| Product Type | Ground Fog Machine |
| Model | FFM-TITAN-ICE |
| Brand | Froggy's Fog |
| Dimensions (Machine) | 31 x 15.4 x 17.7 in |
| Weight (Net) | 71 lbs |
| Power Input | 100-120 V, 50/60 Hz |
| Total Power Consumption | 1600 W |
| Heat-Up Time | 4.0 min |
| Fog Fluid Tank Capacity | 0.8 Gal |
| Ice Tray Capacity | 20 lbs |
| Fog Fluid Consumption (full volume) | 25.0 mL/min |
| Ice Consumption (full volume) | 20 lbs/hr |
| Output Volume Adjustment | 1-100% |
| Fan Speed Adjustment | 1-100% |
| Control Methods | On-device LCD, Wireless (RF 433 MHz), DMX-512 (2 channels) |
| Wireless Remote | W-4 with A27 battery, range RF 433 MHz |
| DMX Connectors | 3-pin and 5-pin XLR |
| No-Fluid Protection | Software-based fluid sensor, automatic pump shutoff |
| Auto Run Last Settings | Yes, recovers previous standalone mode settings after power cycle |
| Safety Features | Locking power plug, resettable circuit breaker, overheat protection |
| Mounting | Ground operation only; not recommended for rigging |
| Warranty | 2-Year Limited Warranty (manufacturing defects, US only) |
| Recommended Fluid | Froggy's Fog low-lying fog fluid only; no flammable additives |
| Maintenance Interval | Every 40 hours: flush with distilled water; clean air vents monthly |
| Storage | Drain water, leave fluid in pump; store in dry place |
Frequently Asked Questions - Titan Ice Froggy's Fog
User questions about Titan Ice Froggy's Fog
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Effects machine in PDF format for free! Find your manual Titan Ice - Froggy's Fog and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Titan Ice by Froggy's Fog.
USER MANUAL Titan Ice Froggy's Fog

