SoleusAir PH5-13R-35S - Air conditioner

PH5-13R-35S - Air conditioner SoleusAir - Free user manual and instructions

Find the device manual for free PH5-13R-35S SoleusAir in PDF.

📄 16 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice SoleusAir PH5-13R-35S - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Portable Air Conditioner with Heat Pump
Model PH5-13R-35S
Cooling Capacity 13,000 BTU/h
Heating Capacity 12,500 BTU/h
Dehumidifier Capacity 60 pints/day
Power Input (Cooling) 1350W
Power Input (Heating) 1180W
Air Flow Volume 225 CFM
Power Source 115V ~ 60Hz, 12A (Cooling) / 11A (Heating)
Sound Pressure Level 46 dB(A)
Net Weight 88 lbs
Dimensions (W x H x D) 18.875" x 32" x 17.125"
Refrigerant R-410A
Operating Temperature (Cooling) 60.8°F – 109°F
Operating Temperature (Heating) 23°F – 89.6°F
Modes Auto, Cool, Heat, Dehumidify, Fan
Fan Speeds High, Medium, Low, Auto
Timer 1–24 hours (auto-on/off)
Sleep Mode Yes (via remote)
Air Filter Washable, clean every 2 weeks
Power Cord LCDI (Leakage Current Detection and Interruption)
Warranty 1 year limited

Frequently Asked Questions - PH5-13R-35S SoleusAir

How do I install the window kit?
Open the window or door, adjust the sliding panels to fit the opening, then close the window tightly onto the kit. The exhaust hose should be as short and straight as possible. See the manual for detailed steps.
How do I clean the air filter?
Turn off and unplug the unit. Remove the filter from the front and back compartments. Wash gently in warm water with mild detergent, rinse, and dry thoroughly out of sunlight before reinserting. Clean every two weeks or as needed.
What does the 'Bucket Full' indicator mean?
The emergency condensate tank is full. The unit will shut off automatically. To drain, pull the drain plug at the bottom back of the unit and collect water in a shallow pan. The tank capacity is about 1.5 liters. After draining, the unit will resume operation within a few minutes.
How do I set the timer?
When the unit is off, press the TIMER button; the hours will blink. Use ▼ or ▲ to set the desired hours for auto-on. When the unit is on, press TIMER to set auto-off hours. The timer is set when the display stops flashing. For remote control, set the clock first, then use T-ON and T-OFF buttons with MIN and HOUR.
Can I use an extension cord?
No, do not use an adapter plug or extension cord. Connect the unit directly to a correctly grounded outlet.
How do I switch between Celsius and Fahrenheit?
Press the ▼ and ▲ buttons simultaneously on the control panel or remote control to toggle between °C and °F.
Why is the unit not cooling?
Check that the exhaust hose and window kit are properly installed and vented outside. Ensure the filter is clean. Make sure the set temperature is below the room temperature. Also verify that the unit is in cooling mode and the room is not too hot (above 109°F).
How do I use sleep mode?
Sleep mode is available only with the remote control. Ensure the unit is in cooling or heating mode, then press the SLEEP button on the remote. The fan will run on low. In cooling mode, the set temperature will gradually increase by 2°F over 6 hours; in heating mode, it will decrease by 2°F.
What is the LCDI power cord?
The LCDI (Leakage Current Detection and Interruption) cord automatically cuts power if current leakage is detected, reducing fire risk. It has test and reset buttons. Test it monthly: plug in, press TEST (unit should shut off), then press RESET to resume.
How do I store the unit for winter?
Unplug the unit and drain any excess water from the back drain plug. Clean the filter and dry the unit. Store in a cool, dry place.

User questions about PH5-13R-35S SoleusAir

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual PH5-13R-35S - SoleusAir and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PH5-13R-35S by SoleusAir.

USER MANUAL PH5-13R-35S SoleusAir

Portable Air Conditioner with Heat Pump

Operating Instructions

Exterior view of a modern air purifier unit (no visible text or symbols on the device body)

Thank you for choosing a Soleus Air PH5 Series Portable Air Conditioner with Heat Pump. This owner's manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner.

