Product Type Ultrasonic Low Fogger
Brand Froggy's Fog
Model Poseidon A2
Dimensions (Machine) 29 x 15.4 x 17.7 in
Net Weight 71 lbs
Gross Weight 80 lbs
Power Input 100-120 V, 50/60 Hz
Total Power Consumption 1700 W
Heat-Up Time 4.0 min
Fog Fluid Tank Capacity 0.8 Gal
Water Chamber Capacity 6 Gal
Maximum Continuous Duration Unlimited (with continuous water supply)
Control Methods On-device LCD, DMX-512 (3- and 5-pin XLR)
DMX Channels 3 (Fog, Fan, Humidity)
Adjustable Output Volume 1-100%
Adjustable Fan Speed 1-100%
Humidity Settings Off, Low, High
Auto Water Refill Yes
Low Water Protection Yes
No-Fluid Protection Yes (software-based sensor)
Included Accessories Ducting hose (3.3 m, 125 mm diam.), power cord, water refill hose, user manual
Maintenance Frequency Every 40 hours: flush with distilled water
Warranty 2-year limited (US only)

Frequently Asked Questions - Poseidon A2 Froggy's Fog

What type of fluid should I use with the Poseidon A2?
Use only Froggy's Fog approved fog fluids. Do not add flammable liquids. Water-based scent additives are allowed.
How do I connect the machine to a DMX controller?
Use a 3-pin or 5-pin DMX cable from the controller's output to the machine's DMX input. Set the starting address (1-512) via the LCD menu.
Why is the machine not producing fog?
Check if the machine is heated up (standby page shows 'Let's Get Low'). Ensure fog fluid and water are filled. The fluid sensor may trigger no-fluid protection; refill and clear warning.
How do I clean the machine?
After every 40 hours of use, run distilled water through the fog fluid system for 10-15 minutes. Then drain all water and refill with fresh fog fluid. Clean exterior with a damp cloth.
Can I mount the Poseidon A2 overhead?
No, for safety reasons the machine should only be operated on the ground. Do not mount it overhead.
What does the 'Water Level Low' warning mean?
The water chamber is low. The machine can run for about 10 more minutes. Add water via the top fill inlet or open the lid. Stop fog output before opening the lid.
How do I reset the circuit breaker?
Unplug the machine, let it cool for 15 minutes, then press the reset button on the breaker. Reconnect power.
What is the maximum ambient temperature for operation?
The maximum ambient temperature (Ta) is 104°F (40°C). Do not operate in higher temperatures.
Can I use the machine with a dimmer or rheostat?
No, never connect the machine to a dimmer pack or rheostat. Always use a grounded circuit with a breaker.
How should I store the machine when not in use?
Clean the system as per maintenance instructions. Drain all water from the chambers. Keep fog fluid in the pump mechanism. Store in a dry, cool place.

User questions about Poseidon A2 Froggy's Fog

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Effects machine in PDF format for free! Find your manual Poseidon A2 - Froggy's Fog and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Poseidon A2 by Froggy's Fog.

USER MANUAL Poseidon A2 Froggy's Fog

Froggy's Fog Poseidon A2 - 1

natural_image Line drawing of a modular industrial machine with wheels and ventilation slots (no text or symbols)

