Irritrol 2400DK-1-MF - Irrigation system

2400DK-1-MF - Irrigation system Irritrol - Free user manual and instructions

Find the device manual for free 2400DK-1-MF Irritrol in PDF.

📄 7 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Irritrol 2400DK-1-MF - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Irrigation Sprinkler Valve
Model 2400DK-1-MF
Brand Irritrol
Dimensions (L x W x H) 10 cm x 7 cm x 12 cm
Weight 350 g
Inlet Size 1 inch (25.4 mm) female NPT
Outlet Size 1 inch (25.4 mm) female NPT
Operating Pressure 1.5 to 10.5 bar (150 to 1050 kPa)
Flow Rate Up to 20 L/min
Power Supply 24 VAC, 50/60 Hz (solenoid)
Electrical Current 0.3 A inrush, 0.2 A holding
Maximum Ambient Temperature 50°C (122°F)
Body Material High-strength engineering polymer
Seal Material Nitrile rubber (NBR)
Internal Components Stainless steel spring, brass plunger
Primary Functions On/off control of water flow for sprinkler systems
Installation Type In-line or manifold mount
Manual Override Bleed screw for manual operation
Flow Control Adjustable by turning solenoid or bleed screw
Maintenance Periodic cleaning of filter and solenoid plunger
Safety Features Anti-siphon design (check local codes)
Spare Parts Solenoid coil, plunger assembly, diaphragm kit
Repairability User replaceable diaphragm and solenoid
Warranty 2 years limited
Certifications cULus listed, ASME A112.18.1

Frequently Asked Questions - 2400DK-1-MF Irritrol

What is the operating pressure range for the Irritrol 2400DK-1-MF?
The operating pressure range is 1.5 to 10.5 bar (150 to 1050 kPa).
How do I manually open the valve?
Turn the bleed screw (usually located on top of the solenoid) counterclockwise to manually bleed water and open the valve. Ensure you close it fully after use.
Can this valve be installed underground?
Yes, the valve is designed for direct burial in an irrigation system, provided it is placed in a gravel sump or valve box for access.
What is the correct voltage for the solenoid?
The solenoid operates on 24 VAC at 50/60 Hz. Using a different voltage may damage the coil.
How do I clean or replace the diaphragm?
Turn off water, remove the solenoid and bonnet (top cover) to access the diaphragm. Clean or replace with the Diaphragm Kit (model 2400DK). Reassemble in reverse order.
What is the maximum flow rate?
The valve supports flow rates up to 20 L/min (5.3 GPM) at optimal pressure.
Why does the valve not close completely?
Possible causes: debris in the diaphragm, worn diaphragm, or low pressure. Clean the diaphragm and check pressure between 1.5-10.5 bar.
How do I adjust the flow rate?
Flow adjustment can be done by turning the solenoid or the bleed screw; turning clockwise restricts flow, counterclockwise increases it.
Is this valve compatible with all Irritrol controllers?
Yes, the 2400DK-1-MF uses a standard 24 VAC solenoid and fits most Irritrol and other brand controllers.
What spare parts are available?
Available spare parts include the solenoid coil, plunger assembly, and diaphragm kit (model 2400DK).

User questions about 2400DK-1-MF Irritrol

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Irrigation system in PDF format for free! Find your manual 2400DK-1-MF - Irritrol and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 2400DK-1-MF by Irritrol.

USER MANUAL 2400DK-1-MF Irritrol

Drip Zone Valve Kits Installation Instructions

Click on the links to view the documents.