For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:

Store Name: ____

Location:

Date Purchased: ____

Serial Number (located on back of unit): ____

IMPORTANT INSTRUCTIONS

Before installing and using your portable air conditioner, please read this owner's manual carefully. Store this manual in a safe place for future reference.

1) Always place the unit on a level surface.
2) Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual.
3) Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block or cover air inlet or outlet grilles.
4) The unit must be connected to a correctly grounded power supply.
5) Do not start or stop the unit by inserting or pulling out the power plug.
6) Do not use an adapter plug or extension cord.
7) Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.
8) Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this manual.
9) Do not let children play near this unit.
10) Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by the manufacturer or a qualified service technician.
11) When cleaning the unit, always turn the unit off and unplug the power cord.

PACKAGE CONTENTS

Portable Air Conditioner

Exhaust Hose (1)

Hose Adapter (1)

Window Kit Adapter (1)

Remote Control

AAA Batteries (2)

Window Kit - 3 Sliding Panels

Air Outlet Covers (1)

Owner's Manual

SPECIFICATIONS

• The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.
- The operational ambient temperature is between 23°F 109°F .
- Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
- Power consumption is measured when the fan runs at the highest speed setting.
• These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
- If the ambient temperature is higher than the max operating temperature or lower than the minimum operating temperature, the air conditioner may not work properly.

MODELPH5-12R-32SPH5-13R-35S
COOLING CAPACITY 12,000BTU/H 13,000 BTU/H
HEATING CAPACITY 12,000BTU/H 12,500 BTU/H
DEHUMIDIFIER CAPACITY 60 pts/Day 60 pts/Day
POWER INPUTCOOLING1320W1350W
HEATING1200W1180W
AIR FLOW VOLUME 225 CFM 225 CFM
POWER SOURCE115V 60Hz11.8A (COOLING)11A (HEATING)115V 60Hz12A (COOLING)11A (HEATING)
SOUND PRESSURE LEVEL 46 dB (A) 46 dB (A)
NET WEIGHT 88 Lbs88 Lbs
OPERATINGTEMPCOOLING60.8°F -109°F60.8°F -109°F
HEATING23°F -89.6°F23°F -89.6°F
DIMENSIONSUNIT18.875" W × 32" H × 17.125" D18.875" W × 32" H × 17.125" D
REFRIGERANTR-410AR-410A

LCDI POWER CORD AND PLUG

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.

The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the device has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:

  1. Plug power cord into wall outlet
  2. Press TEST Button, circuit should trip, cutting power to the air conditioner
  3. Press RESET button for use

If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations.

RESET TEST

WARNING:

  1. DO NOT press the TEST button while the air conditioner is operating.
  2. The TEST and RESET buttons should not be used as "ON" and "OFF" switches.
  3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
  4. The cord and plug are intended for indoor use only.

PRODUCT DIAGRAM
SoleusAir PH5-13R-35S - WARNING: - 1

PARTS & ASSEMBLY

PARTS

EXHAUST HOSE
HOSE ADAPTER EXHAUST HOSE WINDOW KIT ADAPTER

WINDOW KIT
Technical line drawing of a structural beam with flanges and supports (no text or symbols)

ASSEMBLY & INSTALLATION

INSTALLATION

When the unit is operating as an air conditioner, heater, or dehumidifier, the unit draws in fresh outdoor air and exhausts hot air (or cold air in heat mode) out of the room to complete the air exchange. When the unit is operating in fan mode, no outdoor air exchange takes place. The window kit and exhaust hose do not need to be installed when the unit is used as a fan.

NOTE: The supplied window kit can be installed in sliding windows and sliding glass doors up to 8 ft. long (approximate length).

MOUNTING THE EXHAUST HOSE

  • Choose a suitable location, near a grounded electrical outlet and suitable window or door. Remove packaging and locate components.
  • Extend both ends of the exhaust hose approximately 6 inches.
  • Screw the window kit adapter onto one end of the exhaust hose clockwise. Screw the hose adapter onto the other end of the exhaust hose clockwise.
  • Remove the outlet cover from the back of the unit by screwing them counter-clockwise, then lifting up.
  • Mount the exhaust hose onto the back of the unit by locking the hose adapter into place.