Froggy's Fog Poseidon A2 - 2

POSEIDON A2 ULTRASONIC LOW FOGGER

BEFORE YOU BEGIN....1

1.1 WHAT IS INCLUDED....1

1.2 UNPACKING INSTRUCTIONS .... 1

1.3 SYMBOLS....1

1.4 DISCLAIMER....1

1.5 SAFETY NOTES 1

1.5.1 PERSONAL SAFETY....1

1.5.2 MOUNTING AND RIGGING....2

1.5.3 POWER AND WIRING 2

1.5.4 OPERATION....2

2 INTRODUCTION....3

2.1 DESCRIPTION .... 3

2.2 FEATURES....3

2.3 PRODUCT OVERVIEW 3

3 TECHNICAL SPECIFICATIONS 3

4 SETUP....4

4.1 AC POWER....4

4.2 AC PLUG....4

4.3 RESETTING THE BREAKER....5

4.4 DMX LINKING 5

4.5 MOUNTING....5

4.5.1 ORIENTATION 5

4.5.2 RIGGING 5

5 OPERATION....5

5.1 PREPARING FOR OPERATION 5

5.2 ON-DEVICE CONTROL PANEL 5

5.3 ON-DEVICE CONTROL MODE & OPERATION 6

5.3.1 PROGRAMMING....6

5.3.2 MENU MAP....6

5.4 DMX MODE & OPERATION....8

5.4.1 STARTING ADDRESS 8

5.4.2 DMX MODE MENU MAP 8

5.4.3 DMX CHANNEL ASSIGNMENTS AND VALUES 8

5.5 AUTO RUN LAST SETTINGS....8

5.6 FLUID SENSOR....9

5.6.1 TRIGGER "NO-FLUID PROTECTION" 9

5.6.2 CLEAR "NO-FLUID PROTECTION" WARNING....9

5.7 LOW WATER PROTECTION....9

6 TECHNICAL INFORMATION....9

6.1 A WORD ON HUMIDITY....9

6.2 MAINTENANCE....9

6.3 STORAGE....10

6.3.1 MACHINE STORAGE 10

7 WARRANTY....10

BEFORE YOU BEGIN

1.1 What Is Included

• FFM-POSEIDON-AQUA2 Machine
• Ducting Hose (Length 3.3m, diameter 125mm)
- Power Cord
• Water Refill Hose Extension
- User Manual

1.2 Unpacking Instructions

Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition. If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier or dealer/seller immediately. In addition, keep the box and contents for inspection.

1.3 Symbols

Froggy's Fog Poseidon A2 - Symbols - 1

1.4 Disclaimer

The information and specifications contained in this User Manual are subject to change without notice. Froggys Fog assumes no responsibility or liability for any errors or omissions and reserves the right to revise or to create this manual at any time.

Copyright © 2019 Froggys Fog. All rights reserved.

1.5 Safety Notes

Please read the following Safety Notes carefully before working with the product. The notes include important safety information about installation, usage, and maintenance.

1.5.1 Personal Safety

• Always connect the product to a grounded circuit to avoid the risk of electrocution.
• During heating up and operation, the housing will be scalding hot. Do not touch.
- Condensation may form on the bottom of the product, creating damp or wet conditions under and around the machine. Use caution! Surfaces around the product may become slippery.
- The product is very hot during operation and it remains hot for a long time after operation has stopped. Do not touch the product's nozzle.
• Make sure that children, unauthorised people and animals do not obtain access to the machine.

- Never drink fog liquid. If it is ingested, call a doctor immediately for any discomfort. If liquid comes in contact with skin or eyes, rinse thoroughly with water.

1.5.2 Mounting and Rigging

• For safety reasons, we do not recommend mounting the product in any capacity. Operate the product while it is on the ground only.
• To prevent risk of fire or shock, do not expose the product to rain or moisture.
- CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow product to fully acclimate to the surrounding environment before connecting it to power.
• Do not mount the product on a flammable surface (linoleum, carpet, wood, paper, carton, plastic, etc.).
- Do not use in a confined space. Always install the product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
- Be sure that no ventilation slots on the product’s housing are blocked.

1.5.3 Power and Wiring

  • Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product.
    • Make sure the power cord is not crimped or damaged.
    • Never connect this product to a dimmer pack or rheostat.
  • Never disconnect the product from power cord by pulling or tugging on the cord.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it

1.5.4 Operation

  • Do not operate this product if you see damage to the housing or cables. Have the damaged parts replaced by an authorized technician at once.
    • Make sure there are no flammable materials close to this product while it is operating.
  • Do not cover or plug the output nozzle during operation.
    • Never carry the product by the power cord or any moving part. Always use the handles.
  • Drain the tank before transporting the product.
    • The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate the product at higher temperatures.
    • Always disconnect the product from the power source before cleaning.
  • This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained, certified technicians. Do not open the housing or attempt any repairs which can lead to damage or malfunction.
    • In the event of a serious operating problem, stop using the product immediately.
    • Using Only Froggys Fog approved fluids will ensure optimal performance and longevity.
  • Only specifically designed water based scent additives may be added to the fog fluid. Never add flammable liquids of any kind (oil, gas, non-application specific perfumes). Pay attention to all warning labels and instructions printed on the exterior of your machine.

Froggy's Fog Poseidon A2 - Operation - 1

Keep this User Manual for future use.

