| Product Type | Microphone Sterilizer |
| Brand | ViolaWave |
| Model | Bullet |
| External Dimensions | Length: 258mm (10.15in), Diameter: 70mm (2.75in) |
| Internal Dimensions | Length: 220mm (8.66in), Diameter: 63mm (2.48in) |
| Weight (empty) | 300g (11oz) |
| Power Input | DC 5V 1A, Rated 5W |
| UV Lamp Wavelength | 185 nm |
| Operating Environment | 0°C to 50°C (32°F to 122°F), 15%-90% humidity |
| Sterilization Time | Less than 5 minutes |
| Microbial Elimination Rate | Up to 99.9% of harmful bacteria and viruses |
| Sterilization Technology | UV light and ozone (O3) |
| Battery Charging Time | Approximately 30 minutes |
| Power Indication | Red while charging, blinking red when fully charged, green when operating |
| Power Button | Single push to turn on/off |
| USB Connector | Yes, for charging and external power |
| Cap Lock | Screw-on cap to seal unit |
| Material Compatibility | Safe for all microphones |
| Warranty | 2 years from purchase date |
| Safety Precautions | Do not operate with cap open; avoid direct UV exposure; keep away from children |
Frequently Asked Questions - Bullet ViolaWave
User questions about Bullet ViolaWave
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Microphone in PDF format for free! Find your manual Bullet - ViolaWave and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Bullet by ViolaWave.
USER MANUAL Bullet ViolaWave
natural_image
Abstract geometric logo with nested purple triangles forming a V-shape (no text or symbols)VIOLAWAVE





BULLET USER'S GUIDE

natural_image
Professional microphone sterilizer with black case and multiple blue speakers (no visible text or symbols on devices)THANK YOU FOR CHOOSING BULLET BY VIOLAWAVE
ViolaWave is a groundbreaking sterilization system specifically designed for microphones.
A portable, convenient and state-of-the-art unit that provides you with the ultimate in sanitary efficiency.
Thanks to the use of a series of ultraviolet lamps designed to produce a small amount of ozone (O3) safe for your microphones, it will be possible to sterilize even in areas where UV rays cannot reach. This will guarantee a much deeper and more complete cleaning of the entire microphone, not just the capsule.
It's environmentally friendly and, unlike conventional spray disinfectants, does not contain chemicals. It deodorizes, reduces the risk of allergic reactions, and does not damage the electronic components.
Numbers of laboratory tests have shown that BULLET eliminates up to 99.9% of harmful bacteria and viruses in less than 5 minutes.

it is scientifically-proven : BULLET WORKS ! and it's safe to use on all of your microphones.
Specifications
External measurements: length 258mm / 10.15in - diameter 70mm / 2.75in
Internal measurements : length 220mm / 8.66in - diameter 63mm / 2.48in
Weight (when empty): 300g - 11oz
Input: DC5V 1A - Rated Power 5W
Operating Environment: 0° to 50° celsius 32° to 122° Fahrenheit - 15%-90% humidity
UV Lamps : 185NM
IMPORTANT SAFETY INFORMATION
CAUTION!
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE USING YOUR BULLET AND RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
To reduce the risk of fire, electric shock, or personal injury when using your product, basic safety precautions should be followed, including the following:
UV LIGHT PRECAUTION
Direct and overexposure to UV light can cause permanent eye damage.
- Do not operate the unit when the cap is open
• Germicidal ultraviolet rays are harmful to the eyes and skin - Avoid direct skin exposure to UV radiation
- Never look directly into the UV light source
• Inhaling Ozone may inflame and damage the airways

natural_image
Diagram showing a hand holding a circular object with a red prohibition symbol (no text or labels)GENERAL PRECAUTION
- This device is not intended for use by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been supervised or instructed to use of the appliance by a person who is responsible for their safety. Close supervision is necessary when the appliance is operating near these people.
- Keep this appliance out of reach of children. Children should be supervised to ensure that they do not play with the appliance.
- Do not use the appliance for purposes other than those intended.
- Never use any accessories or parts from other manufacturers that are not specifically recommended for this appliance. In such case, this appliance's warranty will be void.
- There are no self-serviceable parts inside the device. Do not attempt to open, service, or repair the sterilizer by yourself. All servicing should be performed by an authorized service representative. Failure to observe this requirement shall void any warranty, stated or implied.
- Only sterilize products that have been approved for sterilization and can withstand a moderate level of UV light exposure.
- Do not use chlorine or harsh chemicals to clean the appliance, as it may cause potentially cause damage to the unit.

