PB 200N - Scale PCE Instruments - Free user manual and instructions
Find the device manual for free PB 200N PCE Instruments in PDF.
| Product Type | Platform scale |
| Model | PCE-PB 200N |
| Weighing Range | 200 kg / 440 lb |
| Resolution | 0.1 kg / 3.5 oz |
| Accuracy | ±0.3 kg / 10.5 oz |
| Minimum Load | 0.3 kg / 10.5 oz |
| Units | kg, lb, oz/lb |
| Platform Dimensions | 350 x 390 x 40 mm |
| Display Dimensions | 180 x 88 x 33 mm |
| Weight | Approximately 3 kg / 6.6 lb |
| Power Supply | 4 x 1.5 V AA batteries or 6 V DC mains adaptor (included) |
| Operating Temperature | 5 to 35 °C |
| Humidity | < 85% RH, non-condensing |
| Auto Power Off | Yes, selectable (5 min or off) |
| Tare Function | Yes, press key once |
| Piece Counting | Yes, with sample sizes 25, 50, 75, 100 |
| Calibration | Yes, with 10, 20, or 50 kg weight |
| Overrange Indication | "0_Ld" |
| Low Voltage Indication | "LO" |
| Delivery Scope | Scale, 4 batteries, mains adaptor, wall bracket, manual |
| Maintenance | Clean with damp cloth and pH-neutral cleaner |
| Safety | Do not exceed range, avoid shocks, use only as specified |
Frequently Asked Questions - PB 200N PCE Instruments
User questions about PB 200N PCE Instruments
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Scale in PDF format for free! Find your manual PB 200N - PCE Instruments and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PB 200N by PCE Instruments.
USER MANUAL PB 200N PCE Instruments
User Manual
PCE-PB 75N / PCE-PB 200N Platform Scales

User manuals in various languages (français, italiano, español, português, nederlands, türk, polski, русский, 中文) can be found by using our product search on: www.pce-instruments.com
Last change: 30 August 2021
v1.0
Contents
1 Safety notes....1
2 Specifications.... 2
3 Delivery scope....2
4 First use 2
4.1 On / off 2
4.2 Automatic power off.... 3
5 Change unit .... 3
6 Set zero point .... 3
6.1 Automatic zeroing .... 3
6.2 Internal zero point .... 3
6.3 Tare 3
7 Piece counting....4
8 Calibration .... 4
9 Contact....5
10 Disposal 5
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
- The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
- The instrument may only be used if the environmental conditions (temperature, relative humidity, ...) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
- Do not expose the device to shocks or strong vibrations.
- The case should only be opened by qualified PCE Instruments personnel.
- Never use the instrument when your hands are wet.
- You must not make any technical changes to the device.
- The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
• The device must only be used with accessories from PCE Instruments or equivalent.
- Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
- Do not use the instrument in explosive atmospheres.
- The measurement range as stated in the specifications must not be exceeded under any circumstances.
- Non-observance of the safety notes can cause damage to the device and injuries to the user.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of business.
If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.
2 Specifications
| PCE-PB 75N | |
| Weighing range | 75 kg / 165 lb |
| Resolution | 0.02 kg / 0.7 oz |
| Accuracy | ±0.06 kg / 2.1 oz |
| Minimum load | 0.06 kg / 2.1 oz |
| PCE-PB 200N | |
| Weighing range | 200 kg / 440 lb |
| Resolution | 0.1 kg / 3.5 oz |
| Accuracy | ±0.3 kg / 10.5 oz |
| Minimum load | 0.3 kg / 10.5 oz |
| Further specifications | |
| Units | kg, lb, oz/lb |
| Overrange indication | "0_Ld" |
| Low voltage indication | "LO" |
| Operating conditions | 5 ... 35 °C / 41 ... 95 °F<85 % RH, non-condensing |
| Power supply battery | 4 x 1.5 V AA battery |
| Power supply mains adaptor | primary: 100 ... 240 VAC, 50/60 Hz, 0.3 A secondary: 6 VDC, 1 A |
| Platform dimensions | 350 x 390 x 40 mm / 13.7 x 15.3 x 1.5" |
| Display dimensions | 180 x 88 x 33 mm / 7.0 x 3.4 x 1.3" |
| Weight | approx. 3 kg / 6.6 lb |
3 Delivery scope
1 x platform scales PCE-PB 75N or PCE-PB 200N
4 x 1.5 V AA battery
1 x 6 V mains adaptor
1 x wall mounting bracket
1 x user manual
4 First use
Before the balance is used, it should acclimatise for one hour. Failure to do so may result in incorrect readings. To switch on the balance, insert four AA 1.5 V batteries on the back of the display and/or use the 6 V plug-in mains adaptor included in the delivery scope. If the supply voltage is too low, the display will show "LO". Further use is not possible. Therefore, check the batteries and/or the mains adaptor.
