KADEHUM6LFA - Dehumidifier Kogan - Free user manual and instructions
Find the device manual for free KADEHUM6LFA Kogan in PDF.
| Product Type | Dehumidifier |
| Brand | Kogan |
| Model | KADEHUM6LFA |
| Dehumidifying Capacity (30°C, 80% RH) | 6 L/day |
| Dehumidifying Capacity (27°C, 60% RH) | 3 L/day |
| Power Supply | AC 220-240V ~ 50Hz |
| Rated Input Power | 180 W |
| Rated Input Current | 1.1 A |
| Water Tank Capacity | 2.1 L |
| Net Weight | 7 kg |
| Dimensions (H x L x W) | 406.5 mm x 270 mm x 205 mm |
| Application Temperature Range | 5 °C to 32 °C |
| Refrigerant Type & Charge | R290 / 25 g |
| Fuse Rating | 3.15 A / 250 VAC |
| Operating Modes | Continuous, Drying |
| Humidity Setting Range | 30% – 80% (5% increments) or forced operation (C0) |
| Timer Function | Yes |
| Filter Cleaning Interval | Every 2 weeks |
| Continuous Drainage Capability | Yes (via drain hose) |
| Auto Defrost | Yes (below 18 °C) |
| Safety Features | Automatic shut-off when tank full; overheat protection; child lock not specified; manual warnings against blocking vents, using near flammables, or operating with damaged cord. |
| Spare Parts / Repairability | Power cord replacement by qualified service; filter replaceable; no user-serviceable internal parts. |
| User Manual Included | Yes (available online) |
Frequently Asked Questions - KADEHUM6LFA Kogan
User questions about KADEHUM6LFA Kogan
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Dehumidifier in PDF format for free! Find your manual KADEHUM6LFA - Kogan and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. KADEHUM6LFA by Kogan.
USER MANUAL KADEHUM6LFA Kogan
natural_image
White plastic electronic device with perforated panel and transparent lid (no visible text or symbols)6L DEHUMIDIFIER
KADEHUM6LFA
Safety & Warnings 3
Overview 6
Installation 8
Before First Use 9
Operation 11
Cleaning & Care 12
Specifications 14
Troubleshooting 15
Notes 17
SAFETY & WARNINGS
![]() | ![]() | Read all instructions carefully before operating your dehumidifier. The warnings and the cautions stated in “Precautions” must be observed for safe operation. |
![]() | Warning | This means improper handling may result in a death or a serious injury to a person. |
![]() | Cautions | This means improper handling may result in an injury or damage to properties. |
- In case of any abnormality be sure to turn off the dehumidifier, disconnect the plug, cease use immediately and contact help.Kogan.com for support.
- Never attempt to turn off the dehumidifier by disconnecting the plug.
- Never modify the dehumidifier. Do not attempt to disassemble or service the unit by yourself.
- Always keep your hands dry while plugging into or pulling off the plug to avoid electric shock.
- Ensure only AC220-240V power is connected to this equipment.
- Remove any dust from the pins of the power plug and insert the plug into an outlet securely.
- To avoid the risk of fire or explosion, do not spray any chemicals or aerosols onto the dehumidifier. Do not place any inflammables or chemicals near the unit.
- To prevent parts from melting or catching on fire, do not place the dehumidifier near heating appliances.
- The power cord must not be damaged or modified. Do not put any hot or heavy objects on the cord. Do not pull it out or bundle it during operation.
- To avoid damages to the power cord, do not pinch the cord in a door.
- This unit contains a fan running at high speed, never insert rods or objects into the openings of the dehumidifier.
![]() | Remove water that has been collected in the tank.(Accidentally drinking of the water or using it for other purpose may cause illness and /or unforeseen accidents.) |
![]() | Risk of electric shock. Disconnect power before servicing unit Moving parts. do not operate unit with back cover removed. Hot parts. Do not operate unit with back cover removed. |
WARNING: Do not use means to accelerate the defrosting process or to clean, other than those recommended by Kogan.com. The appliance must be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater. Do not pierce or burn. Be aware that refrigerants may not contain an odour. The maximum refrigerant charge amount: 30g/45g
Warning
- The appliance must be installed in accordance with national wiring regulations.
- If the power cord is damaged, it must be replaced by Kogan.com, its service agent or similarly qualified persons in order to avoid a hazard.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involves.
- Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- The dehumidifier must be used on a level and stable surface.
- To prevent the water from freezing do not use the dehumidifier and the drain hose at ambient temperature below 0^ C.
- Do not use the dehumidifier outside. Exposure to direct sunlight or rain may result in overheating, electric shock and fire.
- Do not place a water vessel on the dehumidifier (if water gets into the unit it may cause deterioration of the insulation.)
-
Never attempt to use the dehumidifier for special uses, such as food or preservation of art objects or the like.
-
Never attempt to use the dehumidifier for special uses, such as food or preservation of art objects or the like.
- Do not use the unit in locations exposed to chemicals.
- For continuous draining, ensure that the drain hose is set properly without a rising slope.
- Be careful that a heating appliance is not exposed to the air expelled from the dehumidifier.
- Do not use the dehumidifier as a chair or a footstool.
- For safety purpose, disconnect the power plug if the unit is not use for an extended period.
- In case of using the dehumidifier in a wardrobe, be sure to prevent children from getting in the closet.
- Do not remove the float lever from the water tank.
- To avoid damages to the power cord, do not pull on the cord when moving the unit.
- Do not block the air intakes and the air outlets. Do not cover the unit with clothing.
- Prior to continuous operation for a long duration, safety checks are required especially for the air filter, the drain hose etc.
- Turn off the unit and disconnect the power plug before starting any cleaning or other routine maintenance.
- To avoid the risk of electric shock never sprinkle or spill water on the dehumidifier when cleaning.
- Turn off the unit and empty the water out of the water tank when moving the unit. Be sure to hold the handle when moving.
OVERVIEW
Front