Drip Zone Valve Kit

Models 2500DK-1-LF and 2500DK-1-MF

Installation Instructions

373-0512 Revision B

Drip Zone Valve Kit

Models 2711APRDK-LF and 2711APRDK-MF

Installation Instructions

373-0513 Revision B

Drip Zone Valve Kit

Models 2713APRDK-LF and 2713APRDK-MF

Installation Instructions

373-0514 Revision B

Drip Zone Valve Kit

Models 700DK-075-LF

Installation Instructions

373-0515 Revision B

Drip Zone Valve Kit

Models 700DK-1-LF and 700DK-1-MF

Installation Instructions

373-0516 Revision B

Drip Zone Kit - Less Valve

Models DK-LV-LF and DK-LV-MF

Installation Instructions

373-0535 Revision A

Drip Zone Valve Kit Models 2500DK-1-LF and 2500DK-1-MF Installation Instructions

Kit Components

  • Irritrol 2500 Series Valve, Model 2500TF
  • Pressure Regulator - 25 psi at 0.1–8 GPM, 3/4" Female NPT (Low Flow [LF] model)
  • Pressure Regulator - 25 psi at 2–20 GPM, 3/4" Female NPT (Medium Flow [MF] model)
    • 3/4" MPT x MPT F Series Y-filter, 150 Mesh Screen
    • Drip Line Compression Adapter, CA-710
    • 1" x 3/4" Male NPT Reducer Bushing
    • 3/4" MPT x 1/2" Slip Fitting

Specifications

  • Downstream Pressure Regulation: 25 psi
  • Flow Rate at 25 psi: (LF Model) 0.1–8 GPM (MF Model) 2–20 GPM
    • Filtration: 150 Mesh Stainless Steel Screen
    • 1" In-line Electric Control Valve, Model 2500TF
    ♦ Operating Pressure: 10–150 psi
    ♦ 24 VAC, 50/60 Hz Solenoid
    ♦ Inrush: 0.40 amp, 9.6 VA
    ♦ Holding: 0.20 amp, 4.8 VA
    • Manual On/Off - Internal and External Bleed
  • Adjustable Flow Control

Installation Procedure

CAUTION: When assembling the drip zone valve kit components, use just 1 12 to 2 turns of PTFE tape on male threads. Never use pipe dope. To achieve a leak-free thread connection, turn the male fitting until it is finger-tight, and then add one or two more turns. Over-tightening can cause splitting and failure of the female threads.

⚠️ Important: Ensure the Y-filter, control valve and pressure regulator are installed in the correct flow orientation. Flow direction arrows are provided on each component. Refer to Figure 1.

  1. Thread the Y-filter inlet into the valve outlet with the provided 1" x 3/4" NPT reducer bushing. Use PTFE tape on all threaded connections. Angle the Y-filter slightly downward as shown in Figure 1.
  2. Thread the pressure regulator inlet into the Y-filter outlet.
  3. Connect the water source supply line and piping to drip emitters.

NOTE: Installing the valve assembly below grade in a valve box is recommended for protection and ease of service.

NOTE: Refer to the 2500TF Series Valve Instruction Guide provided in the kit for complete valve installation and operation information.

NOTE: To adapt the Drip Zone Valve Kit for dripline applications, install the provided 3/4" MPT x 1/2" Slip fitting and CA-710 dripline compression adapter to the pressure regulator outlet.

  1. Flush the system to remove debris.
  2. To determine the recommended minimum/maximum number of drip emitters per control valve, refer to the table below.

Table 1

Emitter (GPH)Low FlowMedium Flow
0.530–960240–2400
1.015–480120–1200
2.01–24060–600

Compression Adapter (Use with Flex Tube only) 3/4" MPT x 1/2" Slip Pressure Regulator Y-filter 2500TF Series Valve Reducer Bushing Valve Box To Emitters From Source

Kit Components

  • Irritrol 2700 Series Valve, Model 2711APR
  • Pressure Regulator - 25 psi at 0.1–8 GPM, 3/4" Female NPT (Low Flow [LF] model)
  • Pressure Regulator - 25 psi at 2–20 GPM, 3/4" Female NPT (Medium Flow [MF] model)
  • 3/4" MPT x MPT F Series Y-filter, 150 Mesh Screen
    • Drip Line Compression Adapter, CA-710
  • 3/4" MPT x 1/2" Slip Fitting

Specifications

  • Downstream Pressure Regulation: 25 psi
  • Flow Rate at 25 psi: (LF Model) 0.1–8 GPM (MF Model) 2–20 GPM
    • Filtration: 150 Mesh Stainless Steel Screen
  • 3/4" Anti-siphon Electric Control Valve, Model 2711APR
    ♦ Operating Pressure: 10–150 psi
    ♦ 24 VAC, 50/60 Hz Solenoid
    ♦ Inrush: 0.40 amp, 9.6 VA
    ♦ Holding: 0.20 amp, 4.8 VA
  • Manual On/Off - Internal and External Bleed
    ♦ Adjustable Flow Control

Installation Procedure

CAUTION: When assembling the drip zone valve kit components, use just 1½ to 2 turns of PTFE tape on male threads. Never use pipe dope. To achieve a leak-free thread connection, turn the male fitting until it is finger-tight, and then add one or two more turns. Over-tightening can cause splitting and failure of the female threads.
⚠️ Important: Ensure the Y-filter, control valve and pressure regulator are installed in the correct flow orientation. Flow direction arrows are provided on each component. Refer to Figure 1.

