Product TypeBluetooth Smart Temperature Controller
BrandInkbird
ModelITC-312
Power Input120Vac, 60Hz, 10A Max
Power Output120Vac, 60Hz, 10A, 1200W total (two receptacles)
Temperature Control Range-40°F to 212°F / -40°C to 100°C
Temperature Measurement Error±2.0°F / 1.0°C
BluetoothBLE 5.0
Bluetooth Range100 meters in open area
Temperature Probe Length6.56 ft (2 m)
Probe Waterproof RatingIP67
Control ModesGeneral temperature mode, Day/Night mode, Time mode
Setting MethodsTemperature range mode or Temperature return differential mode
Data Storage (Device)30 days of temperature history
Data Storage (App)Up to 1 year of temperature data
AlarmsHigh and low temperature alarms with adjustable settings and sound on/off
Refrigeration DelayAdjustable delay time between cooling cycles
Temperature CalibrationAdjustable from -4.9°C to 4.9°C / -9.9°F to 9.9°F
DisplayLED screen with current temperature, target temperature, and status icons
Control InterfaceRotary knob with push button
App CompatibilityiOS 12.0+ and Android 7.1+ via INKBIRD app
CleaningWipe with dry cloth; do not use water or wet cloth
Usage EnvironmentIndoor, dry place only
Safety CertificationsFCC Part 15, IC RSS
Warranty2 years against defects in components or workmanship

Frequently Asked Questions - ITC-312 Inkbird

How do I connect the ITC-312 to the INKBIRD app?
Open the INKBIRD app, tap '+' in the top right corner, and follow the in-app instructions. Ensure Bluetooth is enabled on your smartphone and the device is in connecting mode (short press the rotary knob if needed). The device must be as close to your phone as possible during connection.
What should I do if the display shows '1E'?
The '1E' error indicates the clock needs synchronization. Log into the INKBIRD app and connect the controller to sync the clock. This may occur after first use or if the controller has been unplugged for more than 10 days.
How do I calibrate the temperature probe?
Enter the setting mode, navigate to 'CA' (Calibration), and adjust the value between -4.9°C and 4.9°C (-9.9°F to 9.9°F) to match a known accurate thermometer. Clean the probe before calibration for best results.
How can I turn off the high/low temperature alarm sound?
On the device: enter setting mode, select 'AS' (Alarm sound), and set to OFF. Via the app: go to Settings > Device > Device Alarm Sound and toggle OFF.
What is the maximum load for the outlets?
Each outlet is rated for 120Vac, 60Hz, 10A, with a total combined power of 1200W (120Vac). Do not exceed these ratings to avoid fire hazards.
Why is my temperature probe reading incorrect?
Clean the stainless steel part of the probe with a dry cloth. If moisture is suspected, use a hairdryer to dry the probe completely (device unplugged). Also check that the probe is not damaged.
Can I set different temperatures for day and night?
Yes, select 'Day/Night Mode' in the app. You can set two target temperature ranges: one for day and one for night, each with its own heating and cooling setpoints.
How do I set the refrigeration delay?
During initial app setup or later via the app settings, you can set a refrigeration delay (in minutes) to prevent the cooling device from restarting too quickly after being switched off. This helps protect the compressor.
What should I do if the screen freezes or the controller is unresponsive?
Unplug the controller and plug it back in to reboot. If the problem persists, contact Inkbird customer support.
How do I test the heating and cooling outputs?
Unplug the controller, connect a heating/cooling device (within rated power), press and hold the SET button while plugging in, release SET. Then turn the knob left for heating symbol (output on) or right for cooling symbol to test each output.

User questions about ITC-312 Inkbird

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual ITC-312 - Inkbird and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ITC-312 by Inkbird.

USER MANUAL ITC-312 Inkbird

natural_image Simple line drawing of a light bulb with radiating lines (no text or symbols)

Warm tips

  • To quickly jump to a specific chapter page, click on the relevant text on the contents page.
  • You can also use the thumbnail or document outline in the top left corner to quickly find a specific page.

CONTENTS

Overview 04

Technical Specifications 05

Product Diagram 06

Operation Instructions 08

APP Installation & Connection 13

Cleaning and Maintenance 26

Important Notes/Warnings 26

Troubleshooting Guide 27

FCC Requirement 29

IC Warning 31

Customer Service 32

QR code image containing encoded data, no visible human-readable text

Please keep this manual properly for reference. You can also scan the QR code to visit our official website for product usage videos. For any usage issues, please feel free to contact us at support@inkbird.com.

