Product Type Distribution Amplifier (HDBaseT)
Model AT-UHD-CAT-4ED
Brand Atlona
Inputs 4x HDMI (female)
Outputs 4x RJ-45 (CAT5e/6) + 1x HDMI loop-out
Video Resolution Up to 4K@60Hz 4:4:4 (HDR10, Dolby Vision)
HDCP Support HDCP 2.2 and 1.4
Transmission Distance Up to 330 ft (100m) via CAT6a
Power Supply External 24V DC, 2.71A (included)
Power Consumption 35W (max)
PoE Support PoE (Power over Ethernet) on receiver side
Audio Support PCM, Dolby Digital, DTS, Dolby TrueHD, DTS-HD Master Audio
Control RS-232, IR, TCP/IP, Web GUI
Dimensions (W x D x H) 17.0" x 8.5" x 1.7" (432 x 216 x 44 mm)
Weight 5.5 lbs (2.5 kg)
Operating Temperature 32°F – 104°F (0°C – 40°C)
Humidity 10% – 90% (non-condensing)
Rackmount 1U rack mountable (brackets included)
EDID Management Built-in EDID emulation and learning
Warranty Limited 10 years

Frequently Asked Questions - AT-UHD-CAT-4ED Atlona

What is the maximum resolution supported by the AT-UHD-CAT-4ED?
The device supports resolutions up to 4K@60Hz 4:4:4 with HDR10 and Dolby Vision.
How far can I extend the signal using CAT6a cable?
You can extend 4K signals up to 330 feet (100 meters) using CAT6a or better cable.
Does the AT-UHD-CAT-4ED support HDCP 2.2?
Yes, it is fully compliant with HDCP 2.2 and backward compatible with HDCP 1.4.
Can I use Power over Ethernet (PoE) for the remote receivers?
Yes, the transmitter provides PoE to compatible receivers, eliminating the need for separate power at the remote end.
How do I control the unit?
The amplifier can be controlled via RS-232, IR, TCP/IP, or the built-in web GUI.
What is the power supply specification?
It uses an external 24V DC 2.71A power supply (included). The maximum power consumption is 35W.
Is the device rack-mountable?
Yes, it is 1U rack mountable and comes with rack ears included.
Can I use it with CAT5e cable?
Yes, but for maximum performance and distance, CAT6a is recommended. CAT5e may limit distance to about 230 feet (70m).
Does it support audio return?
No, the AT-UHD-CAT-4ED is a unidirectional distribution amplifier. For bidirectional audio, consider models with ARC/eARC.
What is the warranty period?
Atlona offers a limited 10-year warranty on this product.

User questions about AT-UHD-CAT-4ED Atlona

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Distribution Amplifier in PDF format for free! Find your manual AT-UHD-CAT-4ED - Atlona and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AT-UHD-CAT-4ED by Atlona.

USER MANUAL AT-UHD-CAT-4ED Atlona

Version Release Date Notes
6 Oct 2023 -Corrected typo errors in firmware update procedure.

Sales, Marketing, and Customer Support

Main Office

Atlona Incorporated

70 Daggett Drive

San Jose, CA 95134

United States

Office: +1.408.962.0515

Sales and Customer Service Hours

Monday - Friday: 6:00 a.m. - 4:30 p.m. (PST)

https://atlona.com/

International Headquarters

Atlona International AG

Tödistrasse 18

8002 Zürich

Switzerland

Office: +41.43.508.4321

Sales and Customer Service Hours

Monday - Friday: 09:00 - 17:00 (UTC +1)

Operating Notes

Atlona AT-UHD-CAT-4ED - Operating Notes - 1

IMPORTANT: Visit http://www.atlona.com/product/AT-UHD-CAT-4ED for the latest firmware updates and User Manual.

Warranty

QR code image containing encoded data, no visible human-readable text

To view the product warranty, use the following link or QR code:

https://atlona.com/warranty/

Safety and Certification

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCT THE RISK OF

ELECTRIC SHOCK

DO NOT OPEN ENCLOSURE OR EXPOSE

TO RAIN OR MOISTURE.

NO USER-SERVICEABLE PARTS

INSIDE REFER SERVICING TO

QUALIFIED SERVICE PERSONNEL.

Atlona AT-UHD-CAT-4ED - CAUTION - 1

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the product.

Atlona AT-UHD-CAT-4ED - CAUTION - 2

The information bubble is intended to alert the user to helpful or optional operational instructions in the literature accompanying the product.

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this product near water.
  6. Clean only with a dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
  8. Do not install or place this product near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

  9. Do not defeat the safety purpose of a polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

  10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the product.
  11. Only use attachments/accessories specified by Atlona.
  12. To reduce the risk of electric shock and/or damage to this product, never handle or touch this unit or power cord if your hands are wet or damp. Do not expose this product to rain or moisture.
  13. Unplug this product during lightning storms or when unused for long periods of time.
  14. Refer all servicing to qualified service personnel. Servicing is required when the product has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the product, the product has been exposed to rain or moisture, does not operate normally, or has been dropped.

Atlona AT-UHD-CAT-4ED - CAUTION - 3

Atlona AT-UHD-CAT-4ED - CAUTION - 4

Atlona AT-UHD-CAT-4ED - CAUTION - 5

Atlona AT-UHD-CAT-4ED - CAUTION - 6

Atlona AT-UHD-CAT-4ED - CAUTION - 7

Atlona AT-UHD-CAT-4ED - CAUTION - 8

Atlona AT-UHD-CAT-4ED - CAUTION - 9

FCC Compliance

FCC Compliance and Advisory Statement: This hardware device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed or used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1) reorient or relocate the receiving antenna; 2) increase the separation between the equipment and the receiver; 3) connect the equipment to an outlet on a circuit different from that to which the receiver is connected; 4) consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Where shielded interface cables have been provided with the product or specified additional components or accessories elsewhere defined to be used with the installation of the product, they must be used in order to ensure compliance with FCC regulations.

© 2022 Atlona Inc. All rights reserved. "Atlona" and the Atlona logo are registered trademarks of Atlona Inc. Pricing, specifications and availability subject to change without notice. Actual products, product images, and online product images may vary from images shown here.

Atlona AT-UHD-CAT-4ED - Copyright, Trademark, and Registration - 1

The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI licensing Administrator, Inc.

Dolby, Dolby Atmos, and the double-D symbol are registered trademarks of Dolby Laboratories Licensing Corporation.

For DTS patents, see http://patents.dts.com. Manufactured under license from DTS, Inc. DTS, the Symbol, DTS and the Symbol together, and Digital Surround are registered trademarks and/or trademarks of DTS, Inc. in the United States and/or other countries. © DTS, Inc. All Rights Reserved.

All other trademark(s), copyright(s), and registered technologies mentioned in this document are the properties of their respective owner(s).

Table of Contents

Introduction 6

Features 6

Package Contents 6

Panel Description 7

Installation

8

Connection Instructions 8

Connection Diagram 9

IP Configuration 10

Setting the IP Mode 10

Setting the IP Address Using Commands 10

Setting the IP Address using the Web Server 11

Device Operation 12

LED Indicators 12

Locking the Front Panel 13

Using the Front Panel 13

Using the web server 13

EDID Management 14

Learning an EDID using the Front Panel 14

Learning the EDID using the web server 15

Locking the EDID 15

Selecting EDID Presets 16

Managing Users 17

Adding Users 17

Editing / Deleting Users 18

RS-232 Control 19

Determining the Port Type 19

Cable Assembly 20

Pass-through mode 21

Control mode 22

IR Control 23

Controlling Display Devices 23

Controlling Source Devices 24

Power Button Modes 25

Normal Operation 25

Powering Sink Devices 26

Powering Sinks and the AT-UHD-CAT-4ED 28

The Web Server

Introduction to the Web Server 29

Info page 31

RS-232 page 32

EDID page 33

Config page 34

System page 35

Appendix

Updating the MCU Firmware 37

Using the Web Server 37

Using USB 38

Updating the Valens Firmware 39

Using the Web Server 39

Using USB 40

Cable Termination 41

Default Settings 42

Specifications 43

Introduction

The Atlona AT-UHD-CAT-4ED distribution amplifier featuring pass-through HDMI input connections, four extended distance, Ethernet-enabled HDBaseT outputs and display control capability. Each output transmits AV and control signals up to 330 ft. (100 m). Features include 4K/UHD @ 60 Hz with 4:2:0 color subsampling, HDCP 2.2 compliance, EDID management, and PoE for powering remote receivers. A wide variety of consumer displays may be controlled by the UHD-CAT-4ED using CEC*. Designed for commercial distribution applications, the UHD-CAT-4ED is control system-friendly and integrates with any TCP/IP, RS-232, or IR control system and features a 1U, half-rack width enclosure with external, international power supply. Compatible Atlona receiver: AT-UHD-EX-100CE-RX.