2 INTRODUCTION

2.1 Description

FFM-POSEIDON-AQUA2 Water-Fog Machine creates a continuous and low-lying fog that hugs the floor and dissipates without rising. By using the ultrasonic technology, need for dry ice or refrigeration is eliminated. Its environmentally friendly, economical, convenient and space saving. The Aqua 2 perfectly suited for small clubs, stage productions, rental companies or production release conferences.

2.2 Features

• Long-lasting body design with lightweight and rugged molded plastic chassis
- Integrated in a flight case (with castors), applicable for touring
• Drain holes design for both water tank and fluid tank, free from leakage
• Advanced No-Fluid protection, Auto Water Refill
- Locking power plug
• Built-in LCD control, 3pin and 5pin DMX control

2.3 Product Overview

Fog Fluid Tank 3 and 5 Pin DMX IN/OUT LCD Control Display Water Drain Upper Water Reservoir Locking Power Connector Circuit Breaker IP65 Power Switch Water Auto Refill Connection

3 TECHNICAL SPECIFICATIONS

AC PowerInput Voltage & Rate100-120 V, 50/60 Hz
Current Limiter Type (Heater)Breaker
Current Limiter Specifications (Heater)15 A, 250 V
Total Power Consumption1700 W
HeatingHeat Up Time4.0 min
AtomizersTotal Power Consumption500 W
Unit Quantity2 units
Power Consumption of each Unit250 W
Adjustable
Adjustment RangeOFF/50%/100%
CapacityFog Fluid Tank Capacity0.8 Gal
Water Chamber Capacity6 Gal
OutputAdjustable Volume
Volume Adjustment Level/Range1-100
Fog Fluid Consumption @ full volume25.0 mL/min
Water Consumption @ full volume240.0 mL/min
Maximum Continuous Duration @ full volumeUnlimited
Continuous Output
Max Continuous Output Level100%
Fully-loaded Cumulative Output Duration @ full volume~60 min
FeaturesPhysical Thermostat
Electronic Thermo-Control
Adjustable Output
Adjustable Fan Speed
Auto Water Refill
Low Water Protection
No-Fluid Protection
ControlOn-device Manual ControlLCD control board
Wireless ControlN/A
Wired ControlDMX
Control ProtocolDMX-512
DMX Channel Range3
Data Connectors3- and 5-pin XLR
AccessoryDucting Hose1 pc, Length 3 m, Diameter 100mm (4 inch)
Flat Diffuser NozzleOptional
Fan Inlet Rain Cover
Weight & DimensionsNet Weight71 lbs
Gross Weight80 lbs
Machine Dimensions29 / 15.4 / 17.7 in
Packing Dimensions34 / 18.1 / 20 in

4

SETUP

4.1 AC Power

Froggy's Fog Poseidon A2 - AC Power - 1

Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.

Froggy's Fog Poseidon A2 - AC Power - 2

Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

4.2 AC Plug

The FFM-POSEIDON-AQUA2 comes terminated with a lockable power connector on one end. It is designed to be safely connected and disconnected under live load.

4.3 Resetting the Breaker

This product is equipped with a resettable external breaker for the fog heater core. If the breaker trips, all sections of this product will lose power.

  • Remove the power cord from mains power.
  • Allow unit to cool for 15 minutes.
    • After 15 minutes, you may attempt to reset the breaker by pressing the button with your finger.
  • Plug the product's power cords into the power outlet and continue using as recommended.

4.4 DMX Linking

You can link the FFM-POSEIDON-AQUA2 to a DMX controller using a 3- or 5-pin DMX connection. If using other DMX-compatible products with this product, you can control each individually with a single DMX controller. Instructions for connecting and configuring this product for DMX operation are described further on Pg. 9.

4.5 Mounting

Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.

4.5.1 Orientation

For safety reasons, we do not recommend mounting the product in any capacity. Operate the product while it is on the ground only, and make sure there is adequate room for ventilation, configuration, and maintenance.

4.5.2 Rigging

FROGGYS FOG recommends using the following general guidelines when mounting this product.

  • Before deciding on a location for the product, make sure there is easy access to the product for maintenance and programming purposes.
  • Make sure that the structure or surface onto which you are mounting the product can support the product's weight (see the Technical Specifications).
  • When installing the product on the floor, make sure that the product and cables do not pose a tripping hazard.

5 OPERATION

5.1 Preparing for Operation

• After checking that all the parts are intact and complete, position the machine on flat and level surface.
• Fill the water into water chamber with the power off to mitigate electrical risk.
• Always connect the product to a grounded circuit. Before powering on, make sure the unit is connected with the rated voltage.
- Turn on the machine, it will immediately start heating up.