4.1 On / off
To switch on the balance, press and release the key once. The display shows the following in sequence:
- All icons
- Version number
- Maximum measurement range
- Measurement mode
Once the balance is in measurement mode, you can use it.
To turn off the balance, press the play again.
4.2 Automatic power off
To save battery power, the instrument has an auto power off feature. To set this function, press and hold the key until the display shows "5" for a shutdown after five minutes of inactivity or "-" to disable the auto power off function. You can now use the key to select one of these two options. Press the key to confirm your selection. You will return to measurement mode. IMPORTANT: This function is always deactivated during mains operation.
5 Change unit
To change the unit, press and release the key once. You can choose either kg, lb or oz/lb.
6 Set zero point
There are several ways to set the zero point. These are described in the following chapters. Important: Always note that the maximum measurement range must not be exceeded.
6.1 Automatic zeroing
After turning on the scales, the displayed reading is automatically zeroed. To disable this function, press and hold the play until "AUtO Zo" appears on the display when the balance is switched on. You can now use the key to select "ON" or "OFF" to enable or disable this function. Press the key button to confirm the selection. You will return to measurement mode.
6.2 Internal zero point
With the platform scales, for example, a zero point can be set for a container weighing without having to carry out an adjustment. This has the advantage that the container is subtracted during the measurement. To do this, first place the container on the weighing surface. Then press and hold the 🔊 key while the balance is switched on until you reach the menu for automatic zeroing. First switch off this function. Now press the 🔊 key. "SET Zo" appears on the display. Now change this function from "OFF" to "ON" by pressing the key. Confirm the entry with the key. You will return to measurement mode.
Important: Each time this function is activated again, permanent zeroing is performed. Resetting to "OFF" will not remove the new zero.
6.3 Tare
To tare the displayed weight, press and release the key once in measurement mode.
7 Piece counting
To perform a piece count of the weight, first place the following number of test pieces on the weighing platform. You can choose between 25, 50, 75 and 100 pieces. Then press and hold the
key until "PCS" flashes on the display. You can now use the key to select between the
numbers of test pieces on the weighing platform. Now press the "Key to accept the selection. If "Pass" appears on the display, the execution was correct and the balance starts with the piece counting directly. If "Err" appears on the display, the operation was not correct. Repeat the procedure.
To exit the piece counting mode, press the key. Press and release the key to return to piece counting.
Important: No individual number is possible.
8 Calibration
To perform a calibration, press and hold the key until the display shows the maximum measurement range of the balance. A selection of calibration weights is then displayed. You can choose between 10, 20 and 50kg . To do this, press the key. Then press the key. The calibration is now performed. Only now place the reference weight on the scales. If the calibration was successful, the display will show "PASS". If the measured value is not stable or if you cancel the calibration prematurely, "ERR" is shown on the display. To cancel the calibration prematurely, press and hold the key.
9 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
10 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.


PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L.
Im Langel 4 23, rue de Strasbourg Calle Mayor, 53
D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete)
Unit 11 Southpoint Business Park
Ensign Way, Southampton
Hampshire
United Kingdom, SO31 4RF
Tel: +44 (0) 2380 98703 0
Fax: +44 (0) 2380 98703 9
info@pce-instruments.co.uk
www.pce-instruments.com/english
Italy
PCE Italia s.r.l.
Via Pesciatina 878 / B-Interno 6
55010 Loc. Gragnano Pehlivan Sok. No.6/C
Capannori (Lucca)
Italia
www.pce-instruments.com/turkish
The Netherlands
PCE Brookhuis B.V.
Institutenweg 15
7521 PH Enschede
Nederland
Telefoon: +31 (0)53 737 01 92
info@pcebenelux.nl
www.pce-instruments.com/dutch
info@pce-americas.com
United States of America
PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter / Palm Beach
33458 FL
USA
Tel: +1 (561) 320-9162
Fax: +1 (561) 320-9176