Back

Control panel

INSTALLATION
The following space must be maintained to ensure the operating efficiency of the dehumidifier.

Note:
If the dehumidifier gets interference from other household appliances, such as television and radio cassette player, keep the equipment is at least 70cm away from the dehumidifier.
BEFORE FIRST USE
Defrosting
The evaporator in the dehumidifier may defrost automatically if it is operated in a room with a temperature less than 18^ C. Defrosting may start and operate for approximately 5 minutes every 25 minutes or even longer.
- During the defrosting operation, the dehumidification function and air purification function may suspend.
- Do not turn off the switch or pull out the power plug of the dehumidifier during the defrosting operation.
This dehumidifier is not intended to function as an air conditioner set to extreme low temperatures. The purpose of this dehumidifier is to remove high humidity from rooms. It can't be used lower the temperature.
Room temperature during the operation
This dehumidifier doesn't have cooling function. It will produce heat during operation and increase the room temperature by up to 1 - 4°C. This temperature rise may be more noticeable in smaller spaces.
Dehumidifying capacity
The diagram below shows the daily dehumidifying capacity of the dehumidifier. This capacity is based on a 30^ C room temperature, 80% of relative humidity and the data when the air outlet is fully open. At different temperatures and relative humidity, it may have different dehumidifying capacities.
In the same room temperature, the dehumidifying capacity is higher in higher relative humidity and the dehumidifying capacity is lower in lower relative humidity. In the same relative humidity, the dehumidifying capacity is higher in higher temperature and the dehumidifying capacity is lower in lower temperature.
If the dehumidifier is placed in the cabinet, its dehumidifying capacity may greatly reduce in a short period after operating.

line
| Room temperature | Dehumidifying capacity | | ---------------- | ---------------------- | | 5 | 2 | | 30 | 10 |Water tank
- Confirm the tank is correctly installed in position. The dehumidifier can't operate if the water in the tank is full or isn't installed well.
- Hold the water tank and slide it outwards.

natural_image
Diagram of a device with a mesh chamber and open door, showing hands interacting with the interior (no text or symbols)
natural_image
Diagram of a device with a mesh chamber and hand gestures, showing internal components without any text or symbols.Emptying the water tank
- Pull out the water tank from the dehumidifier.
- Tip the water tank upside down and empty out the water slowly.
- Install the water tank back into the dehumidifier.
Note:
After the dehumidification, the water tank may contain water. When the water tank is full, the full indicator will turn on.