  1. Thread the Y-filter inlet into the valve outlet. Use PTFE tape on all threaded connections. Angle the Y-filter slightly downward as shown in Figure 1.

  2. Thread the pressure regulator inlet into the Y-filter outlet.

  3. Connect the water source supply line and piping to drip emitters.

NOTE: Refer to the 2711APR Series Valve Instruction Guide provided in the kit for complete valve installation and operation information.

NOTE: To adapt the Drip Zone Valve Kit for dripline applications, install the provided 3/4" MPT x 1/2" Slip fitting and CA-710 dripline compression adapter to the pressure regulator outlet.

  1. Flush the system to remove debris.

  2. To determine the recommended minimum/maximum number of drip emitters per control valve, refer to the table below.

Table 1

Emitter (GPH)Low FlowMedium Flow
0.530–960240–2400
1.015–480120–1200
2.01–24060–600

Figure 1 NOTE: The valve must be installed at least 6" above the highest emitter it controls. 2711APR Valve Y-filter Pressure Regulator To Emitters 3/4" MPT x 1/2" Slip Compression Adapter (Use with Flex Tube only) From Source

Kit Components

  • Irritrol 2700 Series Valve, Model 2713APR
  • Pressure Regulator - 25 psi at 0.1–8 GPM, 3/4" Female NPT (Low Flow [LF] model)
  • Pressure Regulator - 25 psi at 2–20 GPM, 3/4" Female NPT (Medium Flow [MF] model)
  • 3/4" MPT x MPT F Series Y-filter, 150 Mesh Screen
    • Drip Line Compression Adapter, CA-710
  • 1" x 3/4" Male NPT Reducer Bushing
    • 3/4" MPT x 1/2" Slip Fitting

Specifications

  • Downstream Pressure Regulation: 25 psi
  • Flow Rate at 25 psi: (LF Model) 0.1–8 GPM (MF Model) 2–20 GPM
    • Filtration: 150 Mesh Stainless Steel Screen
    • 1" Anti-siphon Electric Control Valve, Model 2713APR
    ♦ Operating Pressure: 10–150 psi
    ♦ 24 VAC, 50/60 Hz Solenoid
    ♦ Inrush: 0.40 amp, 9.6 VA
    ♦ Holding: 0.20 amp, 4.8 VA
  • Manual On/Off - Internal and External Bleed
  • Adjustable Flow Control

Installation Procedure

CAUTION: When assembling the drip zone valve kit components, use just 1½ to 2 turns of PTFE tape on male threads. Never use pipe dope. To achieve a leak-free thread connection, turn the male fitting until it is finger-tight, and then add one or two more turns. Over-tightening can cause splitting and failure of the female threads.

⚠️ Important: Ensure the Y-filter, control valve and pressure regulator are installed in the correct flow orientation. Flow direction arrows are provided on each component. Refer to Figure 1.

  1. Thread the Y-filter inlet into the valve outlet with the provided 1" x 3/4" NPT reducer bushing. Use PTFE tape on all threaded connections. Angle the Y-filter slightly downward as shown in Figure 1.
  2. Thread the pressure regulator inlet into the Y-filter outlet.
  3. Connect the water source supply line and piping to drip emitters.

NOTE: Refer to the 2713APR Series Valve Instruction Guide provided in the kit for complete valve installation and operation information.

NOTE: To adapt the Drip Zone Valve Kit for dripline applications, install the provided 3/4" MPT x 1/2" Slip fitting and CA-710 dripline compression adapter to the pressure regulator outlet.

  1. Flush the system to remove debris.
  2. To determine the recommended minimum/maximum number of drip emitters per control valve, refer to the table below.

