USER MANUAL ELLIPSE PRO 1200 IEC EATON
Register warranty at: powerquality.eaton.com
Battery disposal and safety
• Caution. Battery service life is reduced by 50 % for every ten degrees above 25 °C. • The battery must be replaced exclusively by qualified personnel (risk of shock), with new battery approved by Eaton to ensure correct operation of the UPS. • The battery must be disposed of in accordance with applicable regulations. To remove the battery, shut down the UPS (button 6 OFF), remove the power cord and proceed as indicated below "Battery change".
• Warning: take care not to inverse the polarity + (red) and - (black) when connecting the battery as this will destroy the device.
Technical characteristics
Ellipse PRO • UPS power • Nominal input voltage • Input frequency • Voltage/frequency of battery backup outlets 19 in battery mode • Total output current for all outlets • Output current of battery backup outlets 19 • Leakage current • Input protection • Transfer time • Telephone/Data surge protection • Sealed lead-acid battery • Automatic battery test • Average battery life • Operating temperature • Storage temperature • Operating relative humidity • Operating elevation • Safety standards • Electromagnetic compatibility standards • Warranty • Dimensions (mm/inch) • Weigth (kg/lb)
1200 1600 850 VA / 1200 VA / 1600 VA / 510 W 750 W 1000 W 165 V - 264 V, adjustable to 150 V - 284 V 50/60 Hz (46 - 70 Hz working range) 220 V / 230 V / 240 V +15 % -20 % (50/60 Hz ± 1 Hz)
10 A resettable circuit breaker 5 ms typical Tel, ISDN, ADSL, Ethernet 12 V, 7 Ah 12 V, 9 Ah 2x12V, 7 Ah 2x12V, 9 Ah Once a week 4 years typical, depending on temperature and number of discharge cycles 0 to 35 °C -25 °C to +55 °C 0 to 85 % 0 to 2000 m IEC 62040-1, CE certified IEC 62040-2, C1* 3 years 260 x 82 x 285 / 10.24 x 3.23 x 11.22 275 x 82 x 390 / 10.83 x 3.23 x 15.35 6.9 / 15.2 7.3 / 16.1 9.7 / 21.4 11.5 / 25.4
(*) Warning: Output cables should not exceed 10 m length.
Performances tested according to IEC 61643-1 (class 3) standard for 8/20 µs surge wave
AC input source protection, Ellipse PRO: • Uoc (common mode / differential mode) • Up (common mode / differential mode) • In
Temporary overvoltage (TOV)
1. Operating conditions
• T his product is an Uninterruptible Power Supply (UPS) for computers and their peripherals, television sets, stereo systems and video recorders... It must not be used to supply other electrical equipment (lighting, heating, household appliances, etc.). • UPS can be installed in horizontal, vertical position, or placed in Rack 2U (optional kit).
6 ON/OFF button for the
battery backup outlets
Battery mode Internal fault Output load level Battery level Input measurements Output measurements Measuring unit
18 Surge protection outlets
19 Battery backup outlets 20 Protection (circuit breaker)
• C onnect the UPS 1 to the AC-power system via a wall outlet with an earth connector, using the supplied cord 4 for a UPS with FR/DIN sockets or with the supply cord of your computer for a UPS with IEC sockets (see figure A). • Plug critical equipment (computer, monitor, modem, etc.) into the outlets 19 providing battery backup power and surge protection (see figure B), taking care not to exceed the rated current indicated in amperes. • Other devices (printer, scanner, fax, etc.) can be connect to the surge protection outlets 18 (see figure B). The surge protection outlets are not backed up by battery power in the event of a power outage. Optional Internet modem / Network connection: A modem or Ethernet data line can be protected against surges by connecting it via the UPS. Connect the existing device cable between the wall outlet and the UPS, and use a similar cable between the UPS and the device, as indicated in figure C (cable not supplied). Optional USB connection: The UPS device can be connected to the computer using the USB cable 5 supplied (see figure C). The software is available on the CD-ROM 5 or Eaton UPS Companion software is downloadable from powerquality.eaton.com. Register for the warranty on powerquality.eaton.com.