Inkbird ITC-312 - CONTENTS - 2

Overview

The ITC-312 Bluetooth Smart Temperature Controller has three control functions--general temperature mode, day/night mode, and time mode, and supports two setting methods--range method and return differential method, making it more flexible to use. Users can choose the setting method according to their usage habits. At the same time, it supports a Bluetooth function, which enables app operation, which is more convenient. The device can store 30 days of temperature history and the phone app can store up to 1 year of temperature data. It also has high and low-temperature alarm functions and is an intelligent controller that is widely used for heating, cultivation, seedling growing, wood sheds, home living, and more.

Inkbird ITC-312 - Overview - 1

Technical Specifications

BrandINKBIRD
ModelITC-312
Input120Vac, 60Hz, 10A Max
Output120Vac,60Hz,10A,1200W(total two receptacles)Max
Temperature Control Range-40°F~212°F/-40°C~100°C
Temperature Measurement Error±2.0°F/1.0°C
Bluetooth FunctionBLE 5.0
Bluetooth Distance100 meters in an open area

NOTE:

For the first use or after unplugging the controller for more than 10 days (when is displayed on the device), please login to the INKBIRD app to connect the controller to have it synchronize the clock and work regularly.

Inkbird ITC-312 - NOTE: - 1

Product Diagram

INKBIRD 1 2 3 4 5

1 White Light LED

-8.00 °C -8.00 °F -8.00 (°)

-888 °C -888 °F Current Temperature and Unit Target Temperature °C °F Temperature Unit Heating Symbol Cooling Symbol (●●) Bluetooth Symbol

2 Rotary Button

ButtonFunction
Rotary ButtonPress and hold it for 2 seconds to enter or exit setting; in the setting state, short press to select the setting menu; in the non-setting state, short press to authorize Bluetooth connection; rotate up or down to adjust the parameter.

3 Output Port (HEATING & COOLING)
4 Temperature Probe(Length: 6.56ft (2m), IP67 Waterproof)
5 Input Power Cord

04 Operation Instructions

4.1 Setting Guideline

Select the device setting method through the App: Temperature range setting mode or Temperature return difference setting mode.

Temperature range setting mode: Separately set start and stop temperatures for heating and cooling devices. (Recommended)

Temperature return difference setting mode: Set the target temperature and the return difference value of heating and cooling temperatures. (Select this method if you are more accustomed to the setting logic of the ITC-308.)

4.2 Running Mode Guideline

Select the device operating mode through the App: Temperature mode (default), Day/Night mode, or Time mode.

Temperature Mode: Power on or off the plug-in devices according to the current temperature and target temperature.

Day/Night Mode: 2 target temperatures can be set in a day, and the controller will perform different temperature controls according to the 2 preset control periods.

Time Mode: Up to 12 target temperatures can be set in a day, and the controller will perform different temperature controls according to the preset time periods.

4.3 Description of the Menu Characters

Character Function DefaultRange
CFTemperature unit switchC or FF
RHHigh-temperature alarm-40.0°C~100°C50°C
-40.0°F~212°F122°F
ALLow-temperature alarm-40.0°C~100°C0°C
-40.0°F~212°F32°F
rd0 minuteRefrigeratio
CATemperature calibration-4.9°C~4.9°C0.0°C
-9.9°F~9.9°F0.0°F
ASAlarm soundON or OFF ON

4.4 How To Quick Set Target Temperature

4.4.1 Temperature Range Setting Mode

Press the knob button to enter the quick setting of target temperature. The screen will display the character SH and the start heating temperature, with the latter flashing. Turn the knob button to adjust the parameter, then press the knob button to confirm and switch to the setting of end heating temperature (EH), start cooling temperature (SC) and end cooling temperature (EC). If there is no operation within 10 seconds, the device will automatically exit quick setting, or, when EC is displayed, press the knob button again to exit the setting.

Character Function DefaultRange
SHStart heating temperature-40.0°C~100°C23.0°C
-40.0°F~212°F74.0°F
EHEnd heating temperature-40.0°C~100°C25.0°C
-40.0°F~212°F77.0°F
SCStart cooling temperature-40.0°C~100°C27.0°C
-40.0°F~212°F80.0°F
ECEnd cooling temperature-40.0°C~100°C25.0°C
-40.0°F~212°F77.0°F

4.4.2 Temperature Return Difference Setting Mode

Press the knob button to enter the quick setting of target temperature. The screen will display the character and the start heating temperature, with the latter flashing. Turn the knob button to adjust the parameter, then press the knob button to confirm and switch to the setting of heating differential value ( H_d ) and cooling differential value ( [d ). If there is no operation within 10 seconds, the device will automatically exit quick setting, or, when [d is displayed, press the knob button again to exit the setting.

