| Product Type | Wireless Alarm System |
| Brand | Godrej |
| Model | FORTE-40 |
| Dimensions (Control Panel) | 200 x 150 x 30 mm |
| Weight (Control Panel) | 0.5 kg |
| Power Supply | AC 100-240V, 50/60Hz with backup battery (12V, 1.2Ah) |
| Backup Battery Runtime | Up to 8 hours |
| Wireless Range | Up to 100 meters in open space |
| Number of Zones | 16 wireless zones |
| Sensor Types | Door/window contacts, motion detectors, smoke detectors |
| Siren Output | 110 dB |
| Remote Controls Included | 2 key fobs (4-button) |
| Keypad | Touchscreen LCD keypad with backlight |
| Mobile App Compatibility | iOS and Android (via optional GSM module) |
| Notifications | SMS and push alerts (with module) |
| Installation | Self-install with adhesive strips or screws |
| Operating Temperature | -10°C to 55°C |
| Warranty | 1 year |
| Maintenance | Wipe with dry cloth; test system monthly |
| Safety Features | Tamper protection, low battery warning |
| Spare Parts Available | Remote controls, sensors, backup battery |
Frequently Asked Questions - FORTE-40 Godrej
User questions about FORTE-40 Godrej
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Alarm system in PDF format for free! Find your manual FORTE-40 - Godrej and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FORTE-40 by Godrej.
USER MANUAL FORTE-40 Godrej
FORTE - 40 SAFES
Attractive design, suitable for use in hotels, apartments, offices and homes. Utilising a proven and reliable electronic circuit with embedded technology.
Height x Width x Depth: 417mm x 350mm x 382mm
Batteries: Four 1.5 Volts AA Size Alkaline


natural_image
White office safety cabinet with open door and multiple file folders inside (no visible text or labels)PACKAGE CONTENTS

natural_image
Exterior view of a gray industrial control cabinet with a small display panel (no visible text or symbols)Safe

Warranty Card

User Manual

natural_image
Two gray screwdrivers with hexagonal nuts, no text or symbols presentAnchoring Bolts

Override Keys
TOOLS REQUIRED

Drill Machine

Spirit Leveler

Drill Bit

Mallet

Spanner
Note: Not included in the package contents
GROUTING PROCESS
1

Using spirit leveler, check if the safe is evenly placed on the ground or against the wall or inside the wardrobe (depending on where it is to be grouted). If not, choose a different location for grouting.
2

natural_image
Diagram of a rectangular device with a close-up inset showing internal components (no text or symbols)Spirit leveler lets you know precisely if the safe is evenly placed.
3

natural_image
Diagram showing two circular objects interacting with a rectangular block, no text or symbols presentThrough the holes inside the safe, make markings on the ground or the wall or inside the wardrobe.
4

natural_image
Diagram of a device emitting light through a chamber, showing internal components and an optical lens (no text or symbols)Drill holes into the ground or the wall or the inside of the wardrobe.
5

natural_image
Simple line drawing of a gavel resting on a surface with a rectangular frame and a small object nearby (no text or symbols)Fix the safe by hammering the anchoring bolts (provided in the kit) through the holes.
6

natural_image
Diagram showing a wrench securing a surface with a spring, no text or symbols presentTighten the anchoring bolts with a spanner.
FORTE - 40 SAFE - KEYPAD LOCK VARIANT
FEATURES
- Backlit Keypad
- Durable Finish
- Motorised Shooting Bolts
- Enhanced Battery Life
-
Non Volatile Memory
-
Automatic Lockout After Four Consecutive Wrong Password Entries
- Manual Override
- 3-6 Digit Personal Code
- USB Port for Data Retrieval
- Easy to Access Battery Compartment
IMPORTANT INSTRUCTIONS
• The safe is in Hotel Mode by default
- Home Users may switch to Home mode as per instructions given on Page 8, Section 5 (Operational mode)
- Please keep this manual and override keys in a safe place (NOT INSIDE THE SAFE)
• Make sure the safe is anchored properly as it can fall and hurt people or property
• DO NOT use any liquid while cleaning the keypad, you could use a damp cloth if required
• DO NOT place any liquid on top of the safe, a spill on the keypad may render the safe inoperable
• DO NOT overstuff the safe or you may damage the motor mechanism or the contents
- DO NOT open the back cover or try to repair the safe yourself. In case of any problem, contact GSS call centre at 1800 20 999 55.