4. Master and EcoControl outlets operating procedure
In order to limit energy consumption of peripherals (scanner, printer) in standby mode, the Ellipse PRO is equipped with EcoControl outlets that are dependent on the Master outlet. When the main device supplied by the Master outlet (computer) is shut down, the EcoControl outlets are automatically deactivated and the peripherals shut down. This function (deactivated by default) is validated and configured using the configuration tool integrated in the software. Note: when the function is activated, do not connect critical applications to EcoControl outlets.
A default setup ensures the correct operation of the EcoControl function. However, depending on the consumption of the main load, the trigger threshold of the EcoControl function may have to be modified using the configuration software supplied with the UPS: • First, make sure that the function is activated in the "EcoControl Function" tab of the configuration tool. • If the peripherals connected to the EcoControl outlets do not switch off when the main load is not in normal operation (ex: when in standby mode), the detection threshold value must be set to High. • If the rated consumption level of the main load is low and the EcoControl outlets shut down when the main load is operating normally, the detection threshold value must be set to Low.
5. UPS setting through the LCD Release scroll down button to select menu
Input voltage tolerance
LCD shut off if no activity for 3 minutes.
Battery charge The UPS charges the battery as soon as it is connected to the AC outlet, whether button 6 is pressed or not. When used for the first time, the battery will only provide its maximum performance after it has been charged for 8 hours. It is recommended that the UPS be permanently connected to the AC power supply to ensure the best possible performance. Switching-on the UPS Press button 6 for about 1 second. Surge protection outlets 18 without battery backup Equipment connected to these outlets is supplied as soon as the AC cord 4 is plugged in. They are not affected by button 6 . Battery backup outlets 19 Equipment connected to these outlets is supplied as soon as button 6 turns green (see figure D). These outlets can be turned on even if the UPS is not connected to AC power (button 6 flashes).
AC-power disturbance
• If AC power is disturbed or fails, the UPS continues to operate on battery power. Button 6 flashes green. In normal mode, the audible alarm beeps every ten seconds, then every three seconds when the end of battery backup time is near. In silent mode, the audible alarm simply beeps once when the UPS transfers to battery power. • If the power outage lasts longer than the battery backup time, the UPS shuts down and automatically restarts when power is restored. Following a complete discharge, a few hours are required to recharge the battery back to full backup time. Surge protection: All outlets include surge protection. Shutdown of the battery backup outlets 19 Press button 6 for more than two seconds.
(For further information, visit the www.powerquality.eaton.com site or contact after-sales support.)
• The battery backup outlets 19 are not supplied with power.
• The connected devices are not supplied when AC power fails. • AC power is available, but the UPS operates on battery power.
• Button 6 is not lighted on.
• Press button 6 and check that it turns green.
• Connect the devices to the battery backup outlets 19 . • Disconnect excess equipment and reset the circuit breaker 20 by pressing the corresponding button.
• The devices are not connected to the battery backup outlets 19 .
• Circuit breaker 20 , located at the rear of the UPS, has been tripped by an overload on the UPS output. • The UPS battery backup outlets 19 are overloaded.
• Disconnect excess equipment connected to the battery backup outlets 19 .
• Green button 6 flashes and audible alarm beeps every 3 seconds.
• Fault sign 12 appear on the LCD panel and audible alarm beeps continuously.
• A fault has occurred on the UPS. • Call after-sales support.
The battery backup outlets 19 are no longer supplied.
• Green LED 8 is off and the filtered outlets 18 are supplied.
• EcoControl outlets keep powered when main application (Master outlet) is stopped.
• Surge protection is no longer provided.
• Call after-sales support.
• EcoControl function is not activated or not properly set.
• Activate or set properly
EcoControl function using the software provided with the product.