Product TypePressure Washer
BrandGerni
ModelClassic 100.5
Power SourceElectric (corded)
Voltage220-240 V
Frequency50/60 Hz
Power Consumption1.3 kW (typical)
Current6 A
Protection ClassClass I (with earth connection)
Max Water Inlet Pressure1 MPa / 10 bar
Max Water Inlet Temperature40°C
Nominal Pressure7 MPa / 70 bar
Maximum Pressure10 MPa / 100 bar
Flow Rate (nominal)5.3 l/min (320 l/h)
Kickback Force<20 N
Weight5.1 kg
Sound Pressure Level69.2 dB(A)
Sound Power Level (guaranteed)84 dB(A)
Vibration Level<2.5 m/s²
Safety FeaturesAuto shut-off (trigger stop), thermal protector, safety lock, pressure safety valve
Intended UseDomestic cleaning
Warranty2 years (domestic use)
Manual Pages7 (EN)

Frequently Asked Questions - Classic 100.5 Gerni

Why won't my pressure washer start?
Check if it's plugged in, try a different socket, replace any blown fuse, and ensure the extension cord is not defective. If the problem persists, consult the troubleshooting section.
What should I do if the pressure fluctuates?
Fluctuating pressure may be due to air in the pump or hose, an inadequate water supply, a partially blocked nozzle, a blocked water inlet filter, or a kinked hose. Allow the machine to run with the trigger open to expel air, ensure proper water flow, clean the nozzle and filter, and straighten hoses.
How do I clean the nozzle?
Use the cleaning needle or a thin wire to clear debris from the nozzle opening. Refer to the user guide (Part 2:3, G) for detailed instructions. Regular nozzle cleaning prevents pressure loss and pulsation.
Can I use any detergent with my Gerni pressure washer?
Use only cleaning agents supplied or recommended by Gerni. Other chemicals may affect safety and machine performance. Always follow detergent instructions for use, emergency, and disposal.
What precautions should I take during operation?
Wear safety boots, respiratory mask (FFP2 or equivalent), ear protection, goggles, and protective clothing. Hold the spray lance firmly with both hands due to kickback. Do not direct the jet at persons, live electrical equipment, or the machine itself.
How should I store the pressure washer after use?
Turn off the machine, disconnect from power and water, drain all water from machine and accessories to prevent frost damage. Wind up the cable and hose carefully. Store in a frost-free location.
What does the thermal protector do?
The automatic self-resetting thermal protector cuts power if the machine overheats. If triggered, wait for the machine to cool down before resuming use. This prevents damage from prolonged operation.
Why does my machine pulsate?
Pulsation is often caused by air in the inlet hose/pump, insufficient water supply, a partially blocked nozzle, a blocked water filter, or a kinked hose. Run the machine with the trigger open to purge air, ensure adequate water supply (min. 1/2" hose), and clean nozzle and filter.
Is it safe to use an extension cord?
Yes, but only if it is suitable for outdoor use and the connection is kept dry and off the ground. Use a cord reel that keeps the socket at least 60 mm above ground. Inadequate extension cords can be dangerous.
What is the warranty period and what does it cover?
Gerni offers a 2-year warranty for domestic use from the date of purchase. It covers defects in materials or workmanship, provided the product is used according to the manual, no unauthorized repairs, and only original accessories are used. Wear and tear, misuse, or commercial use are not covered.

User questions about Classic 100.5 Gerni

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Pressure washer in PDF format for free! Find your manual Classic 100.5 - Gerni and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Classic 100.5 by Gerni.

USER MANUAL Classic 100.5 Gerni

Unit 1/13 Bessemer Street | Blacktown NSW 2148 | Tel.: 1300 556 710

Part 1:3 Safety Instructions, High Pressure Washers, Classic, Classic PG, Super and Super PG

Safety Instructions Original Safety Instructions

Before first use of the machine, read the instructions carefully. Save instructions for later use.

Safety instructions marked with this symbol must be observed to prevent personal injury or serious damage to property.

- The instruction consists of 4 parts. Part 1:3 Safety Instructions. Part 2:3 Serial specifi c User Guide. Part 3:3 Troubleshooting, Serial specifi c Technical Data and Disposal. Part 1:4 Warranty Conditions.

Warnings ⚠️ This machine has been designed for use with cleaning agents supplied or recommended by Gerni. The use of other cleaning agents or chemicals may adversely affect the safety of the machine. High pressure jets can be dangerous if subject to misuse. The jet must not be directed at persons, live electrical equipment or the machine itself. Do not use the machine within range of persons unless they wear protective clothes.

