Product TypeWater Dispenser
BrandRamtons
ModelRM/429
FunctionsHot, Cold, Ambient, Refrigerator Cabinet, Sterilizer Cabinet
Hot Water Temperature85-95°C (adjustable)
Cold Water Temperature5-15°C (compressor) or 12-16°C (electronic)
Ambient Temperature Range0-35°C
Atmosphere Range86-106 kPa
InstallationDesktop or upright; leave 10-20 cm clearance at back for ventilation
FaucetsHot (red), Cold (blue), Warm (blue), plus warm water faucet
Refrigerator CabinetYes, with thermostat; allow 2-hour run before storing food
Sterilizer CabinetYes, with timer: 5-10 min for fresh, 15 min for sterilization
Safety FeaturesDo not power on until water flows from hot tap; keep away from children; do not heat without water; angle <45° when moving
Maintenance - CleaningUse water-soaked soft cloth; never detergents or chemicals; do not spray water directly
Maintenance - DescalingFill hot tank with 2% citric acid solution, keep for 2 hours, then flush
Power CordSpecial cord; replace only through service center if damaged

Frequently Asked Questions - RM/429 Ramtons

Why is there no hot water?
Check that the heating switch on the back is turned on. Also ensure water is flowing from the hot tap before connecting power.
Why is the cold water not cold enough?
Verify that the cooling switch on the back is on. Also check that the dispenser has 10-20 cm clearance at the back for proper ventilation.
What causes the dispenser to make gurgling or rattling noises?
Gurgling or rattling sounds are normal due to refrigerant flow. Popping or cracking may occur from wall contraction/expansion. Ensure the unit is level.
How do I clean and maintain the water dispenser?
Use a water-soaked soft cloth to wipe surfaces. Never use detergents or chemicals. For descaling the hot tank, use a 2% citric acid solution for 2 hours, then flush.
What should I do if the dispenser is not cooling or heating at all?
First, check if the power cord is plugged in and the circuit breaker hasn't tripped. Then ensure both the heating and cooling switches on the back are turned on.
How do I use the sterilizer cabinet?
Turn the sterilize timer to 5-10 minutes for keeping fresh or 15 minutes for sterilization. After the cycle, leave the door closed for about one hour to allow ozone to decompose.
Why does the compressor turn on and off frequently?
This can occur if the room temperature is too hot or if the dispenser does not have adequate clearance (10-20 cm) behind it for ventilation.
How do I store the dispenser when not in use for a long time?
Allow hot water to cool, then unplug the unit. Open the hot water drain cock to drain the hot tank, then open the cold water tap to drain the cold tank. Tighten the drain cock after.
What should I check if the refrigerator cabinet is not cooling properly?
Ensure the door closes tightly. Avoid overfilling and keep space for air circulation. Also check that the refrigerator cabinet has been run for 2 hours before adding food.
How do I replace a damaged power cord?
The power cord must be replaced with a special cord available only through the Service Center of our company. Contact your dealer for assistance.

User questions about RM/429 Ramtons

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Water dispenser in PDF format for free! Find your manual RM/429 - Ramtons and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RM/429 by Ramtons.

USER MANUAL RM/429 Ramtons

Model 26,50,56

Ramtons RM/429 - 1
Model 52

Ramtons RM/429 - 2
Model 70

Ramtons RM/429 - 3
Model 50

Troubleshooting guide

problemPossible cause
Water dispenser does not operateNot plugged inThe circuit breaker tripped or blown fuse.
Water cooler is not cold enoughCheck to be sure the cold switch on the back is on.The water dispenser does not have the correct clearance.
Water dispenser hot water is not hot enoughCheck to be sure the hot switch on the back is on.
Compressor turns on and off frequentlyThe room temperature is hotter than normal.The water dispenser does not have the correct clearance.
vibrationCheck to assure that the water dispenser is level.
The water dispenser seems to make too much noise.The ratting noise may come from the flow of the refrigerant ,which is normal.As each cycles ends, you may hear gurgling.Sound caused by the flow of refrigerant in your water dispenser.Contraction and expansion of the inside walls may cause popping and cracking noises.The water dispenser is not level.
The refrigerator perform improperlyThere is direct sunlight and sources of heat (stove , heater ,radiator etc) around it.There is too much food in refrigeratorThe door does not close well.Door open frequently.

Maintenance and trouble shooting

  • Remove power plug or disconnect from the mains before performing any maintenance or servicing the product.
  • Never use detergent or chemicals harmful to health to clean the water tanks.
  • Do not directly spray water on the surface of the product.

Wipe the front and back of the product with water-soaked soft cloth.

  • If dust of other foreign substance has accumulated on the condenser ,wipe off with water-soaked soft cloth.
  • After cleaning the product, completely dry it. Fill the water to the tanks until waters comes out of the hot water tap, then connect the electric power plug. If the surface of the electric heater in the hot water tank is deposited by water deposition, heating capacity will decrease. Fill hot water tank with aqueous solution of 2% aitric acid and keep for about two hours then cleaning. If the problems can not be solved, contact your dealer or the Service Center of our company.
  • If the supply cord on this device is damaged. It must be replaced with a special cord which is obtainable at Service Center of our company.

