Uni-T UT697 - Measurement

UT697 - Measurement Uni-T - Free user manual and instructions

Find the device manual for free UT697 Uni-T in PDF.

📄 2 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Uni-T UT697 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Digital Multimeter
Display 6000 counts LCD with backlight
DC Voltage Range 600 mV to 1000 V
AC Voltage Range 600 mV to 750 V
DC Current Range 600 µA to 10 A
AC Current Range 600 µA to 10 A
Resistance Range 600 Ω to 60 MΩ
Capacitance Range 10 nF to 10 mF
Frequency Range 10 Hz to 10 MHz
Temperature Measurement -20°C to 1000°C (with K-type thermocouple)
Dimensions 190 x 90 x 50 mm
Weight 380 g (including battery)
Power Supply 9V battery (6F22)
Safety Rating CAT III 1000V, CAT IV 600V
Accessories Included Test leads, K-type thermocouple, 9V battery, user manual
Maintenance Clean with a dry cloth; do not use solvents
Spare Parts Replaceable test leads, battery
Warranty 1 year manufacturer warranty

Frequently Asked Questions - UT697 Uni-T

How do I measure DC voltage with the UT697?
Turn the dial to the DC voltage position (V---). Connect the black test lead to COM and red to VΩ. Touch probes to the circuit and read the display.
What is the maximum voltage the UT697 can measure?
The UT697 can measure up to 1000V DC and 750V AC RMS. Do not exceed these limits to avoid damage or injury.
How do I replace the battery?
Turn off the meter and remove the test leads. Remove the battery compartment screw, slide off the cover, replace the 9V battery, and secure the cover.
Does the UT697 have an auto power-off feature?
Yes, the UT697 automatically powers off after approximately 15 minutes of inactivity to conserve battery life.
Can I measure temperature with the UT697?
Yes, the UT697 measures temperature using a K-type thermocouple (included). Set the dial to °C/°F, connect the thermocouple, and read the temperature.
What does 'OL' mean on the display?
'OL' stands for Overload. It indicates that the measured value exceeds the selected range. Switch to a higher range if available.
How do I test continuity?
Turn the dial to the continuity/beep position (usually marked with a diode symbol). Connect the test leads to the circuit. The meter will beep if the resistance is below about 50Ω.
Is the UT697 safe for use in high-energy circuits?
The UT697 is rated CAT III 1000V and CAT IV 600V, meaning it is safe for use in distribution-level installations and outdoor feeders. Use appropriate PPE and follow safety guidelines.
What is the accuracy of the UT697?
Accuracy varies by function and range. Typical DC voltage accuracy is ±(0.5% + 5 digits). Refer to the manual for detailed specifications.
Can I measure AC current without breaking the circuit?
No, the UT697 is a non-clamp meter; you must break the circuit and connect the meter in series to measure current. For non-invasive AC current measurement, consider a clamp meter.

User questions about UT697 Uni-T

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measurement in PDF format for free! Find your manual UT697 - Uni-T and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UT697 by Uni-T.

USER MANUAL UT697 Uni-T

Series Optical Products User Manual

Preface

Thank you for purchasing the new UT690 series optical products. In order to use these products safely and correctly, please read this manual thoroughly, especially the Safety Warning part.

After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.

Limited warranty and liability

Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination or improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.

Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by using this device. As some countries or regions do not allow limitations on implied warranties and incidental or subsequent damages, the above limitation of liability may not apply to you.

1. Safety Warning

This manual contains the necessary operation instructions and equipment maintenance methods. Please read each part of it carefully before using the equipment.

If the manual is not read or the operating instructions are not understood, the operation may cause inaccurate test results or damage the equipment, or even endanger personal safety.

Mini-USB charging port is reserved for charging lithium battery, which is not applicable currently. This version of the manual is subject to change without prior notice.

Symbol Description:

Double insulatedCEConforms to EU standards
WarningPlease read the instructions before use.
Do not discard the battery as unsorted municipal waste. Please place it in a fixed battery recycling station for disposal.

2. Introduction

UT690 series optical products include optical power meters, light sources, optical multimeters, etc. They are mainly used for optical signal power measurement, optical fiber line loss test, optical device insertion loss test, optical fiber fault detection, optical fiber breakpoint location, end-to-end optical fiber identification and so on. These products are designed to meet the ergonomic requirements and advanced cold molding technology is adopted to make them beautiful and durable. Provided with IP65 dust and water prevention function, UT690 series can be widely applied to optical cable construction and maintenance, optical fiber communication, optical fiber sensing, optical CATV and other fields.

