Product TypeSplit system air conditioner
Cooling Capacity3.5 kW (12,000 BTU/h)
Heating Capacity4.2 kW (14,300 BTU/h)
Power Supply230 V / 50 Hz / 1 Phase
RefrigerantR32
Indoor Unit Dimensions (W x H x D)870 x 290 x 230 mm
Outdoor Unit Dimensions (W x H x D)790 x 540 x 290 mm
Indoor Unit Weight10 kg
Outdoor Unit Weight26 kg
Energy Efficiency Ratio (EER)3.2 (cooling)
Energy Efficiency ClassA++ (cooling)
FunctionsCooling, Heating, Dehumidification, Fan, Auto Mode
Fan Speeds3 speeds + auto
Airflow Direction ControlVertical/horizontal auto louver
Remote ControlIncluded (wireless)
Timer24-hour on/off programmable timer
Sleep ModeYes
FilterWashable antimicrobial filter
Filter Cleaning ReminderYes
Self-Cleaning FunctionYes (indoor unit)
Noise Level (Indoor, low/high)25 dB(A) / 44 dB(A)
Noise Level (Outdoor)50 dB(A)
Piping Connections (Liquid/Gas)1/4" and 3/8"
Max. Pipe Length15 m
Operating Temperature Range-15°C to 46°C (cooling), -15°C to 24°C (heating)

Frequently Asked Questions - ASGG12CPAA-B FUJITSU

How do I clean the air filter?
Open the front panel, remove the filter, and wash it with warm water and mild detergent. Let it dry completely before reinstalling. Clean the filter every 2 weeks for optimal performance.
What does the error code 'E1' mean?
Error code E1 typically indicates a communication fault between indoor and outdoor units. Check the wiring connections and turn off the unit for 10 minutes. If the error persists, contact a qualified technician.
How can I save energy with my air conditioner?
Set the temperature to 24-26°C in summer and 20-22°C in winter. Use the timer and sleep mode. Keep curtains closed during hot days. Clean the filter regularly to maintain efficiency.
What is the recommended installation distance from walls?
The indoor unit should have at least 15 cm clearance on the top and sides, and 10 cm from the floor. The outdoor unit requires at least 50 cm of space in front and 30 cm on each side for proper airflow.
Can I use the air conditioner during winter?
Yes, the unit provides heating down to -15°C. However, if the outdoor temperature drops below -15°C, the heating capacity may decrease. Ensure the outdoor unit is free from snow and ice.
How do I reset the air conditioner?
Unplug the unit from the power outlet for 5-10 minutes, then plug it back in. Alternatively, use the remote control to turn the unit off, then press the RESET button on the remote (if available) or on the indoor unit.
What does the 'fan only' mode do?
In fan only mode, the compressor does not run. The indoor fan circulates air without cooling or heating. This is useful for air circulation when temperature conditioning is not needed.
How often should I service my air conditioner?
It is recommended to have professional maintenance every 1-2 years. This includes cleaning the coils, checking refrigerant levels, and inspecting electrical components. Regular maintenance extends the unit's lifespan.
What is the maximum length of the connecting pipes?
The maximum piping length is 15 meters. If the pipe length exceeds 7.5 meters, additional refrigerant may need to be added. Always consult a professional installer for long pipe runs.
How do I use the timer function?
Press the TIMER button on the remote control. Use the + or - buttons to set the desired ON or OFF time. The unit will automatically turn on or off at the scheduled time. Confirm by pressing SET.

User questions about ASGG12CPAA-B FUJITSU

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air-conditioner in PDF format for free! Find your manual ASGG12CPAA-B - FUJITSU and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ASGG12CPAA-B by FUJITSU.

USER MANUAL ASGG12CPAA-B FUJITSU

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : FUJITSU

Model : ASGG12CPAA-B

Category : Air-conditioner