Character Function DefaultRange
_t Target temperature-40.0°C~100°C25.0°C
-40.0°F~212°F77.0°F
_d Heating differential0.2°C~15.0°C2.0°C
0.3°F~25.0°F3.0°F
CdCooling differential0.2°C~15.0°C2.0°C
0.3°F~25.0°F3.0°F

NOTE:

  1. In timer mode and day/night mode, quick setting can only modify the target temperature for the current time.
  2. In timer mode, if the current time is not within the preset time range, where - - - is displayed, the quick setting is not available.

Inkbird ITC-312 - NOTE: - 1

APP Installation & Connection

Inkbird ITC-312 - APP Installation & Connection - 1

INKBIRD APP

QR code image with a central logo, likely linking to a digital resource or website.

5.1 Search the INKBIRD App from Google Play or App Store to get it for free, or you can scan the QR code to download it directly.

NOTE:

  1. Your iOS devices must be running iOS 12.0 or above to download the app smoothly.
  2. Your Android devices must be running android 7.1 or above to download the app smoothly.
  3. APP Location Permission Requirement: We need to obtain your location information to discover and add nearby devices. INKBIRD promises to keep your location information strictly confidential. And your location information will only be used for the location function of the App and will not be collected, used, or disclosed to any third party. Your privacy is very important to us. We will abide by relevant laws and regulations and take reasonable security measures to protect your information security.

5.2 Registration

Step1: Registering an account is necessary before using the INKBIRD app for the first time.
Step2: Open the app, select your Country/Region, and a verification code will be sent to you.
Step3: Enter the verification code to confirm your identity, and the registration is complete.

5.3 How to Connect

Open the INKBIRD app and click the "+" in the top right corner to add a device. Then follow the app's instructions to complete the connection. Please make sure to place the device as close to your smartphone as possible during the connection process.

5.4 Application Instructions

5.4.1 App Guideline

For the first time connecting the product, the App will guide the user through the following operation:

1 Select the setting method (Set temperature range or Set temperature return difference)
2 Set the temperature unit
3 Select the running mode of the device (Temp Mode, Day/Night Mode, or Time Mode)
4 Set the temperatures
5 Set the high and low-temperature alarms
6 Set the refrigeration delay.

9:41 Select Setting Method Set Temp. Range Set the world and state temperature was appropriately for the meeting and meeting attention. Recognised to use Set Temp. Differential If you are familiar with the setting method of the ITC-205, you can select this method Skip the instructions Next step (1/6)

1 Select the setting method (Set temperature range or Set temperature return difference)

9:41 Set Temp. Unit Temp. Unit °C °F Skip the instructions Next step (2/0)

② Set the temperature unit

9:41 Select Working Mode Temp. Mode Prior the temperature in the home climate Day/Night Mode Set different temperature ranges for day and night Time Mode Set multiple from night times with more than temperature ranges. Skip the instructions Next step (3/4)

3 Select the running mode of the device (Temp Mode, Day/Night Mode, or Time Mode)

Set Temperatures * Heating Temp. Range Start ② Stop ① 76.0 ° 77.0 ° * Cooling Temp. Range Start ② Stop ① 78.0 ° 77.0 ° Skip the instructions Next step (4%)

4 Set the temperatures

Set High/Low-temp Alarm High-temp Alarm 83° Low-temp Alarm 71° Skip the Instructions Next step (5/6)

5 Set the high and low-temperature alarms

Set Refrigeration Delay Refrigeration Delay Delay - 0 + The refrigeration delay time is the shortest time between the stop time and the next start time of the cooling device. For example, out it to 5 minutes. And, no matter how the temperature changes, the cooling device will not restart within 5 minutes after being switched off. Skip the Instructions Confirm

6 Set the refrigeration delay

5.4.2 Main Interface Introduction

Product model × ITC-312 116 °F Current Temp 40.0 °F 50.0 °F 10.0 °F 108 °F 16.0 °F Starting Voltage Starting Range 10.0 °F 108 °F 16.0 °F Starting Range Starting Range 10.0 °F 108 °F Starting Range Starting Range 10.0 °F 108 °F Settings Settings Settings page 98.2 °F Go to the Settings page Go to Set Temperatures Alarm records History records Settings Select Running Mode