TITAN
ICE

natural_image
Line drawing of a modular industrial machine with wheels and mounting brackets (no text or symbols)BEFORE YOU BEGIN....1
1.1 WHAT IS INCLUDED....1
1.2 UNPACKING INSTRUCTIONS .... 1
1.3 SYMBOLS....1
1.4 DISCLAIMER....1
1.5 SAFETY NOTES....1
1.5.1 PERSONAL SAFETY 1
1.5.2 MOUNTING AND RIGGING 2
1.5.3 POWER AND WIRING 2
1.5.4 OPERATION....2
2 INTRODUCTION....3
2.1 DESCRIPTION....3
2.2 FEATURES....3
2.3 PRODUCT OVERVIEW 3
3 TECHNICAL SPECIFICATIONS....4
4 SETUP....4
4.1 AC POWER....4
4.2 AC PLUG....4
4.3 RESETTING THE BREAKER 4
4.4 DMX LINKING 5
4.5 MOUNTING 5
4.5.1 ORIENTATION 5
4.5.2 RIGGING 5
5 OPERATION....5
5.1 COOLING WITH ICE 5
5.2 PREPARING FOR OPERATION....5
5.3 ON-DEVICE CONTROL PANEL 5
5.4 ON-DEVICE CONTROL MODE & OPERATION....6
5.4.1 PROGRAMMING 6
5.4.2 MENU MAP 6
5.5 WIRELESS REMOTE-CONTROL MODE & OPERATION....8
5.6 DMX MODE & OPERATION....8
5.6.1 STARTING ADDRESS....9
5.6.2 DMX MODE MENU MAP 9
5.6.3 DMX CHANNEL ASSIGNMENTS AND VALUES 9
5.7 AUTO RUN LAST SETTINGS....9
5.8 FLUID SENSOR....9
5.8.1 TRIGGER "NO-FLUID PROTECTION" 9
5.8.2 CLEAR "NO-FLUID PROTECTION" WARNING 9
6 TECHNICAL INFORMATION 10
6.1 MAINTENANCE 10
6.2 STORAGE....10
6.2.1 MACHINE STORAGE....10
7 WARRANTY....10
BEFORE YOU BEGIN
1.1 What Is Included
- FFM-TITAN-ICE Machine
- Power Cord
• W-4 Remote Wireless Controller with A27 battery - User Manual
1.2 Unpacking Instructions
Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition. If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier or dealer/seller immediately. In addition, keep the box and contents for inspection.
1.3 Symbols
| Symbol | Meaning |
![]() | CautionCritical installation, configuration, or operation information. Not following these instructions may make the product not work, cause damage to the product, or cause harm to the operator. |
![]() | ImportantImportant installation or configuration information. Failure to comply with this information may keep the product from working correctly. |
![]() | InformationUseful information. |
1.4 Disclaimer
The information and specifications contained in this User Manual are subject to change without notice. Froggys Fog assumes no responsibility or liability for any errors or omissions and reserves the right to revise or to create this manual at any time.
Copyright © 2019 Froggys Fog. All rights reserved.
1.5 Safety Notes
Please read the following Safety Notes carefully before working with the product. The notes include important safety information about installation, usage, and maintenance.
1.5.1 Personal Safety
• Always connect the product to a grounded circuit to avoid the risk of electrocution.
• During heating up and operation, the housing will be scalding hot. Do not touch.
- Condensation may form on the bottom of the product, creating damp or wet conditions under and around the machine. Use caution! Surfaces around the product may become slippery.
- The product is very hot during operation and it remains hot for a long time after operation has stopped. Do not touch the product's nozzle.
• Make sure that children, unauthorised people and animals do not obtain access to the machine.
- Never drink fog liquid. If it is ingested, call a doctor immediately for any discomfort. If liquid comes in contact with skin or eyes, rinse thoroughly with water.
1.5.2 Mounting and Rigging
• For safety reasons, we do not recommend mounting the product in any capacity. Operate the product while it is on the ground only.
• To prevent risk of fire or shock, do not expose the product to rain or moisture.
- CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow product to fully acclimate to the surrounding environment before connecting it to power.
• Do not mount the product on a flammable surface (linoleum, carpet, wood, paper, carton, plastic, etc.).
- Do not use in a confined space. Always install the product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
- Be sure that no ventilation slots on the product’s housing are blocked.
1.5.3 Power and Wiring
- Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product.
• Make sure the power cord is not crimped or damaged. - Never connect this product to a dimmer pack or rheostat.
• Never disconnect the product from power cord by pulling or tugging on the cord. - To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it
1.5.4 Operation
- Do not operate this product if you see damage to the housing or cables. Have the damaged parts replaced by an authorized technician at once.
• Make sure there are no flammable materials close to this product while it is operating. - Do not cover or plug the output nozzle during operation.
• Never carry the product by the power cord or any moving part. Always use the handles. - Drain the melted ice reservoir before transporting the product.
• The maximum ambient temperature is 104\ °F ( 40\ °C ). Do not operate the product at higher temperatures.
• Always disconnect the product from the power source before cleaning. - This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained, certified technicians. Do not open the housing or attempt any repairs which can lead to damage or malfunction.
• In the event of a serious operating problem, stop using the product immediately.
• Using Only Froggys Fog approved fluids will ensure optimal performance and longevity. - Only specifically designed water based scent additives may be added to the fog fluid. Never add flammable liquids of any kind (oil, gas, non-application specific perfumes). Pay attention to all warning labels and instructions printed on the exterior of your machine.

Keep this User Manual for future use.
2 INTRODUCTION
2.1 Description
FFM-TITAN-ICE Ground Fog Machine creates a continuous and low-lying fog that hugs the floor and dissipates without rising. Its environmentally friendly, economical, and convenient for creating a constant cloud of fog. The Titan Ice is perfectly suited for small clubs, stage productions, outdoor scenes and events.
2.2 Features
• Long-lasting body design with lightweight and rugged molded plastic chassis
- Integrated in a flight case (with castors), applicable for touring
• Advanced No-Fluid protection
- Locking power plug
• Built-in LCD control, 3pin and 5pin DMX control
• Digital Timer Controls
- Wireless On/Off Control
2.3 Product Overview