VENTING KIT INSTALLATION

NOTE: FOR THE PH5 THERE IS ONLY ONE EXHAUST HOSE TO INSTALL

Exterior view of a modern office building (no signage)

Close-up of a hand pressing down on a white electronic device (no visible text or symbols)

Person holding a white plastic container with a hand extending from it, in an indoor setting (no visible text or symbols)

Person handling a white plastic funnel outdoors, with an air conditioner unit in the background (no visible text or symbols)

Two white cylindrical objects placed on a green wall next to a window, no visible text or symbols.

Person opening a window with visible door and window frame (no text or symbols)

Person using a tool to cut or mark a white strip on carpet (no text or symbols visible)

Interior view of a window with green walls and a striped patterned rug on the right (no text or symbols visible)

Person sitting on a bench near a window, viewed from behind (no visible text or symbols)

Interior view of a room with a white robotic arm and striped fabric, no visible text or symbols

The venting kit must be installed in order for the unit to work correctly in the air conditioning, heating or dehumidifying mode. The venting kit does not need to be used while the unit is fanning.

The window kit has been designed to fit into most vertical and horizontal window openings. The window kit can also be used in a sliding door.

  1. Choose a suitable location, near a grounded electrical outlet and a suitable window or door. Remove packaging and locate components. (figure a)
  2. Remove the outlet covers from the back of the unit by screwing them counter-clockwise, then lifting up. (figure b)
  3. Pull out one end of the exhaust hose, then screw on the adapter clockwise. Repeat on other exhaust hose. (figure c)
  4. Pull out the opposite end of the exhaust hose, then screw on the window kit adapter clockwise. Repeat on other exhaust hose. (figure d)
  5. Mount the exhaust hoses onto the back of the unit. (figure e)
  6. Open the window or door and adjust the length of the window kit to fit the opening. (figure f) If necessary, mark the kit and cut down one end to properly fit the opening. (figures g & h)
  7. Attach the window kit adapters to the window kit. (figure i) Close the window or door tightly. (figure j) Your Portable Air Conditioner is now ready to cool!

NOTE: When using the venting system, keep the exhaust hose as short and straight as possible. The exhaust hose can be shortened, but it is not recommended to increase the length of the exhaust hose. Do not use an extension cord with your portable air conditioner.

NOTE: The Portable Air Conditioner above may differ from the unit described in this manual. The above directions and images show general directions for Soleus Air hose portable air conditioners.

WINDOW KIT ASSEMBLY

D C1 C2 A B

  1. Parts:
    A) 2 Track Screws
    B) 2 Wing Nuts
    C1 & C2) 2 Hose Panels, one Exhaust Hose Openings
    D) 1 Sliding Track Panel

Close-up of a white plastic panel with two small metallic components, placed on a dark surface (no text or symbols visible)

  1. Assembly:
    First, take the Track Screws (A) and screw one

Two white rectangular panels with small metallic pins, placed on a dark surface (no text or symbols visible)

  1. Next, take the Wing Nuts (B) and tighten them around each of the Track Screws (A). Do not tighten the Wing Nuts (B) all the way; make sure they are somewhat loose.

Close-up of a metallic tool with directional arrows pointing to its tip, mounted on a white surface (no text or symbols visible)

  1. Now, place the Sliding Track Panel (D) over the Track Screw (A) on Hose Panel (C1).

Technical line drawing of a structural beam with flanges and supports (no text or symbols)

Close-up of a white plastic panel with a small protrusion on the side (no visible text or symbols)

  1. Next, take the other Hose Panel (C2) and connect it to Hose Panel (C1) by placing the Sliding Track Panel (D) over the Track Screw (A) on Hose Panel (C2).

Connected D C1 C2

  1. The Hose Panels (C1 & C2) should now be connected using the Sliding Track Panel (D).

White elongated object with two small markings and three white arrows pointing downward (no text or symbols)

  1. To complete the assembly, tighten the wing Nuts (B) installed earlier. The finished Window Kit should resemble the image seen below.

CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS

CONTROL PANEL & LED CONTROL DISPLAY

CONTROL PANEL

TIMER TIME/TEMP DECREASE POWER TIME/TEMP INCREASE TIMER FAN SPEED MODE POWER FAN SPEED MODE LED CONTROL DISPLAY

LED CONTROL DISPLAY
AUTO A/C DEHUM. FAN HEA REMOTE RECEIVER FAN SPEED TIMER ON TIMER OFF TEMPERATURE AND TIMER INDICATOR OSCILLATION ON/OFF COMPRESSOR ON/OFF SLEEP MODE ON/OFF BUCKET FULL

CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS

CONTROL PANEL BUTTONS (Refer to the images on page 9)

1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off.
2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto mode, Air Conditioner, Dehumidifier, Fan only, and Heater mode.
3) Fan Speed Control - Press the FAN SPEED Button to cycle through the different fan speeds: High, Medium, and low. The fan speed can be visually distinguished by the speed of the digital air segments progressing out from the windmill fan image on the led control display. There is an additional auto speed setting that is enabled in only heating and cooling modes. This speed is next setting after low when pressing the speed control button. The speeds will cycle through in this order: High, Medium, Low, Auto. Each change in speed will be associated with a “beep” sound from the unit.
4) Temperature - Select the desired temperature by pressing either ▼ or ▲ key when using the unit in cooling or heating mode. The temperature indicator flashes to display the desired temperature setting. After the temperature is set, the unit will display this temperature setting until it is changed by the user. The led control display shows temperature in Celsius or Fahrenheit. Press the ▼ and ▲ simultaneously to change from C° to F°.
5) TIMER*- To program the Auto-on timer, first press the TIMER button when the unit is off. Once the TIMER button is pressed the hours will blink on the display. Press the ▼ or ▲ buttons to change the number to the desired hours for the unit to automatically turn on. To program the unit to turn off automatically press the TIMER button when the unit is on to set the off timer. The display will flash the hours to turn off the unit. Press the ▼ or ▲ buttons to change the hours to the desired time for the unit to automatically turn off. The timer is set when the auto-off time stops flashing.

1) Install the exhaust hose and window kit properly (see pages 7 & 8).
2) Plug the Power Cord into an electrical outlet.
3) Turn on the unit by pressing the POWER button on the control panel.

SoleusAir PH5-13R-35S - CONTROL PANEL BUTTONS (Refer to the images on page 9) - 1

4) Press the Mode button until the “” icon appears on the led control display
5) Press the ▲ or ▼ buttons until the desired room temperature appears on the control panel display. The temperature ranges from 61° F - 88° F ( 16° C - 31° C).
6) Select the desired fan speed by pressing the FAN button.

NOTE: During hot days, the unit will cool the room most efficiently by setting the temperature at the lowest setting and the fan speed on high. Reducing the length of the exhaust duct, insulating the exhaust hose and window kit, and keeping direct sunlight to a minimum will also improve the cooling efficiency.

Heating Mode

1) Install the exhaust hose and window kit properly (see pages 7 & 8).
2) Plug the Power Cord into an electrical outlet.
3) Turn on the unit by pressing the POWER button on the control panel.

SoleusAir PH5-13R-35S - Heating Mode - 1

4) Press the MODE button until the “ ” icon appears on the control panel display.
5) Press the ▼ or ▲ buttons until the desired room temperature appears on the control panel display. The temperature ranges from 61° F - 88° F ( 16° C - 31° C).
6) Select the fan speed by pressing the FAN button. It is recommended to set the fan speed to low.

NOTE: When heat mode is selected, the unit will shut down for 3-5 minutes, then start in heating mode.

NOTE: When the unit is running on heating mode, the exhaust hose is required and must be vented outside using the supplied window kit.

Dehumidifier Mode

1) Install the exhaust hose and window kit properly (see pages 7 & 8).
2) Plug the Power Cord into an electrical outlet.
3) Turn on the unit by pressing the POWER Button on the control panel.
4) Press the MODE button until the “ 🔍 ” appears on the control panel display.

