Product Type 3-Series Control Card
Brand Crestron
Model C3RY-8
Number of Relays 8
Relay Type Normally Open, Isolated
Relay Rating 1 A, 30 V AC/DC
Connectors 2 terminal blocks (8 relays)
Compatible Control Systems PRO3, AV3 (with CAGE3), CEN-CI3-1, CEN-CI3-3
Incompatible Systems 2-Series (PRO2, AV2, PAC2)
Mounting Slot installation in expansion cage
Required Tools Phillips screwdriver, grounding strap
Power Source Powered by control system
ESD Sensitivity Yes (electrostatic-sensitive devices)
Safety Compliance UL Listed, FCC Part 15 Class B, ICES-3(B)
Environmental Compliance CE marked
Warranty See www.crestron.com/warranty
Dimensions (Approx.) 4.3 x 3.2 x 1.2 in (109 x 81 x 30 mm)
Weight (Approx.) 0.2 lb (90 g)
Operating Temperature 32° to 104°F (0° to 40°C)

Frequently Asked Questions - C3RY-8 Crestron

What is the Crestron C3RY-8 control card used for?
The C3RY-8 is a 3-Series control card that provides 8 normally open isolated relays for switching low-voltage loads up to 1 A at 30 V AC/DC. It is used for controlling lights, shades, screens, and other devices in a Crestron automation system.
Which Crestron control systems support the C3RY-8?
The C3RY-8 is compatible with 3-Series Control Systems such as PRO3 and AV3 (with CAGE3 expansion cage), and 3-Series Card Interfaces CEN-CI3-1 and CEN-CI3-3. It is not compatible with 2-Series systems (PRO2, AV2, PAC2).
How do I install the C3RY-8 card?
Installation requires a Phillips screwdriver and a grounding strap. Disconnect power, remove the blank faceplate, align the card in an open slot, firmly press to seat the connector, tighten thumb screws, and restore power. Ensure ESD precautions are followed.
What is the relay rating of the C3RY-8?
Each relay on the C3RY-8 is rated for 1 A at 30 V AC/DC (resistive load). Relays are normally open and isolated, suitable for low-voltage switching applications.
Can I use the C3RY-8 in a 2-Series system?
No, the C3RY-8 is not compatible with any 2-Series control system (PRO2, AV2, PAC2), even if installed in a CAGE3 expansion cage. It requires a 3-Series system.
Does the C3RY-8 require external power?
The C3RY-8 is powered directly from the control system via the expansion slot. No external power supply is needed.
How many relays does the C3RY-8 have?
The C3RY-8 provides 8 relays on two terminal blocks. Each relay is independently controllable and normally open.
What should I do if the card does not function?
First, verify power to the control system. Ensure the card is properly seated in the slot. Check grounding and connections. If problems persist, contact Crestron support.
What are the dimensions and weight of the C3RY-8?
Approximate dimensions: 4.3 x 3.2 x 1.2 inches (109 x 81 x 30 mm). Weight: approximately 0.2 lb (90 g).
Is the C3RY-8 FCC compliant?
Yes, the C3RY-8 complies with FCC Part 15 Class B limits for residential use. It also meets Industry Canada ICES-3(B) requirements and is CE marked.

User questions about C3RY-8 Crestron

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Carte électronique de contrôle in PDF format for free! Find your manual C3RY-8 - Crestron and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. C3RY-8 by Crestron.

USER MANUAL C3RY-8 Crestron

Crestron ^® 3-Series ^® control cards are designed to install into a control card expansion slot of a 3-Series Control System ^® device (PRO3 or AV3). The cards can also be installed into a 3-Series Card Interface device (CEN-CI3-1 or CEN-CI3-3).

NOTE: The AV3 requires the CAGE3 Control Card Expansion Cage accessory to enable use of 3-Series control cards.

NOTE: 3-Series control cards are not compatible with the 2-Series PRO2, AV2, or PAC2 models. Even when installed in the CAGE3 Control Card Expansion Cage, the cards are not compatible with any 2-Series control system.

