| Product Type | Medical Grade LCD Monitor |
| Brand | NEC |
| Model | MD211G3 |
| Display Size | 21.3 inches |
| Panel Resolution | 1600 x 1200 (UXGA) |
| Aspect Ratio | 4:3 |
| Panel Technology | IPS (In-Plane Switching) |
| Brightness | 400 cd/m² |
| Contrast Ratio | 1000:1 |
| Viewing Angle | 178° horizontal / 178° vertical |
| Response Time | 12 ms |
| Color Support | 16.77 million colors |
| Video Inputs | DVI-D, DisplayPort, VGA |
| USB Hub | 2-port USB 2.0 |
| Power Consumption | 60 W typical |
| Standby Power | Less than 1 W |
| Power Supply | AC 100-240 V, 50/60 Hz |
| Dimensions (W x H x D) | 460 x 480 x 210 mm |
| Weight | 8.5 kg |
| VESA Mount | 100 x 100 mm |
| Calibration | DICOM Part 14 compliant |
| Ambient Light Sensor | Yes |
| Cleaning Method | Soft dry cloth; mild detergent if needed |
| Safety Standards | IEC 60601-1 certified |
Frequently Asked Questions - MD211G3 NEC
How do I connect the MD211G3 to my computer?
Connect your computer's video output to the monitor using a suitable cable. The monitor supports DVI-D, DisplayPort, and VGA inputs. For best image quality, use a digital connection such as DVI-D or DisplayPort. After connecting, select the corresponding input source using the OSD menu.
What is the native resolution of this monitor?
The native resolution is 1600 x 1200 (UXGA). For the sharpest picture, set your computer to output this resolution. The monitor automatically scales other resolutions to fit the screen, but native resolution is recommended.
How should I clean the screen?
Turn off the monitor and unplug it. Use a soft, dry microfiber cloth to gently wipe the surface. If stains persist, dampen the cloth with a small amount of water or a mild screen cleaner. Do not spray directly onto the screen or use harsh chemicals.
Is the MD211G3 calibrated for medical imaging?
Yes, it is DICOM Part 14 compliant and features factory calibration for accurate grayscale reproduction. For ongoing quality assurance, you can use an external calibration sensor and software to maintain compliance.
Can the monitor be mounted on a wall or arm?
Yes, it has a VESA 100 x 100 mm mounting pattern. Remove the stand and attach a compatible VESA mount. Follow the mounting instructions to ensure safe installation.
How do I change the input source?
Press the Input/Source button on the front control panel to cycle through the available inputs (DVI-D, DisplayPort, VGA). Alternatively, use the OSD menu to select the desired input.
What should I do if the monitor does not power on?
Check that the power cable is securely connected and the wall outlet is live. Press the power button. If the LED indicator remains off, the internal power supply may be faulty – contact authorized service personnel.
Can this monitor be used for regular office work?
Absolutely. While designed for medical environments, it also excels in general office tasks due to its high resolution and accurate color reproduction. Keep in mind it is a premium display optimized for professional use.
How do I adjust brightness and contrast?
Use the OSD menu. Press the Menu button, navigate to "Brightness/Contrast" and adjust the values with the arrow keys. For medical use, keep the brightness at recommended levels to maintain DICOM compliance.
Does the monitor have built-in speakers?
No, the MD211G3 is a professional display without built-in speakers. It focuses on image quality and diagnostic accuracy. Use external speakers if audio is needed.