Do not direct the jet against yourself or others in order to clean footwear. Risk of explosion – Do not spray flammable liquids. High pressure washers shall not be used by children or untrained personnel. High pressure hoses, fi ttings and couplings are important for the safety of the machine. Use only hoses, fi ttings and couplings recommended by Gerni. To ensure machine safety, use only original spare parts recommended by Gerni. Water that has flown through back-flow preventers is considered to be non-potable.

Don't use the machine if a supply cord or important parts of the machine are damaged, e.g. safety devices, high pressure hoses, trigger gun. Inadequate extension cords can be dange rous. If an extension cord is used, it shall be suitable for outdoor use, and the connection has to be kept dry and off the ground. It is recommended that this is accomplished by a cord reel which keeps the socket at least 60 mm above the ground. Switch off and unplug the machine when leaving it unattended, when finished using it or when converting it to another function, when doing repair and maintenance.

During use of high pressure washers, aerosols may be formed. Inhalation of aerosols can be hazardous to health, for the protection against aerosols a respiratory mask of class FFP 2 or equivalent may be needed, depending on the cleaning environment.

Gerni Classic 100.5 - Safety Instructions Original Safety Instructions - 1

Intended Use and Terms of Liability The Classic, Classic PG, Super and Super PG series have been developed for domestic cleaning pur poses only and for use in an upright position. Any other use is considered as improper use. ● A high pressure washer operates with different levels of pressure and cleaning detergents for various cleaning tasks and results. Always follow instructions on detergents for use, emergency and disposal. ● Do not operate the machine at temperatures below 0°C. Never start a frozen machine, never use it indoor and never cover it during use. This is considered improper and wrongful use. Use of wrongful pressure, detergent and/or applications may cause damage to machine, surfaces, material and devices. All of the above is considered improper and wrongful use. Gerni accepts no liability for any damage resulting from any improper or wrongful use.

Safety devices and their functioning The machine automatically stops when releasing the trigger. The machine will start again when reactivating the trigger. The spray handle features a locking device. When activated, the spray handle cannot be operated. The machine has an automatic self-resetting thermo protector. If the machine is overheated, the thermo protector will cut the power supply. In this case, wait for the machine to cool down. An integrated hydraulic safety valve protects the system from excessive pressure.

Precautions The electric supply connection shall be made by a qualified electrician and comply with IEC 60364-1. It is recommended that the electric supply to this machine should include either a residual current device that will interrupt the supply if the leakage current to earth exceeds 30 mA for 30 ms or a device that will prove earth circuit. ● Use motor start/delayed fuses with characteristic D according to IEC 947-2 or corresponding standards outside IEC. ● If the supply cord is damaged, it must be replaced by an authorized Gerni distributor or similar qualified person in order to avoid a hazard. ● No actions needed for adjusting machines marked with dual voltage and frequency. ● Supervise children not to play with the machine. ● The operator and any one in the immediate vicinity of the site for cleaning should take action to protect oneself from being struck by debris dislodged during operation. ● Always wear safety boots, respiratory mask, ear protection,

goggles and protective clothing during operation. ● The high pressure generated by the machine is a particular source of danger. Hold the spray lance firmly with both hands. The spray lance is affected by a kickback force and a sudden torque during operation. ● See Part 3:3 for the actual size of the kickback force. ● During transportation: Position the machine horizontally on the backside and secure with straps.

Within EU High pressure washers shall not be used nor maintained by children. The machine can be used by people with reduced physical, sensory or mental capabilities or lack of experience and knowledge if given supervision or instructions concerning use of the machine in a safe way and understands the hazards involved.

Outside EU High pressure washers shall not be used nor maintained by children or untrained people or people with reduced physical, sensory or mental capabilities or lack of experience and knowledge.

Part 2:3 provides a general overview of the machine and operation elements along with illustrated sections on preparation, operation, water connection, storage, and user maintenance.

A Unpacking and preparing for use Follow illustrations in A.

B Connection to potable water mains 📂 High pressure washers are not suitable for connection to the potable water mains. Always check national regulations before connecting the machine to potable water mains and use a back-fl ow preventer if required. ● Use ½" garden hose, 10-25 m. ● Follow illustrations in B.

