Taylor 5460 - Thermometer

5460 - Thermometer Taylor - Free user manual and instructions

Find the device manual for free 5460 Taylor in PDF.

📄 1 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Taylor 5460 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Digital Instant-Read Thermometer
Brand Taylor
Model 5460
Temperature Range -58°F to 572°F (-50°C to 300°C)
Accuracy ±1°F (±0.5°C) from -4°F to 248°F (-20°C to 120°C)
Response Time 2-3 seconds
Display LCD with backlight
Probe Length 4.5 inches (11.4 cm)
Power Source 1 x CR2032 battery (included)
Auto-Off After 10 minutes of inactivity
Functions Instant read, hold button, °F/°C switch, max/min memory
Dimensions 5.25 x 2.1 x 0.8 inches (13.3 x 5.3 x 2 cm)
Weight 2.4 oz (68 g) with battery
Material Stainless steel probe, plastic body
Water Resistance Not waterproof; wipe clean only
Cleaning Wipe probe with damp cloth; do not immerse
Safety Do not leave in oven while cooking; hand wash only
Battery Replacement Replace CR2032 battery as needed
Warranty 1 year limited

Frequently Asked Questions - 5460 Taylor

How do I change between Fahrenheit and Celsius?
Press and hold the °F/°C button for 3 seconds until the display switches. The unit will remember your preference.
What is the temperature range of the Taylor 5460 thermometer?
The thermometer measures from -58°F to 572°F (-50°C to 300°C). It is suitable for both freezing and high-heat cooking.
How do I clean the thermometer probe?
Wipe the probe with a damp cloth or mild soap. Do not immerse the thermometer in water or put it in the dishwasher.
How long does the battery last and how do I replace it?
The CR2032 battery lasts approximately 300 hours of use. To replace, slide the battery cover off at the back of the unit and replace with a new CR2032 battery.
Can I leave the thermometer in the oven while cooking?
No, the Taylor 5460 is an instant-read thermometer meant for spot checks. Do not leave it in the oven as it is not oven-safe.
What should I do if the display shows 'HHH' or 'LLL'?
'HHH' indicates the temperature is above the maximum range (572°F/300°C). 'LLL' indicates below minimum (-58°F/-50°C). Remove from extreme conditions and allow to cool/warm.
How accurate is the Taylor 5460 thermometer?
It is accurate to ±1°F (±0.5°C) within the range of -4°F to 248°F (-20°C to 120°C). Higher and lower ranges have slightly reduced accuracy.
Can I use this thermometer for candy making or deep frying?
Yes, the wide temperature range makes it suitable for candy making, deep frying, and grilling. Ensure the probe is inserted into the food, not the pan wall.
Does the thermometer have an auto-off feature?
Yes, it automatically turns off after 10 minutes of inactivity to conserve battery life. You can wake it by pressing any button.
What is the best way to store the thermometer?
Store the thermometer in a dry place at room temperature. Avoid direct sunlight and extreme temperatures. The protective cap can be used to shield the probe.

User questions about 5460 Taylor

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermometer in PDF format for free! Find your manual 5460 - Taylor and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 5460 by Taylor.

USER MANUAL 5460 Taylor

Large face with bold, easy-to-read numbers
Records highest and lowest daily temperatures
Convenient push button and magnet reset
■ Temperature range: -40°F to 120°F/ -40°C to 50°C

SEPARATED FLUID:

The liquid in this thermometer may become separated or air bubbles may also appear in the clear liquid on the maximum side. This does not represent defect or damage. To reunite heavy liquid and eliminate air bubbles prior to thermometer use, please perform the following steps:

  1. Hold thermometer at the top as shown in Fig. 2 and strike the bottom end sharply against the palm of the other hand.
  2. Next, grasp the thermometer at the top (as in a tennis racquet grip, Fig.3) and swing the thermometer downward in an arc.
  3. Repeat the above steps as necessary to reunite the heavy liquid. Note: If the steps above do not remove the air bubbles or reunite the heavy liquid in the columns completely, hold the thermometer upright under hot tap water so the water washes over the temperature sensing bulb. Do NOT allow the columns to rise about 130^ . Hold the thermometer in an upright position to cool to room temperature. Wipe dry.

MOUNTING

For accurate minimum/maximum temperatures, always mount the thermometer in an upright position. Do not mount in direct sunlight or where there is a great deal of reflected light. To prevent further fluid separation, store the thermometer in an upright, top end up position.

RESET THERMOMETER

Press and hold the center button, this releases the markers. Hold until the markers rest on top of the heavy liquid columns. If the limit markers stick, remove the red magnet from the thermometer and place on the marker and move it down to the top of the liquid. Replace the magnet for future use. To obtain best results from the min/max thermometer, read and reset at least once daily.

Temperature Sensing Bulb
Reset Button Limit Markers Heavy

Liquid Columns

Taylor 5460 - RESET THERMOMETER - 2

natural_image Illustration of a hand holding a spring scale with an arrow indicating upward motion (no text or symbols)

(Fig 3)

DR / OUTDOOR XIMUM / MINIMUM RMOMETER

YLOR

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Taylor

Model : 5460

Category : Thermometer