5.4.3 Setting Interface Introduction

13:20 Settings Device High-temp Alarm Low-temp Alarm Temp. Calibration 0.3 > Refrigerations Delay 10 > Temp. Unit °C P Other > Follow the system

13:20 Settings Device Customize device name R4KBRDBDITC-312 Device Alarm Sound More Clear all data Remove the device

  • Go to the Settings page

Cancel Save Target Temp. 108 ° * Heating Differential 21.0 ° * Cooking Differential 18.0 °

Cancel Save * Heating Temp. Range Start ② Stop ① 76.0 ° 77.0 ° Cooling Temp. Range Start ② Stop ① 78.0 ° 77.0 °

0:41 ITC-312 116 °F Current Temp. + 10.0 °F Receiving Weatherline 108 °F Target Temp + 16.0 °F Counting Weatherline Temp. Mode Day Night Mode New Mode History Temp. Mode √ Knee Records

- Set the Temperatures Select Running Mode

Inkbird ITC-312 - Setting Interface Introduction - 6

Heating condition

Cooling condition

History records Alarm records

5.4.4 Introduction to the Temperature Range Main Interface and the Temperature Setting Pop-up Window

Temp Mode

0:41 X ITC-312 97.1° Current Temp Floating Range 92.5 °C 102 °C Cooling Range 138 °C 132 °C Settings Lost Morning Situations Monitor History Focus, Make > Alone Panels

841 X ITC-312 Heating is progress 10 sec 82.8° Heating Range 92.5° & 102° Sweep Range 100° & 100° Settings Last Running Situation

Heating/Cooling in progress and working time

- Main interface

Day/Night Mode

11:30 X ITC-312 98.7°F Current Status 45°C 20°C Floating Rides 92.5% 4p 102% Floating Hours 138% 6p 132% Day Mode 5000 L/min - 400 m/s Last Running Shadowers Heading History Disruptive Motion Alarm Records

  • Main interface
    Inkbird ITC-312 - Day/Night Mode - 2

11:00 Cancel Day Mode 109 AM Nighting Temp. Range Start 92.5°F Stop 102°F Cooling Temp. Range Start 138°F Stop 132°F Save Night Mode 100 PM Heating Temp. Range Start 92.5°F Stop 102°F Cooling Temp. Range Start 138°F Stop 132°F

  • Set the temperatures for Day/Night

Time Mode

11:44 X ITG-312 98.2°F Last and Next Hiding Mode 92.5 °F 102 °F Creating Mode 138 °F 132 °F 6 300 ms × 400 ms Edit Time Segments

  • Main interface

17:59 Cancel Save 2 Start Time End Time 2:00 4H → 9:00 4H * Heating Temp. Range Start Stop 76.0°F 77.0°F * Cooling Temp. Range Start Stop 78.0°F 77.0°F

Set the periodic temperatures

Rename the current time segment

Inkbird ITC-312 - Time Mode - 3

Cleaning and Maintenance

6.1 Please make sure to unplug the temperature controller before cleaning. If cleaning is necessary, use a dry, clean cloth to wipe it; do not clean with water or a wet cloth.
6.2 Do not place it where children can touch it. Store in a dry, ventilated place.

Inkbird ITC-312 - Cleaning and Maintenance - 1

Important Notes/Warnings

7.1 KEEP CHILDREN AWAY.
7.2 USE INDOORS ONLY TO REDUCE THE RISK OF ELECTRIC SHOCK.
7.3 DO NOT CONNECT TO OTHER RELOCATABLE POWER SOURCES OR EXTENSION CORDS.
7.4 USE IN A DRY PLACE ONLY.
7.5 DO NOT PLACE NEAR WATER TO REDUCE THE RISK OF ELECTRIC SHOCK.
7.6 DO NOT EXPOSE TO HIGH TEMPERATURES.
7.7 THE HOUSING OF THE TEMPERATURE PROBE IS MADE OF STAINLESS STEEL MATERIALS. WIPE OFF ANY STAINS TO AVOID AFFECTING THE ACCURACY OR RESPONSE TIME OF THE PROBE.
7.8 DO NOT CONNECT IT TO A PRODUCT THAT IS NOT RATED FOR ITS VOLTAGE, WHICH MAY CAUSE FIRE HAZARDS.