NOTE: The unit operates at low fan speed during dehumidifier mode. The unit cools room slightly during while dehumidifying. Keep the windows and doors closed to aid the effectiveness of the unit as it removes moisture from the room.

NOTE: The unit will not perform in dehumidifier mode when the room temperature is lower than 61° F.

Fan Mode

1) Plug the Power Cord into an electrical outlet.
2) Turn on the unit by pressing the POWER button on the control panel.
3) Press the MODE button until the “ ” icon appears on the control panel display.
4) Select the fan speed by pressing the FAN button.
5) To circulate more air, press the SWING button on the remote control. (The louvers will oscillate up and down)

SoleusAir PH5-13R-35S - Fan Mode - 1

NOTE: It is not necessary for the exhaust hose and window kit to be installed to operate the unit in fan mode.

Auto Mode

1) Install the exhaust hose and window kit properly (see pages 7 & 8).
2) Plug the Power Cord into an electrical outlet.
3) Turn on the unit by pressing the POWER button on the control panel.
4) Press the MODE button until the “√” icon appears on the control panel display. Select the fan speed by pressing the FAN button.

SoleusAir PH5-13R-35S - Auto Mode - 1

NOTE: During AUTO mode, the unit operates in Dehumidifier mode when the room temperature is between

68°F to 80°F . And Air Conditioner mode when the room temperature is above 80°F . Heating Mode when the room temperature is below 68°F .

Sleep Mode (This mode can only be selected when using the Remote control)

1) To set Sleep mode, make sure the unit is in Air Conditioner mode or Heating mode.
2) Press the SLEEP Button on the remote control. The “ ” icon appears on the control panel display.
3) When in SLEEP mode, the fan will run on low to keep fan noise at a minimum.
4) When in Air Conditioner mode, the temperature setting will gradually increase to 2° F above the original set temperature for 6 hours. After 6 hours the temperature setting will return to the set temperature.
5) When in Heating mode, the temperature setting will gradually decrease to 2° F below the original set temperature for 6 hours. After 6 hours, the temperature setting will return to the set temperature.
6) When in Dehumidifier mode, the temperature will not change when Sleep mode is selected.

Compressor Indicator

SoleusAir PH5-13R-35S - Compressor Indicator - 1

SoleusAir PH5-13R-35S - Compressor Indicator - 2

The “” icon will light up on the control panel display when the compressor turns on. The “” icon will turn off when the compressor shuts off.

Emergency Condensate Holding Tank

When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut

off and the “☐” will appear on the control panel display. To empty the condensate tank, pull the drain plug at the bottom back of the unit. You will need a small pan, approximately 1" high to catch the water coming out of the condensate tank. Connect the supplied drainage hose to the back of the unit to aid in drainage into the pan. Once the condensate tank is drained, the unit will begin working within a few minutes. The emergency condensate tank is approximately 1.5 Liters of water. Another option is to purchase a small hose from a hardware store that can fit around the 5/8" drain plug on the back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage. It is not advised to use continuous drainage when the room temperature is higher than 90°F.

If you do not need the emergency tank emptied immediately simply leave the unit on. The fan in your air conditioner will continue to run to help evaporate the moisture as fast as possible. This will usually take around 60 minutes depending on how much water is in the tank.

* Remote color may differ from the image above.