Features

• HDMI distribution amplifier with built-in HDBaseT transmission
- Four HDBaseT outputs for transmission of HDMI, Ethernet, and control up to 330 feet (100 meters)
• 4K/UHD capability with HDCP 2.2 copy protection
• Power over Ethernet (PoE) for HDBaseT receivers
- CEC display control
• Multi-channel audio compliant
• EDID management
- Intuitive GUI-based configuration using integrated web server
• TCP/IP, RS-232, and IR control
- Easy to configure and manage with AMS (Atlona Management System)
• Field-updatable firmware
- Front panel power and signal status LEDs
- Rack-mountable 1U, half rack width enclosure
- Award-winning 10 year limited product warranty

Package Contents

1 x AT-UHD-CAT-4ED
1 x IR emitter (AT-IR-CS-TX)
3 x 5-pin captive screw connector
2 x Mounting Plates
1 x Rack Ear (long)
1 x Rack Ear (short)
4 x Screws (MAS-MF03+04D1 for Mounting Plate)
4 x Screws (MAS-MF04+06D for Rack Ear)
1 x 48 V / 2.08 A power supply
1 x AC cord
1 x Installation guide

*Consumer Electronics Control (CEC): Atlona has confirmed proper CEC functionality with several current models of Samsung, Panasonic, and Sony displays. However, it is not guaranteed that CEC will work with all displays. Many manufacturers do not support the CEC "off" command, and older displays use proprietary commands. Atlona only supports displays that use the CEC command structure defined in HDMI 1.2a. It is recommended that dealers request an evaluation product from Atlona, before designing a system using the CEC protocol. If this is not possible, then other control methods will need to be considered, in order to control displays using Atlona products.

Panel Description

ATLONA® HDMI HDBaseT LOCK IN 2 3 5 7 4321OUT INT LEARN AT-UHD-CAT-4ED EDIDPOVEH HDMI 9 11 12 14 MASTER RS-232 IR RS-232 IR RS-232 IR RS-232 IR RS-232 IR FW LAN TX TKRX RX TX TKRX RX TX TKRX RX TX TKRX RX TX TKRX RX TX TKRX RX IN HDMI OUT 1 2 3 4 DC 48V 8 10 13 15

1 HDMI Indicators

Displays the status of the HDMI IN and HDMI OUT ports. When connected to a source or display (sink) device, respectively, the LED indicator will be blue.

2 HDBaseT Indicators

Displays the status of the HDBaseT OUT ports. When connected to an HDBaseT receiver, the LED indicator will be blue.

3 Lock

This LED will be blue when the unit is locked.

4 POWER

Press this button to power-on or place the unit into standby mode.

5 INT

This LED indicator will be blue when the unit is using an internal EDID.

6 EDID

Press this button to switch between the internal (INT) and learned (LEARN) EDID modes.

7 LEARN

This LED indicator will flash when a downstream EDID is being read into memory.

8 HDMI IN

Connect an HDMI cable from this port to a source device.

9 LAN

Connect an Ethernet cable from this port to the network.

10 HDMI OUT

Connect an HDMI cable from this port to a confidence monitor.

11 RS-232 / IR (MASTER)

Connect a control system to this port to control the AT-UHD-CAT-4ED.

12 RS-232/IR 1 - 4

Connect a control system or other DTE device to these ports for pass-through zone control. Each of these ports uses the associated HDBaseT OUT port. This allows RS-232 command data to be sent to a display (sink) device connected to a PoE-comptible receiver.

13 HDBaseT OUT 1 - 4

Connect Ethernet cables from these ports to PoE-compatible receivers.

14 FW

Connect a mini USB-to-USB cable from this port, to a computer, to update the firmware of the AT-UHD-CAT-4ED.

15 DC 48V

Connect the included power supply to this power receptacle.

Installation

Connection Instructions

  1. Connect an HDMI cable from a UHD/HD source to the HDMI IN port.
  2. Connect an HDMI cable from the HDMI OUT port to a display (sink) device.

  3. Connect up to four Ethernet cables from the HDBaseT OUT ports to compatible PoE-capable receivers. Refer to the table below for information on maximum cable length and supported resolutions.

Atlona AT-UHD-CAT-4ED - Connection Instructions - 1

IMPORTANT: Stranded or patch cable is not recommended due to performance issues. Sheilded cables are strongly recommended to minimize signal noise and interference.

Cable 4K/UHD - Feet / Meters 1080p - Feet / Meters
HDMI 15 5 30 10
CAT5e/6 230 70 330 100
CAT6a/7 330 100 330 100
  1. Connect an Ethernet cable from the LAN port to the Local Area Network (LAN). This step will be required in order to access the built-in web server.
  2. Connect the included power supply to the DC 48V connector and connect the power cord to an available electrical outlet.
  3. Connect an RS-232 or IR cable from the control system to the RS-232/IR ports. Refer to RS-232 Control (page 19) and IR Control (page 23) for more information.

  4. MASTER RS-232/IR
    Connecting to this port will provide direct control of the AT-UHD-CAT-4ED using a control system. Control can be performed using either RS-232 or electrical IR.
    • RS-232/IR 1 through RS-232/IR 4
    Each of these ports is associated to the respective HDBaseT OUT port. This allows RS-232 pass-through zone control of a display (sink) device that is connected to a PoE-compatible receiver. Control can be performed using RS-232 or electrical IR.

Installation

Connection Diagram
Atlona AT-UHD-CAT-4ED - Installation - 1

flowchart
graph TD
    A["AT-UHD-CAT 4ED"] -->|HDMI| B["Laptop"]
    A -->|HDBaseT| C["AT-UHD-EX-70C-RX"]
    A -->|HDBaseT| D["AT-UHD-EX-70C-RX"]
    A -->|HDBaseT| E["Display"]
    F["LAN"] -->|Ethernet| A
    G["AT-UHD-EX-70C-RX"] -->|HDMI| H["Display"]
    I["AT-UHD-EX-70C-RX"] -->|HDMI| J["Display"]
    K["AT-UHD-EX-70C-RX"] -->|HDMI| L["Display"]
    M["AT-UHD-EX-70C-RX"] -->|HDMI| N["Display"]
    O["AT-UHD-EX-70C-RX"] -->|HDMI| P["Display"]
    Q["AT-UHD-EX-70C-RX"] -->|HDMI| R["Display"]
    S["Display"] --> T["Internet"]
    U["Display"] --> V["Internet"]

IP Configuration

The AT-UHD-CAT-4ED is shipped with DHCP enabled. Once connected to a network, the DHCP server (if available), will automatically assign an IP address to the unit. Use an IP scanner, along with the MAC address on the back of the unit, to identify both the unit and its IP address on the network. If a static IP address is desired, the unit can be switched to static IP mode. Use one of the following procedures to switch between DHCP and static IP mode. The default static IP address of the AT-UHD-CAT-4ED is 192.168.1.254.

If the AT-UHD-CAT-4ED is unable to detect a DHCP server within 15 seconds, then the unit will set all IP settings to zero.

Atlona AT-UHD-CAT-4ED - IP Configuration - 1

IMPORTANT: If the AT-UHD-CAT-4ED is receiving a DHCP IP address, and the IP mode is changed to static, then Telnet and web server communication will be lost.

Setting the IP Mode

  1. Make sure the AT-UHD-CAT-4ED is powered.
  2. Connect an Ethernet cable between the LAN port of the AT-UHD-CAT-4ED and the Local Area Network (LAN).
  3. Press and hold the POWER button for approximately 15 seconds. Release the POWER button once the LOCK LED indicator begins to flash. The number of flashes will indicate the currently selected IP mode.

