| Product Type | PTZ Controller Keyboard |
| Model Number | KBDPTZ1 |
| Brand | Speco Technologies |
| Dimensions (L x W x H) | 13.0 x 6.5 x 2.5 inches |
| Weight | 2.5 lbs (1.13 kg) |
| Power Supply | 12V DC, 500mA |
| Display | 2-line LCD with backlight |
| Joystick | 3-axis proportional joystick |
| Control Interface | RS-485 / RS-422 (via RJ-45) |
| Camera Protocols | Pelco P, Pelco D, Speco, others |
| Preset Positions | Up to 255 |
| Main Functions | Pan, Tilt, Zoom, Focus, Iris, Preset, Pattern, Tour, Acknowledge Alarms |
| Connection Type | RJ-45 daisy chain for multiple controllers |
| Construction | Metal chassis with non-slip rubber feet |
| Mounting | Desktop; optional rack mount kit |
| Included Accessories | Power adapter, RJ-45 crossover cable, user manual |
| Warranty | 1 year limited |
| Cleaning Instructions | Wipe with dry cloth; do not use liquid cleaners |
| Repairability | No user-serviceable parts; contact Speco support |
Frequently Asked Questions - KBDPTZ1 Speco Technologies
User questions about KBDPTZ1 Speco Technologies
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Remote control in PDF format for free! Find your manual KBDPTZ1 - Speco Technologies and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. KBDPTZ1 by Speco Technologies.
USER MANUAL KBDPTZ1 Speco Technologies
Please read this manual thoroughly before operation and keep it handy for further reference.
WARNING & CAUTION

CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (ORBACK). NO USER SERVICE A BLE P ARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The lighting flash with an arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (serving) instructions in the literature accompanying the appliance
INFORMATION -This equipment has been tested and found to company with limits for a class a digital device Pursuant to part 15 of the FCC rules. These limits are designed to provide rea so nable protection again sthar mful Inter fer ence W hen the equ ipme nts o perat ed in a co mmer cial env iro nmen t.
This equipment generates, uses, and Can Radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may Cause Harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which Case the user will be required to correct the interference at his own expense.
WARNING – Change or modification not expressly approved by the manufacturer could void the user's authority to operate the equipment
CAUTION : To prevent electric shock and risk of fire hazards.
DO NOT use power sources other than that specified.
DO NOT expose this appliance to rain or moisture.
This installation should be made by a qualified service person and should conform to all local codes.
IMPORTANT SAFEGUARDS
1. READ AND RETAIN INSTRUCTIONS
Read the instruction manual before operating the equipment. Retain the manual for future reference.
2. CLEANING
Turn the unit off and unplug from the power outlet before cleaning. Use a damp cloth for cleaning. Do not use harsh cleansers or aerosol cleaners.
3. ATTACHMENTS
Do not use attachments unless recommended by manufactured as they may affect the functionality of the unit and result in the risk of fire, electric shock or injury.
4. MOISTURE
Do not use equipment near water or other liquids.
5. ACCESSORIES
Equipment should be installed in a safe, stable location. Any wall or shelf mounting accessory equipment should be installed using the manufactures instructions. Care should be used when moving heavy equipment. Quick stops, excessive force, and uneven surfaces may cause the equipment to fall causing serious injury to persons and objects.
6. VENTILATION
Openings in the equipment, if any, are provided for ventilation to ensure reliable operation of the unit and to protect if from overheating. These openings must not be blocked or covered
7. POWER SOURCES
The equipment should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied at the installation location, contact your dealer. For equipment designed to operate from battery power, refer to the operating instructions.
8. GROUNDING OR POLARIZATION
Equipment that is powered through a polarized plug (a plug with one blade wider than the other) will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. Do not defeat the safety purpose of the polarized plug.
Alternate Warning: If the equipment is powered through a three way grounding type plug, a plug having a third (grounding) pin, will only fit into a grounding-type power outlet. This is a safety feature. Do not defeat the safety purpose of the grounding type plug. If your outlet does not have the grounding plug receptacle, contact your local electrician.
9. CORD AND CABLE PROTECTION
Route power cords and cables in a manner to protect them from damage by being walked on or pinched by items places upon or against them.
10. LIGHTNING
For protection of the equipment during a lightning storm or when it is left unattended and unused for long periods of time, unplug the unit from the wall outlet. Disconnect any antennas or cable systems that may be connected to the equipment. This will prevent damage to the equipment due to lightning or power line surges.