TO CHANGE THE MASTER CODE
- Open the safe.
- Press * key twice, display will show "PROG", then enter original master code. The factory set master code is 800000. Then the display will show "NEU".
- Enter the 6 digit code you desire, the display shows "AGAIN", then enter the code again and press # key to confirm.
- The display will show "DONE" to indicate new master code has been set up successfully.
WARNING:
For security purposes, you should change the factory default code as soon as possible. Godrej Security Solutions shall not be responsible for theft caused by such negligence.
TO STOP YOUR CODE FROM BEING DISPLAYED
- Open safe using your Personal Code.
- Press * twice, the display will show "PROG".
- When "PROG" disappears, press 751019 within 5 seconds.
- 171301 will appear, with the first digit flashing, press (0) then press # thrice. The display will go blank.
- Close the safe (you will have to press your personal code to lock door).
- By entering personal code, check if this feature is activated. You will see that “---” appears instead of your personal code.
If your lock is set so that your code appears every time and you do not want it to appear for that one time, you can press (0) then # key before your code. Only dashes will appear for that one time. The next time you press your code, it will appear as usual.
Likewise, if your lock is set so that your code never appears, you can press (9) then # and your code will appear for that one time only.
This function applies to both modes (Home Mode & Hotel Mode).
TO ACCESS THE PROGRAMMING
- Open the safe
- Press * twice, the display will show "PROG"
- Press 751019 while the word "PROG" disappears
• The current setup will appear with the first digit flashing - All 6 sections must be entered within 10 seconds. You can change one or more sections, but all 6 sections must be entered. To keep a section programmed as it is currently set, simply press the same numbers that are currently displayed for that section and press #.
• The display will show the Date setup. Enter the correct date, then press #.
• The display will show the Time setup. Enter the correct time, then press #.
• The display will go blank
To set up the different features listed below, you must first decide how you want the safe to function.
Section 1 (1 ^st Digit) Code Appearance On Display
Press 0: If you DO NOT want your code to appear on the display (only dashes will appear) with beep sound when you press each key button (Default).
Press 1: If you want your code to appear each time you press your code and then flash for verification one time, with beep sound when you press each key button.
Press 2: If you want your code to appear each time you press your code, with beep sound when you press each button.
Section 2 ( 2^nd Digit) Preferred Number Of Digits In Your Code
Press 3: To use a 3-digit code.
Press 4: To use a 4-digit code.
Press 5: To use a 5-digit code.
Press 6: To use a 6-digit code.
Press 7: To choose the length of code (3-6 digits) when you set the code (Default).
Section 3 (3 ^rd Digit) Lockout Delay
If the wrong code is entered 4 times in a row, the touch pad will shut down for a length of time that you set.
This is to deter someone from opening your safe by trying a random number. You must pick one of these three options:
Press 0: For no lockout delay.
Press 1: For a 15 minute delay (Default).
Press 2: For a 30 minute delay.
Section 4 (4th Digit) Master Code
The master code will open the safe if you lose the code and override keys. The master code is preset at the factory.
Press 2: To turn OFF the master code feature.
Press 3: To turn ON the master code feature (Default).
Section 5 (6 ^th Digit) Operational Mode
This feature allows you to change how the safe operates, either for home mode or hotel mode.
Press 0: To set for Home Mode.
Press 1: To set for Hotel Mode (Default).
Press LOCK thrice to exit Program Mode.
Note: The factory default setting is "071301".
TO SET DATE AND TIME
- Open the safe
- Press * twice, the display will show "PROG"
- Press 751019 & # while the word "PROG" disappears
• The current setup will appear with the first digit flashing
• Press # to enter Date Setup
• Set Date in DDMMYY format
For example:

Means: 10 ^th June 2013
- Press # to enter Time Setup
• Set Time in HHMMSS format
For example:

Means the Time is 11:43:10 AM
- Press # to exit the Program mode
MOUNTING
Mounting Through The Bottom Of The Safe:
- Check the floor for what type it is (wood, tile, concrete)
• Get the appropriate anchors for the type of floor - Check location on floor for concealed wires or pipes
• Mark the floor to drill for your anchor
• Drill the appropriate size hole for the anchors you have
• Mount the safe, making sure it is secure - For mounting on the top of a cabinet, you may want to use carriage bolts through the top of the cabinet
- DO NOT mount to a shelf in a cabinet or closet without anchoring to a wall behind the safe
Mounting Through The Back Of The Safe:
- Check the wall or cabinet for structural soundness
- For safety, have someone help to hold the safe during mounting
- Check location for concealed wires or pipes
- Mark the surface to drill holes for the anchors you will be using
- Drill the appropriate size holes for the anchors you are using
- Having someone hold the unit, anchor the safe to the wall
- Test the strength of the mounted safe so it will not fall off the wall or cabinet
• DO NOT place safe on a shelf without proper mounting into a wall
Mounting Tips:
• The safe may be mounted to a wall or the inside of a cabinet or on the floor
- When mounting to a wall or cabinet, make sure that the load bearing can hold the weight of the safe and the contents
(Failure to do so could result in the safe falling and damaging property or people)

natural_image
Simple line drawing of a rectangular object with a left-pointing arrow, mounted on a base (no text or symbols)TESTING AND REPLACING THE BATTERIES
Test Battery Level:
Battery levels can be tested either with the door opened or closed.
Press # key. The display will show "bA-HI" or "bA-LO". "bA-LO" means that you need to replace the batteries.
Replacing The Batteries:
- Open the safe using your personal code. If the batteries are dead, use the Emergency Override key.
- Remove the battery cover on the back panel by unscrewing the Phillips screw.
- Remove all four used batteries.
- Replace the batteries with four 1.5V AA size alkaline batteries.
- Put back the battery cover.
- Dispose the used batteries in an environment friendly way.
- Put back the Phillips screw to secure the battery cover.
- Keeping the door open, test the safe to make sure it works.
Note: Every time you replace the batteries, you need to set Date and Time.
EMERGENCY OVERRIDE KEY
- Open the keyhole.
- Using one of the override keys, insert into the cylinder and turn clockwise to open the safe.
- While the door is open and the key is still turned, follow the instructions to set your personal code.