VIOLAWAVE
GETTING STARTED



1 Power Button
2 USB Connector

natural_image
Illustration of hands holding a mechanical component with a green arrow indicating rotation (no text or symbols)Make sure the unit is turned off before unscrewing to remove the cap.

natural_image
Illustration of hands holding a mesh-wrapped object with a green arrow indicating direction (no text or symbols)Insert the microphone or the object you want to sterilize.

natural_image
Illustration of hands holding a mechanical component (no text or symbols visible)Close the unit and firmly lock the cap by screwing it until fully sealed.

natural_image
Illustration of a hand holding a mechanical component with a small knob (no text or symbols)Turn the unit on by pushing the power button that will light up green.

natural_image
Illustration of hands holding a mechanical component with a green arrow indicating rotation (no text or symbols)When the light goes off, the sterilization process is complete and you may open the unit.

natural_image
Illustration of hands holding a mesh-wrapped object with a green arrow indicating direction (no text or symbols)Remove the sterilized object.
GETTING STARTED
A convenient USB port allows you to fully charge the built-in battery in just 30 minutes or to operate BULLET while connected to an external power source.

natural_image
Illustration of hands using a tool to adjust or install a mechanical component, no text or symbols presentTo recharge your BULLET connect it to a power source such as a power bank, a computer, or a conventional outlet. Make sure to use the included USB cable. Plug it into the USB port on the side of the BULLET's cap.
The Power Button LED turns to solid red color while charging and will start blinking red when the internal battery is fully charged.
The unit can be turned on while is plugged into the USB to use power from an external source rather than the internal battery, the power button will be green. To set the unit back to charging, simply push the power button and it will return to color red again to indicate the charging status.
THE SERIAL NUMBER IS LOCATED UNDER YOUR BULLET LID

2 YEARS WARRANTY
If you experience a malfunction of any of our products, depending on the country and region you are in, you may either contact the dealer where you purchased the product from, or you can reach us directly at info@violawave.com.
We will ask you to ship your product to us ONLY IF we find it necessary to perform a factory repair or replacement. Our warranty is effective for 2 years (from the date of purchase of a new unit) and only for issues caused by our manufacturing defects. The warranty will be voided if the unit has been misused, abused, modified by any unauthorized parties.
A ONE-TIME free repair/replacement will be offered if the issue is caused by manufacturing defects.
Although you don't need to register your product, in order to process your request, we will ask for Proof of Purchase such as an invoice, receipt, order number, or credit card statement.
ViolaWave reserves the right to make changes in design or make additions to or improvements upon this product without incurring any obligation to install the same on products previously manufactured. Violawave is not responsible for injuries and/or damages related to the use of our products.
REGISTER NOW BY VISITING WWW.VIOLAWAVE.COM/ACCOUNT/REGISTER OR BY SCANNING THE QR CODE

REGISTER
At Violawave we are committed to bringing into the market an honest and effective line of Ultraviolet (UV) / Ozone sterilizing technology products.
The content and materials available on ViolaWave website are for information purposes only, intended to provide you the relevant information on the benefits and hazards of using UV and Ozone products, and are not intended to diagnose, prescribe or replace the advice of professionals.
Be reminded that our UV products are not designed to be used on the skin, the eyes, and any part of the body, among others. Inappropriate and improper use of UV products could be dangerous and harmful. Always keep the products away from and out of reach of children. If you have questions about the use of Violawave products feel free to send us an e-mail and please, always review the labeling appearing on the product.
Always be reminded that the products must be used with caution and in accordance with the proper use as indicated in the instructions and/or manuals that come together with the purchased products.
This product or this manual is not a substitute for compliance with the provisions of any and laws, legal requirements, rules, regulations that may apply to the UV products.
This product or this manual is not intended to be a substitute for professional medical advice, diagnosis, or treatment. Always seek the advice of your physician or other qualified health care provider with any questions you may have regarding a medical condition or treatment and before undertaking a new health care regimen, and never disregard professional medical advice or delay in seeking it because of something you have read on this website
Reliance on any information provided by this manual, or by others appearing on our websites are solely at your own risk.


ViolaWave
© 2021 KeeKaz LLC. All rights reserved.
Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of Keekaz LLC.
The ViolaWave logo is a trademark of KeeKaz, LLC. registered in the U.S. and other countries.
Use of the ViolaWave logo for commercial purposes without the prior written consent of KeeKaz may constitute trademark infringement and unfair competition in violation of federal and state laws.
Every effort has been made to ensure that the information in this manual is accurate. KeeKaz is not responsible for printing or clerical errors.
ViolaWave - KeeKaz
12400 Ventura Blvd, Studio City, CA 91604
www.violawave.com
info@violawave.com