natural_image
Technical line drawing of a mechanical component with internal channels and a curved housing (no text or symbols)OPERATION
Power button:
Press to turn the dehumidifier on/off.
“+” and “-” buttons:
Humidity can be set (humidity adjustment is only effective in continuous mode), the setting range is 30%-80% (5% adjustment coefficient)-C0 (forced operation), the above setting cycle is adjustable and the digital tube flashes for 5 seconds when setting and it will automatically exit the setting state if there is no operation within 5 seconds. set timer under timer mode.
Dehumidification Mode:
Press the mode button to select continuous mode or drying mode and confirm with a delay of 5 seconds when switching modes.
CLEANING & CARE
Warning
- Please don't plug in with wet hands to avoid electric shock.
- Please cut off the power supply before daily cleaning and maintenance.
- Don't dismantle the floater from the water tank.
- Always place the dehumidifier unit upright to avoid incorrect operation and unusual noises.
- If dehumidifier is not in use for extended periods:
o Empty out the water in the tank wipe up the water tank and install it back.
- Clean the filter.
- Place the machine unit upright and avoid the direct sunlight.
Machine body
- Wipe up the dehumidifier with a damp cloth (put it into the water and wring it out).
- Do not clean the control unit with wet cloth.
- Never clean the dehumidifier unit with gasoline, thinner or liquid detergent to avoid deformation of the unit.

natural_image
Line drawing of a portable air conditioner unit with a hand holding the top part (no text or symbols)Clean the filter (every 2 weeks)

natural_image
Illustration of a device with a grid-patterned lid being handled, showing hand positioning and structural change (no text or symbols)The dehumidify capacity may reduce when the filter net is clogged with defilement.
The dust collector is always used to clean the dust. If the filter net is too dirty, it can be cleaned with.
Continuous drainage
When you are not at home but require long-term operation, you can use the continuous drainage feature.
Insert the drain pipe into the drain outlet on the rear of the unit.

natural_image
Line drawing of a portable air conditioner unit with a fan and hose (no text or symbols)SPECIFICATIONS
| Power supply | AC220V-240V~50Hz |
| Dehumidifying capacity | 6L/day (30°C 80%)3 L/day (27°C 60%) |
| Rated input power 180W | |
| Rated input current | 1.1A |
| Water tank capacity 2.1L | |
| Net weight 7kg | |
| Overall dimensions | Height 406.5mm, length 270mm, width 205mm |
| Application scope 5-32°C | |
| Refrigerant | R290/25g |
| Fuse 3.15A/250VAC |
The parameters above may change with the improvement of the machine unit without further notice. Refer to the nameplate for details.
TROUBLESHOOTING
Check cause below first before contacting help.Kogan.com for support.
| Problem | Possible causes | Solutions |
| Unit not working | Check whether the power cord is connected. | Plug in the power cord. |
| The water lank is full. | Empty out the water in it. | |
| Check the water tank is in position. | Install the water tank correctly. | |
| Reduced dehumidifying capacity | The filter is too dirty. Clean the filler. | |
| The air inlet and outlet are blocked. | Remove the blockage or move the dehumidifier to ensure better air flow. | |
| The unit is emitting loud noises | Check the unit is placed well. | Place the unit on a flat and stable floor. |
| The dehumidifying process stopped | The room temperature is too high or too low and out of the operating range of the dehumidifier. | The dehumidifier may resume automaticity when the room temperature returns to the working range. |
| The clothing isn’t drying fast. | The room temperature is too low. | The wet clothing may dry more slowly in low temperatures. |
Supplementary Issues
| Issue Causes | |
| Unit stops during the operation It is defrosting | |
| Reduced dehumidifying capacity The dehumidifying capacity drops with the room temperature and humidity. | |
| The humidity of the room will not reduce The room area is too big and outside the operating range. The door and windows of the room aren’t closed. Other appliances in the room may be impacting the effectiveness of the unit. | |
| The machine unit emits a sound during operation. | The sound made by the flowing of the refrigerant. This is normal and may eliminate or lower automatically while the system operates stably. |
| The product arrived with water in the tank. Since each unit gets operation testes before leaving the factory, some water remains on the evaporator flows to the water tank. | |
| The FULL indicator light is on. | When the water tank is full, the FULL indicator light will turn on. |

This marking indicates that this appliance should not be disposed with other household wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.
NOTES
Need more information?
We hope that this user guide has given you the assistance needed for a simple set-up.
For the most up-to-date guide for your product, as well as any additional assistance you may require, head online to help.kogan.com
kogan.com