Ramtons RM/429 - Maintenance and trouble shooting - 1
Model 18,60,62

Ramtons RM/429 - Maintenance and trouble shooting - 2

Model 12,15,16,23
Ramtons RM/429 - Maintenance and trouble shooting - 3

No. NAME

  1. WATER GUARD
  2. HEATING INDICATOR
    COOLING INDICATOR
  3. POWER INDICATOR
  4. COOLING INDICATOR
    WARMING INDICATOR
  5. BODY

  6. COLD WATER FAUCET(BLUE)
    WARM WATER FAUCET(BLUE)

  7. HOT WATER FAUCET(RED)
    WARM WATER FAUCET
  8. WATER HOLDER
  9. DOOR
  10. POWER CORD
  11. HOT WATER DRAIN COCK

  12. REFRIGERATE SWITCH

  13. COOLING SWITCH (GREEN)
  14. HEATING SWITCH (RED)
  15. REFRIGERATE THERMOSTAT
  16. COOLING THERMOSTAT
  17. CONDENSER
  18. COLD WATER DRAIN COCK
  19. STERILIZE TIMER

Operation:

• Ambient temperature
• Temperature 0-35℃
• Atmosphere 86-106kpa
- Desktop: Position the water on a desk or a teapoy
Upright: Position the water dispenser on the horizontal, structurally sound ground. Leave an adequate open space (10cm-20cm) behind the water dispenser for good ventilation.
- When using the bottles holding ultra-pure water, distilled water or space water with the so-called clever lid, tear off the hygienic label on the lid. Place the bottles at the intake, then the core of water guard will automatically open the valve and seal it in the meantime, when moving the bottles, the valve will also seal automatically to avoid any possible oozing.
- Push the hot water valve, bubbles are generated inside the bottle, indicating that water is flowing into hot water and cold water tanks, keep pressing the hot water valve until water flows out, dispensing cold water required need no particular adjustment.

  • Caution: Do not connect the electrical power plug, until water comes out of the hot water tap.
  • After water is flowing out from the hot tap, power can be on, the yellow LED indicator on the front light on (Model 26, Model 30)
  • Turn the heating switch on, the red LED indicator on the front lights on and the heating system starts working. When the hot water comes up(35-95°C) or so, the red light goes off, the heating system stops working is on a warm-keeping status. When the hot water temperature is lower than 85°C, the heating system will resume working again automatically.
  • Turn on the cooling switch, the green LED indicator on the front lights on and the cooling system starts working, when the cold water falls down to 5-15°C (for compressor-cooling) or 12-16°C (for electronic-cooling), the green light goes off, the cooling system stops working and is on a cold keeping status. When the cold water temperature goes up to a set degree, the cooling system will resume working again automatically.
  • Since the temperature has already been adjusted before leaving the factory, it is unnecessary for customers to set the temperature.
  • Turn the heating, cold water and fridge switch on. Then the heating and refrigerating processes start working, the heating indicator is red showing it is heating. When the hot water temperature reaches the set limit, the heating process starts working automatically. When the refrigerating is lit green, the cold water and fridge system starts working. The refrigerating indicator goes out as the temperature of the cold water and fridge get the set lower limit. The refrigerating process stop working, when either the cold water temperature or fridge temperature get the set upper limit. The refrigerating indicator is lit and the process of cold water and fridge starts working again. Turn on either the cold water switch or fridge switch, the process can work separately.
  • Warm and hot water dispenser: The red indicator lights on and the green light goes off, the heating system starts working; The red light goes off and the green indicator lights on, the heating system stops working is on a warm-keeping status.
  • Warm and cold water dispenser: The green indicator lights on, the cooling system starts working; The green light goes off, the cooling system ends working.
  • Cold and hot water dispenser: The red indicator lights on, the heating system works. The red light goes off, it is on a warm-keeping status; The green indicator light on, the cooling system works; The green light goes off, it is on a cold-keeping status.
    • Cold and hot water dispenser (double color indicator): The heating system starts

working, the indicator is red; When the heating system stops working is on a warm-keeping status, the red indicator change into green. When the cooling system starts working, the indicator is green, when the cooling system stops working is on a cold-keeping system, the green indicator change into yellow.

• How to operate sterilize cabinet
Please turn around the switch: sterilize timer. Set at the 5-10min for keeping fresh, or set at 15 min for sterilizing, when the working is ended, the switch will come back to off location. Please still let the door closed for about one hour when there is no smell of ozone. It need for about one hour for the decomposition of ozone.
• How to operate refrigerator cabinet
When first using refrigerator cabinet. Don't put store in until it run the device about two hours. Hot food should be cooled to room temperature before he put in the cabinet. Proper space should be left for cool air to circulate.
- If the device is not applied for a long time, after the hot water cools down, please remove the power plug and revolve the drain cap to drain the rest water in the hot tank then tighten the cap open the cold water tap to drain the rest water in the cold tank.
- If there is no water flowing from cooling tap, please shut down the cooling switch until there is water flowing out.

Caution:

  • The back of the device should be kept away from wall and high-temperature elements, TV or video valuables and be put in shady places.
  • Do not switch on until water comes out of the hot water valve to prevent any damage on the heating tube.
  • During operation keeping it beyond the children to avoid scald.
  • Never turn on the heating switch when there is no water.
  • When carrying it, the angle of inclination should be less than 45°
  • Choose the proper electrical wire and plug, keep the plug from being too hot. Meanwhile, adopt the ground wire to avoid any electric shock. Please shut down the power before leaving or during night.
Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Ramtons

Model : RM/429

Category : Water dispenser