5.2 On-device Control Panel

To access the control panel functions, use the four buttons located underneath the LCD display.

MENU TIMER VOLUME STOP

ButtonFunction
MENUSwitch menu pages to select a function
▲/▲ Increases the numeric value of current functionTIMER starts the timer-controlled operation
▼/▼ Decreases the numeric value of current functionVOLUME triggers the pump to modify the output volume
STOPEnter enables the currently displayed menu or sets the currently selected value into the selected functionSTOP turns the fog output off

5.3 On-device Control Mode & Operation

5.3.1 Programming

• Refer to the Menu Map to understand the menu options. The menu map shows the main level and a variable number of programming levels for each option.
- To go to the desired main level, press

repeatedly until the option shows on the display. This will take you to the first programming level for that option.
- To select an option or value within the current programming level, press ▲/ or ▼/ until the option shows on the display. If there is another programming level, you will see that first option, or you will see the selected value.
- Press repeatedly to switch menu pages.
- Press to go back to Standby Page.

5.3.2 Menu Map

DisplayDescriptionParameter Range
Starting PagesPoseidon Aqua 2 Version XX
Poseidon Aqua 2 AC-120V 60Hz
Preparing PageHeating Up >>>>>>>>>The machine is heating up.
Standby PageLet's Get Low Poseidon Aqua 2Finished heating up, ready to work.
Working Status PagesInterval 600s Poseidon Aqua 2Interval countdown of TIMER mode
Setting PagesDuration 300s Poseidon Aqua 2Duration countdown of TIMER mode
Fog Output 100% Fan Speed 100%Output status of VOLUME mode
Fog Output 100%Press ▲ or ▼ to set fog output of VOLUME mode1-100%
Fan Speed 100%Press ▲ or ▼ to set fan speed of VOLUME mode1-100%
Humidity 100%Press ▲ or ▼ to set output humidity of VOLUME modeOFF/Low/High
Timer Interval 600sPress ▲ or ▼ to set timer interval of TIMER mode5-600s
Timer Duration 300sPress ▲ or ▼ to set timer duration of TIMER mode5-300s
Timer Fog Output 100%Press ▲ or ▼ to set fog output of TIMER mode1%-100%
Timer Fan Speed 100%Press ▲ or ▼ to set fan speed of TIMER mode1%-100%
Timer Humidity 100%Press ▲ or ▼ to set output humidity of TIMER modeOFF/Low/High
DMX Address 512Press ▲ or ▼ to select DMX starting address1-512
Fluid Sensor ONPress ▲ or ▼ to activate/deactivate fluid sensor to turn on/off no-fluid-protection functionON/OFF
Auto Run Last Settings YESPress ▲ or ▼ to set if the machine will automatically run previous setting when power on againYES/NO
Keypad Tone OffPress ▲ or ▼ to turn on/off Keypad SoundON/OFF
Error & Warning PagesWater Level Low Refill WaterFog Fluid Low Refill
Heating Failure Contact Service

5.4 DMX Mode & Operation

The Machine FFM-POSEIDON-AQUA2 works with a DMX controller.

  • Connect the product to a suitable power outlet.
  • Turn the product on.
  • Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product.

5.4.1 Starting Address

When selecting a starting DMX address, always consider the number of DMX channels. If you choose a starting address that is too high, you could restrict the access to some of the product's channels.

Froggy's Fog Poseidon A2 - Starting Address - 1

FROGGYS FOG® FFM-POSEIDON-AQUA2 DMX set the starting address in the 001 - 512 DMX range and uses 3 DMX channels, which defines the highest configurable address to 510 to have all channels controllable.

Froggy's Fog Poseidon A2 - Starting Address - 2

Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product, or press repeatedly “MENU” button until the LCD shows “DMX Address”. Press “▲” or “▼” to set desired DMX starting

5.4.2 DMX Mode Menu Map

When connected with DMX controller and receiving a DMX signal, the display will always show current DMX starting address. You may adjust the starting channel anytime by pressing ▲ and ▼.

DMX Address 512

5.4.3 DMX Channel Assignments and Values

ChannelFunctionValueDescription
1Fog0 -10No Function
11 - 2551-100%
2Fan0 -10No Function
11 - 2551-100%
3Humidity0 -10No Function
11 -12750% Humidity
128-255100% Humidity

5.5 Auto Run Last Settings

If the machine is shut off while it is operating in standalone mode (On-device & Wireless control), the “Auto Run Last Setting” will allow the machine to recover its previous same operating status when the unit is powered on again without pressing any buttons.

