Uni-T UT216B - Measurement

UT216B - Measurement Uni-T - Free user manual and instructions

Find the device manual for free UT216B Uni-T in PDF.

📄 1 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Uni-T UT216B - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeClamp Meter
BrandUni-T
ModelUT216B
AC Current Range0.1A to 600A
DC Current Range0.1A to 600A
AC Voltage Range0.1V to 600V
DC Voltage Range0.1V to 600V
Resistance Range0.1Ω to 60MΩ
Capacitance Range0.1nF to 60mF
Frequency Range10Hz to 1MHz
Temperature Range-40°C to 1000°C (with K-type thermocouple)
Display Count6000 counts
True RMSYes
Auto RangeYes
Data HoldYes
BacklightYes
Non-Contact Voltage (NCV)Yes
Safety RatingCAT II 600V, CAT III 300V
Power Supply2 x AAA batteries
Dimensions215 x 63 x 36 mm
WeightApprox. 200 g (including batteries)
Accessories IncludedTest leads, K-type thermocouple, carrying case, manual

Frequently Asked Questions - UT216B Uni-T

How do I measure AC current with the UT216B?
Set the rotary switch to the AC current range (400A or 600A). Open the clamp jaws and clamp around a single conductor. Read the value on the display. Ensure the conductor is centered in the jaws for accuracy.
How do I replace the batteries?
Turn off the meter and remove the test leads. Use a screwdriver to open the battery cover on the back. Replace the two AAA batteries, observing polarity. Close the cover securely.
What does the NCV function do?
Non-Contact Voltage detection. Place the clamp near a wire or outlet. The meter will beep and flash if voltage is detected. It helps identify live wires without direct contact.
Can the UT216B measure DC current?
Yes, select the DC current range (400A or 600A). Clamp around the conductor. Note that DC current measurement requires zero adjustment before clamping (press ZERO button).
What is the maximum voltage this meter can measure?
The UT216B can measure up to 600V AC or DC. Do not exceed this limit to avoid damage or injury.
How accurate is the UT216B?
Accuracy varies by range. For example, AC current is ±(2.5%+5 counts), DC current ±(2.5%+5 counts), AC/DC voltage ±(1.2%+5 counts). Refer to manual for full specs.
Does the meter have auto-ranging?
Yes, the UT216B features auto-ranging for most measurements. You can also manually select range using the RANGE button.
How do I measure temperature?
Turn the dial to the TEMP setting. Insert the K-type thermocouple into the input jacks (COM and VΩ). Touch the probe tip to the object. The display shows temperature in °C or °F.
What safety precautions should I take?
Always use the meter within its rated category (CAT II 600V, CAT III 300V). Inspect test leads for damage. Do not measure voltage above 600V. Remove test leads before changing batteries. Use the meter in dry conditions.
How do I clean and maintain the UT216B?
Clean the exterior with a damp cloth and mild detergent. Do not use solvents. Store in a dry place. Remove batteries if not used for extended periods. Calibration should be done annually.

User questions about UT216B Uni-T

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measurement in PDF format for free! Find your manual UT216B - Uni-T and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UT216B by Uni-T.

USER MANUAL UT216B Uni-T

UT216 series digital clamp meters are designed for measuring high frequency currents (up to 400Hz) in railways and aerospace, server rooms, IT systems, etc. Its double injection design gives users a more comfortable grip and enhanced durability.

UT216's 6000 count display also provides precise readings for users.

Range UT216D UT216A UT216B UT216C
AC current (A)600A±(2.5%+5)±(2.5%+5)±(2.5%+5)±(2.5%+5)
AC current frequency response50/60Hz40~400Hz 40~400Hz 40~400Hz
DC current (A)600A±(2.5%+5)±(2.5%+5)
AC voltage (V)750V±(1.2%+5)±(1.2%+5)±(1.2%+5)±(1.2%+5)
AC voltage frequency response40~400Hz40~400Hz 40~400Hz 40~400Hz
DC voltage (V)1000V±(0.8%+3)±(0.8%+3)±(0.8%+3)±(0.8%+3)
Resistance (Ω)60MΩ±(1%+2)±(1%+2)±(1%+2)±(1%+2)
Capacitance (F)60mF±(4%+5)±(4%+5)±(4%+5)±(4%+20)
Frequency (Hz)10Hz~1MHz±(0.1%+4)±(0.1%+4)±(0.1%+4)
Temperature (°C)-40°C~1000°C±(3%+5)±(3%+5)
Temperature (°F)-40°F~1832°F±(3%+5)±(3%+5)
Features
Display count60006000 6000 6000
Auto range
Jaw opening30mm 30mm 30mm 30mm
True RMS
DiodeAround 3.0V
VFC
NCV
Data hold
Relative mode
MAX/MIN
LCD backlight
Inrush current
OLED display
Analog bar graph61 21
Flashlight
Auto power off
Continuity buzzer
Low battery indication≤3.6V
Input protection
Input impedance for DCV≥10MΩ
Power1.5V battery (R03) x8
Display38mm x 24mm
Product colorRed and grey
Product net weightUT216A: 280g; UT216B/C/D: 231.7g
Product size220mm x 75mm x 40mm
Standard accessoriesBatteries, test leads, point contact temperature probe (UT216C/UT216D)
Standard individual packingGift box, carrying bag, English manual
Standard quantity per carton20pcs
Standard carton measurement485mm x 335mm x 205mm
Standard carton gross weightUT216A: 9.4kg; UT216B: 9kg; UT216C: 10kg; UT216D: 9.6kg