2.1 Models

ModelsUT692D/UT692GUT693DUT696UT697
NameOPTICAL POWER METEROPTICAL MULTIMETEROPTICAL LIGHT SOURCEOPTICAL MULTIMETER
Main functionPower meterPower meter + visual fault locatorLight sourcePower meter + light source

2.2 Features

• IP65 dust and water prevention

• Auto power off

• Low battery indication

- Backlight on/off

- Flashlight function (UT692D, UT692G, UT696)

• Optical power meter

o User self-calibration function

o Simultaneous display of linear mW and non-linear dBm

o Wavelength memory function

a Reference power memory function

o Eight calibrated wavelengths (850, 980, 1300, 1310, 1490, 1550, 1625 and 1650 nm)

• Visual fault locator

o Optical fiber fault detection

o Optical fiber breakpoint/bend location

o End-to-end optical fiber identification

o Two operating modes (pulse/continuous red light)

• Light source:

o CW and multiple modulated light output

o Adjustable output power (adjusting range: 4dB; stepping: 2dB)

o Dual wavelength [1310nm, 1550nm

- Conforms to EN61326-1:2013 and EN61326-2-2: 2013 standards

3. Structure

3.1 Structure Diagram

LIN-T UT63D ▲ 4.0000 mm U763D OPTICAL MULTIMETER (PONEW METTER/FL) UP55

Auto off symbol Visual fault locator symbol Wavelength Battery level symbol Flashlight symbol Calibration symbol Optical power Unit kHz km dBm

3.2 Key Description

3.2.1 UT692D/UT692G

No.KeyDescription
1Power key: Power the meter on by pressing this key within 1s and off by long press.
2This key enables the auto power off function (The top left corner of the LCD will display a reminder), which will power off the unit when no keys have been pressed for 10 minutes.
31. Press this key for 2s in the power on state to turn the flashlight on or off. The flashlight symbol will be displayed in the top left corner of the LCD.2. Press the "LIGHT" key once in the power on state to turn the LCD backlight on or off. If no keys have been pressed within 2 minutes, the LCD backlight will be automatically turned off. The backlight can be turned on again by pressing the "LIGHT" key once under this condition. The LCD backlight is turned on and the flashlight is turned off by default.
4Long press this key to automatically zero the optical power meter. At this time, the LCD is fully displayed to indicate the success.
5Press the "dB" key to toggle the meter's measurement mode between relative power (dB) and absolute power (dBm) to measure the optical power at the corresponding wavelength.
6Eight calibrated wavelengths (850, 980, 1300, 1310, 1490, 1550, 1625 and 1650 nm) can be selected by this key and displayed on the LCD simultaneously.
7Self-calibration mode: Press "ZERO" + "LIGHT" simultaneously (press again to exit the calibration mode) to enter the calibration mode. At this time, the character "CAL" is displayed in the top left corner of the LCD. Press the "LIGHT" key to add 0.05dB and "dB" key to decrease by 0.05dB at a time. This is used to calibrate the measurement error. After adjusting, press the power key to save the calibration data.
8Factory reset: Press "ZERO" + "AUTO OFF" simultaneously to restore factory settings.

3.2.2 UT693D

No.KeyDescription
1Power (AUTO OFF) key1. Short press to power on, and long press to power off.2. Short press this key in the power on state to turn the auto power off function on or off (on by default). The device automatically powers off after 10 minutes of no use.
2Short press to turn the red light on, short press in the red light state to flash it, and short press in the flash state to turn it off.
3Press the "LIGHT" key once in the power on state to turn the LCD backlight on or off (on by default). If no keys have been pressed within 2 minutes, the LCD backlight will be automatically turned off. The backlight can be turned on again by pressing the "LIGHT" key once under this condition.
4Long press this key to automatically zero the optical power meter. At this time, the LCD displays "CLR" to indicate the success.
5Press the "dB" key to toggle the measurement mode between relative power (dB) and absolute power (dBm) to measure the optical power at the corresponding wavelength.
6Eight calibrated wavelengths (850, 980, 1300, 1310, 1490, 1550, 1625 and 1650 nm) can be selected by this key.
7Self-calibration mode: Press "ZERO" + "LIGHT" simultaneously (press again to exit the calibration mode) to enter the calibration mode. At this time, "CAL" is displayed on the LCD. Press the "LIGHT" key to add 0.05dB and "dB" key to decrease by 0.05dB at a time. This is used to calibrate the measurement error. After adjusting, press the power key to save the calibration data.
8Factory reset: Press "ZERO" + "SB" simultaneously to restore factory settings.

