| Product Type | Multiple Connector Plate for CPV Valve Terminal |
| Brand | Festo |
| Model | CPV14-VI-P8-1/8-D |
| Compatible Valve Terminal | CPV14 series |
| Mounting Cut-out Dimensions (P8) | A=42.6 mm, B=114.5 mm, C=55.6 mm, D=96 mm, N=6 |
| Number of Screws (P8) | 6 |
| Screw Type | Corrosion-resistant M5 screws per DIN EN ISO 4762 |
| Screw Depth | 7.5 mm to 9.5 mm |
| Tightening Torque | 5 Nm ±10% |
| Protection Class | IP65 (when properly sealed) |
| Seals Included | Yes; 3 and 4-part seals for end plates |
| Sealing Surface Requirements | Flat, free of marks and scratches |
| Material | Metal/plastic (typical industrial grade) |
| Function | Electrical connection and sealing for valve terminals |
| Assembly Requirement | Press seals into holes, position plate from inside, fasten with screws |
| Torque Tolerance | ±10% |
| Series Variants | P2, P4, P6, P8 (different number of slots) |
| Certification | DIN EN ISO 4762 (screws) |
| Manual Page Count | 2 pages |
Frequently Asked Questions - CPV14-VI-P8-1/8-D Festo
User questions about CPV14-VI-P8-1/8-D Festo
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Uncategorized in PDF format for free! Find your manual CPV14-VI-P8-1/8-D - Festo and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CPV14-VI-P8-1/8-D by Festo.
USER MANUAL CPV14-VI-P8-1/8-D Festo
natural_image
Isometric line drawing of a multi-tiered electrical connector with terminal blocks and connectors (no text or symbols)
![Diagram showing a component assembly with pins and a labeled section [1]/[2] indicating a pin configuration or assembly.](/content/2026/05/855078/images/f80baefbe568daaf868367a9909921270ba9fb6b579cef8395b3149a05939713.jpg)
$$ l - t = 7, 5 \mathrm{mm} \dots 9, 5 \mathrm{mm} $$

$$ 5 \mathrm{Nm} \pm 10\% $$

natural_image
Technical illustration of a mechanical assembly with pins and a housing (no text or symbols)2. Preparing for assembly





- Note the dimensions of the cut-out for fitting (→ Table).
In order to comply with protection class IP65: - Make sure that the surface near the sealing surface:
- is flat.
- is free of marks and scratches.
Mounting cut-out for
CPV14-VI-P...-D 1
| Type | A ± 0.1 | B ± 0.1 | C ± 0.1 | D ± 0.1 | N |
| CPV14-VI-P...-D 1 | |||||
| P2 | 42.6 | 30.5 | 55.6 | 12 | 4 |
| P4 | 42.6 | 58.5 | 55.6 | 40 | 6 |
| P6 | 42.6 | 86.5 | 55.6 | 68 | 6 |
| P8 | 42.6 | 114.5 | 55.6 | 96 | 6 |
3. Assembly

natural_image
Isometric line drawing of a multi-tiered electrical connector with terminal blocks (no text or symbols)- Press the seals 3 supplied into the holes in the CPV valve terminal.
- Note that the 3 and 4-part seals supplied with the end plates of the CPV valve terminal are only required with multiple connector plate [2].
- Position multiple connector plate 1 or 2 in the mounting cut-out from inside.


$$ l - t = 7. 5 \mathrm{mm} \dots 9. 5 \mathrm{mm} $$

- Fasten the multiple connector plate 1 or 2 with corrosion resistant N x M5 screws as per DIN EN ISO 4762.
- Select the screw length l as follows. A screw depth of at least 7.5 mm to max. 9.5 mm must be guaranteed.
- Tighten the screws. Maintain the permitted tightening torque.
For mounting the valve terminal:
- Observe the assembly instructions for the pneumatic section of the valve terminal.