ATLONA® HDMI IN HDBaseT OUT 4321 LOCK LED indicator LOCK INT LEARN POWER button POWER EDID HDMI

POWER button flashesDescription
TwoStatic IP modeIP address: 192.168.1.254Netmask: 255.255.0.0Gateway: 192.168.1.1
FourDHCP mode

Setting the IP Address Using Commands

Use the IPStatic and IPDHCP commands to switch between DHCP and IP mode through RS-232 or Telnet. Refer to API documentation for more information. All commands and their arguments are case-sensitive.

Atlona AT-UHD-CAT-4ED - Setting the IP Address Using Commands - 1

IMPORTANT: Note that when switching between DHCP and static modes, within a Telnet session, the connection will be terminated once the IPDHCP command is executed.

- Setting static IP mode

  1. Connect to the AT-UHD-CAT-4ED using RS-232 or Telnet.
  2. At the command line, execute the IPDHCP command using the off argument, as shown.

IPDHCP off

Installation

  1. Execute the IPStatic command. This command requires three arguments: the desired IP address of the AT-UHD-CAT-4ED, the subnet mask, and the gateway address. All arguments must be entered in dot-decimal notation. The following is an example:

IPStatic 192.168.1.112 255.255.255.0 192.168.1.1

IP address Subnet mask Gateway

- Setting DHCP mode

  1. Connect to the AT-UHD-CAT-4ED using RS-232 or Telnet.

  2. At the command line, execute the IPDHCP command using the on argument, as shown. All characters are case-sensitive.

IPDHCP on

Once DHCP is enabled, the unit will be assigned an IP address by the DHCP server (if present).

Setting the IP Address using the Web Server

The System page (page 35), in the web server, allows the AT-UHD-CAT-4ED to use either DHCP or static IP mode. In order to access the web server, the IP address of the AT-UHD-CAT-4ED must be known. Refer to Introduction to the Web Server (page 29).

  1. Open the desired web browser and enter the IP address of the AT-UHD-CAT-4ED.
  2. Log in using the required credentials. The factory-default username and password are listed below:

Username: root

Password: Atlona

  1. Click System in the menu bar.
  2. Click the IP Mode toggle to switch between the DHCP and STATIC IP setting. When set to STATIC IP, the IP, Netmask, and Gateway fields can be modified.

IP Mode:

STATIC IP

IP:

10.20.200.121

Netmask:

255.255.255.0

Gateway:

10.20.200.2

Telnet Port:

23

  1. Click the Save button to save the changes.

Device Operation

LED Indicators

The LED indicators on both the front of the unit provide basic information on the current status of the AT-UHD-CAT-4ED.

LED Description
POWER BlueUnit is powered and in normal operating mode.
Red Unit is in standby mode.Press the POWER button to place the unit in normal operating mode.
Off Unit is not powered.Check the power supply and make sure it is securely fastened to the locking connector on the rear of the unit.Make sure that the power supply is connected to an available electrical outlet and that the outlet is “live” (some outlets are controlled by a wall switch).
HDMI IN / OUTBlue IN: Source is connected to the HDMI IN port.OUT: Sink device is connected to the HDMI OUT port.
Off IN: No source device connected to the HDMI IN port.OUT: No sink device is connected to the HDMI OUT port.
HDBaseT 1 - 4Blue Normal operation. Signal integrity between the AT-UHD-CAT-4ED and the connected receiver is good.
Off No connection between the HDBaseT port on the AT-UHD-CAT-4ED and the receiver unit.
LOCK Blue Front-panel buttons of the AT-UHD-CAT-4ED are locked. Refer to the API or Locking the Front Panel (page 13) for more information.
Flashing Blue The number of flashes indicate whether the unit is in DHCP or static IP mode. Refer to IP Configuration (page 10) for more information.
Off Front-panel buttons on the AT-UHD-CAT-4ED are unlocked.
INT Blue AT-UHD-CAT-4ED is using the internal EDID.
Off EDID is in “learn” mode.
LEARN Blue AT-UHD-CAT-4ED is in “learn” mode. Refer to EDID Management (page 14) for more information.
Flashing Blue AT-UHD-CAT-4ED is in the process of learning the downstream EDID.
Off AT-UHD-CAT-4ED is set to INT (internal EDID) mode.

Locking the Front Panel

The buttons on the front panel can be locked or unlocked. Locking the front-panel buttons prevents accidental pressing of the buttons, which may occur when the unit is mounted in a rack environment. Locking and unlocking of the front-panel buttons is managed through the web server or by executing the Lock and Unlock API commands. Refer to the API documentation for more information.

Atlona AT-UHD-CAT-4ED - Locking the Front Panel - 1

NOTE: Locking the front-panel buttons will also lock the EDID, preventing the EDID mode from being switched between INT and LEARN modes.

Using the Front Panel

  1. Make sure the unit is powered.
  2. Press and hold the POWER button for five seconds.

  3. Release the POWER button. The LOCK LED indicator on the front panel will glow solid blue. The front panel buttons are now locked.

  4. To unlock the front-panel buttons, press and hold the POWER button for five seconds, then release. The LOCK LED indicator will no longer be illuminated.

ATLONA® - HDMI HDBaseT IN LOCK 4321OUT INT LEARN POWER button HDMI

Using the web server

  1. Login to the web server. Refer to Introduction to the Web Server (page 29) for more information.
  2. Click System in the menu bar.
  3. Locate the System section and click the Lock toggle button to switch between LOCK and UNLOCK states.

System Power ON Lock UNLOCK

System Power ON Lock LOCK

  1. The LOCK LED indicator, on the front panel, will reflect the current state. When the front-panel buttons are locked, the LOCK LED indicator will glow solid blue.

EDID Management

The AT-UHD-CAT-4ED provides two EDID modes: INT and LEARN. The default EDID mode is INT mode. In this mode, the AT-UHD-CAT-4ED will automatically create an EDID based on the capabilities of all connected displays. INT mode is recommended for the best results when the capabilities of all connected displays are unknown. INT mode can also be used to select any of 16 EDID presets. Refer to Selecting EDID Presets (page 16) for more information on this topic. LEARN mode can be used to capture an EDID from any sink device. Once the EDID is learned, it will be used by the connected source device to determine what video and audio formats can be sent to the sink device.

Learning an EDID using the Front Panel

  1. Power the AT-UHD-CAT-4ED.
  2. Connect an Ethernet cable from the HDBaseT OUT 1 port on the AT-UHD-CAT-4ED to a receiver (e.g. AT-UHD-EX-100CE-RX).
  3. Connect an HDMI cable from the receiver to the display (sink) device. Make sure that the sink device is powered.

Atlona AT-UHD-CAT-4ED - Learning an EDID using the Front Panel - 1

flowchart
graph TD
    A["AT-UHD-CAT-4ED"] -->|HDMI=1 OUT 1| B["AT-UHD-EX-100CE-RX"]
    B -->|HDMI| C["Display"]
  1. Press and hold the EDID button on the AT-UHD-CAT-4ED. Release the EDID button once the LEARN LED indicator begins to flash rapidly.

ATLONA® HDMI IN OUT HDBaseT 1 2 3 4 LOCK INT LEARN AT-UHD-CAT-4ED POWER EDID HDMI

Once the EDID is learned, it will be used by the connected source device to determine what video and audio formats can be sent to the sink device(s). To switch back to INT mode, quickly press and release the EDID button.

Atlona AT-UHD-CAT-4ED - Learning an EDID using the Front Panel - 3

NOTE: If the AT-UHD-CAT-4ED is accidentally switched to INT mode, quickly press and release the EDID button to switch back to LEARN mode. Switching back and forth between INT and LEARN mode will not erase the "learned" EDID.

Learning the EDID using the web server

  1. Follow steps 1 through 3 under Learning an EDID using the Front Panel (page 14).
  2. Login to the web server. Refer to Introduction to the Web Server (page 29) for more information.
  3. Click EDID in the menu bar.

Edid Edid lock UNLOCK Edid mode INT INT Edid settings INT Edid copy LEARN

  1. Click the EDID mode drop-down list and select LEARN.
  2. Click the COPY button to copy the downstream EDID to memory.

The AT-UHD-CAT-4ED will now use the EDID of the downstream sink. To switch back to the INT mode, click the EDID mode drop-down list and select INT.

Locking the EDID

To prevent accidental switching between INT and LEARN modes, the EDID can be locked.