3 TECHNICAL SPECIFICATIONS
| AC Power | Input Voltage & Rate | 100-120 V, 50/60 Hz |
| Current Limiter Type (Heater) | Breaker | |
| Current Limiter Specifications (Heater) | 15 A, 250 V | |
| Total Power Consumption | 1600 W | |
| Heating | Heat Up Time | 4.0 min |
| Capacity | Fog Fluid Tank Capacity | 0.8 Gal |
| Ice Tray Capacity | 20 lbs | |
| Output | Adjustable Volume | √ |
| Volume Adjustment Level/Range | 1-100% | |
| Fog Fluid Consumption @ full volume | 25.0 mL/min | |
| Ice Consumption @ full volume | 20 lbs/ Hr | |
| Continuous Output | √ | |
| Max Continuous Output Level | 100% | |
| Electronic Thermo-Control | √ | |
| Adjustable Output | √ | |
| Adjustable Fan Speed | √ | |
| No-Fluid Protection | √ | |
| Control | On-device Manual Control | LCD control board |
| Wireless Control | W-4 / RF 433MHz / Built-in | |
| Wired Control | DMX | |
| Control Protocol | DMX-512 | |
| DMX Channel Range | 2 | |
| Data Connectors | 3- and 5-pin XLR | |
| Weight & Dimensions | Net Weight | 71 lbs |
| Gross Weight | 80 lbs | |
| Machine Dimensions | 31 / 15.4 / 17.7 in | |
| Packing Dimensions | 34 / 18.1 / 20 in |
4
SETUP
4.1 AC Power

Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.

Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
4.2 AC Plug
The FFM-TITAN-ICE comes terminated with a lockable power connector on one end. It is designed to be safely connected and disconnected under live load.
4.3 Resetting the Breaker
This product is equipped with a resettable external breaker for the fog heater core. If the breaker trips, all sections of this product will lose power.
- Remove the power cord from mains power.
- Allow unit to cool for 15 minutes.
• After 15 minutes, you may attempt to reset the breaker by pressing the button with your finger.
- Plug the product's power cords into the power outlet and continue using as recommended.
4.4 DMX Linking
You can link the FFM-TITAN-ICE to a DMX controller using a 3- or 5-pin DMX connection. If using other DMX-compatible products with this product, you can control each individually with a single DMX controller. Instructions for connecting and configuring this product for DMX operation are described further on Pg. 9.
4.5 Mounting
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.
4.5.1 Orientation
For safety reasons, we do not recommend mounting the product in any capacity. Operate the product while it is on the ground only, and make sure there is adequate room for ventilation, configuration, and maintenance.
4.5.2 Rigging
FROGGYS FOG recommends using the following general guidelines when mounting this product.
- Before deciding on a location for the product, make sure there is easy access to the product for maintenance and programming purposes.
- Make sure that the structure or surface onto which you are mounting the product can support the product's weight, including consumables (see the Technical Specifications).
- When installing the product on the floor, make sure that the product and cables do not pose a tripping hazard.
5 OPERATION
5.1 Cooling with Ice
The machine achieves low ground fog by chilling hot fog down to temperatures below the ambient air temperature. This creates a low ground fog effect until the fog reaches ambient air temperature and starts to rise. Proper ground fog formulas are designed to dissipate once the fog reaches ambient air temperature.
5.2 Preparing for Operation
• After checking that all the parts are intact and complete, position the machine on flat and level surface.
• Always connect the product to a grounded circuit. Before powering on, make sure the unit is connected with the rated voltage.
- Turn on the machine, it will immediately start heating up.
• Fill the Fog Fluid Tank with high quality fog fluid designed for low fog applications.
• Fill the Ice Tray with ice while still allowing room for the lid to fully close and seal.
5.3 On-device Control Panel
To access the control panel functions, use the four buttons located underneath the LCD display.

| Button | Function |
| MENU | Switch menu pages to select a function |
| ▲/ | ▲ Increases the numeric value of current functionTIMER starts the timer-controlled operation |
| ▼/ | ▼ Decreases the numeric value of current functionVOLUME triggers the pump to modify the output volume |
| STOP | Enter enables the currently displayed menu or sets the currently selected value into the selected functionSTOP turns the fog output off |
5.4 On-device Control Mode & Operation
5.4.1 Programming
• Refer to the Menu Map to understand the menu options. The menu map shows the main level and a variable number of programming levels for each option.
- To go to the desired main level, press