| Product Type | Instantaneous Water Heater & Storage Water Heater |
| Brand | Fakir |
| Model | CALENTA |
| Power Consumption | 3.5 kW – 7.5 kW (adjustable) |
| Voltage | 230 V AC, 50/60 Hz |
| Max Flow Rate | 5 L/min |
| Temperature Range | 30 °C – 60 °C |
| Material | ABS plastic body, copper heating element |
| Dimensions (H x W x D) | 300 mm x 200 mm x 110 mm |
| Weight | 2.5 kg |
| Protection Class | IPX4 (splash proof) |
| Safety Features | Thermal cutoff, anti-scald protection, flow sensor |
| Display | Digital LED temperature display |
| Controls | Touch button for temperature and flow adjustment |
| Installation | Wall-mounted, horizontal or vertical |
| Water Connection | 1/2 inch BSP inlet/outlet |
| Energy Efficiency | Energy class A |
| Maintenance | Descaling every 6 months recommended |
| Spare Parts Availability | Heating element, thermistor, control board |
| Warranty | 2 years |
Frequently Asked Questions - CALENTA FAKIR
User questions about CALENTA FAKIR
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Chauffe-eau instantané et chauffe-eau in PDF format for free! Find your manual CALENTA - FAKIR and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CALENTA by FAKIR.
USER MANUAL CALENTA FAKIR
natural_image
White Fakir self-service water heater with a gray handle and control knob (no visible text or symbols on body)- Front Cover
- Adjusting key
- Signal lamp
- Hot water outlet tube
- Cold water enter tube
- Hole for the power cord
- Back cover
- Assembling

All the parts that are used in production of Fakir Calenta has CE, TÜV and Turkish Standart Enstitute (TSE) quality document.
ASSEMBLYING INFORMATION
Machine should be connected to the inlet of fuse panel with 32 A automat as it is seen in the schema.
Appliance should be earthed.
Operating voltage : 230V
Power : 30A 3000+4000=7000W
Frequency : 50Hz A.A.
Operating pressure : 4 6 bar
Beat voltage : 330V
Level of isolation : Additional isolation
Usage life : 7 years
Flow: 3 L/min
Dimensions : 350x250x150mm


1- Assembling should be made to the water battery.
2- Water control valve should be connected to the inlet.
3- With the help of the adjusting key, under normal conditions, 30-60-80 degree centigrate hot water could be supplied.
Attention! Please avoid closing the hot water outflow with tap, valve or something else.
PROTECTION SYSTEM WITH 7 SAFETY EQUIPMENT
1- Safety valve against excessive water pressure.
2- Original fireproof material and additional isolated outer surface.
3- Earthted route connection that protect against leak.
4- Diaphgram system that stops the energy entrance in the case of water cut off
5- Fireproof insider cord assembly
6- Protector against excessive heat with single thermostat
7- Resistance that is not calcificated and with additional isolation.
Not:
There is no threat of leak at our equipment. It is approved by TSE.
MAINTENANCE INSTRUCTIONS
1- After fixing the equipment, the tempeture of the water could be adjusted by turning the key to 1,2 or 3 according to the season and need.
2- You could adjust the water tempature also by the tap.
3- In the case of connection of battery has made, you should close water inlet valve, fuse and the adjusting key after the operation finished.
IMPORTANT POINTS FOR MAINTENANCE
1- To make your equipment works longer and to avoid the calcification, the adjusting key should come to "0" point and the tap should be open till the water starts to come cold
2- The frosted equipment should not be used. Before using, the environment should be warmed and the adjusted key should be moved after the water has pour for 3 minutes. (The
problems that rooted from the getting icy is not under the guarantee.
3- While equipment is on working, other equipment with high voltage should not use the same electrical line.
4- The cover of equipment should not be opened by people other than authorized technical service staff.
5- The company is not responsible from the defects that rooted from the operations of unauthorized people.
MAINTAINCE OF ELECTRICAL INSTANT WATER HEATER
Maintaince of the electrical instant water heater should be made by Fakir Authorized Services otherwise our company is not responsible for problems that may arise. First of all, bring the switch off that connected to the device to make the electrical connection discontinued. Clean the device with an appropriate detergent against calcification that may occur over time, do not use substances such as solvents that could damage the device.
ATTENTION:
- In the case of any defect, you should apply to the Fakir Technical Service Staff. Assembling of the appliance is done by authorized technical Fakir services. Free Installation.
TRANSPORTATION
Please keep and carry the product with its original box and follow the marks on the box. Please take precaution for the impacts that may occur on the outer surface of the box.