Atlona AT-UHD-CAT-4ED - Locking the EDID - 1

NOTE: Locking the EDID will also lock all front-panel buttons.

  1. Login to the web server. Refer to Introduction to the Web Server (page 29) for more information.
  2. Click EDID in the menu bar.
  3. Click the EDID lock toggle button to switch between LOCK and UNLOCK states.

Edid Edid lock Edid mode LEARN INT Edid settings STD Edid copy UNLOCK COPY

Edid Edid lock Edid mode INT Edid settings Edid copy LOCK LEARN STD COPY

  1. The LOCK LED indicator, on the front panel, will reflect the current state. When the EDID is locked, the LOCK LED indicator will glow solid blue. This also serves to indicate that all front-panel buttons are locked.

Device Operation

Selecting EDID Presets

The AT-UHD-CAT-4ED comes with a default EDID plus 16 pre-programmed EDID selections. When selecting the default or one of the pre-programmed EDID selections, the EDID mode must be set to INT (internal) mode. Available EDID selections are presented in the table below.

EDID
STD ATL 1280x800 RGB 2CH
ATL 1080P 2CH ATL 1366x768 RGB 2CH
ATL 1080P Multi CH ATL 1080P DVI
ATL 1080P DD ATL 1280x800 RGB DVI
ATL 1080P 3D 2CH ATL 3840x2160@30 2CH
ATL 1080P 3D Multi CH ATL 3840x2160@30 Multi CH
ATL 1080P 3D DD ATL 3840x2160@60 2CH
ATL 720P 2CH ATL 3840x2160@60 Multi CH
ATL 720P DD

Atlona AT-UHD-CAT-4ED - Selecting EDID Presets - 1

NOTE: If the resolution and timing limitations of all displays, connected to the HDBaseT OUT ports, are unknown, then select the STD EDID for the best compatibility. The STD EDID will automatically build an EDID based on the capabilities of all connected displays. When selecting an EDID, make sure all connected displays can support the resolution and timing information. Otherwise, loss of picture and/or audio may result.

  1. Login to the web server. Refer to Introduction to the Web Server (page 29) for more information.
  2. Click EDID in the menu bar.
  3. Make sure the EDID lock toggle switch is set to UNLOCK.
  4. Click the EDID mode drop-down list and select INT.
  5. Select the desired EDID from the INT EDID settings drop-down list.

The selected EDID will be used by the source, before sending A/V data to the display (sink) device.

Edid Edid lock UNLOCK Edid mode INT INT Edid settings STD Edid copy STD ATL 1080P 2CH ATL 1080P Multi CH ATL 1080P DD ATL 1080P 3D 2CH ATL 1080P 3D Multi CH

Managing Users

The AT-UHD-CAT-4ED allows the admin user to create, edit, and remove additional TCP/IP users. All users have the same level of access to control the AT-UHD-CAT-4ED. However, only the admin user is allowed to manage other users. Up to three additional users can be created.

Adding Users

  1. Open the desired web browser and enter the IP address of the AT-UHD-CAT-4ED.
  2. Log in as the admin user with the required credentials. The factory-default username and password for the admin user are listed below:

Username: root

Password: Atlona

ATLONA a Rocket company Add Add Add Add Configuration Web & Telnet Login Settings Old Username: Old Password: New Username: New Password: Confirm New Password: All User Login Settings Username: Password: Add Remove Add Remove Add Remove

  1. Click the Config tab.
  2. Click the Add button, under the Edit column.

Username&Password Edit Username minion1 Password 12345678 Save Change Cancel

  1. Enter the desired username and password in the Username&Password Edit dialog box.
  2. Click the Save Change button to commit changes or click the Cancel button to return to the Config page without adding the user.

Once created, the new user and the associated password will appear under the All User Login Settings section. To login with the new username, click Logout in the upper-right corner of the screen, then enter the login credentials for the user on the Login page.

Editing / Deleting Users

The username and password of a user can be changed using this method.

  1. Open the desired web browser and enter the IP address of the AT-UHD-CAT-4ED.
  2. Log in as the admin user with the required credentials. The factory-default username and password for the admin user are listed below:

Username: root

Password: Atlona

ATLONA a Telnet company Web 103-212 12:00 System Configuration Web & Telnet Login Settings Old Username: New Password: New Username: New Password: Cardless New Password: Send All User Login Settings Session: Password: CD40/79 Add Remove Add Remove Add Remove

Editing Users

a. Click Config in the menu bar.
b. Click the Edit button next to the user to be changed.
c. Enter the new information for the user in the Username&Password Edit dialog box.
d. Click the Save Change button to commit changes or click the Cancel button to return to the Config page without making changes.

Username&Password Edit Username minion2 Password 12345678 Save Change Cancel

Deleting Users

a. Click the Remove button next to the user to be deleted.

RS-232 Control

The AT-UHD-CAT-4ED provides two methods of RS-232 control: Pass-through mode and control mode. The master RS-232 / IR port, allows the unit to be directly controlled using a control system. In addition four pass-through RS-232 / IR ports allow sink devices, at the viewing location, to be controlled using a control system.

RS-232 is serial data protocol that allows Data Terminal Equipment (DTE) devices, such a computer or control system, to communicate with Data Communication Equipment (DCE) devices, such as the AT-UHD-CAT-4ED or a display. Although IP control is available, RS-232 still plays an integral part of many control systems.

The 25-pin D-type connector (DB-25) was defined as the RS-232 standard, but is now commonly implemented in a nine-pin (DE-9) connector package. Each pin is numbered, as shown below.

DE-9 (male) DE-9 (female)
12345 6789

54321 9876

DTE Pin Descriptions

Pin Signal Description
1 DCDData CarrierDetect
2 RxDReceive Data
3 TxDTransmit Data
4 DTRData Terminal Ready
5 GNDGround (Signal)
6 DSRData Set Ready
7 RTSRequest to Send
8 CTSClear to Send
9 RIRingIndicator

DCE Pin Descriptions

Pin Signal Description
1 DCDData CarrierDetect
2 TxDTransmit Data
3 RxDReceive Data
4 DSRData Set Ready
5 GNDGround (Signal)
6 DTRData Terminal Ready
7 CTSClear to Send
8 RTSReady to Send
9 RIRing Indicator

Determining the Port Type

Most DTE devices provide a male connector, while DCE devices have a female connector. However, this is not always the case. If the port type is unknown, then a multimeter can be used to determine whether the port is DTE or DCE:

  1. Turn on the multimeter and set it to measure DC voltage.
  2. Connect the positive and negative leads to pins 3 and 5, respectively.
  3. Check the voltage reading:

If the voltage is between -3 V DC and -15 V DC, then the device is DTE. Otherwise, it is DCE.

Voltage levels between -3 V and -15 V DC represent a logic "1". Voltage levels between +3 V and +15 V DC represent a logic "0".

-12 V Multimeter 1 2 345 6789

Device Operation

Cable Assembly

When connecting a DTE device to a DCE device, a straight-through cable should be used. A straight-through cable is wired in such a way that the pins on one side of the cable are connected to the corresponding pins on the opposite side of the cable, as shown in the table below. However, the AT-UHD-CAT-4ED will use only TxD, RxD, and GND signals when communicating with a control system or computer.

Straight-Through Cable

PinSignalSignalPin
1DCDDCD1
2RxDTxD2
3TxDRxD3
4DTRDSR4
5GNDGND5
6DSRDTR6
7RTSCTS7
8CTSRTS8
9RIRI9
  1. Identify the DE-9 connector that will be attached to the control system or computer (DCE) equipment.
  2. Remove the DE-9 connector at the opposite end of the cable with wire cutters.
  3. Remove at least 1" of the cable insulation to expose each of the nine wires.
  4. Locate a multimeter and set it to the "continuity" function.
  5. Attach one of the leads from the multimeter to pin 2 on the DE-9 connector.
  6. Take the other lead and probe each of the wires on the opposite end of the cable. When the wire connected to that pin is detected, the multimeter will emit an audible tone. Once this occurs, identify the current wire, and move it to the side.
  7. Repeat step 6 for pin 3 and pin 5 on the DE-9 connector.
  8. Group the remaining wires and pull them aside. Electrical tape can be use to secure the wires to the outside of the RS-232 cable.
  9. Remove at least 3/16" (5 mm) of insulation from the TxD, RxD, and GND wires.