11. OVERLOADING
Do not overload wall outlets and extension cords as this can result in a risk of fire or electric shock.
12. SERVICING
Do not attempt to service the video monitor or equipment yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
13. DAMAGE REQUIRING SERVICE
Unplug the equipment from the wall outlet and refer servicing to qualified service personnel under the following conditions:
A. When the power supply cord or the plug has been damaged.
B. If liquid has spilled or objects have fallen into the unit.
C. If the equipment has been exposed to water or other liquids.
D. If the equipment does not operate normally by following the operating instructions, adjust only those controls that are covered by the operating instructions. Improper adjustment of other controls may result in damage to the unit.
E. If the equipment has been dropped or the casing damaged.
F. When the equipment exhibits a distinct change in performance.
14. REPLACEMENT PARTS
When replacement parts are required, be sure the service technician uses replacement parts specified by the manufacturer or that have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards.
15. SAFETY CHECK
Upon completion of any service or repairs to the equipment, ask the service technician to perform safety checks to verify that the equipment is in proper operating condition.
16. FIELD INSTALLATION
The installation of equipment should be made by a qualified service person and should conform to all local codes.
:: TABLE OF CONTENTS
CHAPTER 1 INTRODUCTION
In This Manual 06
Features 06
Before installation 06
Hardware Overview 07
System Configuration and Wiring 09
CHAPTER 2 SYSTEM INSTALLATION & TYPICAL APPLICATIONS
System Installation 10
PTZ SETUP 10
MAIN SETUP 11
JOYSTICK CALIBRATION 12
EASY SETTING FUNCTION (E.S.F) 13
SPECIFICATIONS 13

natural_image
Line drawing of a joystick controller with control panel and scroll wheel (no text or symbols):: LIMITATION OF LIABILITY
THE INFORMATION IN THIS PUBLICATION IS BELIEVED TO BE ACCURATE IN ALL RESPECTS, HOWEVER, WE CANNOT ASSUME RESPONSIBILITY FOR ANY CONSEQUENCES RESULTING FROM THE USE THERE OF. THE INFORMATION CONTAINED HEREIN IS SUBJECT TO CHANGE WITHOUT NOTICE. REVISIONS OR NEW EDITIONS TO THIS PUBLICATION MAY BE ISSUED TO IN CORPORATE SUCH CHANGES.
CHAPTER 1 INTRODUCTION
In This Manual
Overview | This manual covers the operation of the KBDPTZ1 keyboard.
KBDPTZ1
This remote keyboard is an accessory for PTZ dome camera, etc. It allows the user to control from 1 to 255 cameras.
Features
- Controls from 1 \~ 255 cameras.
- Multiple protocol supported in each channel
- RS 485/RS-422 communication (Tx : 3 port, Trx :1 port).
- Programmable user preferences. (preset, tour, group, etc.).
■ Built-in 3-Axis proportional joystick - Easy upload programmed data via serial communication port of PC.
■ Built-in 2 lines character LCD. - User password support.
- Designed for desktop use
- programmable transmission speed for each ID. (2.4–57.6kbps)
Note: units should be set to the communication protocol and the same baud rate.
Before installation
This keyboard system must be installed by qualified service and installation personnel.
Perform the following steps to install the keyboard system.
A. Unpack all components.
B. Place the keyboard in a convenient location.
C. Decide on the configuration method.
D. Use one of the following sections to configure the wiring.
Note: Carefully and completely read the manuals for each piece of equipment before attempting to install and connect the equipment.

CHAPTER 1 INTRODUCTION
Hardware Overview
Hardware Components
This remote keyboard contains easy to use control keys on the front and simple input and output connectors on the back.
Control Buttons & Connection
The unit provides the primary operator interface. Most operations are one or two button presses. The following Table contains a description for each buttons on the keyboard and port of cable connection. Use Figure 1 and Figure 2 as a reference.

