C02 - Thermostat Fantini Cosmi - Free user manual and instructions
Find the device manual for free C02 Fantini Cosmi in PDF.
| Product Type | Rear Panel Capillary Thermostat |
| Model | C02 |
| Brand | Fantini Cosmi |
| Application | Temperature control for water in boilers, air conditioning, cooling units, domestic appliances, electric ovens |
| Operating Principle | Liquid expansion |
| Contact Rating | 15(6)A 250V AC (15A resistive, 6A FLA/36LRA) |
| Switch Type | SPDT microswitch with gold contacts |
| Protection Degree | IP00 |
| Terminal Type | FASTON 6.3mm (external wires); screw terminals available for internal wires |
| Maximum Terminal Temperature (internal wires) | 130°C |
| Maximum Head Temperature | 785°C |
| Micro-disconnection Type | 1B |
| Mounting | Rear panel (incorporated control) |
| Sensor Material | Stainless steel (memorando sensor) |
| Bulb and Capillary Material | Copper (tin plated for C02C2 and C02D2) |
| Housing Material | Shock-proof self-extinguishing thermoplastic V0 (1.6mm) |
| Pollution Degree | 2 (per EN/UL/CSA 60730-1) |
| Insulation Voltage (nominal) | 380V (per EN 60947-5-1) |
| Special Executions Available | Special temperature range, fixed calibration, manual reset, internal setting, clamps terminals (for high quantity) |
| Accessories | Various accessories for rear panel mounting |
| Maintenance | Keep clean and dry; no user-serviceable parts |
| Safety Compliance | EN/UL/CSA 60730-1, EN/UL/CSA 60730-2-9, EN 60947-5-1 |
Frequently Asked Questions - C02 Fantini Cosmi
User questions about C02 Fantini Cosmi
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Thermostat in PDF format for free! Find your manual C02 - Fantini Cosmi and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. C02 by Fantini Cosmi.
USER MANUAL C02 Fantini Cosmi
Rear panel capillary C02-- series can be supplied with many accessories in order to make easy the rear panel mounting.
SPECIAL EXECUTIONS (only for high qty; please ask for offer)
Rear panel capillary C02-- series thermostats can be supplied in special executions in accordance with customer specifications: special temperature range, fixed calibration, fixed calibration with manual reset, internal temperature setting and eletrical terminals with clamps instead of "FASTON".
RETRO
ACCESSORI DI SERIE PER TERMOSTATI C02-- / ACCESSORIES FOR C02--
Rear panel capillary C02—series can be supplied with many accessories in order to make easy the rear panel mounting.
SPECIAL EXECUTIONS (only for high qty; please ask for offer)
Rear panel capillary C02-- series thermostats can be supplied in special executions in accordance with customer specifications: special temperature range, fixed calibration, fixed calibration with manual reset, internal temperature setting and electrical terminals with clamps instead of "FASTON".
NB: PIEGARE CON DUE PIEGHE INCROCIATE FORMATO CHIUSO 105x148mm
FRONTE
FantiniCosmi
VIA DELL'OSIO, 6 20090 CALEPPIO DI SETTALA MI
Tel. 02956821 fax 0295307006
- Capillary thermostat for water temperature control in boilers, air conditioning.
cooling units and systems, domestic appliances and electric ovens.
- Montaggio a retroquadr. - Rear panel mounting
– Liquid expansion operation.
—Stainless steel memorando sensor. —Bulbo e capillare in rame.
— Copper bulbe and capillary tube
— Tin plated copper for C02C2 and C02D2 types. — Basetta coperchio e manogola in ma
autoestinguente V0 1.6mm.
- Base, cover and knob made of shock-proof self-extinguishing thermoplastic V0.


CARATTERISTICHE TECNICHE SECONDO EN/UL/CSA 60730-1,
EN/UL/CSA 60730-2-9: TECHNICAL FEATURES ACCORDING TO EN/UL/CSA 60730-1.
EN/UL/CSA 60730-2-9:
- Portata contatti 15(6) - Contact rating 15(6)
- Contact rating 15(6)A 250V - 50Hz - 15A carico resistivo, 6A FLA/36LRA
-15A resistive load, 6A FLA/36LRA 240Vac 50/80Hz
– SPDT microswitch, with gold
- Protection degree IP00
– Wire connection (external wires), "FASTON" terminals 6,3mm
—Special wires (joint to screw terminals for internal wires): wires
suitable to the temperature, heatproof wires — Temperature massima dei morsetti per cond
- Maximum temperature of the terminals for internal wires 130°C
–Maximum head temperature 785°C
-Micro/disconnection type 1B
—Mounting way, to be included (incorporated control)
—Period of electrical stress of the insulating parts, long period
- Grado d'inquinamento 2 - Pollution degree 3
-Opening temperature: Opens 1-2, closes 1-



CARATTERISTICHE TECNICHE SECONDO EN 60947-5-1 TECHNICAL FEATURES ACCORDING TO EN 60947-5-1
TECHNICAL FEATURES/ACCORDING TO EN 06947-5-1. Tensione nominale d'isolamento
Nominal insulation tension UI 380-
Resistive load AC-12 - 15A 10A