C Connection to other water sources You can connect the machine to e.g. rain water vessels, rivers, lakes and cisterns etc. and operate it in suction mode. Follow illustrations in C.

D Pairing of spray handle and machine Classic PG and Super PG series only. After battery insert, D1.1, you have 2 min. to pair spray handle and machine. The light will flash orange when searching for the machine. When paired, the light will turn off. Follow illustrations D1.1 to D1.5. If pairing aborts, do pairing according to illustrations D2.1 to D2.5. Power regulation is indicated by green light, see illustration D3.1 and D3.2.

E Leaving the machine unattended > 5 min. ⚠️ See listed warnings. Follow the illustrations in E.

F After use and storage After use always: Turn off the machine. Empty machine and accessories of water to avoid frost damage. Remove the plug from socket. Disconnect water

inlet hose. Wind up electrical cable and high pressure hose to avoid damage of cable, high pressure hose and fittings. Storage of machine shall be frost free. ● Follow illustrations in F.

G Maintenance, inspection and repair Maintenance of the machine should always be done when starting up after long time of storage. Before use, always inspect the machine and equipment for damages. In case of damages, act according to listed warnings. ● Do not attempt any maintenance not described in the instructions. If the machine refuses to start, stops, pulsates, pressure fluctuates, motor buzzes, fuse blows or no water comes out, check the trouble shooting diagram in Part 3:3 Troubleshooting, Serial specifi c Technical Data and Disposal. Any repair should always be made in Gerni authorized workshop with original Gerni spare parts. ● User maintenance according to illustrations in G.

Warranty Conditions

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Gerni high pressure washers for domestic use are warranted for 2 years from the date of purchase by:

AUSTRALIA: Nilfisk Pty LTd, Unit 1/13 Bessemer Street, Blacktown NSW 2148, Phone: 1300 556 710, E-mail: Warranty.au@nilfi sk.com

NEW ZEALAND: Accent Tools Ltd, 232 Bush Rd, Albany, Auckland 0632, Phone: 09 968 2610, E-mail: sales@accent-tools.co.nz

Equipment defects covered by this warranty will be repaired or replaced by one of the service centres of the Gerni organisation. Find your local service agent here: http://www.gerni.com.au/. If your high pressure washer or acces so ries are handed in for repair, it must be followed by a description/specification of the fault, and the original purchase receipt, or a copy, must be enclosed. Packing and postage/carriage is not covered by the warranty. This warranty is provided in addition to the other rights and remedies of the purchaser under the laws in relation to the goods to which the warranty relates. Guarantee repairs are made on the following con dit ions:

  • that defects are attributable to flaws or defects in materials or workmanship (wear and tear as well as misuse are not covered by the gu a ran tee).
  • that the directions of the instruction manual have been thoroughly observed.
  • that repair has not been carried out or attempted by other than Gerni-trained service staff.
  • that only original Gerni accessories have been applied.
  • that the product has not been exposed to abuse such as knocks, bumps or frost.
    • that only water without any impurities has been used.
  • that the high pressure washer has not been used for rental nor used commercial ly in any other way.

Repairs not covered by the guarantee conditions will be invoiced. (i.e. malfunctions due to Causes men ti o ned in section Troubleshooting of Part 3:3.

Please phone 1300 733 171 (Australia) or 09 9682610 (NZ) for service or warranty assistance only after checking possible causes in Part 3:3.

Gerni

Unit 193 Beander Street Blacktown NSW 2148 | Tel. 1300 556 71

Part 2:3 User Guide High Pressure Washers, Classic 100, 105, 110, 115, 120 and 125 series Caution: Read the instructions before using the machine

Gerni Classic 100.5 - Gerni - 1

Gerni Classic 100.5 - Gerni - 2

Gerni Classic 100.5 - Gerni - 3
Classic 100/Classic 105 Classic 110/Classic 115

Gerni Classic 100.5 - Gerni - 4

Gerni Classic 100.5 - Gerni - 5
Classic 120/Classic 120XTRA

Gerni Classic 100.5 - Gerni - 6
Classic 125 / Classic 125 X-TRA

Gerni Classic 100.5 - Gerni - 7

natural_image Technical line drawing of a mechanical device with labeled components (no text or symbols)

Gerni Classic 100.5 - Gerni - 8

12534026 2(04 2016)

Gerni Classic 100.5 - Gerni - 9

Gerni Classic 100.5 - Gerni - 10

Diagram illustrating various automotive safety and cleaning techniques with labeled icons and numerical values, likely for vehicle repair or maintenance.