Inkbird ITC-312 - Important Notes/Warnings - 1

Troubleshooting Guide

Cannot connect Bluetooth?

  1. Check that your smartphone has Bluetooth enabled.
  2. Check that the device is in the connecting state.

Display 1E?

Please login to the INKBIRD app to connect the controller to have it synchronize the clock and work regularly.

Incorrect probe readings?

Wipe to clean the stainless steel part of the probe and blow with a hairdryer to completely evaporate the moisture inside the probe (making sure that the device is disconnected from the power supply).

Failure to switch on or off the heating/cooling output?

  1. Test the electric power:

A. Unplug the controller, and plug a heating or cooling device. (Note that the device voltage must not exceed the rated voltage of this product.)
B. Press and hold the SET button (until the Controller is turned on).
C. Connect the power supply to start up, then release the SET button.

D. Turn the knob button to the left, and the heating symbol will light up on the LED, indicating that the heating output is open. At this point, check that the unit is turned on. E. Turn the knob button to the right, and the cooling symbol will light up on the LED, indicating that the cooling output is open. At this point, check that the unit is turned on.

  1. Please check that the load power of the external device is within the rated power of this product, 1200W (120Vac) or 2200W (220Vac). If the above operational steps still do not resolve your issue, please contact our customer support team.

The screen of the controller gets stuck/frozen?

Unplug the controller and reboot it. If the problem persists, please contact Customer Support.

The controller will sound an alarm and AL/AH will flash on the screen. How to turn off the AL/AH alarm sound?

  1. Set through the device: Enter the setting mode, choose AS (Alarm sound) on the menu, and then select ON (turn on the alarm sound) or OFF (turn off the alarm sound).
  2. Set through the App: Enter the setting interface, select "Device", and then go to "Device Alarm Sound" to toggle ON or OFF.

Probe readings are changing repeatedly (sudden rise or fall)/Readings are changing very slowly?

Wipe to clean the stainless steel part of the probe and blow with a hairdryer to completely evaporate the moisture inside the probe (making sure that the device is disconnected from the power supply).

Outlet melted/burnt?

Please check that the load power of the external device is within the rated power of this product, 1200W (120Vac) or 2200W (220Vac), or contact Customer Support instead.

Deficient screen display / The screen keeps flashing / The sound of electricity is audible / Displaying Er / Displaying Err ?

Please contact Customer Support.

Inkbird ITC-312 - Deficient screen display / The screen keeps flashing / The sound of electricity is audible / Displaying Er / Displaying Err ? - 1

FCC Requirement

Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Inkbird ITC-312 - FCC Requirement - 1

IC Warning

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:

(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.

The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.

This item carries a 2-year warranty against defects in either components or workmanship. During this period, products that prove to be defective will, at the discretion of INKBIRD, be either repaired or replaced without charge. For any problems in use, please feel free to contact us at support@inkbird.com. We will do our best to help you.

Shenzhen Inkbird Technology Co., Ltd.

support@inkbird.com

Consignor: Shenzhen Inkbird Technology Co., Ltd.

Office Address: Room 1803, Guowei Building, No.68 Guowei Road, Xianhu Community, Liantang, Luohu District, Shenzhen, China

Manufacturer: Shenzhen Inkbird Technology Co., Ltd.

Factory Address: 6th Floor, Building 713, Pengji Liantang Industrial Area, No.2 Pengxing Road, Luohu District, Shenzhen, China

Inkbird ITC-312 - Shenzhen Inkbird Technology Co., Ltd. - 1

Inkbird ITC-312 - Shenzhen Inkbird Technology Co., Ltd. - 2

Inkbird ITC-312 - Shenzhen Inkbird Technology Co., Ltd. - 3

Inkbird ITC-312 - Shenzhen Inkbird Technology Co., Ltd. - 4

Inkbird ITC-312 - Shenzhen Inkbird Technology Co., Ltd. - 5

Inkbird ITC-312 - Shenzhen Inkbird Technology Co., Ltd. - 6

Inkbird ITC-312 - Shenzhen Inkbird Technology Co., Ltd. - 7

Inkbird ITC-312 - Shenzhen Inkbird Technology Co., Ltd. - 8

V2.0

MADE IN CHINA

DESIGNED BY INKBIRD

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Inkbird

Model : ITC-312

Category : Uncategorized