| Number | Button | Description |
| 1 | ESC/POWER[5YAB] | Pressing the ESC/POWER button enters the Power on/off or escape key.Right description led on (red). Pressing it again exits the POWER OFF.(Push the [IMAGE] button (about 2–3 seconds) and then POWER OFF) |
| 2 | LCD DISPLAY16 x 2 Graphic display | Displays Camera ID, Protocol, function status, general status, etc. |
| 3 | Numbers09 | Camera ID setting value change ,PTZ setup (1+ ), Main setup (2+ ) |
| 4 | ControllerFunction keys![]() | Hold : System locking {Unlocking : Input the Pass word 4 digit ****}SHIFT/TURBO : SHIFT-Key for special function (Customize)/ TURBO -High SpeedAUX : External equipment on/offSET : Ptz and main setup (1 + ), (2+ )IRES CLOSE : Camera Iris closeIRIS OPEN : Camera Iris open |
| 5 | Function keys![]() | F1 – MENU/AUTO : Function Keys (Preset, Tour, Pattern, Scan, Auto).MENU :Used for Camera (Pan/Tilt) Menu adjustment. |
CHAPTER 1 INTRODUCTION
| Control buttons (continued) | ||
| Number | Button | Description |
| 6 | ![]() | Camera Focus control |
| Camera Zoom control | ||
| 7 | ![]() | MOUSE ON/OFF (MOUSE FUNCTION KEY 2-3 Seconds push)MOUSE CHARACTER DESCRIPTION WILL BE DISPLAY [WDS PEL-D 2.4K]ID:001 MOUSE |
| Number | Item | Description |
| 1 | ![]() | Telemetry Joystick Bit allows precise control of Pan/Tilt/Zoom |
| 2 | ![]() | DC 12V Input, 140 mA |
| 3 | ![]() | Universal Serial Bus Port, USB Mouse function(External Equipment communication port) |
| 4 | ![]() | RS-485/RS-422 communications.(Tx/Rx : 3 port , Trx :1 port) |
| 5 | Program | Download connector (For Program Update) |
CHAPTER 1 INTRODUCTION
System Configuration and Wiring
Basic
Installation
Use the Keyboard Configuration when only one keyboard is connected to the controlled units. Connect the RS-485 output port of Remote keyboard to RS-485 input port of the first controlled unit using the terminal block flowchart
graph TD
A["DC 12V"] --> B["Dome 1"]
A --> C["Dome 2"]
A --> D["Dome 3"]
A --> E["Dome 4"]
B --> F["RS-485"]
C --> G["RS-422"]
D --> H["RS-485"]
E --> I["RS-422"]
J["VIDEO"] --> K["BNC MONITOR"]
L["SMPLEX"] --> M["RS-485"]
N["HALF DUPLEX"] --> O["RS-422"]
P["FULL DUPLEX"] --> Q["RS-422"]
CHAPTER 2 SYSTEM INSTALLATION & TYPICAL APPLICATIONS
System Installation
Keyboard Installation Before you start connecting the keyboard equipment to your system, make sure the units to be controlled are completely installed and everything is working correctly. Before use of this keyboard, you should set the protocol and baud rate (2.4\~57.6kbps) in the PTZ SETUP mode. Use the following steps to set the communication protocol and baud rate.PTZ SETUP
PTZ SETUP PTZ Setup mode, select 1+ SET , (2\~3 seconds) setup screen allows you to make change ench programmable clause. Note: The baud rate must be the same between the controlled unit and the keyboard. flowchart
graph TD
A["PTZ SETUP"] --> B["[ PTZ SETUP 1 "] PASSWORD[" ***** "]
B --> C["[ PTZ SETUP 1 "] 1. ADDRESS : 001]
C --> D["[ PTZ SETUP 1 "] 2. MODEL : PEL]
D --> E["[ PTZ SETUP 1 "] 3. PROTOCOL : PEL-D]
E --> F["[ PTZ SETUP 1 "] 4. BAUDRATE : 2.4 K]
F --> G["[ PTZ SETUP 1 "] 5. PARITY : NONE]
G --> H["[ PTZ SETUP 1 "] 6. PROP : ON]
H --> I["[ PTZ SETUP 1 "] 7. SAVE]
I --> J["[ PTZ SETUP 1 "] 8. EXIT]
K[": PASS WORD INPUT (4 DIGITS)"] --> L[": ADDRESS CHANGE (1~255) + 📣"]
L --> M[": MODEL CHANGE (WDS/WCY/PEL...ETC)"]
M --> N[": PROTOCOL CHANGE (PEL-D/PEL-P/WON-D, ../ETC)"]
N --> O[": BAUDRATE CHANGE (2.4 KBPS~57.6 KBPS)"]
O --> P[": PARITY CHANGE (NONE/EVEN/ODD)"]
P --> Q[": PROP (ON/OFF) : Prpprotional speed control"]
Q --> R[": SETUP DATA SAVE"]
R --> S[": MENU EXIT"]
T[": Command eecution."] --> U[": SETUP MENU STAGE MOVE"]
CHAPTER 2 SYSTEM INSTALLATION & TYPICAL APPLICATIONS
MAIN SETUP
MAIN SETUP
Main Setup mode, select 2+ SET . (2\~3 seconds) setup screen allows you to make change ench programmable clause. Note: The baud rate must be the same between the controlled unit and the keyboard. MAIN SETUP flowchart
graph TD
A["[ MAIN SETUP "]
PASSWORD[" ***** "] --> B["↓"]
B --> C["[ MAIN SETUP "]
1. VER : *.**]
C --> D["↓"]
D --> E["[ MAIN SETUP "]
2. DATE : 20*****]
E --> F["↓"]
F --> G["[ MAIN SETUP "]
3. TITLE SET : ABC]
G --> H["↓"]
H --> I["[ MAIN SETUP "]