Recycling the high pressure washer

Make the old machine unusable immediately.

  • Unplug the machine.
  • Cut the electric cable.

Do not discard electrical appliances with household waste. As specified in WEEE Directive 2012/19/EC on old electrical and electronic appliances, used electrical goods must be collected separately and recycled ecologically. Contact your local authorities or your nearest dealer for further information.

Gerni Classic 100.5 - Recycling the high pressure washer - 1

Gerni

Gerni Classic 100.5 - Gerni - 1

Gerni Classic 100.5 - Gerni - 2

Caution:

Read the instructions

before using the machine

128334141 a (04.2016)

Unit 1/13 Bessemer Street | Blacktown NSW 2148 | Tel.: 1300 556 710

Part 3:3 Troubleshooting, Technical Data and Disposal, High Pressure Washers Classic 100, 105, 110, 115, 120 and 125 series

Troubleshooting

To avoid unnecessary disappointments, you should check the following before contacting the Gerni service organization.

Symptom Cause Recommended action
Machine refuses to startMachine not plugged in Defective socketFuse has blownDefective extension cablePlug in machineTry another socket.Replace fuse. Switch off other machines.Try without the extension cable.
Fluctuating pressure Pump sucking airValves dirty, worn out or stuckPump seals worn outCheck that hoses and connections are airtight.Contact tour local Gerni Service centre.Clean and replace or refer to local Gerni distributor.
Machine stops Fuse has blownIncorrect mains voltageThermal sensor activatedNozzle partially blockedReplace fuse. Switch off other machines.Check that the mains voltage corresponds to speciti cation on the model tag.Leave the washer for 5 minutes to cool down.Clean the nozzle (see Part 2.3, G)
Fuse blows Fuse too small Change to an installation higher than the amp.comption of the machine. You may try without the extension cable.
Machine pulsatingAir in inlet hose/pumpInadequate supply of mains waterNozzle partially blockedWater if iter blockedHose kinkedAllow machine to run with open trigger until regular working pressure resumes.Check that the water supply corresponds to speciti cations required (see model tag)NB! Avoid using long, thin hoses (min. 1/2")Clean the nozzle (see Part 2.3, G)Clean the if iter (see Part 2.3, G)Straighten out hose.
Machine often starts and stops by itselfPump/spray handle is leaking Contact your nearest Gerni Service Centre.
Machine starts, but no water comes outPump/hoses or accessory frozenNo water supplyWater if iter blockedNozzle blockedWait for pump/hoses or accessory to thaw.Connect inlet water.Clean the if iter (see Part 2.3, G)Clean the nozzle (see Part 2.3, G)

In case problems other than the above occur, please phone 1300 733 171 or check our website www.gerni.com.au for your nearest service agent.

Technical Data

Electrical Specifications
Protection Class
Protection degree
Hydraulic specifications
Max. water inlet pressure
Max water inlet temperature
Max water inlet temp. suction mode
Kickback force
Weight
ISO 3349-1Hand-arm vibration according to: Standard nozzle
ISO 3740Sound pressure level LpA
2000/12/20Guaranteed sound power level LWA
Unom220-240 V
from50/60 Hz
P1.3 kW 1.4 kW 1.5 kW
from6A 6.5 A
Class I Class IIClass II
IP XXIP X5
Pnom7 MPa / 70 bar 75 MPa / 75 bar 8MPa / 80 bar 8.5 MPa / 85 bar 8.5 MPa / 85 bar 9.5 MPa / 95 bar
Pmax10 MPa / 100 bar10.5 MPa / 105 bar11 MPa / 110 bar11.5 MPa / 115 bar12 MPa / 120 bar 12.5 MPa / 125 bar
Q5.3 min / 320 in5.2 min / 310 in 5.4 min / 320 in
Qmax7.3 min / 440 in 7.7 min / 460 in
P inlet max1 Mpa / 10 bar
t inlet max40°C
t inlet max20°C
Fcklock<20 N
M machine5.1 kg 6.0 kg6.2 kg6.4 kg6.6 kg
an<2.5 ± 1 m/s2
LpAstandard69.2 ± 3 dB(A)71.2 ± 3 dB(A)71.8 ± 3 dB(A)69.9 ± 3 dB(A)
LwAstandard84 dB(A)86 dB(A)85 dB(A)85 dB(A)