MASTER RS-232 IR LAN TX T/RX RX 1 RS-232 IR TX T/RX RX TX T/RX RX F

als by GND TXD RXD

  1. Locate the included 5-pin captive screw block and open each of the terminals by turning the screws counter-clockwise, using a small regular screwdriver.
  2. Insert the TxD, RxD, and GND wires into correct terminal, as shown, and tighten the screws to secure each wire. Do not overtighten.

Device Operation

Pass-through mode

In pass-through mode, RS-232 commands are passed-through the AT-UHD-CAT-4ED, transmitted over HDBaseT to a receiver unit, and then to the display (sink) device. Note that each RS-232 / IR port is assigned to an HDBaseT OUT port. This assignment is fixed and cannot be changed, as shown in the table below.

RS-232 / IR Port HDBaseT Port RS-232 / IR Port HDBaseT Port
RS-232 / IR 1HDBaseT OUT 1RS-232 / IR 3HDBaseT OUT 3
RS-232 / IR 2HDBaseT OUT 2RS-232 / IR 4HDBaseT OUT 4
  1. Connect the RS-232 cable from the control system to the desired RS-232 / IR port on the AT-UHD-CAT-4ED. Refer to Cable Assembly (page 20) for instructions on preparing the cable.
  2. Connect an Ethernet cable from the desired HDBaseT OUT port to a receiver. In this example, the HDBaseT cable is connected from HDBaseT OUT 2 to an AT-UHD-EX-100CE-RX receiver (the RS-232 cable is connected from the control system to the RS-232 / IR 2 port).
  3. Connect an RS-232 cable between the display (sink) and the receiver.
  4. Adjust the RS-232 settings on the control system to match the requirements of the sink device. For example, if the RS-232 settings for the display device are 9600, N, 8, 1, then set the control system to the same settings. If the control system and sink device settings do not match, then RS-232 control will not function.

Atlona AT-UHD-CAT-4ED - Pass-through mode - 1

flowchart
graph TD
    A["Control System"] -->|RS-232 (RS-232 / R-2)| B["AT-UHD-CAT-4ED"]
    B -->|HDBsetT (HDBsetT OUT 2)| C["AT-UHD-EX-100CE-RX"]
    C -->|RS-22| D["Display"]

Device Operation

Control mode

In control mode, the MASTER RS-232 / IR port is used to directly control the AT-UHD-CAT-4ED using a control system.

  1. Launch a web browser and login to the web server. Refer to Introduction to the Web Server (page 29) for more information. The factory-default username and password are listed below:

Username: root

Password: Atlona

  1. Connect the RS-232 cable between the control system and the MASTER RS-232 / IR port on the AT-UHD-CAT-4ED. Refer to Cable Assembly (page 20) for instructions on preparing the cable.

Atlona AT-UHD-CAT-4ED - Control mode - 1

flowchart
graph LR
    A["Control System"] -->|RS-32| B["AT-UHD-CAT-4ED"]
  1. Click RS-232 in the menu bar.
  2. Select the proper baud rate, data bit, parity, and stop bit settings. These settings must correspond with the control system RS-232 settings.

ATLONA a Resort company File Edit View Insert Modify System RS-232 RS-232 Parameter Setting Console Baud rate 115200 Data bit 6 Parity None Stop bit 1 New RS-232 Parameter Setting Console Baud rate 115200 Data bit 8 Parity None Stop bit 1 Save

  1. Click the Save button to commit changes.

IR Control

IR can be used to control either source devices at the headend or devices connected to the receiver endpoint, such as a display. Note that the MASTER RS-232 / IR port does not support IR control. Note that each RS-232 / IR port is assigned to an HDBaseT OUT port. This assignment is fixed and cannot be changed, as shown in the table below. IR is compatible with frequencies from 30 kHz to 60 kHz.

RS-232 / IR PortHDBaseT PortRS-232 / IR PortHDBaseT Port
RS-232 / IR 1HDBaseT OUT 1RS-232 / IR 3HDBaseT OUT 3
RS-232 / IR 2HDBaseT OUT 2RS-232 / IR 4HDBaseT OUT 4

Controlling Display Devices

  1. Remove at least 3/16" (5 mm) of insulation from the TX and GND wires.
  2. Locate the included 5-pin captive screw block and open each of the terminals by turning the screws counterclockwise, using a small regular screwdriver.
  3. Insert the TX and GND wires into correct terminal, as shown, and tighten the screws to secure each wire. Do not overtighten.
  4. Connect the captive screw connector to the RS-232 / IR IN port of the zone to be controlled.
  5. Connect the RX terminal, from the AT-UHD-CAT-4ED, to the TX terminal on the control system.
  6. Connect the GND terminal, from the AT-UHD-CAT-4ED, to the GND terminal on the control system.

RS-232 1 IR TX T8RX RX RS-232 2 IR TX T8RX RX RS-232 3 IR TX T8RX RX RS-232 4 IR TX T8RX RX

AT-UHD-CAT-4ED GND P1 Control System P2 GND

  1. Connect the IR emitter to the receiver and place the emitter next to the display (sink) device, as shown in the illustrator below.

Atlona AT-UHD-CAT-4ED - Controlling Display Devices - 3

flowchart
graph TD
    A["Control System"] -->|IR (RS-232/IR 1)| B["AT-UHD-CAT-4ED"]
    B -->|HDBaseT (HDBaseT OUT 1)| C["AT-UHD-EX-100CE-RX"]
    C -->|IR Emitter| D["Display"]
    B -->|IR Signal| E["Output"]

Device Operation

Controlling Source Devices

  1. Remove at least 3/16" (5 mm) of insulation from the RX and GND wires of the emitter.
  2. Locate the included 5-pin captive screw block and open each of the terminals by turning the screws counterclockwise, using a small regular screwdriver.
  3. Insert the S (signal) lead of the IR emitter to the TX terminal on the AT-UHD-CAT-4ED captive screw connector. Tighten the screw to secure the wire but do not overtighten.
  4. Insert the GND lead of the IR emitter to the GND terminal on the AT-UHD-CAT-4ED captive screw connector. Tighten the screw to secure the wire but do not overtighten.
  5. Connect the captive screw connector to the RS-232 / IR IN port of the zone to be controlled.

RS-232 1 IR RX TX TX RX RS-232 2 IR RX TX TX RX RS-232 3 IR RX TX TX RX RS-232 4 IR RX TX TX RX

AT-UHD-CAT-4ED GND GND s IR Emitter ion below.

  1. Place the IR emitter next to the source device, as shown in the illustration below.

Atlona AT-UHD-CAT-4ED - Controlling Source Devices - 3

flowchart
graph LR
    A["Blu-ray Player"] -->|IR Emitter (RS-232/IR 1)| B["AT-UHD-CAT-4ED"]
    B -->|HDbase (HDbase OUT 1)| C["AT-UHD-EX-100CE-RX"]
    C -->|IR Receiver| D["Blu-ray Player IR Remote"]
    D -->|IR Signal| A

Power Button Modes

The main function of the POWER button on the front panel is to toggle the AT-UHD-CAT-4ED between standby and normal operating mode. This is the default mode. However, this button can also be defined to send CEC power-on and power-off commands, over HDBaseT, to the display (sink) devices. It can also be defined to simultaneously power-on or power-off the AT-UHD-CAT-4ED and any connected displays.

Normal Operation

By default, pressing the POWER button will toggle the power state of the AT-UHD-CAT-4ED. When the unit is in normal operating mode, the POWER button will be blue. Pressing the POWER button again, will place the unit into standby mode, and the POWER button will be red. In standby mode, no video signal will pass to the display (sink) device. However, TCP/IP access to the unit will be maintained, allowing access to the web server and Telnet sessions.

  1. Launch a web browser and login to the web server. Refer to Introduction to the Web Server (page 29) for more information. The factory-default username and password are listed below:

Username: root

Password: Atlona

  1. Click System in the menu bar.
  2. Click the Power button mode drop-down list and select DA standby. Pressing the POWER button on the front panel will toggle between power-on and standby modes on the AT-UHD-CAT-4ED. Connected display (sink) devices will not receive CEC power-on / power-off messages.