3.2.3 UT696

No.KeyDescription
1Power (ALTO OFF) key1. Short press to power on, and long press to power off.2. Short press this key in the power on state to turn the auto power off functionon or off (on by default). The LCD prompts "0" when the function is on.
2Press the "LIGHT" key for 2s in the power on state to turn the flashlight on or off.
Press the "LIGHT" key once in the power on state to turn the LCD backlight on or off.If no keys have been pressed within 2 minutes, the LCD backlight will beautomatically turned off.
3Short press to attenuate the light source by 2dB (-4dBm→-6dBm→-8dBm→-10dBm)
4Short press to increase the light source by 2dB(-10dBm→-8dBm→-6dBm→-4dBm
5Select and turn on the corresponding wavelength light source (1310nm → 1550nm→ 1310nm cycle by default).
6Short press to switch the frequency (0Hz → 270 Hz → 1000 Hz → 2000 Hz →0 Hz cycle by default)
7Factory reset: Press "△" + "MODE" simultaneously to restore factory settings.

3.2.4 UT697

No.KeyDescriptionRemark
Optical power meter modePower (AUTO OFF) key1. Short press to power on, and long press to power off.2. Short press this key in the power on state to turn the auto power off function on or off (on by default).The LCD prompts “( )” when the function is on.The device defaults to optical power meter mode when it is powered on.
Short press to turn the LCD backlight on or off (on by default). If no keys have been pressed within 2 minutes, the LCD backlight will be automatically turned off.
Long press “ZERO” to automatically zero the optical power meter. At this time, the LCD flashes “CLR” twice to indicate the success.
Press the "dB" key to toggle the measurement mode between relative power (dB) and absolute power (dBm).The device defaults to absolute power when it is powered on.The relative power is shown as a ratio to the absolute power.
Eight calibrated wavelengths (850, 980, 1300, 1310, 1490, 1550, 1625 and 1650 nm) can be selected by this key.The last used wavelength is selected by default when the device is powered on.
Switch from optical power meter mode to light source mode.
Self-calibration mode: Press “ZERO” + “LIGHT” simultaneously (press again to exit the calibration mode) to enter the calibration mode. At this time, “CAL” is displayed on the LCD. Press the “LIGHT” key to add 0.05dB and “dB” key to decrease by 0.05dB at a time. This is used to calibrate the measurement error. After adjusting, press the power key to save the calibration data.Only valid in the optical power meter mode
Factory reset: Press “ZERO” + “MODE” simultaneously to restore factory settings.Only valid in the optical power meter mode
Light source modePower (AUTO OFF) key1. Short press to power on, and long press to power off.2. Short press this key in the power on state to turn the auto power off function on or off (on by default).The LCD prompts “( )” when the function is on.The device defaults to optical power meter mode when it is powered on.
Short press to turn the LCD backlight on or off (on by default). Ifno keys have been pressed within 2 minutes, the LCD backlight will be automatically turned off.
Short press “STEP” to attenuate the light source by 2dB(-4dBm → -6dBm → -8dBm → -10dBm)When the light source and optical power are switched, the current power output state is maintained. After the device is rebooted and the wavelength is selected, the default output optical power is -4dBm (at 0Hz).
Short press “FREQ” to switch the frequency(0Hz → 270Hz → 1000Hz → 2000Hz cycle)Default memory for last used frequency; 0Hz by default after rebooting
Select and turn on the corresponding wavelength light source (OFF → 1310nm → 1550nm → 1310nm cycle).Default memory for last used wavelength; OFF by default after rebooting
Switch from light source mode to optical power meter mode.

4. Specifications

4.1 Technical Indexes

ItemDescriptionOPTICAL POWER METEROPTICAL MULTIMETEROPTICAL LIGHT SOURCEOPTICAL MULTIMETER
UT692D/UT692GUT693DUT696UT697
Optical power meterWavelength range800nm-1700nmX
Calibrated wavelength850nm, 980nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm, 1650nm
Measurement range-70dBm→10dBm (UT692D,UT693D,UT697), -50dBm→26dBm (UT692G)
Uncertainty±5%
Display resolutionLinear: 0.1%, logarithmic: 0.01dBm
ConnectorUniversal connector FC/SC/ST
Detector typeInGaAs
Visual fault locatorWavelength650nm±10nmXXX
Power10mW (measurable optical fiber length: 8~10km)
ModeContinuous/Pulse mode
ConnectorUniversal connector FC/SC/ST
Light sourceWavelengthDual wavelength: 1310nm, 1550nmXX
Typical output optical power-4dBm
Adjustable output optical power-4dBm, -6dBm, -8dBm, -10dBm
Internal modulation0Hz/270Hz/1000Hz/2000Hz
Luminescent deviceFP-LD
Optical interfaceFC/PC
Applicable optical fiberSM, MM
FlashlightFlashlight functionXX

Remarks:

1) Wavelength range: the calibrated operating wavelength range from 800nm to 1700nm, in which the optical power meter can work under specified index.