4. CONTROL ID : NO.]
I --> J["↓"]
J --> K["[ MAIN SETUP "]
5. DVR SPD : 9.6K]
K --> L["↓"]
L --> M["[ MAIN SETUP "]
6. COMM : RS422]
M --> N["↓"]
N --> O["[ MAIN SETUP "]
7. SLEEP : OFF]
O --> P["↓"]
P --> Q["[ MAIN SETUP "]
8. BUZZER : ON]
Q --> R["↓"]
R --> S["[ MAIN SETUP "]
9. BACKLIGHT : AUTO]
S --> T["↓"]
subgraph Inputs
U[": Cursor move"] --> V[": Character Select"]
V --> W["[ TITLE SET ABC"] --> X["ENT"]
Y[": ID No. Change"] --> Z[": ID No. Change"]
AA[": 2.4 KBPS~57.6 KBPS"] --> AB[": ID No. Change"]
AC[": RS422 / RS485"] --> AD[": ID No. Change"]
AE[": OFF/ 1Min/ 5Min/10Min/30Min/1 (Hour)"] --> AF[": Off/ 1Min/ 5Min/10Min/30Min/1 (Hour)"]
AG[": OFF/ ON"] --> AH[": Off/ ON"]
AI[": OFF/ ON/AUTO"] --> AJ[": Off/ ON/AUTO"]
end
CHAPTER 2 SYSTEM INSTALLATION & TYPICAL APPLICATIONS
flowchart
graph TD
A["MAIN SETUP\n10. MOUSE SET :ON"] --> B["4 DIGITS (Default :0000)"]
B --> C["FACTORY SET"]
C --> D["ALL DATA\nINITIALIZED"]
D --> E["JOYSTICK\nALIBRATION"]
A --> F["MAIN SETUP\n11. PASSWORD: *****"]
F --> G["4 DIGITS (Default :0000)"]
G --> H["FACTORY SET"]
H --> I["ALL DATA\nINITIALIZED"]
I --> J["JOYSTICK\nALIBRATION"]
A --> K["MAIN SETUP\n12. FACORY SET"]
K --> L["4 DIGITS (Default :0000)"]
L --> M["FACTORY SET"]
M --> N["ALL DATA\nINITIALIZED"]
N --> O["JOYSTICK\nALIBRATION"]
K --> P["MAIN SETUP\n13. SAVE/EXIT"]
P --> Q["4 DIGITS (Default :0000)"]
Q --> R["FACTORY SET"]
R --> S["ALL DATA\nINITIALIZED"]
S --> T["JOYSTICK\nALIBRATION"]
style A fill:#f9f,stroke:#333
style B fill:#ccf,stroke:#333
style C fill:#cfc,stroke:#333
style D fill:#fcc,stroke:#333
style E fill:#cff,stroke:#333
style F fill:#ffc,stroke:#333
style G fill:#fcc,stroke:#333
style H fill:#ffc,stroke:#333
style I fill:#fcc,stroke:#333
style J fill:#fcc,stroke:#333
style K fill:#ffc,stroke:#333
style L fill:#fcc,stroke:#333
style M fill:#ffc,stroke:#333
style N fill:#fcc,stroke:#333
style O fill:#fcc,stroke:#333
style P fill:#ffc,stroke:#333
style Q fill:#fcc,stroke:#333
style R fill:#ffc,stroke:#333
style S fill:#fcc,stroke:#333
style T fill:#fcc,stroke:#333
JOYSTICK CALIBRATION
flowchart
graph TD
A["JOYSTICK CALI."] --> B["PTZ OFFSET: **"]
B --> C["JOYSTICK CALI."]