ATLONA a Power company Info 03-232 CD32 Coding System Network IP Node: 1000000 SH: 875.46 Network: 0000000 Gateway: 875.46 Timeout Port: 0 Timeout Login Mode Twinet Timeout Timeout: 128 Broadcast: Cca System Power One Lock GNC Dcmm Power button mode DA standby DA standby CEC Both Choose File No file chosen Valero Update Choose File No file chosen CEC Power OK Power button mode DA standby DA standby CEC Both Choose File No file chosen Update

Device Operation

Powering Sink Devices

This section provides information on how to power-on / power-off the display (sink) device, using the POWER button. CEC* power-on / power-off commands are transmitted over all HDBaseT OUT ports, as well as the pass-through HDMI OUT port.

  1. Connect Ethernet cables from the HDBaseT OUT ports to receiver (e.g. AT-UHD-EX-100CE-RX).
  2. Connect an HDMI cable from the receiver to the display (sink) device. Make sure that the sink device is powered.

Atlona AT-UHD-CAT-4ED - Powering Sink Devices - 1

flowchart
graph TD
    A["AT-UHD-CAT-4ED"] -->|HDReset Quit| B["AT-UHD-EX-100CE-RX"]
    B -->|HDMI| C["Display"]
  1. Launch a web browser and login to the web server. Refer to Introduction to the Web Server (page 29) for more information. The factory-default username and password are listed below:

Username: root

Password: Atlona

  1. Click System in the menu bar.

  2. Click the Power button mode drop-down list and select CEC. Refer to the illustration on the next page for reference.

*Consumer Electronics Control (CEC): Atlona has confirmed proper CEC functionality with several current models of Samsung, Panasonic, and Sony displays. However, it is not guaranteed that CEC will work with all displays. Many manufacturers do not support the CEC "off" command, and older displays use proprietary commands. Atlona only supports displays that use the CEC command structure defined in HDMI 1.2a. It is recommended that dealers request an evaluation product from Atlona, before designing a system using the CEC protocol. If this is not possible, then other control methods will need to be considered, in order to control displays using Atlona products.

Device Operation

ATLONA a Power company File Edit Edit Change Com Buy Spoker Network IP Mode: 100007 Up: 62.54 Network: 89.38/2000 Gateway: 62.54 Select Port: 0 Telet Login Mode Up Telet Timeout: 120 Broadcast: Up System Power Up Lock CALMOS Power button mode Data visibility R Data standby F1 Both Choose File No file chosen Downs Valens Update Choose File No file chosen CEC Power Up Power button mode DA standby R DA standby CEC F Both Choose File No file chosen Update

  1. Test the CEC power-on and power-off commands by pressing the ON and OFF buttons, near the bottom of the page.

CEC Power ON OFF

  1. Press the POWER button on the front panel to power-on or power-off the display. Note that the power state of the AT-UHD-CAT-4ED will be unaffected.

Powering Sinks and the AT-UHD-CAT-4ED

In this mode, the POWER button will power-on / power-off the unit and the connected displays. CEC* power-on / power-off commands are transmitted over all HDBaseT OUT ports.

  1. Make the proper connections by following steps 1 through 4, under Powering Sink Devices (page 26).
  2. Click the Power button mode drop-down list and select Both.

ATLONA a Power company Info NO-230 CCDC Config System Network IP Node: 12.000 IP: 87.5.46 Network: 20.000.000 Gateway: 10.000.000 Telnet Port: 81 Telnet Logit Node Signal Telnet Timewout: GDS Broadcast System Power Lock Power button mode Data standby R Data standby CEC Both Select File, No file chosen Update Valens Update Select File, No file chosen Power button mode DA standby DA standby CEC F Both Choose File No file chosen Update

  1. Test the CEC power-on and power-off commands for the display (sink) device by pressing the ON and OFF buttons, near the bottom of the page.

CEC Power ON OFF

  1. Press the POWER button on the front panel to power-on or power-off both the display and AT-UHD-CAT-4ED.

*Consumer Electronics Control (CEC): Atlona has confirmed proper CEC functionality with several current models of Samsung, Panasonic, and Sony displays. However, it is not guaranteed that CEC will work with all displays. Many manufacturers do not support the CEC "off" command, and older displays use proprietary commands. Atlona only supports displays that use the CEC command structure defined in HDMI 1.2a. It is recommended that dealers request an evaluation product from Atlona, before designing a system using the CEC protocol. If this is not possible, then other control methods will need to be considered, in order to control displays using Atlona products.

The Web Server

Introduction to the Web Server

The AT-UHD-CAT-4ED includes a built-in web server. Atlona recommends that the web server be used to set up the AT-UHD-CAT-4ED, as it provides intuitive management of all features.

The AT-UHD-CAT-4ED is shipped with DHCP enabled. Once connected to a network, the DHCP server will automatically assign an IP address to the unit. Use an IP scanner to determine the IP address of the AT-UHD-CAT-4ED. If a static IP address is desired, refer to IP Configuration (page 10). The default static IP address of the AT-UHD-CAT-4ED is 192.168.1.254.

  1. Launch a web browser.
  2. In the address bar, type the IP address of the AT-UHD-CAT-4ED.
  3. The Login page will be displayed.

ATLONA Consulting Technology Lapn Username Password Submit

  1. Type root, using lower-case characters, in the Username field.

  2. Type Atlona in the Password field. This is the default password. The password field is case-sensitive. When the password is entered, it will be masked. The password can be changed, if desired. Refer to the Config page (page 34) for more information.

  3. Click the Submit button or press the ENTER key on the keyboard.

Login Username root Password .......... Submit

  1. The Info page will be displayed.

ATLONA Samsung Technology 90.000 TYPE Config Solver Login Info Model Name: AT UND-CX7-403 Software Version: YLE8B Output 1 VALIDNS Version: YLC11.5 Output 2 VALIDNS Version: YLC11.5 Output 3 VALIDNS Version: YLC11.5 Output 4 VALIDNS Version: YLC11.5 Logout

  1. Click Logout, on the far-right side of the menu bar, to log out of the web server and return to the Login page.

Info page

ATLONA Correcting Software RS-232 FED Config System Info Model Name: AT-DHD-CAT-4ED Software Version: V1.0.03 Output 1 VALENS Version: V1.31.31.5 Output 2 VALENS Version: V1.31.31.5 Output 3 VALENS Version: V1.31.31.5 Output 4 VALENS Version: V1.31.31.5

Model Name

The model SKU of this product.

Software Version

The version of firmware that the AT-UHD-CAT-4ED is running. Always make sure to check the AT-UHD-CAT-4ED product page, on the Atlona web site, for the latest version of firmware.

Output 1 VALENS Version - Output 4 VALENS Version

The version of firmware on the HDBaseT chip for each HDBaseT OUT port.

RS-232 page

ATLONA a Power company EVD EVD Codg Spam RS-232 RS-232 Parameter Setting Console Sound rate 175000 Data bit 8 Parity None Stop bit 1 New

RS-232 Parameter Setting

Click each of these drop-down boxes to select the desired baud rate, data bits, parity bit, and stop bit for the MASTER RS-232 / IR port.

Setting Description
Baud rate Sets the baud rate.The following options are available: 2400, 9600, 19200, 38400, 56000, 57600, 115200.
Data bit Sets the number of data bits used to represent each character of data.The following options are available: 7 or 8.
Parity Sets the parity bit, which can be included with each character to detect errors during the transmission of data.The following options are available: None, Odd, or Even.
Stop bit Sets the stop bit.Stop bits are sent at the end of each character, allowing the client to detect the end of a character stream. The following options are available: 1 or 2.

EDID page

ATLONA a Power company File 103-232 Edit Case Copy System Edit Edit lock: UNICOM Edit mode: INT INT Edit settings STD Edit copy: CMY

EDID lock

Click this toggle to switch the EDID lock mode. When set to the LOCK position,

EDID mode

Click this drop-down list to select the desired EDID mode.

EDID mode Description
INT Internal mode. Uses the default internal EDID
LEARN Learn mode. Allows the AT-UHD-CAT-4ED to read the downstream EDID. Once the EDID is learned, it will be used by the connected source device to determine what video and audio formats can be sent to the sink device. Refer to EDID Management (page 14) for more information.

INT EDID settings

Click this drop-down list to select the desired EDID.