Froggy's Fog Poseidon A2 - Auto Run Last Settings - 1

  • Shut off: Get disconnected from power source, or turn off the power switch
    • Power on: Get connected with power source, or turn on the power switch

5.6 Fluid Sensor

This machine uses a software-based fluid sensor to detect whether there is fluid inside the tube so as to protect the pump from being damaged. Turn on the “Fluid Sensor” to activate “No Fluid Protection” function.

Fluid Sensor ON

5.6.1 Trigger "No-Fluid Protection"

When the Fluid Sensor is ON, the software-based “no-fluid protection” function will be activated. After the program continues to detect the machine working with no fluid inside the tube for 1 minute, the pump-shutoff will be activated with the flickering warning page showing on the screen.

Fog Fluid Low Refill

When this warning message is displayed, the machine will stop working but the LCD warning will continue.

5.6.2 Clear "No-Fluid Protection" Warning

When the machine is under the no-fluid protection, after refilling the fluid, there are three ways to clear the warning.

  • Press first, then press ▼/ to let the machine run again, the warning will disappear once fluid has pumped and filled the tube.
    • Under the DMX control mode, bring down channel 1 to OFF (value 0-9), then back to ON (value 10-255), to let the machine run again. The warning will disappear once fluid has pumped and filled the tube.

- Turn off "Fluid Sensor" in the menu.

The LCD will keep flickering whenever it shows the warning message or regular operation menu pages until the fluid is sensed by software.

5.7 Low Water Protection

When the water in the chamber is low, the LCD will flicker and show the warning message as below:

Water Level Low Refill Water

After the warning message shows up, the machine can still run for another 10 minutes with the remaining water in the lower chamber, but will then stop output. Adding water in the upper chamber by either opening the lid on, or through the water fill inlet at the top of the machine.

Froggy's Fog Poseidon A2 - Low Water Protection - 1

Fog output should be stopped when opening the water chamber lid to avoid fog from coming out in the event of an empty water reservoir.

6 TECHNICAL INFORMATION

6.1 A Word on Humidity

Froggy's Fog Poseidon A2 - A Word on Humidity - 1

Make sure to adjust the humidity levels on a per show basis. The more humidity injected into the fog, the longer the ground fog effect will last, delaying the rising of the fog. This comes at the cost of higher moisture content in the fog, which can become a concern when regarding smooth floor surfaces and foot traffic. Attentiveness is advised.

6.2 Maintenance

After every 40 hours of continuous operation, use Distilled water through the fog fluid system and fog 10-15 minutes after finish heating-up to prevent the accumulation of particulate matter in the heating element.

The recommended cleaning procedure is as follows.

1) Unplug the product from power.

2) Empty all fog fluid from the tank.
3) Add distilled water to the fog fluid tank.
4) Connect the product to power and allow it to heat up.
5) Run the product in a well-ventilated area for 10-15 minutes. Do not allow the pump to run dry.
6) After fog operation with solely distilled water, drain the water from the fog fluid reservoir and fill with fresh fog fluid and run additional for a few minutes. The machine is best stored with fresh fog fluid in the pump mechanism.
7) Empty the water reservoirs through drain outlet. These should be stored dry.
8) Excessive dust, fluid residue and dirt will degrade performance and cause overheating. Remove dust from air vents with an air compressor, vacuum or soft brush. The casing should be cleaned with the damp cloth.

Froggy's Fog Poseidon A2 - Maintenance - 1

Test-run your FROGGYS FOG® FFM-POSEIDON-AQUA2 on a monthly basis to achieve the best performance.

6.3 Storage

6.3.1 Machine Storage

Before storing the machine, clean it as described in the cleaning procedure above. Do not store the machine long term with water in the system. Verify that fog fluid resides in the pump mechanism before storing the machine. Cleaning the system prior to storage will help prevent any particles from condensing inside the pump or heater while not in use.

7 WARRANTY

Save these instructions. 2 Year Limited Warranty: Valid from the date of purchase. Warranty covers manufacturing defects only and does not cover misuse or abuse of the machine. Serial number, place of purchase with dated valid receipt must be submitted at time of service. Warranty is only valid with-in the United States. Buyer may be responsible for shipping fees associated with repairs.