REMOTE CONTROL OPERATING INSTRUCTIONS

1) Power On and Off - Press the POWER (I/O) button once to manually turn the unit on. Press the Power button once more to turn the unit off. When you press the POWER button the upper right square on the remote control LED Display will light up. When in Air Conditioner and Auto mode, the selected temperature will appear on the remote control display. When the unit is in Fan mode and Dehumidifier mode you will see the “- -” icon instead of the set temperature. This shows that temperature selection is not available when the unit is in Fan or Dehumidifier mode.
2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto, Air Conditioner, Dehumidifier, Fan only, and Heater mode. The upper left square on the Remote control display will light up showing which mode is selected. In Air Conditioner mode the display will show "COOL", in Heating mode the display will show "HEAT", in Dehumidifier mode the display will show "DRY", in Fan mode the display will show "FAN", and in Auto mode the display will show "AUTO".
3) Fan Speed - Press the FAN speed button to cycle through high, medium, and low fan speeds. The display on the remote control will show HIGH, MED, & LOW under the “SPEED” label on the remote control LCD display. There is an additional auto speed setting that is enabled in only heating and cooling modes. This speed is next setting after low when pressing the FAN speed button on the remote control. The speeds will cycle through in this order: High, Medium, Low, Auto. Each change in speed will be associated with a “beep” sound from the unit. The remote control will not display “AUTO” under the speed label. Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on the remote control.
4) Temperature Setting - When the unit is in Air Conditioner or Heating mode you can select your desired temperature. Press the ▲ or ▼ to select your desired temperature setting. The temperature on the LCD display on the remote control will increase or decrease accordingly. Pressing the ▼ and ▲ buttons simultaneously will change the temperature select between °F and °C.
5) SLEEP MODE - See "SLEEP MODE" on page 12.
6) SWING - To turn on oscillation, press the SWING button on the remote control. Once you press SWING button, the louvers on the unit will oscillate up and down “↑”. To change the horizontal direction of the air flow manually adjust the internal horizontal louvers left or right. Once SWING is selected the “←→” icon will show up on the LCD display on the remote control.
7) CLOCK - To set the clock on the remote control, hold down either the MIN or HOUR button until the displayed time flashes on the remote control display. Change the minutes by pressing the MIN button and change the hours by pressing the HOUR button. Set the clock prior to programming the timer.
8) TIMER - After setting the clock, you are ready to program the timer. program the timer, first press the T-ON button when the unit is off. Once T-ON is pressed the auto-on timer will blink in the bottom right rectangle of the remote control display. Press the MIN and HOUR buttons to change the clock to the desired time for the unit to automatically turn on. The minutes will increase by 10 with each press of the MIN button and the hours will increase by 1 with each press of the HOUR button. Press the T-OFF button when the unit is on to set the off timer. The remote control display will flash the desired auto-off timer. Press the MIN and HOUR buttons to change the clock to the desired time for the unit to automatically turn off. The timer is set when the auto-off time stops flashing and the words "ON" and "OFF" are displayed next to the time.

MAINTENANCE

Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit.

Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed.

1) Remove the filter from the filter compartment on the front and back of the unit.
2) Wash the air filter by immersing it gently into warm water with a neutral detergent. Rinse the filter and dry it thoroughly out of sunlight.
3) Slide the filter back into the filter compartment after it is thoroughly dried.
4) If the filter is torn or unusable, order a new filter by calling the customer service number on the warranty page of this manual.

Clean the unit Housing

1) Keep the unit from being exposed directly to the sun to prevent color fading.
2) Clean the surface with a damp cloth and dry it with a soft towel.

Storing the Unit for an Extended Period of Time or Transporting the unit

1) Empty any excess water by unplugging the water drainage stop in the back of the unit (located at the bottom).
2) Unplug the unit.
3) The unit should be stored in a cool dry place.

DISCLAIMER

ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER'S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.

WARRANTY

One Year Limited Warranty

Soleus International Inc. warrants the accompanying Soleus Air PH5 Series Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States.

If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of charge within a reasonable time after the unit is returned during the warranty period.

As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a copy of the original purchase invoice.

THIS WARRANTY DOES NOT COVER:

  • Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in material or workmanship.
  • Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions in the instructions.
  • Damage to the finish of the case, or other appearance parts caused by wear.
  • Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc.
  • Freight and Insurance cost for the warranty service.

ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY ARE LIMITED TO ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS INTERNATIONAL INC. DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC'S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.

This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, salvaged, or refurbished products.

As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For Technical Support & Warranty Service

Please Call (888) 876-5387

Or Write To:

Soleus International Inc.

20035 E. Walnut Dr. N.

City of Industry, CA 91789 USA

www.soleusair.com

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : SoleusAir

Model : PH5-13R-35S

Category : Air conditioner