EDID
STD ATL 1280x800 RGB 2CH
ATL 1080P 2CH ATL 1366x768 RGB 2CH
ATL 1080P Multi CH ATL 1080P DVI
ATL 1080P DD ATL 1280x800 RGB DVI
ATL 1080P 3D 2CH ATL 3840x2160@30 2CH
ATL 1080P 3D Multi CH ATL 3840x2160@30 Multi CH
ATL 1080P 3D DD ATL 3840x2160@60 2CH
ATL 720P 2CH ATL 3840x2160@60 Multi CH
ATL 720P DD

EDID copy

Click this button to copy the selected EDID to the HDMI IN port.

Config page

ATLONA a Passer company END 10-232 E3D Loading System Configuration Web & Telnet Login Settings Old Username: Old Password: New Username: New Password: Confirm New Password: All User Login Settings Username: Password: URL: OK Add Remove Add Remove

Old Username

This field cannot be changed. "root" is the administrator user.

Old Password

Enter the current password for the "root" username in this field. The default password is "Atlona".

New Username

This field cannot be changed.

Save

Click this button to save all changes.

New Password

Enter the new password for the "root" username in this field.

Confirm New Password

Verify the new password by retyping it in this field.

All User Login Settings

- Username

Displays the username.

- Password

Displays the password for the associated username.

- Edit

Click the Add button, in this column, to edit the username and password in the row.

• Del

Click the Remove button to delete the user in the row. This button will only be available if both a username and password have been created.

System page

ATLONA a Power company BIO HD-237 ESD Coding System Network IP Model: UNDP IP: 10.00 GB/GB Networks: 10.00 GB/GB Save Gateway: 10.00 GB/GB Telnet Port: Telnet Login Mode Telnet Timeout UG Broadcast File System Power ON Lock Power button mode Bit standby Reset to Default Factory Default Firmware Update Choose File: No file shown Update Values Update Choose File: No file shown Update CEC Power ON OFF

IP Mode

Click this toggle to set the IP mode of the AT-UHD-CAT-4ED. The default setting is DHCP. Available settings: STATIC IP, DHCP.

IP

Enter the IP address of the AT-UHD-CAT-4ED in this field. This field will only be available if IP Mode is set to STATIC IP. The default IP address is 192.168.1.254.

Netmask

Enter the subnet mask in this field. This field will only be available if IP Mode is set to STATIC IP.

Gateway

Enter the gateway (router) address in this field. This field will only be available if IP Mode is set to STATIC IP.

Telnet Port

Enter the Telnet listening port in this field.

Telnet Login Mode

Click this toggle to set the login mode to either ON or OFF. If this feature is set to ON, then the AT-UHD-CAT-4ED will prompt for both the username and password at the start of a Telnet session. Use the same credentials as the web server.

Telnet Timeout

Click this drop-down list to select the timeout interval, in seconds, before the Telnet connection is automatically closed after no activity. Range: 1 to 3600 (seconds).

Broadcast

By default, broadcast mode is set to ON. When set to ON, any system changes will be announced over TCP/IP connections to any device that has a TCP/IP connection to the AT-UHD-CAT-4ED. When set to OFF, only the device that is sending the commands will receive feedback from the commands or any system changes. Read queries, such as IPCFG and Type commands, are not announced and will only return information to the requester.

The Web Server

Power

Under normal operation conditions, this toggle is set to ON. Click this toggle to OFF, to place the AT-UHD-CAT-4ED in standby mode. The PWOFF and PWON commands can also be used to control the power state.

Lock

Click to lock or unlock the buttons on the front panel. Locking the front panel buttons is useful in preventing accidental button activation within rack environments.

Power button mode

Click this drop-down list to select the desired function of the power button. Refer to Power Button Modes (page 25) for more information.

Setting Description
DA standby Pressing the POWER button will toggle the AT-UHD-CAT-4ED between standby mode and normal operating mode.
CEC* When a sink device (display) is connected to the AT-UHD-CAT-4ED, pressing the POWER button will toggle the power state of the display using the CEC protocol.The power state of the AT-UHD-CAT-4ED is unaffected. Power-on and power-off commands are sent over both the HDBaseT OUT and HDMI OUT ports
BothPressing the POWER button will toggle the power state of both the AT-UHD-CAT-4ED and any sink devices that are connected to the AT-UHD-CAT-4ED, using the CEC protocol. Power-on and power-off commands are sent over both the HDBaseT OUT and HDMI OUT ports.

Reset to Default

Click the Factory Default button to set the AT-UHD-CAT-4ED to factory-default settings.

Firmware Update

Click the Choose File button to select the firmware file, when upgrading the firmware on the AT-UHD-CAT-4ED. Once the firmware file is selected, click the Update button. Refer to Updating the MCU Firmware (page 37) and Updating the Valens Firmware (page 39) for more information.

ON / OFF

Click these buttons to test CEC control between the AT-UHD-CAT-4ED and the connected sink device. Click the ON button to power-on the device and OFF to power-off the device. Refer to Power Button Modes (page 25) for more information.

*Consumer Electronics Control (CEC): Atlona has confirmed proper CEC functionality with several current models of Samsung, Panasonic, and Sony displays. However, it is not guaranteed that CEC will work with all displays. Many manufacturers do not support the CEC "off" command, and older displays use proprietary commands. Atlona only supports displays that use the CEC command structure defined in HDMI 1.2a. It is recommended that dealers request an evaluation product from Atlona, before designing a system using the CEC protocol. If this is not possible, then other control methods will need to be considered, in order to control displays using Atlona products.

Appendix

Updating the MCU Firmware

Updating the MCU firmware can be completed using either the USB interface or the web server. Atlona recommends using the web server for updating the MCU firmware. However, if a network connection is not available, the AT-UHD-CAT-4ED MCU firmware can be updated using a USB-A to USB mini-B cable.

Using the Web Server

Requirements:

  • AT-UHD-CAT-4ED
  • Firmware file
    • Computer running Microsoft Windows

  • Connect an Ethernet cable from the computer, containing the firmware, to the same network where the AT-UHD-CAT-4ED is connected.

  • Go to the System page (page 35) in the web server.

ATLONA a Resort company File 03-212 0000 Config Network IP Address: 12447 IP: 500,000.00 Network: 500,000.00 Gateway: 500,000.00 Socket Port: Socket Login Mode Socket Socket Timeout USB Broadcast System Power Lock Power button mode Go standby Reset to Default Fixing Button Formware Update Choose File No Be chosen Valero Update Choose File No Be chosen Save

  1. Click the Choose File button, under Firmware Update.
  2. Browse to the location of the firmware file, select it, and click the Open button.
  3. Click the Update button to begin the update process.
  4. The following message box will be displayed.

10.0.1.107 says: Are you Sure want to update Firmware? OK Cancel

  1. Click the OK button to begin the firmware update process. Click the Cancel button to cancel the process.
  2. After the firmware update process is complete, the Login screen will be displayed, indicating that the update process is complete.

Appendix

Using USB

Required items:

  • AT-UHD-CAT-4ED
    • Computer containing the firmware file.
    • USB-A to USB mini-B cable

  • Disconnect power from the AT-UHD-CAT-4ED.

  • Press and hold the POWER button while connecting power to the AT-UHD-CAT-4ED.

  • Release the POWER button. The POWER button will glow solid red, indicating that the AT-UHD-CAT-4ED is in update mode.

  • Connect the USB-A to USB mini-B cable between the PC and the firmware port on the AT-UHD-CAT-4ED.

  • The USB UPDATE folder will be displayed.

If this folder is not displayed, automatically, select the USB UPDATE drive from Windows Explorer.

Screenshot of a file explorer window showing USB updates with folder navigation and file list including Documents, Downloads, Music, Pictures, Videos, OS, Samsung_T3, and Public files.

  1. Delete all files from the USB UPDATE drive, if any are present.
  2. Drag-and-drop the firmware file to the drive. During the firmware update procedure, the POWER button will flash.
  3. After the file has been copied, disconnect the USB cable from both the computer and the AT-UHD-CAT-4ED.
  4. The firmware update process is complete.

Updating the Valens Firmware

Updating the Valens firmware can be completed using either the USB interface or the web server. Atlona recommends using the web server for updating the Valens firmware. However, if a network connection is not available, the AT-UHD-CAT-4ED Valens firmware can be updated using a USB-A to USB mini-B cable.