Table 1

Emitter (GPH)Low FlowMedium Flow
0.530–960240–2400
1.015–480120–1200
2.01–24060–600

Figure 1 NOTE: The valve must be installed at least 6" above the highest emitter it controls. 2713APR Valve Reducer Bushing Y-filter Pressure Regulator To Emitters 3/4" MPT x 1/2" Slip Compression Adapter (Use with Flex Tube only) From Source

Kit Components

  • Irritrol 700 Series Valve, Model 700B-.75
  • Pressure Regulator - 25 psi at 0.1–8 GPM, 3/4" Female NPT
    • 3/4" MPT x MPT F Series Y-filter, 150 Mesh Screen
    • Drip Line Compression Adapter, CA-710
    • 3/4" MPT x 1/2" Slip Fitting

Specifications

  • Downstream Pressure Regulation: 25 psi
    • Flow Rate at 25 psi: 0.1–8 GPM
    • Filtration: 150 Mesh Stainless Steel Screen
    • 1" In-line Electric Control Valve, Model 700B-.75
    ♦ Operating Pressure: 10–150 psi
    ♦ 24 VAC, 50/60 Hz Solenoid
    • Inrush: 0.40 amp, 9.6 VA
    ♦ Holding: 0.20 amp, 4.8 VA
  • Manual On/Off - Internal and External Bleed
  • Adjustable Flow Control

Installation Procedure

CAUTION: When assembling the drip zone valve kit components, use just 1 ½ to 2 turns of PTFE tape on male threads. Never use pipe dope. To achieve a leak-free thread connection, turn the male fitting until it is finger-tight, and then add one or two more turns. Over-tightening can cause splitting and failure of the female threads.

⚠️ Important: Ensure the Y-filter, control valve and pressure regulator are installed in the correct flow orientation. Flow direction arrows are provided on each component. Refer to Figure 1.

  1. Thread the Y-filter inlet into the valve outlet. Use PTFE tape on all threaded connections. Angle the Y-filter slightly downward as shown in Figure 1.
  2. Thread the pressure regulator inlet into the Y-filter outlet.
  3. Connect the water source supply line and piping to drip emitters.

NOTE: Installing the valve assembly below grade in a valve box is recommended for protection and ease of service.

NOTE: Refer to the 700 Series Valve Instruction Guide provided in the kit for complete valve installation and operation information.

NOTE: To adapt the Drip Zone Valve Kit for dripline applications, install the provided 3/4" MPT x 1/2" Slip fitting and CA-710 dripline compression adapter to the pressure regulator outlet.

  1. Flush the system to remove debris.
  2. To determine the recommended minimum/maximum number of drip emitters per control valve, refer to the table below.

Table 1

Emitter (GPH)Low FlowMedium Flow
0.530–960240–2400
1.015–480120–1200
2.01–24060–600

Compression Adapter (Use with Flex Tube only) 3/4" MPT x 1/2" Slip Pressure Regulator Y-filter 700 Series Valve Valve Box To Emitters From Source Figure 1

Irritrol®

Get more done™

Drip Zone Valve Kit Models 700DK-1-LF and 700DK-1-MF Installation Instructions

Kit Components

  • Irritrol 700 Series Valve, Model 700-1
  • Pressure Regulator - 25 psi at 0.1–8 GPM, 3/4" Female NPT (Low Flow [LF] model)
  • Pressure Regulator - 25 psi at 2–20 GPM, 3/4" Female NPT (Medium Flow [MF] model)
  • 3/4" MPT x MPT F Series Y-filter, 150 Mesh Screen
    • Drip Line Compression Adapter, CA-710
    • 1" x 3/4" Male NPT Reducer Bushing
    • 3/4" MPT x 1/2" Slip Fitting

Specifications

  • Downstream Pressure Regulation: 25 psi
  • Flow Rate at 25 psi: (LF model) 0.1–8 GPM (MF model) 2–20 GPM
    • Filtration: 150 Mesh Stainless Steel Screen
    • 1" In-line Electric Control Valve, Model 700-1
    ♦ Operating Pressure: 10–150 psi
    • 24 VAC, 50/60 Hz Solenoid
    ♦ Inrush: 0.40 amp, 9.6 VA
    ♦ Holding: 0.20 amp, 4.8 VA
  • Manual On/Off - Internal and External Bleed
  • Adjustable Flow Control

Installation Procedure

CAUTION: When assembling the drip zone valve kit components, use just 1 ½ to 2 turns of PTFE tape on male threads. Never use pipe dope. To achieve a leak-free thread connection, turn the male fitting until it is finger-tight, and then add one or two more turns. Over-tightening can cause splitting and failure of the female threads.