Additional Resources

Visit the product page on the Crestron website (www.crestron.com) for additional information and the latest firmware updates. Use a QR reader application on your mobile device to scan the appropriate QR image.

QR code image containing encoded data, no visible human-readable text

QR code image containing encoded data, no visible human-readable text

C3IO-16C3COM-3

QR code image containing encoded data, no visible human-readable text

C3IR-8 C3RY-8

QR code image containing encoded data, no visible human-readable text

QR code image containing encoded data, no visible human-readable text

C3RY-16

Installation

Items required to install the 3-Series control cards are already attached to the unit. The only tools required are a Phillips screwdriver and a grounding strap. To install the control card, follow the procedure below.

CAUTION: 3-Series control cards contain electrostatic-sensitive devices (ESD); observe precautions for handling ESDs to avoid damaging the card.

NOTE: If the card is being installed into an AV3, ensure that the CAGE3 Control Card Expansion Cage accessory is installed before completing this procedure.

  1. Disconnect power from the control system.
  2. Use the Phillips screwdriver to remove two screws and the blank faceplate from the control system.
  3. Align the 3-Series control card guides in the open slot and slide the control card into position.
  4. Firmly press on both ends of the 3-Series control card faceplate to seat the control card into the control system connector.
  5. Tighten the thumb screws to secure the 3-Series control card to the control system.
  6. Reapply power to the control system.

C3COM-3 Wiring Connections

The C3COM-3 provides three bidirectional RS-232/422/485 ports (COM 1–3). Refer to the following table when making connections to the C3COM-3.

C3COM-3 Pin Out

PIN RS-232 RS-422 RS-485
GGND GND GND1
TXTX TX- TX-/RX-
RXRX RX+ (Not Used)
RTSRTS TX+ TX+/RX+
CTSCTS RX- (Not Used)

^1 A ground terminal connection is recommended but not required. Ground potential difference must be under +/-4 v.

C3RY-8/C3RY-16 Wiring Schematics

The C3RY-8 and C3RY-16 provide two terminal blocks that contain eight normally open, isolated relays (rated 1 amp, 30 volts ac/dc). Refer to the following diagrams when making connections to the C3RY-8 or C3RY-16.

C3RY-8 Wiring Schematic
1 2 3 4 5 6 7 8

C3RY-16 Wiring Schematic
A 1 2 3 4 5 6 7 8 C

B 1 2 3 4 5 6 7 8 C

Troubleshooting

The following table provides corrective actions for possible issues that may arise. If further assistance is required, please contact a Crestron customer service representative.

3-Series Control Card Troubleshooting

TROUBLE POSSIBLE CAUSE(S)CORRECTIVE ACTION
The control card does not function.The control system is not receiving power.Verify the power to the control system.
The control card is not properly seated in the slot.Verify that the control card is properly inserted into the control system slot per the procedure in this guide.
There is a loss of functionality due to electrostatic discharge.The control system is improperly grounded.Check that all connections to the control system have been properly made.

As of the date of manufacture, the device has been tested and found to comply with specifications for CE marking.

Crestron C3RY-8 - Troubleshooting - 1

These products are Listed to applicable UL ^® Standards and requirements by Underwriters Laboratories Inc.

Federal Communications Commission (FCC) Compliance Statement

CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Industry Canada (IC) Compliance Statement

CAN ICES-3(B)/NMB-3(B)

Product warranty can be found at www.crestron.com/warranty.

The specific patents that cover Crestron products are listed at patents.crestron.com.

Certain Crestron products contain open source software. For specific information, please visit www.crestron.com/opensource.

Crestron, the Crestron logo, 3-Series, and 3-Series Control System are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.

This document was written by the Technical Publications department at Crestron.

©2017 Crestron Electronics, Inc.

Crestron Electronics, Inc. Installation Guide

15 Volvo Drive DOC. 7944B

Rockleigh, NJ 07647 (2047636)

Tel: 888.CRESTRON 02.17

Fax: 201.767.7576 Specifications subject to

www.crestron.com change without notice.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Crestron

Model : C3RY-8

Category : Carte électronique de contrôle