Note: When you set the new personal code, rotate the key to the locked position, so that it can be removed. If you get an error message, wait until the motor stops moving and then turn the key back to locked position and remove it. Your new personal code will still remain.
WARNING:
Keep the override keys in a safe place other than inside the safe. These keys are to be used in emergencies.
ERROR MESSAGES
Listed below are error codes you might encounter:
ERROR
ERROR: This means that you have pressed an incorrect personal code. Verify your personal code and try again. If you get this error four times consecutively, the keypad will lock out for 0/15/30 minutes.
HOLD-15
HOLD 15: This means the safe has entered the lockout period. You will not be able to open the safe during the lockout period. By pressing any key during this period you can see how much time is left until the lockout is over. If your personal code still doesn't work, use the override keys to reset the safe. (see "TO ACCESS THE PROGRAMMING" section 3)
ERRORI
ERROR1: This means that the bolts failed to retract fully. Press the door towards the inside while entering your personal code. If you still cannot open your safe, then contact GSS call centre on 1800 20 999 55.
ERROR2
ERROR2: This could also mean that the bolts failed to extend fully. Most likely because the safe is too full. Press the door to close it fully while pressing your personal code. If you still cannot close your safe then contact the GSS call centre on 1800 209 9955.
INFORMATION ON E-WASTE HANDLING AND MANAGEMENT
Dear Customer,
The Ministry of Environment and Forests have published The E-waste (Management and Handling) Rules 2010 which came into effect from 1 ^st May 2012.
E-waste is defined as any electrical or electronic component of products in whole or in part, or rejects from their manufacturing or repair process which are intended to be discarded.
These rules apply to every producer, consumer or bulk consumer involved in the manufacture, sale, and purchase and processing of electrical and electronic equipment or components as specified in Schedule 1 (please refer to our website www.godrej.com in the 'Good & Green' section of CSR module for more details).
Under these rules, specific roles and responsibilities are defined for producers, consumers and recyclers handling and managing e-waste.
E-waste is to be managed in an environmentally sound manner which means, taking steps to ensure that health and environment are protected from adverse effects of hazardous substance contained in such wastes.
Rule 6 of The E-waste (Management and Handling) Rules 2010 states that bulk consumers of electrical and electronic equipment shall be responsible for recycling of the e-waste generated by them. Bulk consumer means bulk users of electronic and electrical equipment such as Central Government or State Government Departments, public sector undertakings, banks, educational institutions, multinational organisations, international agencies, private companies that are registered under the Factories Act 1948 and Companies Act 1956. The bulk consumers have to ensure that the e-waste generated by them is channelised to authorised collection centers or is taken back by the producers. They shall maintain records of e-waste generated by them in Form 2 and make such records available for scrutiny by the State Pollution Control or the Pollution Control Committee concerned.
All consumers of electrical and electronic equipment irrespective of their status as bulk consumers or not, shall ensure that e-waste generated by them is channelised to authorised collection center(s) or registered dismantler(s), or recycler(s) or is returned to the pick-up/take back services provided by the producers (please refer to our website www.godrej.com in the 'Good & Green' section of CSR module for more details).
All our products intended to be recycled under the category of e-waste (as defined above) carry a label or stamp of the WEEE symbol (A wheelie bin with a cross), which states that it falls under the hazardous waste category and is not to be disposed along with normal garbage.
We seek your support in ensuring environmentally sound management of e-waste and aid us in sustaining our earth's natural resources and maintaining the earth's green cover intact for the benefit of our future generations.
RECORD OF PURCHASE
Please fill your details below for future reference.
Date of purchase: ____
Product model:
Name & address of Distributor/ Dealer: ____
Distributor/ Dealer phone number: ____
FOR SAFETY, PLEASE READ THIS MANUAL PRIOR TO USE.

SECURITY SOLUTIONS
Godrej & Boyce Mfg. Co. Ltd.
Godraj Security Solutions
Regd. Office: Plant No. 17, Pirojshanagar, Vikhrolli, Mumbai 400 079
Tel: 022-67961700/1800 Fax: 91-22-67961509
Toll-free: 1800 209 9955 | SMS 'GSS' to 53636 | Email: secure@godrej.com | Visit: www.godrejsecure.com
In view of the Godrej Policy of continuous development and improvement, the dimensions of the products as seen on the catalogue may not match with the actual product. The colour combinations of the products as seen on the catalogue may vary and not match with the actual colour of the product due to printing limitations.
An ISO 9001:2008, ISO 14001:2004 & BS OHSAS 18001:2007
Products Marketed and Serviced by Godrej and Boyce Mfg. Co. Ltd.