C --> D["PAN LEFT: ***"]
D --> E["JOYSTICK CALI."]
E --> F["PAN RIGHT: ***"]
F --> G["JOYSTICK CALI."]
G --> H["PAN UP: ***"]
H --> I["JOYSTICK CALI."]
I --> J["PAN DOWN: ***"]
J --> K["JOYSTICK CALI."]
K --> L["ZOOM WIDE: ***"]
L --> M["JOYSTICK CALI."]
M --> N["ZOOM TELE: ***"]
N --> O["JOYSTICK SAVE"]
O --> P["<NO> YES"]
style A fill:#f9f,stroke:#333
style B fill:#f9f,stroke:#333
style C fill:#f9f,stroke:#333
style D fill:#f9f,stroke:#333
style E fill:#f9f,stroke:#333
style F fill:#f9f,stroke:#333
style G fill:#f9f,stroke:#333
style H fill:#f9f,stroke:#333
style I fill:#f9f,stroke:#333
style J fill:#f9f,stroke:#333
style K fill:#f9f,stroke:#333
style L fill:#f9f,stroke:#333
style M fill:#f9f,stroke:#333
style N fill:#f9f,stroke:#333
style O fill:#f9f,stroke:#333
style P fill:#f9f,stroke:#333
CHAPTER 2 SYSTEM INSTALLATION & TYPICAL APPLICATIONS
EASY SETTING FUNCTION (E.S.F)
EASY SETTINF FUNCTION (Number key + Function key) Number key + PSET/TOUR/PATT/SCAN/E.S.F is current position data (pan, tilt, focus, zoom data) save or call of Dome memoryDATA SAVE (SET)
 (PSET button 2 seconds push) → Current Position Saved Preset No 2  (TOUR button 2 seconds push) → TOUR MENU CALL OF DOMEDATA CALL (GOTO)
 (PSET button push) No 2 Preset position execution  (TOUR button push) No 3 TOUR Execution of DOME SPECIFICATIONS| Model | KBDPTZ1 |
| Keyboard Communication | Interface: RS-485 (Tx 3 port, Trx 1 port) P |
| an/Tilt operating distance :4700 ft (1029m) No 24 AWG wire | |
| Protocol: Multiple (Pelco-d, etc.) (Baud rate selectable) | |
| Connector Type Data | TERMINAL BLOCK(8p) |
| Keyboard Keypad | Rubber button |
| Numeric keypad and camera function key | |
| Joystick | Stick 3-axis, variable speed with zoom |
| Input Voltage | 12V DC or 9V batt (battery mode) |
| Power Consumption | Max.140mA |
| LCD Display | Graphic display : 16 * 2 Graphic display |
| Operating Temperature | 0 to 45 |
| Humidity | 10% -70 % non-condensing |
| Dimension & Weight | 280(W) x 174(D) x 92(H), Net : 0.7 Kg Gross: 1.7Kg |
| Packing include | WTX-1200A KEYBOARD, ADAPTOR |
| Packing include : BATT 9V(Alkaline), USB CABLE, MANUAL, TERMINAL BLOCK(8p) |
WARRANTY
speco technologies
LIMITED WARRANTY
THIS WARRANTY IS VALID ONLY ON PRODUCTS PURCHASED AND USED IN THE UNITED STATES OF AMERICA. THIS WARRANTY APPLIES ONLY TO THE ORIGINAL USER. SUBJECT TO CONDITIONS AND EXCLUSIONS FOUND BELOW, THIS PRODUCT IS WARRANTED AGAINST MANUFACTURING DEFECTS IN MATERIAL AND WORKMANSHIP FOR THE FOLLOWING PERIOD FOR PARTS AND LABOR:| SPECO TECHNOLOGIES CAMERAS: | 5 YEARS |
| SPECO TECHNOLOGIES MONITORS: | 1 YEAR |
| BALANCE OF SPECO TECHNOLOGIES LINE: | 1 YEAR* |
| * IR LEDs,Time lapse VCR Drum Assemblies & Heads: | 90-DAYS |