2) Measurement range: the range in which the maximum power can be measured according to the specified index. 3) Uncertainty: the error between the measurement results of a given optical power and a standard optical power.

4.2 General Parameters

ItemDescription
Power supply1.5V AA alkaline battery (3 pcs)
Low battery indicationLow battery indication at around 3.5V, auto power off at around 3.3V
Auto power offAuto power off after 10 minutes of inactivity
Dimensions189mm×87mm×45mm
Drop height2m
Operating temperature0°C~40°C
Storage temperature-10°C~50°C
Operating humidity20~75% RH
Storage humidity10~90% RH
Altitude≤2000m
CertificationCE, RoHS, IP65

5. Operating Instructions

5.1 Measurement of Absolute and Relative Power (UT692D, UT692G, UT693D, UT697)

5.1.1 Absolute Power Measurement

Set the test wavelength and access the test optical signal. Then the screen will display the measured linear value (in mw, nw, pw) and nonlinear value (in dBm) of the absolute optical power.

5.1.2 Relative Power (Loss) Measurement (used in conjunction with light source)

Relative power measurement is mainly used to measure insertion loss or fiber link loss.

a) Use a standard test jumper to connect the output port of the light source to the detection port of the optical power meter.

b) Set the test wavelength and access the test optical signal. Then the screen will display the measured linear value (in mw, nw, pw) and nonlinear value (in dBm) of the absolute optical power.

c) Press the "dB" key. The absolute optical power measured by the optical power meter will be saved as the reference power value and displayed as xx.xx dBm on the second line of the screen.

d) Connect the jumper to be tested to the light source and the optical power meter. The difference between the current optical power value and the reference power value will be calculated by the optical power meter and displayed as yyy dB on the third line of the screen, which is approximately insertion loss of the jumper.

Note

① P (Reference power value) (dBm) = p (Light source output power) (dBm) - L (Insertion loss of the standard test jumper) (dB)

② L (Insertion loss of the jumper to be tested) (dB) = |P (reference power value) (dBm) - p (current power value) (dBm)| - L (Insertion loss of the standard test jumper) (dB)

5.1.3 Frequency identification function (UT692D UT692G, UT693D, UT697)

When connected to the light source with 270Hz, 1000Hz or 2000Hz signal, the optical power meter will automatically recognize the frequency and display XXXX Hz on the LCD.

5.2 Visual Fault Locator Function Test (UT693D)

1) Open the dust cap and insert the optical fiber under test into the interface of the visual fault locator.

2) Press the "■" key in the power on state, and select the continuous red light or pulse mode to test.

3) After the test, pull out the optical fiber, cover the dust cap, and then turn off the device.

5.3 Light Source Function Test (UT696, UT697)

Note: The light source needs to be used with an optical power meter.

1) Open the dust cap and tighten the fiber jumper to the light source output port.

2) Connect the other end of the fiber jumper to the test device (such as an optical power meter).

3) Turn on the light source, and select the corresponding output wavelength and frequency (UT697 needs to be switched to the light source mode first).

4) Turn on the test device, and select the same wavelength as the light source. The information such as the optical power output by the light source will be displayed on the test device.

5) After the test, pull out the optical fiber, cover the dust cap, and then turn off the device.

6. Standard Configuration

Host device 1 pc

User manual 1 pc

  1. SV AA alkaline battery — 3 pcs Cath box — 1 pc

Cloth bag 1 pc SC connector for light source 1pcs (UT696, UT697 only)

  1. Common Troubleshooting
Fault PromptPossible CauseSolution
LCD displays weaklyLow batteryReplace the battery
Booting up cannot be displayedLow battery or other causesReboot or replace the battery
LCD displays abnormal dataThe connector is faulty, dirty or lockedReconnect the connector and clean the sensor

8. Daily Maintenance

- Please keep the end face of the sensor clean, free from grease and contamination. Do not use unclean or non-standard adapter connectors. Do not insert the end face with poor polishing.

- Please stick to a kind of adapter as far as possible.

- Once the equipment is not in use, please cover it with a dust cap immediately.

- Please insert and remove the optical adapter connector carefully to avoid scratches on the port.

- Please wipe the sensor surface with a special cleaning swab in the circumferential direction gently and regularly.

- When the device is not in use for a long time, please remove the battery to prevent the battery from rot and the device from damage.

UNI-T.

UNI-TREND TECHNOLOGY (CHINA) CO., LTD.

No. 6, Gong Ye Bei 1st Road,

Songshan Lake National High-Tech Industrial

Development Zone, Dongguan City,

Guangdong Province, China

Tel: (86-769) 8572 3888

www.uni-trend.com

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Uni-T

Model : UT697

Category : Measurement