Using the Web Server

Requirements:

  • AT-UHD-CAT-4ED
  • Firmware file
    • Computer running Microsoft Windows

  • Connect an Ethernet cable from the computer, containing the firmware, to the same network where the AT-UHD-CAT-4ED is connected.

  • Go to the System page (page 35) in the web server.

ATLONA a Planet company File 03-212 EDS Config Network Network IP Model: IP: Network: Gateway: Talnet Port: Talnet Login Mode Talnet Timeout 120 Broadcast System Power Lock Power button mode OK standby Reset to Default Fixing Offset Firmware Update Choose File No Be chosen Valero Update Choose File No Be chosen Choose Choose File button

  1. Click the Choose File button, under Valens Update.
  2. Browse to the location of the firmware file, select it, and click the Open button.
  3. Click the Update button to begin the update process.
  4. The following message box will be displayed.

10.0.1.107 says: Are you Sure want to update Firmware? OK Cancel

  1. Click the OK button to begin the firmware update process. Click the Cancel button to cancel the process.
  2. After the firmware update process is complete, the Login screen will be displayed, indicating that the update process is complete.

Appendix

Using USB

Required items:

  • AT-UHD-CAT-4ED
    • Computer containing the firmware file.
    • USB-A to USB mini-B cable

  • Disconnect power from the AT-UHD-CAT-4ED.

  • Press and hold the POWER button while connecting power to the AT-UHD-CAT-4ED.

  • Release the POWER button. The POWER button will glow solid red, indicating that the AT-UHD-CAT-4ED is in update mode.

  • Connect the USB-A to USB mini-B cable between the PC and the firmware port on the AT-UHD-CAT-4ED.

  • The USB UPDATE folder will be displayed.

If this folder is not displayed, automatically, select the USB UPDATE drive from Windows Explorer.

Screenshot of a file explorer window showing a folder named 'USB UPDATE' with subfolders for Documents, Downloads, Music, Pictures, Videos, OS, Samsung_T3, and Public files.

  1. Delete all files from the USB UPDATE drive, if any are present.
  2. Drag-and-drop the firmware file to the drive. During the firmware update procedure, the POWER button will flash.
  3. After the file has been copied, disconnect the USB cable from both the computer and the AT-UHD-CAT-4ED.
  4. The firmware update process is complete.

Cable Termination

Atlona recommends EIA/TIA-568-B termination. Connector type and size is very important to ensure extenders work correctly. Always use the matching cable type with the correct RJ45 connector.

  • CAT5e cables should use only CAT5e RJ45 connectors
    • CAT6 cables should use only CAT6 connectors
    • CAT6a cables should use only CAT6a connectors
    • CAT7 cables should use only CAT7 connectors

Using the wrong size connectors may result in interference causing loss of signal.

Atlona AT-UHD-CAT-4ED - Cable Termination - 1

WARNING: EZ RJ45 connectors are not recommended with HDBaseT extenders. Doing so may result in interference with audio and video transmission.

EIA/TIA 568-B Termination 1. White - Orange 2. Orange 3. White - Green 4. Blue 5. White - Blue 6. Green 7. White - Brown 8. Brown

Refer to the tables below for recommended cabling when using Altona products with HDBaseT. The green bars indicate the signal quality when using each type of cable. Higher-quality signals are represented by more bars.

Core Cable Type CAT5e CAT6 CAT6a CAT7
Solid Unshielded Twisted Pair (UTP) N/A N/AShielded Twisted Pair (STP)■■■■
■■■■■■■■■■■■■■

Atlona AT-UHD-CAT-4ED - Cable Termination - 3

IMPORTANT: Stranded or patch cables are not recommended due to performance issues.

Default Settings

The following tables list the factory-default settings for the AT-UHD-CAT-4ED.

Feature Settings
RS-232 Baud rate115200
Data bit8
ParityNone
Stop bit1
EDID EDID lockUNLOCK
EDID modeINT
INT EDID settingsSTD
Config Username (default)root
Password (default)
System IP ModeDHCP
Static IP Address (default)
Netmask
Gateway
Telnet Port
Telnet Login Mode
Telnet Timeout
Broadcast
Power
Lock
Power button mode

Specifications

Video
Signal Input - HDMIOutput - HDMI / HDBaseT
Copy Protection 2.2
Pixel Clock 300 MHz
UHD/HD/SD 4096x2160 (DCI) @ 24/25/30 Hz720x576p @ 50 Hz
3840x2160 (UHD) @ 24/25/30 Hz720x576i @ 50 Hz
1920x1080p @ 23.97/24/25/29.97/30/50 /59.94/60 Hz720x480p @ 59.94/60 Hz
1920x1080i ^1) @ 50/59.94/60 Hz640x480p @ 60 Hz
1280x720p @ 30/50/60 Hz
VESA2560x1600 @ 60 Hz (RB)1366x768 @ 60 Hz
All resolutions are 60Hz2048x1536 @ 60 Hz1360x768 @ 60 Hz
2048x1200 @ 60 Hz1280x1024 @ 60 Hz
2048x1080 @ 60 Hz1280x800 @ 60 Hz
1920x1200 @ 60 Hz (RB)1280x768 @ 60 Hz
1920x1080 @ 60 Hz (RB)1280x720 @ 60 Hz
1680x1050 @ 60 Hz1152x870 @ 75 Hz
1600x1200 @ 60 Hz1024x768 @ 60 Hz
1600x900 @ 60 Hz848x480 @ 60 Hz
1440x900 @ 60 Hz800x600 @ 60 Hz
1400x1050 @ 60 Hz640x480 @ 60 Hz
Color Space YUV, RGB
Chroma Subsampling 4:4:4, 4:2:2, 4:2:0
Color Depth 8-bit, 10-bit, 12-bit
Audio
HDMI / HDBaseTPass-Through FormatsPCM 2.0LPCM 5.1LPCM 7.1Dolby® DigitalDolby Digital PlusTMDolby TrueHDDolby Atmos®DTS® Digital SurroundTM DTS-HD Master AudioTM DTS:X®
Bit Depth Up to 24 bits
Sample Rate 32 kHz, 44.1 kHz,48 kHz, 88.2 kHz, 96 kHz, 176.4 kHz, 192 kHz
Resolution / Distance 4K/UHD - Feet / Meters 1080p - Feet / Meters
HDMI IN/OUT 15 5 30 10
CAT5e23070 330100
CAT6/6a/7330100330100
Control
RS-232Device control and configurationSupported baud rates: 2400, 4800, 9600, 19200, 38400, 57600, 115200
IPProtocols: HTTP, Telnet, mDNSModes: DHCP, Static - selectable through webGUI
IRPass-through from control system to sink devicePass-through from viewing location to source
CEC Support Yes

Appendix

Buttons and Indicators
Buttons:POWER, EDID2 x momentary, tact-type
Indicators:HDMI IN/OUT,HDBaseT (1 - 4), LOCK,INT, LEARN9 x LED, blue
Connectors
HDMI IN 1 x Type A, 19-pin female
HDMI OUT 1 x Type A, 19-pin female
HDBaseT OUT 4 x RJ45
LAN 1 x RJ45
RS-232 / IR 5 x 5-pin captive screw
FW 1 x Mini USB
DC 48V 1 x 3-pin DIN
Environmental Fahrenheit Celsius
Operating Temperature +32 to +122 0 to +50
Storage Temperature -4 to +140 -20 to +60
Operating Humidity (RH) 20% to 90%, non-condensing
Power
Consumption60 W
Idle Consumption13.5 W
External Power Supply100 - 240 V AC, 50/60 HzOutput: 48 V / 2.08 A DC
Dimensions (H x W x D)InchesMillimeters
Unit1.73 x 8.75 x 10.2844 x 222 x 261
Power Supply (AT-PS-48208-D3)1.3 x 2.24 x 5.3533 x 57 x 136
WeightPoundsKilograms
Device3.701.66
Certification
DeviceCE, RoHS, FCC
Power SupplyCE, FCC, Level VI, RoHS, cULus, RCM, CCC
Compliance
NDAA-899Yes

(1) 4096x2160 @ 50/60 Hz and 3840x2160 @ 50/60 Hz only supports 4:2:0 8-bit chroma subsampling.

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Atlona

Model : AT-UHD-CAT-4ED

Category : Distribution Amplifier