Product Type DIN Rail Power Supply
Model DRA-60-12
Input Voltage 85-264 VAC (50/60 Hz) or 120-370 VDC
Output Voltage 12 VDC
Output Current 5 A
Output Power 60 W
Efficiency ≥ 88% at full load (230 VAC)
Dimensions (W x H x D) 32 x 124 x 102 mm
Weight 0.4 kg
Cooling Free air convection
Operating Temperature -20°C to +70°C (derating above 50°C)
Protection Short circuit, overload, over voltage, over temperature
Safety Standards UL 508, EN 60950-1, EN 60199-1
Mounting DIN Rail EN 60715 TH35-7.5/15
Wiring Terminal block (screw type)
LED Indicator Green: output ON; Red: overload or short circuit
Maintenance Periodic cleaning with dry compressed air; check terminal tightness
Repairability Non-repairable; replace unit if faulty
Accessories None included; separate DC circuit breaker recommended

Frequently Asked Questions - DRA-60-12 Mean Well

What is the input voltage range for the Mean Well DRA-60-12?
The input voltage range is 85-264 VAC (50/60 Hz) or 120-370 VDC.
Can the DRA-60-12 be used in a 24V system?
No, the DRA-60-12 outputs a fixed 12 VDC. For 24V, consider the DRA-60-24 model.
What is the maximum output current?
The maximum output current is 5 A at 12 VDC.
What protections does the DRA-60-12 have?
It includes protections against short circuit, overload, over voltage, and over temperature.
After fault removal, the unit automatically recovers.
How do I mount the DRA-60-12 on a DIN rail?
Clip the unit onto a 35mm DIN rail (EN 60715 TH35). Ensure the locking tab snaps into place. For removal, use a screwdriver to pull down the tab.
What does the green/red LED indicate?
Green indicates normal output. Red indicates overload or short circuit condition.
Is the DRA-60-12 suitable for outdoor use?
It has an IP20 rating, so it is not suitable for outdoor or wet environments. Install in a dry, ventilated enclosure.
Can I adjust the output voltage?
No, the output voltage is fixed at 12 VDC and is not adjustable.
What is the recommended input protection?
Use a circuit breaker or fuse rated for the input current (e.g., 1A for 230 VAC) on the AC line.
How should I clean the power supply?
Disconnect power and use dry compressed air to remove dust. Do not use water or solvents.

User questions about DRA-60-12 Mean Well

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Industrial power supply in PDF format for free! Find your manual DRA-60-12 - Mean Well and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DRA-60-12 by Mean Well.

USER MANUAL DRA-60-12 Mean Well

● Type : DRA DIN rail power supply (Series : DRA-40, DRA-60)

DRA-40-12 INPUT: 100-240VAC 0.8A 50/60Hz OUTPUT: 12V 3.34A

DRA-40-24 INPUT: 100-240VAC 0.8A 50/60Hz OUTPUT: 24V 1.7A

DRA-60-12 INPUT: 100-240VAC 1.3A 50/60Hz OUTPUT: 12V 5A

DRA-60-24 INPUT: 100-240VAC 1.3A 50/60Hz OUTPUT: 24V 2.5A

- Introduction

DRA is a DIN rail power supply series featuring adjustable output current. Users are able to set its output current to a range of 10% - 100% of rated current via 1-10Vdc, PWM signal or resistance. Like other Mean Well's DIN series, they can be mounted on a TS35 Standard DIN rail.

- Installation

(1) Always allow good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(2) The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on the top. Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not allowed.

Mean Well DRA-60-12 - - Installation - 1

natural_image Three electronic devices with X-shaped prohibition signs, no text or symbols present

(3) Use copper wire only, and recommended wires are shown as below.

AWG18161412
Rated Current of Equipment (Amp)7101520
Cross-section of Lead( mm2 )0.81.32.13.3
Note: Current each wire carries should be de-rated to 80% of the current suggested above when using 4-6 wires connected to the unit.

Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please make sure each contact is connected to wires to prevent too much current stress on a single contact.

(4) Use wires that can withstand temperatures of at least 80ircC , such as UL1007.
(5) Recommended wire strapping length is 5mm (0.197").
(6) Recommended screwdriver is 3mm, slotted type.
(7) The recommended torque setting for terminals(TB1) is 5 kgf-cm (4.4 Lb-in), terminals(TB2) is 5.8 kgf-cm (5 Lb-in).
(8) Each unit requires 0.15mA when dimming function is used. Please make sure your controller is capable of driving the units.

