NF-805 - Circuit Tester Noyafa - Free user manual and instructions
Find the device manual for free NF-805 Noyafa in PDF.
| Product Type | Circuit Tester |
| Brand | Noyafa |
| Model | NF-805 |
| Dimensions | Approximately 150 x 70 x 30 mm |
| Weight | About 200 g |
| Power Source | 9V battery (included) |
| Voltage Detection Range | 12V - 600V AC/DC |
| Continuity Test | Yes, with audible beep |
| Polarity Indication | LED and buzzer |
| Wire Break Detection | Yes |
| NCV (Non-Contact Voltage) Detection | Yes, for AC voltage |
| Test Leads | Removable, with insulated probes |
| Display | LED indicators for voltage level and polarity |
| Safety Rating | CAT II 600V |
| Operating Temperature | 0°C to 40°C |
| Storage Temperature | -10°C to 50°C |
| Humidity | ≤80% RH |
| Maintenance | Clean with dry cloth; replace battery when low |
| Spare Parts | Test leads, battery, carrying case |
| Repairability | Parts replaceable by user; consult manual |
| General Information | Use for testing electrical circuits, automotive, and household wiring |
Frequently Asked Questions - NF-805 Noyafa
User questions about NF-805 Noyafa
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Circuit Tester in PDF format for free! Find your manual NF-805 - Noyafa and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. NF-805 by Noyafa.
USER MANUAL NF-805 Noyafa
Circuit Tester
NF-805

User Manual
VER:1
1. Amplifier Probe Feature:
Use the Amplifier and Tone Generator set to quickly and accurately trace and identify wires or cables, even when in a bundle.
② Probe can work with any existing tone generator in the market.
③ Adjustable volume level (1-9) for various work environments.
④ 9V Battery provides up to 100 hours of use.
⑤ Plug receptacle for head set.
- Tone Generator Feature:

- Technical Parameter
| NF-805 Tone Generator | |
| Tone frequency | 0.6~2kHz |
| Max. testing distance | 1.5km |
| Max. working current | ≤slant 20mA |
| Tone mode | One / Two-note tone |
| Connector port | RJ11 (6 pin2c), Alligator clips |
| Compatible cables | De-enerized AC wire, telephone/twisted pair wire, all voice and data category rated cable, virtually any cable or wire. |
| Function selection | TONE/OFF/CONT |
| Short circuit/conduction test | Yes |
| Continuity test | 1 LED ( ≤slant 10Ω), Coaxial cable & normal solid/ stranded wire by alligator clips patch cord. |
| Max.signal voltage | 8Vp-p |
| Power inindicator | Yes |
| Phone line polarity indication | Yes |
| Phone line status indication | Yes |
| Live telecommunication equipment test and router test. | Yes |
| Voltage protection | DC 48V |
| Battery | NEDA 1604/ 6F22 DC9V×1pc(not included) |
| Dimension(L x W x D) | 65×58×34 mm |
| Weight | 97 g |
| NF-805 Amplifier Probe | |
| Frequency | 0.6~2kHz |
| The Max. working current | ≤slant 70mA |
| Start mode | Toggle switch |
| Earphone jack | 1 |
| Battery type | NEDA 1604/ 6F22 DC9V ×1pc(not included) |
| Dimension(L x W x D) | 230×56×25 mm |
| Weight | 116 g |
4. OPERATING INSTRUCTIONS
4.1 To Test Wires or Cables
CAUTION: Do not connect the Tone Generator in the TONE position to any wire or cable with an active DC circuit exceeding (48V)
① Connecting the Tone Generator, turn the switch to the TONE position, connect the line as follow:
a. For terminated working cables: connect Red test lead to the terminated wire and Black test lead to the earth or equipment ground.
b. For non-terminated or non-working cables: Black test lead connect to a non-terminated/non-working wire.
② Set the Amplifier Probe to the SCAN or LED position.
③ Turn on the probe volume thumbwheel, press the power button.
④ Adjust the volume with the volume control. Increase the volume to overcome noise, decrease to reduce interference.
⑤ Position the tip of the probe close to the insulation of each of the suspect conductors. The volume will be loudest on the wire connected to the tone generator.
⑥ In noisy or dark environments the signal LED provides and alternate method of identification. The signal LED will display a brighter RED the closer it is to the connected wire.
Note: There are a tone switch inside of the Tone Generator, provide one tone or dual tone selection. To adjust the tone, remove the battery cover and change the switch position.
4.2 Identifying Tip and Ring
① Switch the Tone Generator to the OFF position
② Connect the RED test lead to one line and the BLACK lead to the other line
③ The CONT LED indicates the status as below:
Green light
Red test lead at positive (+) polarity; Black test lead at negative (-) polarity.
No light :
a. Red test lead at negative (-) polarity; Black test lead at positive (+) polarity.
b. Exchange the red test lead and black test lead, if LED still not light on, the phone line maybe no service or fault
4.3 Identifying Line Condition: (only used for the analog phone lines.)
① Switch the Tone Generator to the OFF position
② Connect the RED lead to the TIP SIDE of the line and the BLACK lead to.
③ The CONT LED indicates the status as below:
a. Green color: Standby status.
b. Not bright or dim: Served line status.
c. Flashing: Incoming call ringing.
4.4 Verifying Lines:
(only used for the analog phone lines, cannot be used in the digital telephone.)
① Switch the Tone Generator to OFF
② Connect the RED lead to the TIP SIDE of the line and the BLACK lead to.
③ Connect the RED lead to the RING or TIP SIDE of the line and the BLACK lead to the other side of the line.
④ The 3 LEDs (TONE, LO BAT, and CONT) will all be FLICKERING when the test leads are connected to the subject pair.
4.5 Testing Continuity-CONT Mode
CAUTION:
Do not connect the Tone Generator in the CONT position to any wire or cable with an active DC circuit exceeding 48V.)
① Switch the Tone Generator to the CONT position. The CONT LED will display RED.
② Connect the wire leads to the wire pair under test.
③ If there is no continuity, the LED will display RED.
For continuity (<500Ohm), the LED will gradually diminish until there is NO Light.
4.6 Testing Continuity-TONE Mode
CAUTION :
Do not connect the Tone Generator in the TONE position to any wire or cable with an active DC circuit exceeding 48V.
① Switch the Tone Generator to the TONE position. The TONE LED will display RED.
② Connect the wire leads to the wire pair under test.
③ Use a headset or handset at the remote end.
④ An audible tone signals continuity.
5. Battery
① If the Amplifier Probe volume is low, replace the battery.
② Unscrew screw on battery cover.