR; REFER TO THE DATA SHEET AND USER DOCUMENTATION. FOR THE LATEST PRODUCT INFORMATION, CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT WWW.INTERLOGIX.COM THE SYSTEM SHOULD BE CHECKED BY A QUALIFIED TECHNICIAN AT LEAST EVERY 3 YEARS AND THE BACKUP BATTERY REPLACED AS REQUIRED.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Interlogix

Model : TX-E101

Category : Remote control