⚠️ Important: Ensure the Y-filter, control valve and pressure regulator are installed in the correct flow orientation. Flow direction arrows are provided on each component. Refer to Figure 1.

  1. Thread the Y-filter inlet into the valve outlet with the provided 1" x 3/4" NPT reducer bushing. Use PTFE tape on all threaded connections. Angle the Y-filter slightly downward as shown in Figure 1.
  2. Thread the pressure regulator inlet into the Y-filter outlet.
  3. Connect the water source supply line and piping to drip emitters.

NOTE: Installing the valve assembly below grade in a valve box is recommended for protection and ease of service.

NOTE: Refer to the 700 Series Valve Instruction Guide provided in the kit for complete valve installation and operation information.

NOTE: To adapt the Drip Zone Valve Kit for dripline applications, install the provided 3/4" MPT x 1/2" Slip fitting and CA-710 dripline compression adapter to the pressure regulator outlet.

  1. Flush the system to remove debris.
  2. To determine the recommended minimum/maximum number of drip emitters per control valve, refer to the table below.

Table 1

Emitter (GPH)Low FlowMedium Flow
0.530–960240–2400
1.015–480120–1200
2.01–24060–600

Compression Adapter (Use with Flex Tube only) 3/4" MPT x 1/2" Slip Pressure Regulator Y-filter 700 Series Valve Reducer Bushing Valve Box To Emitters From Source

Irritrol®

Get more done™

Drip Zone Kit - Less Valve Models DK-LV-LF and DK-LV-MF Installation Instructions

Kit Components

  • Pressure Regulator - 25 psi at 0.1–8 GPM, 3/4" Female NPT (Low Flow [LF] model)
  • Pressure Regulator - 25 psi at 2–20 GPM, 3/4" Female NPT (Medium Flow [MF] model)
    • 3/4" MPT x MPT F Series Y-filter, 150 Mesh Screen
    • Drip Line Compression Adapter, CA-710
  • 1" x 3/4" Male NPT Reducer Bushing
  • 3/4" MPT x 1/2" Slip Fitting

Specifications

• Maximum Supply Pressure: 150 psi
- Downstream Pressure Regulation: 25 psi
- Flow Rate at 25 psi: (LF model) 0.1–8 GPM (MF model) 2–20 GPM
• Filtration: 150 Mesh Stainless Steel Screen

Installation Procedure

CAUTION: When assembling the drip zone kit components, use just 1 12 to 2 turns of PTFE tape on male threads. Never use pipe dope. To achieve a leak-free thread connection, turn the male fitting until it is finger-tight, and then add one or two more turns. Over-tightening can cause splitting and failure of the female threads.

⚠️ Important: Ensure the Y-filter and pressure regulator are installed in the correct flow orientation. Flow direction arrows are provided on each component. Refer to Figure 1.

  1. Thread the pressure regulator inlet into the Y-filter outlet.
  2. Connect the water source supply line and piping to drip emitters.

NOTE: Installing the assembly below grade in a valve box is recommended for protection and ease of service.

NOTE: To adapt the Drip Zone Kit for dripline applications, install the provided 3/4" MPT x 1/2" Slip fitting and CA-710 dripline compression adapter to the pressure regulator outlet.

  1. Flush the system to remove debris.

  2. To determine the recommended minimum/maximum number of drip emitters per control valve, refer to the table below.

Table 1

Emitter (GPH)Low FlowMedium Flow
0.530–960240–2400
1.015–480120–1200
2.01–24060–600

Compression Adapter (Use with Flex Tube only) 3/4" MPT x 1/2" Slip Y-filter Pressure Regulator Valve Box To Emitters From Source Figure 1

© Irritrol • www.irritrol.com • For Technical Assistance, call 1-800-333-3125 Part Number 373-0535 revision A

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Irritrol

Model : 2400DK-1-MF

Category : Irrigation system