| Product Type | Range Hood |
| Brand | LG |
| Model | DC6121G |
| Width | 60 cm (estimated, typical for this model) |
| Depth | 50 cm (estimated) |
| Height | 15-20 cm (estimated) |
| Weight | Approximately 12 kg (estimated) |
| Power Supply | 220-240V, 50Hz |
| Motor Power | Approximately 150-200 W (estimated) |
| Number of Speeds | 3 or 4 (estimated) |
| Lighting | LED or halogen (estimated) |
| Extraction Capacity | Approximately 600-800 m³/h (estimated) |
| Noise Level | Approximately 55-65 dB (estimated) |
| Filter Type | Metal grease filter (washable) |
| Control Type | Electronic push buttons or slider (estimated) |
| Venting Type | Ducted or recirculating (estimated) |
| Installation | Under cabinet or wall-mounted (estimated) |
| Energy Class | A (estimated) |
| Maintenance | Clean grease filter monthly; replace charcoal filter if recirculating |
| Safety Features | Automatic shut-off timer, overheating protection (estimated) |
| Warranty | 2 years (estimated) |
Frequently Asked Questions - DC6121G LG
User questions about DC6121G LG
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Range hood in PDF format for free! Find your manual DC6121G - LG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DC6121G by LG.
USER MANUAL DC6121G LG
Model Numbers
DC9121GSA
DC6121GSA
GB Instruction Manual
If you follow the recommendations contained in this Instruction Manual, your appliance will give you constant high performance and will remain efficient for many years to come.
CONTENTS
| RECOMMENDATIONS AND SUGGESTIONS | 3 |
| CHARACTERISTICS | 4 |
| INSTALLATION | 6 |
| USE | 9 |
| MAINTENANCE | 10 |
INSTALLATION
The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
The minimum safety distance between the cooker top and the extractor hood is 650 mm.
⚠️ Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
⚠ For Class I appliances, check that the domestic power supply guarantees adequate earthing.
Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible.
Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.
Installation of the extractor hood over a solid-fuel burner(coal, wood, etc.) which could constitute a potential fire hazard (e.g. due to flying sparks) is only permitted if the burner is equipped with an enclosed, non-removable cover and all country-specific regulations are observed. This restriction dose not apply to gas cookers and gas hobs.
⚠️ Regulations concerning the discharge of air have to be fulfilled.
USE
The extractor hood has been designed exclusively for household use to eliminate kitchen smells.
⚠️ Never use the hood for purposes other than for which it has been designed.
⚠️ Never leave high naked flames under the hood when it is in operation.
Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
⚠️ Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
The hood should not be used by children or persons not instructed in its correct use.
Do not use the appliance if it is damaged in any way.
⚠️ Never operate the extractor hood without a grease filter.
Do not flambe food directly under the extractor hood.
MAINTENANCE
Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
⚠ Clean and/or replace the Filters after the specified time period.
⚠ Clean the hood using a damp cloth and a neutral liquid detergent.
⚠️ Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading.
There is a fire risk if cleaning is not carried out in accordance with the instructions.



Dimensions


Components

| Ref. | Q.ty | Product Components |
| 1 | 1 | Hood Body, complete with: Controls, Light, Blower, Filters |
| 2 | 1 | Telescopic Chimney comprising: |
| 2.1 | 1 | Upper Section |
| 2.2 | 1 | Lower Section |
| 9 | 1 | Reducer Flange ø 150-120 mm |
| 10 | 1 | Damper |
| 14.1 | 2 | Air Outlet Connection Extension |
| 15 | 1 | Air Outlet Connection |
| Ref. | Q.ty | Installation Components |
| 7.2.1 | 2 | Upper Chimney Section Fixing Brackets |
| 7.3 | 1 | Air Outlet Connection Support |
| 11 | 6 | Wall Plugs |
| 12a | 6 | Screws 4,2 x 44,4 |
| 12c | 6 | Screws 2,9 x 9,5 |
1 Documentation
Wall drilling and bracket fixing

Wall marking:
- Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed.
- Draw a horizontal line at 650 mm above the hob.
- Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line.
- Mark the wall at the centres of the holes in the bracket.
- Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line.
- Mark the wall at the centres of the holes in the bracket.
- Mark a reference point as indicated at 116 mm from the vertical reference line and 306 mm above the horizontal reference line.
- Repeat this operation on the other side.
- Drill φ 8 mm holes at all the centre points marked.
- Insert the wall plugs 11 in the holes.
- Fix the lower bracket 7.2.1 using the 12a screws (4,2 x 44,4) supplied.
- Fix the upper bracket 7.2.1 and the air outlet connection support 7.3 together using the 2 screws 12a (4,2 x 44,4) supplied.
- Insert the two screws 12a (4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap of 5-6 mm between the wall and the head of the screw.
Mounting the hood body
- Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points.
- Hook the hood body onto the screws 12a
• Fully tighten support screws 12a - Adjust screws Vr to level the hood body.

Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe 150 or 120 mm, the choice of which is left to the installer.
• To install the dumper 10
- To install a φ 120 mm air exhaust connection, insert the reducer flange 9 on the dumper 10.
- Fix the pipe in position using sufficient pipe clamps (not supplied).
- Remove any activated charcoal filters.

RECIRCULATION VERSION AIR OUTLET
- Put connection 15 into the connection support 7.3.
- Insert the connection extension pieces laterally 14.1 in connection 15.
- Make sure that the outlet of the extension pieces 14.1 is horizontally and vertically aligned with the chimney outlets.
- Connect the air outlet connection 15 to the hood body outlet using either a flexible or rigid pipe 150, the choice of which is left to the installer.
- Ensure that the activated charcoal filters have been inserted.

ELECTRICAL CONNECTION
- Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
- Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.

Flue assembly
Upper exhaust flue
- Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1, making sure that they are well seated.
- Secure the sides to the brackets using the 4 screws 12c (2,9 x 9,5) supplied.
- Make sure that the outlet of the extensions pieces is aligned with the chimney outlets.
Lower exhaust flue
- Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated.
• Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied.

Control Panel
![graph TD A["○"] --> B["*"] B --> C["L"] D["①"] --> E["T1"] F["2"] --> G["T2"] H["3"] --> I["T3"] J["4/1"] --> K["T4"] L["S1"] --> M["F"]](/content/2026/05/998477/images/655db8489a7a53cc232478ea9a935de8c4a11599767820a2ae1c9e3e6c9c2995.jpg)
The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button.
| LED | FUNCTIONS | ||
| L | 0/1 Light | Turns lighting on and off. | |
| T1 | 0/1 Motor | First speed.When pressed for about 1 seconds the motor is switched off. | |
| T2 | Speed | on | Second speed. |
| T3 | Speed | on | Third speed. |
| T4 | Speed | Fixed on | Max. speed |
| Flashing | Intensive speed.Suitable for the strongest cooking vapours and odours.The function becomes active when the button is pushed for about 2 seconds. After 10 minutes of functioning it turns off automatically. This function can be interrupted by means of pressing any of the buttons. | ||
| S1 | Led | Fixed on | Indicates that the Metal grease filters saturation alarm has been triggered, and the filters need to be washed.The alarm is triggered after 100 working hours. (Reset; check the Maintenance-paragraph) |
| Flashing | indicates that the activated charcoal odour filter saturation alarm has been triggered, and the filter has to be replaced; the metal grease filters must also be washed.The activated charcoal odour filter is triggered after 200 working hours. (Activation and Reset; check the Maintenance-paragraph) | ||
Grease filters
CLEANING METAL GREASE FILTERS
•Alarm signal reset
- Switch off the lights and extractor motor.
- Press button T3 for at least 3 seconds, until the leds T1,T4 start to flash.
Cleaning the filters
- The filters are washable and must be cleaned when the LED S1 lights up or at least every 2 months of operation, or more frequently for particularly heavy usage.
- Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
- Wash the filters, taking care not to bend them. Allow them to dry before refitting.
- When refitting the filters, make sure that the handle is visible on the outside.

Enabling/Disabling the alarm signal
- In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date.
- Turn the Lights and the suction Motor off.
- Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply or the connector of the feeding cable from the side of the fan.
- Restore the connection by pressing and holding T1
- Release the button. All five LEDs are turned on
- Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:
• LED flashes twice - Activated charcoal filter saturation alarm ENABLED
• LED flashes once - Activated charcoal filter saturation alarm DISABLED

REPLACING THE ACTIVATED CHARCOAL FILTER
- The filter is not washable and cannot be regenerated. It must be replaced when S1 flashes or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on.
Alarm signal reset
- Switch off the lights and extractor motor.
- Press button T3 for at least 3 seconds, until the leds start to flash.
Replacing the Filter
- Remove the metal grease filters
- Remove the saturated activated carbon filter by releasing the fixing hooks
• Fit the new filter by hooking it into its seating - Replace the metal grease filters.

Lighting
LIGHT REPLACEMENT
20 W halogen light.
- Remove the snap-on lamp cover by levering it from under the metal ring, supporting it with one hand.
- Remove the halogen lamp from the lamp holder by pulling gently.
- Replace the lamp with a new one of the same type, making sure that you insert the two pins properly into the housings on the lamp holder.
- Replace the snap-on lamp cover.


When switched on, the halogen bulbs become very hot. Even for some time after the bulbs have been switched off there is still a risk of burns.