Installation Manual

(9) Suggested fuse and maximum number of the DRA that can be connected to a circuit breaker at 230V are shown as below.

ModelFuseCircuit breaker
C16D16
DRA-40T2.5A/L250V1121
DRA-60T2.5A/L250V816

(10) Mounting Instruction :

Mount as shown in figure only, with input terminals down, or else sufficient cooling will not be possible.

Admissible DIN rail : TS35/7.5 or TS35/15

For rail fastening :

Mean Well DRA-60-12 - Installation Manual - 1

(a) Tilt the unit slightly rearwards.
(b) Fit the unit over top hat rail.
(c) Slide it downward until it hits the stop.
(d) Press against the bottom for locking.
(e) Shake the unit slightly to check the locking action.

Mean Well DRA-60-12 - Installation Manual - 2

Diagram illustrating a hand holding a device with an arrow indicating rotation, alongside a magnified view of the device's internal structure.

Mean Well DRA-60-12 - Installation Manual - 4

"Click"

(11) For other information about the products, please refer to www.meanwell.com for details.

● Warning / Caution !!

(1) Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do not remove the case of the power supply by yourself!
(2) Risk of electric arcs and electric shock (danger to life). Connecting both the primary and the secondary sides together is not allowed.
(3) Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection!
(4) Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
(5) Only install the unit in a pollution degree 2 environment (Note.1).
(6) Please do not install the unit in places with high moisture or near the water.
(7) The maximum operating temperature is 45irc C for the DRA-60-12, 50irc C for the DRA-60-24, DRC-60A and DRC-60B, 55irc C for the DRA-40-12/24, DRC-40A and DRC-40B, please do not install the unit in places with high ambient temperature or near fire source.
(8) The FG ( 12 ) must be connected to PE (Protective Earth).
(9) Output current and output wattage must not exceed the rated value on its specification.

(10) Disconnect system from supply voltage:

Before commencing any installation, maintenance or modification work: Disconnect your system from supply voltage. Make sure that inadvertent connection in circuit will be impossible!

Note.1: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refer to dry, well-ventilated locations, such as control cabinets.

Manufacturer :

MEAN WELL ENTERPRISES Co., LTD.

No.28, Wuquan 3rd Rd., Wugu Dist.,

New Taipei City 24891, Taiwan

Tel: +886-2-2299-6100

Web: www.meanwell.com

Branch Office :

China

MEAN WELL (GUANGZHOU)

ENTERPRISES Co., LTD.

2F, A Building, Yuean Industry Park,

Huangcun, Dongpu Yown, Tianhe

District, Gungzhou, China

Post Code:510660

Tel: +86-20-2887-1200

Web: www.meanwell.com.cn

U.S.A.

MEAN WELL USA, INC.

44030 Fremont Blvd., Fremont,

CA 94538, U.S.A.

Tel: +1-510-683-8886

Web: www.meanwellusa.com

Europe

MEAN WELL EUROPE B.V.

Langs de Werf 8, 1185XT

Amstelveen, The Netherlands

Tel: +31-20-758-6000

Web: www.meanwell.eu

Declaration of China RoHS Conformity

In order to reduce the impacts on the environment and take the more responsibility for protecting the earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products.

Environment Friendly Use Period Label

10

Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products

Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly Use Period of Electronic Information Products Appendix B, adopting table look-up to verify the Environment Friendly Use Period

Names and Contents of Hazardous Substances Lists

Part NameHazardous Substances
Lead (Pb)Mercury (Hg)Cadmium (Cd)Hexavalent chromium ( Cr6+ )Polybrominated biphenyls (PBB)Polybrominated diphenyl ethers (PBDE)
PCB and its componentsXOOXOO
Metal structure partsXOOOOO
Plastic structure partsOOOOOO
AccessoriesOOOOOO
CablesXOOOOO
O: The concentration of the hazardous substances within the homogeneous material of that product is less than the concentration limits set by GB/T 26572-2011.X: The concentration of the hazardous substances within the homogeneous material of that product is over the concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.